Advanced search options

Advanced Search Options 🞨

Browse by author name (“Author name starts with…”).

Find ETDs with:

in
/  
in
/  
in
/  
in

Written in Published in Earliest date Latest date

Sorted by

Results per page:

Sorted by: relevance · author · university · dateNew search

You searched for subject:(transducer). Showing records 1 – 30 of 412 total matches.

[1] [2] [3] [4] [5] … [14]

Search Limiters

Last 2 Years | English Only

Degrees

Levels

Languages

Country

▼ Search Limiters


University of Alberta

1. Ge, Chang. Studies of Ultrasound Distribution and Ultrasound Generation Efficiency of Transducers.

Degree: MS, Department of Electrical and Computer Engineering, 2014, University of Alberta

 Renewable energy production is an important application of ultrasound waves. Ultrasound waves can increase the ethanol and biodiesel generated by biomass during metabolic behaviour. Ultrasound… (more)

Subjects/Keywords: Transducer; Ultrasound distribution

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Ge, C. (2014). Studies of Ultrasound Distribution and Ultrasound Generation Efficiency of Transducers. (Masters Thesis). University of Alberta. Retrieved from https://era.library.ualberta.ca/files/mp48sg303

Chicago Manual of Style (16th Edition):

Ge, Chang. “Studies of Ultrasound Distribution and Ultrasound Generation Efficiency of Transducers.” 2014. Masters Thesis, University of Alberta. Accessed September 23, 2019. https://era.library.ualberta.ca/files/mp48sg303.

MLA Handbook (7th Edition):

Ge, Chang. “Studies of Ultrasound Distribution and Ultrasound Generation Efficiency of Transducers.” 2014. Web. 23 Sep 2019.

Vancouver:

Ge C. Studies of Ultrasound Distribution and Ultrasound Generation Efficiency of Transducers. [Internet] [Masters thesis]. University of Alberta; 2014. [cited 2019 Sep 23]. Available from: https://era.library.ualberta.ca/files/mp48sg303.

Council of Science Editors:

Ge C. Studies of Ultrasound Distribution and Ultrasound Generation Efficiency of Transducers. [Masters Thesis]. University of Alberta; 2014. Available from: https://era.library.ualberta.ca/files/mp48sg303


University of Alberta

2. Badawi, Hisham. The use of multi-axis force transducers for orthodontic force and moment identification.

Degree: PhD, Department of Dentistry, 2009, University of Alberta

 Many of the undesirable side effects that occur during orthodontic treatment can be attributed directly to a lack of understanding of the physics involved in… (more)

Subjects/Keywords: multi-axis transducer; orthodontic force

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Badawi, H. (2009). The use of multi-axis force transducers for orthodontic force and moment identification. (Doctoral Dissertation). University of Alberta. Retrieved from https://era.library.ualberta.ca/files/p5547s06q

Chicago Manual of Style (16th Edition):

Badawi, Hisham. “The use of multi-axis force transducers for orthodontic force and moment identification.” 2009. Doctoral Dissertation, University of Alberta. Accessed September 23, 2019. https://era.library.ualberta.ca/files/p5547s06q.

MLA Handbook (7th Edition):

Badawi, Hisham. “The use of multi-axis force transducers for orthodontic force and moment identification.” 2009. Web. 23 Sep 2019.

Vancouver:

Badawi H. The use of multi-axis force transducers for orthodontic force and moment identification. [Internet] [Doctoral dissertation]. University of Alberta; 2009. [cited 2019 Sep 23]. Available from: https://era.library.ualberta.ca/files/p5547s06q.

Council of Science Editors:

Badawi H. The use of multi-axis force transducers for orthodontic force and moment identification. [Doctoral Dissertation]. University of Alberta; 2009. Available from: https://era.library.ualberta.ca/files/p5547s06q


University of California – San Diego

3. Wang, Chonghe. Ultrasonic device for blood pressure measurement.

Degree: NanoEngineering, 2018, University of California – San Diego

 This research will develop a method for continuous, accurate, and non-invasive central blood pressure waveform recording using a stretchable ultrasound device worn on the human… (more)

Subjects/Keywords: Acoustics; blood pressure; ultrasonic transducer

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Wang, C. (2018). Ultrasonic device for blood pressure measurement. (Thesis). University of California – San Diego. Retrieved from http://www.escholarship.org/uc/item/79m9c9n1

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Wang, Chonghe. “Ultrasonic device for blood pressure measurement.” 2018. Thesis, University of California – San Diego. Accessed September 23, 2019. http://www.escholarship.org/uc/item/79m9c9n1.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Wang, Chonghe. “Ultrasonic device for blood pressure measurement.” 2018. Web. 23 Sep 2019.

Vancouver:

Wang C. Ultrasonic device for blood pressure measurement. [Internet] [Thesis]. University of California – San Diego; 2018. [cited 2019 Sep 23]. Available from: http://www.escholarship.org/uc/item/79m9c9n1.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Wang C. Ultrasonic device for blood pressure measurement. [Thesis]. University of California – San Diego; 2018. Available from: http://www.escholarship.org/uc/item/79m9c9n1

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Penn State University

4. Gosain, Rohan. PIEZOELECTRIC PUMP USING CYMBAL TRANSDUCER.

Degree: MS, Electrical Engineering, 2010, Penn State University

 This thesis treats an innovative piezoelectric pump based on one of the piezoelectric actuators, the ‘cymbal’. The performance analysis of a miniaturized, ultrasonic, valve less… (more)

Subjects/Keywords: PIEZOELECTRIC PUMP CYMBAL TRANSDUCER ULTRASONIC

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Gosain, R. (2010). PIEZOELECTRIC PUMP USING CYMBAL TRANSDUCER. (Masters Thesis). Penn State University. Retrieved from https://etda.libraries.psu.edu/catalog/10737

Chicago Manual of Style (16th Edition):

Gosain, Rohan. “PIEZOELECTRIC PUMP USING CYMBAL TRANSDUCER.” 2010. Masters Thesis, Penn State University. Accessed September 23, 2019. https://etda.libraries.psu.edu/catalog/10737.

MLA Handbook (7th Edition):

Gosain, Rohan. “PIEZOELECTRIC PUMP USING CYMBAL TRANSDUCER.” 2010. Web. 23 Sep 2019.

Vancouver:

Gosain R. PIEZOELECTRIC PUMP USING CYMBAL TRANSDUCER. [Internet] [Masters thesis]. Penn State University; 2010. [cited 2019 Sep 23]. Available from: https://etda.libraries.psu.edu/catalog/10737.

Council of Science Editors:

Gosain R. PIEZOELECTRIC PUMP USING CYMBAL TRANSDUCER. [Masters Thesis]. Penn State University; 2010. Available from: https://etda.libraries.psu.edu/catalog/10737


Penn State University

5. Vitt, Nikolas Troy. Investigation of a Balanced-Armature Transducer for Vibrational Energy Harvesting.

Degree: MS, Acoustics, 2011, Penn State University

 <p style="text-indent: 1em;">There are countless portable devices that rely on batteries to operate. In some applications, replacing or recharging batteries is not feasible or is… (more)

Subjects/Keywords: energy harvesting; Balanced-armature; transducer

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Vitt, N. T. (2011). Investigation of a Balanced-Armature Transducer for Vibrational Energy Harvesting. (Masters Thesis). Penn State University. Retrieved from https://etda.libraries.psu.edu/catalog/12164

Chicago Manual of Style (16th Edition):

Vitt, Nikolas Troy. “Investigation of a Balanced-Armature Transducer for Vibrational Energy Harvesting.” 2011. Masters Thesis, Penn State University. Accessed September 23, 2019. https://etda.libraries.psu.edu/catalog/12164.

MLA Handbook (7th Edition):

Vitt, Nikolas Troy. “Investigation of a Balanced-Armature Transducer for Vibrational Energy Harvesting.” 2011. Web. 23 Sep 2019.

Vancouver:

Vitt NT. Investigation of a Balanced-Armature Transducer for Vibrational Energy Harvesting. [Internet] [Masters thesis]. Penn State University; 2011. [cited 2019 Sep 23]. Available from: https://etda.libraries.psu.edu/catalog/12164.

Council of Science Editors:

Vitt NT. Investigation of a Balanced-Armature Transducer for Vibrational Energy Harvesting. [Masters Thesis]. Penn State University; 2011. Available from: https://etda.libraries.psu.edu/catalog/12164


Penn State University

6. Zhu, Jie. Optimization of Matching Layer Design for Medical Ultrasonic Transducer.

Degree: PhD, Materials Science and Engineering, 2008, Penn State University

 Matching layers are crucial components in ultrasonic transducers for medical imaging. Without proper matching layers, large acoustic impedance mismatch between piezoelectric resonator and the human… (more)

Subjects/Keywords: Medical Ultrasonic Transducer; Matching Layer

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Zhu, J. (2008). Optimization of Matching Layer Design for Medical Ultrasonic Transducer. (Doctoral Dissertation). Penn State University. Retrieved from https://etda.libraries.psu.edu/catalog/8444

Chicago Manual of Style (16th Edition):

Zhu, Jie. “Optimization of Matching Layer Design for Medical Ultrasonic Transducer.” 2008. Doctoral Dissertation, Penn State University. Accessed September 23, 2019. https://etda.libraries.psu.edu/catalog/8444.

MLA Handbook (7th Edition):

Zhu, Jie. “Optimization of Matching Layer Design for Medical Ultrasonic Transducer.” 2008. Web. 23 Sep 2019.

Vancouver:

Zhu J. Optimization of Matching Layer Design for Medical Ultrasonic Transducer. [Internet] [Doctoral dissertation]. Penn State University; 2008. [cited 2019 Sep 23]. Available from: https://etda.libraries.psu.edu/catalog/8444.

Council of Science Editors:

Zhu J. Optimization of Matching Layer Design for Medical Ultrasonic Transducer. [Doctoral Dissertation]. Penn State University; 2008. Available from: https://etda.libraries.psu.edu/catalog/8444


Louisiana State University

7. Balasubramanian, Karthik. Foldable substrates for micro-ultrasonic transducers.

Degree: MSEE, Electrical and Computer Engineering, 2011, Louisiana State University

 Ultrasound has broad range of applications from underwater examination, nondestructive testing of materials and medical diagnosis and treatment. The ultrasonic transducer plays an vital role… (more)

Subjects/Keywords: Transducer; Ultrasound; Foldable Substrates

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Balasubramanian, K. (2011). Foldable substrates for micro-ultrasonic transducers. (Masters Thesis). Louisiana State University. Retrieved from etd-08292011-141729 ; https://digitalcommons.lsu.edu/gradschool_theses/1459

Chicago Manual of Style (16th Edition):

Balasubramanian, Karthik. “Foldable substrates for micro-ultrasonic transducers.” 2011. Masters Thesis, Louisiana State University. Accessed September 23, 2019. etd-08292011-141729 ; https://digitalcommons.lsu.edu/gradschool_theses/1459.

MLA Handbook (7th Edition):

Balasubramanian, Karthik. “Foldable substrates for micro-ultrasonic transducers.” 2011. Web. 23 Sep 2019.

Vancouver:

Balasubramanian K. Foldable substrates for micro-ultrasonic transducers. [Internet] [Masters thesis]. Louisiana State University; 2011. [cited 2019 Sep 23]. Available from: etd-08292011-141729 ; https://digitalcommons.lsu.edu/gradschool_theses/1459.

Council of Science Editors:

Balasubramanian K. Foldable substrates for micro-ultrasonic transducers. [Masters Thesis]. Louisiana State University; 2011. Available from: etd-08292011-141729 ; https://digitalcommons.lsu.edu/gradschool_theses/1459


Delft University of Technology

8. Timmers, D. Realization of Ultrasonic Transducer Test Set-Up:.

Degree: 2010, Delft University of Technology

Subjects/Keywords: Ultrasonic; Transducer

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Timmers, D. (2010). Realization of Ultrasonic Transducer Test Set-Up:. (Masters Thesis). Delft University of Technology. Retrieved from http://resolver.tudelft.nl/uuid:029fa7fc-03ad-4d34-a0da-22ea7f00bbab

Chicago Manual of Style (16th Edition):

Timmers, D. “Realization of Ultrasonic Transducer Test Set-Up:.” 2010. Masters Thesis, Delft University of Technology. Accessed September 23, 2019. http://resolver.tudelft.nl/uuid:029fa7fc-03ad-4d34-a0da-22ea7f00bbab.

MLA Handbook (7th Edition):

Timmers, D. “Realization of Ultrasonic Transducer Test Set-Up:.” 2010. Web. 23 Sep 2019.

Vancouver:

Timmers D. Realization of Ultrasonic Transducer Test Set-Up:. [Internet] [Masters thesis]. Delft University of Technology; 2010. [cited 2019 Sep 23]. Available from: http://resolver.tudelft.nl/uuid:029fa7fc-03ad-4d34-a0da-22ea7f00bbab.

Council of Science Editors:

Timmers D. Realization of Ultrasonic Transducer Test Set-Up:. [Masters Thesis]. Delft University of Technology; 2010. Available from: http://resolver.tudelft.nl/uuid:029fa7fc-03ad-4d34-a0da-22ea7f00bbab


Penn State University

9. Juntarapaso, Yada. SIMULATIONS FOR INVESTIGATING THE CONTRAST MECHANISM OF BIOLOGICAL CELLS WITH HIGH FREQUENCY SCANNING ACOUSTIC MICROSCOPY.

Degree: 2017, Penn State University

 Scanning Acoustic Microscopy (SAM) is one of the most powerful techniques for nondestructive evaluation and it is a promising tool for characterizing the elastic properties… (more)

Subjects/Keywords: scanning acoustic microscopy; transducer simulation

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Juntarapaso, Y. (2017). SIMULATIONS FOR INVESTIGATING THE CONTRAST MECHANISM OF BIOLOGICAL CELLS WITH HIGH FREQUENCY SCANNING ACOUSTIC MICROSCOPY. (Thesis). Penn State University. Retrieved from https://etda.libraries.psu.edu/catalog/6766yuj105

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Juntarapaso, Yada. “SIMULATIONS FOR INVESTIGATING THE CONTRAST MECHANISM OF BIOLOGICAL CELLS WITH HIGH FREQUENCY SCANNING ACOUSTIC MICROSCOPY.” 2017. Thesis, Penn State University. Accessed September 23, 2019. https://etda.libraries.psu.edu/catalog/6766yuj105.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Juntarapaso, Yada. “SIMULATIONS FOR INVESTIGATING THE CONTRAST MECHANISM OF BIOLOGICAL CELLS WITH HIGH FREQUENCY SCANNING ACOUSTIC MICROSCOPY.” 2017. Web. 23 Sep 2019.

Vancouver:

Juntarapaso Y. SIMULATIONS FOR INVESTIGATING THE CONTRAST MECHANISM OF BIOLOGICAL CELLS WITH HIGH FREQUENCY SCANNING ACOUSTIC MICROSCOPY. [Internet] [Thesis]. Penn State University; 2017. [cited 2019 Sep 23]. Available from: https://etda.libraries.psu.edu/catalog/6766yuj105.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Juntarapaso Y. SIMULATIONS FOR INVESTIGATING THE CONTRAST MECHANISM OF BIOLOGICAL CELLS WITH HIGH FREQUENCY SCANNING ACOUSTIC MICROSCOPY. [Thesis]. Penn State University; 2017. Available from: https://etda.libraries.psu.edu/catalog/6766yuj105

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Université de Neuchâtel

10. Stieger, Christof. Implantable hearing systems: development and evaluation of two concepts.

Degree: 2006, Université de Neuchâtel

 Le traitement de la surdité est basé soit sur l’appareillage acoustique soit sur la microchirugie otologique. Ces méthodes ne sont toutefois pas efficaces pour tous… (more)

Subjects/Keywords: Contactless transducer

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Stieger, C. (2006). Implantable hearing systems: development and evaluation of two concepts. (Thesis). Université de Neuchâtel. Retrieved from http://doc.rero.ch/record/6496

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Stieger, Christof. “Implantable hearing systems: development and evaluation of two concepts.” 2006. Thesis, Université de Neuchâtel. Accessed September 23, 2019. http://doc.rero.ch/record/6496.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Stieger, Christof. “Implantable hearing systems: development and evaluation of two concepts.” 2006. Web. 23 Sep 2019.

Vancouver:

Stieger C. Implantable hearing systems: development and evaluation of two concepts. [Internet] [Thesis]. Université de Neuchâtel; 2006. [cited 2019 Sep 23]. Available from: http://doc.rero.ch/record/6496.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Stieger C. Implantable hearing systems: development and evaluation of two concepts. [Thesis]. Université de Neuchâtel; 2006. Available from: http://doc.rero.ch/record/6496

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Dundee

11. Alibrahim, Anas. The measurement of maximal bite force in human beings.

Degree: PhD, 2015, University of Dundee

 Background: Registering a true maximum bite force on the most commonly-used force transducers is problematic. It is often believed that this is related mainly to… (more)

Subjects/Keywords: 617.6; Bite force; Electromyographic (EMG); Twitch interpolation; Jaw closing muscles; Masseter muscle; Temporalis muscle; Transducer; Pressure transducer; Force transducer

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Alibrahim, A. (2015). The measurement of maximal bite force in human beings. (Doctoral Dissertation). University of Dundee. Retrieved from http://hdl.handle.net/10588/73283c8a-eee6-468b-8300-b79c12ad9f51

Chicago Manual of Style (16th Edition):

Alibrahim, Anas. “The measurement of maximal bite force in human beings.” 2015. Doctoral Dissertation, University of Dundee. Accessed September 23, 2019. http://hdl.handle.net/10588/73283c8a-eee6-468b-8300-b79c12ad9f51.

MLA Handbook (7th Edition):

Alibrahim, Anas. “The measurement of maximal bite force in human beings.” 2015. Web. 23 Sep 2019.

Vancouver:

Alibrahim A. The measurement of maximal bite force in human beings. [Internet] [Doctoral dissertation]. University of Dundee; 2015. [cited 2019 Sep 23]. Available from: http://hdl.handle.net/10588/73283c8a-eee6-468b-8300-b79c12ad9f51.

Council of Science Editors:

Alibrahim A. The measurement of maximal bite force in human beings. [Doctoral Dissertation]. University of Dundee; 2015. Available from: http://hdl.handle.net/10588/73283c8a-eee6-468b-8300-b79c12ad9f51


University of Akron

12. Patel, Darshan Shyam. A Real-Time Technique for the Correction of Invasive Blood Pressure Measurements using Counter Pressure.

Degree: MSin Engineering, Biomedical Engineering, 2008, University of Akron

 In critical care, a fluid-filled catheter transducer system is commonly used to continuously monitor blood pressure. The fluid-filled catheter transducer system, as a first approximation,… (more)

Subjects/Keywords: Biomedical Research; COUNTER PRESSURE; catheter transducer system; BLOOD PRESSURE; transducer system; catheter transducer; PRESSURE WAVE; counter pressure source

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Patel, D. S. (2008). A Real-Time Technique for the Correction of Invasive Blood Pressure Measurements using Counter Pressure. (Masters Thesis). University of Akron. Retrieved from http://rave.ohiolink.edu/etdc/view?acc_num=akron1205764260

Chicago Manual of Style (16th Edition):

Patel, Darshan Shyam. “A Real-Time Technique for the Correction of Invasive Blood Pressure Measurements using Counter Pressure.” 2008. Masters Thesis, University of Akron. Accessed September 23, 2019. http://rave.ohiolink.edu/etdc/view?acc_num=akron1205764260.

MLA Handbook (7th Edition):

Patel, Darshan Shyam. “A Real-Time Technique for the Correction of Invasive Blood Pressure Measurements using Counter Pressure.” 2008. Web. 23 Sep 2019.

Vancouver:

Patel DS. A Real-Time Technique for the Correction of Invasive Blood Pressure Measurements using Counter Pressure. [Internet] [Masters thesis]. University of Akron; 2008. [cited 2019 Sep 23]. Available from: http://rave.ohiolink.edu/etdc/view?acc_num=akron1205764260.

Council of Science Editors:

Patel DS. A Real-Time Technique for the Correction of Invasive Blood Pressure Measurements using Counter Pressure. [Masters Thesis]. University of Akron; 2008. Available from: http://rave.ohiolink.edu/etdc/view?acc_num=akron1205764260


University of Dundee

13. Alibrahim, Anas. The measurement of maximal bite force in human beings.

Degree: PhD, 2015, University of Dundee

 Background: Registering a true maximum bite force on the most commonly-used force transducers is problematic. It is often believed that this is related mainly to… (more)

Subjects/Keywords: 617.6; Bite force; Electromyographic (EMG); Twitch interpolation; Jaw closing muscles; Masseter muscle; Temporalis muscle; Transducer; Pressure transducer; Force transducer

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Alibrahim, A. (2015). The measurement of maximal bite force in human beings. (Doctoral Dissertation). University of Dundee. Retrieved from https://discovery.dundee.ac.uk/en/studentTheses/73283c8a-eee6-468b-8300-b79c12ad9f51 ; https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.650176

Chicago Manual of Style (16th Edition):

Alibrahim, Anas. “The measurement of maximal bite force in human beings.” 2015. Doctoral Dissertation, University of Dundee. Accessed September 23, 2019. https://discovery.dundee.ac.uk/en/studentTheses/73283c8a-eee6-468b-8300-b79c12ad9f51 ; https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.650176.

MLA Handbook (7th Edition):

Alibrahim, Anas. “The measurement of maximal bite force in human beings.” 2015. Web. 23 Sep 2019.

Vancouver:

Alibrahim A. The measurement of maximal bite force in human beings. [Internet] [Doctoral dissertation]. University of Dundee; 2015. [cited 2019 Sep 23]. Available from: https://discovery.dundee.ac.uk/en/studentTheses/73283c8a-eee6-468b-8300-b79c12ad9f51 ; https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.650176.

Council of Science Editors:

Alibrahim A. The measurement of maximal bite force in human beings. [Doctoral Dissertation]. University of Dundee; 2015. Available from: https://discovery.dundee.ac.uk/en/studentTheses/73283c8a-eee6-468b-8300-b79c12ad9f51 ; https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.650176

14. Sponheimer, Chris. Influence of Compressible Aerogel Electrodes on the Properties of an Electrochemical Cell.

Degree: PhD, Bioengineering, 2010, U of Denver

  In the biomedical field the need for intra organ pressure measurement can only be facilitated by adapting existing pressure sensing technology to the specific… (more)

Subjects/Keywords: aerogel; electrochemical; gelatin; pressure; sensor; transducer

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Sponheimer, C. (2010). Influence of Compressible Aerogel Electrodes on the Properties of an Electrochemical Cell. (Doctoral Dissertation). U of Denver. Retrieved from https://digitalcommons.du.edu/etd/620

Chicago Manual of Style (16th Edition):

Sponheimer, Chris. “Influence of Compressible Aerogel Electrodes on the Properties of an Electrochemical Cell.” 2010. Doctoral Dissertation, U of Denver. Accessed September 23, 2019. https://digitalcommons.du.edu/etd/620.

MLA Handbook (7th Edition):

Sponheimer, Chris. “Influence of Compressible Aerogel Electrodes on the Properties of an Electrochemical Cell.” 2010. Web. 23 Sep 2019.

Vancouver:

Sponheimer C. Influence of Compressible Aerogel Electrodes on the Properties of an Electrochemical Cell. [Internet] [Doctoral dissertation]. U of Denver; 2010. [cited 2019 Sep 23]. Available from: https://digitalcommons.du.edu/etd/620.

Council of Science Editors:

Sponheimer C. Influence of Compressible Aerogel Electrodes on the Properties of an Electrochemical Cell. [Doctoral Dissertation]. U of Denver; 2010. Available from: https://digitalcommons.du.edu/etd/620


Brunel University

15. Engineer, Bhavin Arun. The mechanical and resonant behaviour of a dry coupled thickness-shear PZT transducer used for guided wave testing in pipe line.

Degree: PhD, 2013, Brunel University

 The guided wave technique is an ultrasonic technique which is used to monitor large structures in a variety of industry sectors to safeguard against catastrophic… (more)

Subjects/Keywords: 621.8; Guided waves; Transducer; Dry coupled

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Engineer, B. A. (2013). The mechanical and resonant behaviour of a dry coupled thickness-shear PZT transducer used for guided wave testing in pipe line. (Doctoral Dissertation). Brunel University. Retrieved from http://bura.brunel.ac.uk/handle/2438/13910 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.701886

Chicago Manual of Style (16th Edition):

Engineer, Bhavin Arun. “The mechanical and resonant behaviour of a dry coupled thickness-shear PZT transducer used for guided wave testing in pipe line.” 2013. Doctoral Dissertation, Brunel University. Accessed September 23, 2019. http://bura.brunel.ac.uk/handle/2438/13910 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.701886.

MLA Handbook (7th Edition):

Engineer, Bhavin Arun. “The mechanical and resonant behaviour of a dry coupled thickness-shear PZT transducer used for guided wave testing in pipe line.” 2013. Web. 23 Sep 2019.

Vancouver:

Engineer BA. The mechanical and resonant behaviour of a dry coupled thickness-shear PZT transducer used for guided wave testing in pipe line. [Internet] [Doctoral dissertation]. Brunel University; 2013. [cited 2019 Sep 23]. Available from: http://bura.brunel.ac.uk/handle/2438/13910 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.701886.

Council of Science Editors:

Engineer BA. The mechanical and resonant behaviour of a dry coupled thickness-shear PZT transducer used for guided wave testing in pipe line. [Doctoral Dissertation]. Brunel University; 2013. Available from: http://bura.brunel.ac.uk/handle/2438/13910 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.701886


Loughborough University

16. Forward, M. J. Measurement of 3D forces at the foot-shoe interface during locomotor activity.

Degree: PhD, 1997, Loughborough University

 The origin of this project was the problem of foot ulceration in the diabetic patient. Whilst the principal cause of the susceptibility to foot ulceration… (more)

Subjects/Keywords: 612; Transducer electronics

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Forward, M. J. (1997). Measurement of 3D forces at the foot-shoe interface during locomotor activity. (Doctoral Dissertation). Loughborough University. Retrieved from https://dspace.lboro.ac.uk/2134/13502 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.362681

Chicago Manual of Style (16th Edition):

Forward, M J. “Measurement of 3D forces at the foot-shoe interface during locomotor activity.” 1997. Doctoral Dissertation, Loughborough University. Accessed September 23, 2019. https://dspace.lboro.ac.uk/2134/13502 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.362681.

MLA Handbook (7th Edition):

Forward, M J. “Measurement of 3D forces at the foot-shoe interface during locomotor activity.” 1997. Web. 23 Sep 2019.

Vancouver:

Forward MJ. Measurement of 3D forces at the foot-shoe interface during locomotor activity. [Internet] [Doctoral dissertation]. Loughborough University; 1997. [cited 2019 Sep 23]. Available from: https://dspace.lboro.ac.uk/2134/13502 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.362681.

Council of Science Editors:

Forward MJ. Measurement of 3D forces at the foot-shoe interface during locomotor activity. [Doctoral Dissertation]. Loughborough University; 1997. Available from: https://dspace.lboro.ac.uk/2134/13502 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.362681


University of Alberta

17. Lu,huihong. Design, Fabrication, and Testing of High-Frequency High-Numerical-Aperture Annular Array Transducer for Improved Depth-of-Field Photoacoustic Microscopy.

Degree: MS, Department of Electrical and Computer Engineering, 2012, University of Alberta

 Researchers have been using single-element transducers for photoacoustic microscopy (PAM), but such systems have limited depth-of-field due to single focus. This project was to develop… (more)

Subjects/Keywords: high-frequency; annular-array; ultrasound-transducer

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Lu,huihong. (2012). Design, Fabrication, and Testing of High-Frequency High-Numerical-Aperture Annular Array Transducer for Improved Depth-of-Field Photoacoustic Microscopy. (Masters Thesis). University of Alberta. Retrieved from https://era.library.ualberta.ca/files/wh246t10x

Note: this citation may be lacking information needed for this citation format:
Author name may be incomplete

Chicago Manual of Style (16th Edition):

Lu,huihong. “Design, Fabrication, and Testing of High-Frequency High-Numerical-Aperture Annular Array Transducer for Improved Depth-of-Field Photoacoustic Microscopy.” 2012. Masters Thesis, University of Alberta. Accessed September 23, 2019. https://era.library.ualberta.ca/files/wh246t10x.

Note: this citation may be lacking information needed for this citation format:
Author name may be incomplete

MLA Handbook (7th Edition):

Lu,huihong. “Design, Fabrication, and Testing of High-Frequency High-Numerical-Aperture Annular Array Transducer for Improved Depth-of-Field Photoacoustic Microscopy.” 2012. Web. 23 Sep 2019.

Note: this citation may be lacking information needed for this citation format:
Author name may be incomplete

Vancouver:

Lu,huihong. Design, Fabrication, and Testing of High-Frequency High-Numerical-Aperture Annular Array Transducer for Improved Depth-of-Field Photoacoustic Microscopy. [Internet] [Masters thesis]. University of Alberta; 2012. [cited 2019 Sep 23]. Available from: https://era.library.ualberta.ca/files/wh246t10x.

Note: this citation may be lacking information needed for this citation format:
Author name may be incomplete

Council of Science Editors:

Lu,huihong. Design, Fabrication, and Testing of High-Frequency High-Numerical-Aperture Annular Array Transducer for Improved Depth-of-Field Photoacoustic Microscopy. [Masters Thesis]. University of Alberta; 2012. Available from: https://era.library.ualberta.ca/files/wh246t10x

Note: this citation may be lacking information needed for this citation format:
Author name may be incomplete

18. Trinath, K. Studies on modified PZT ceramics for transducer applications; -.

Degree: Physics, 1997, Pt. Ravishankar Shukla University

None

Bibliography p.149-150

Advisors/Committee Members: Bhanumathi, A.

Subjects/Keywords: ceramics; transducer applications

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Trinath, K. (1997). Studies on modified PZT ceramics for transducer applications; -. (Thesis). Pt. Ravishankar Shukla University. Retrieved from http://shodhganga.inflibnet.ac.in/handle/10603/43727

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Trinath, K. “Studies on modified PZT ceramics for transducer applications; -.” 1997. Thesis, Pt. Ravishankar Shukla University. Accessed September 23, 2019. http://shodhganga.inflibnet.ac.in/handle/10603/43727.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Trinath, K. “Studies on modified PZT ceramics for transducer applications; -.” 1997. Web. 23 Sep 2019.

Vancouver:

Trinath K. Studies on modified PZT ceramics for transducer applications; -. [Internet] [Thesis]. Pt. Ravishankar Shukla University; 1997. [cited 2019 Sep 23]. Available from: http://shodhganga.inflibnet.ac.in/handle/10603/43727.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Trinath K. Studies on modified PZT ceramics for transducer applications; -. [Thesis]. Pt. Ravishankar Shukla University; 1997. Available from: http://shodhganga.inflibnet.ac.in/handle/10603/43727

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


NSYSU

19. Chien, Huang-Chen. Implementation of a DSP-Based Hybrid Sensor for Switched Reluctance Motor Converter.

Degree: Master, Electrical Engineering, 2008, NSYSU

 The Switched Reluctance Motor (SRM) inherits a simple and reliable structure with an economical manufacturing cost. The DC power output supplies the unipolar converter to… (more)

Subjects/Keywords: Proximity sensor; Switched Reluctance Motor; Current transducer

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Chien, H. (2008). Implementation of a DSP-Based Hybrid Sensor for Switched Reluctance Motor Converter. (Thesis). NSYSU. Retrieved from http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0214108-160539

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Chien, Huang-Chen. “Implementation of a DSP-Based Hybrid Sensor for Switched Reluctance Motor Converter.” 2008. Thesis, NSYSU. Accessed September 23, 2019. http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0214108-160539.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Chien, Huang-Chen. “Implementation of a DSP-Based Hybrid Sensor for Switched Reluctance Motor Converter.” 2008. Web. 23 Sep 2019.

Vancouver:

Chien H. Implementation of a DSP-Based Hybrid Sensor for Switched Reluctance Motor Converter. [Internet] [Thesis]. NSYSU; 2008. [cited 2019 Sep 23]. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0214108-160539.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Chien H. Implementation of a DSP-Based Hybrid Sensor for Switched Reluctance Motor Converter. [Thesis]. NSYSU; 2008. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0214108-160539

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


NSYSU

20. Lai, Pei-Ying. FPGA-Based Phase-Locked-Loop Frequency-Locking Algorithm for Ultrasonic Spray Coating System.

Degree: Master, Electrical Engineering, 2016, NSYSU

 A phase-locked-loop frequency-locking algorithm implemented on an FPGA is presented for an ultrasonic spray coating system. The algorithm generates a sine wave for driving the… (more)

Subjects/Keywords: FPGA; ultrasonic transducer; phase-locked-loop

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Lai, P. (2016). FPGA-Based Phase-Locked-Loop Frequency-Locking Algorithm for Ultrasonic Spray Coating System. (Thesis). NSYSU. Retrieved from http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0026116-174014

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Lai, Pei-Ying. “FPGA-Based Phase-Locked-Loop Frequency-Locking Algorithm for Ultrasonic Spray Coating System.” 2016. Thesis, NSYSU. Accessed September 23, 2019. http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0026116-174014.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Lai, Pei-Ying. “FPGA-Based Phase-Locked-Loop Frequency-Locking Algorithm for Ultrasonic Spray Coating System.” 2016. Web. 23 Sep 2019.

Vancouver:

Lai P. FPGA-Based Phase-Locked-Loop Frequency-Locking Algorithm for Ultrasonic Spray Coating System. [Internet] [Thesis]. NSYSU; 2016. [cited 2019 Sep 23]. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0026116-174014.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Lai P. FPGA-Based Phase-Locked-Loop Frequency-Locking Algorithm for Ultrasonic Spray Coating System. [Thesis]. NSYSU; 2016. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0026116-174014

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Penn State University

21. Marston, Timothy Merrill. Infrasonic Pistonphone Calibration.

Degree: PhD, Acoustics, 2009, Penn State University

 Few options exist for calibration of transducers at infrasonic frequencies. A variable frequency infrasonic pistonphone is one option for calibration; however, thermo-viscous effects can decrease… (more)

Subjects/Keywords: Microphone; Calibration; Transducer; Acoustics; Infrasound; Pistonphone

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Marston, T. M. (2009). Infrasonic Pistonphone Calibration. (Doctoral Dissertation). Penn State University. Retrieved from https://etda.libraries.psu.edu/catalog/9345

Chicago Manual of Style (16th Edition):

Marston, Timothy Merrill. “Infrasonic Pistonphone Calibration.” 2009. Doctoral Dissertation, Penn State University. Accessed September 23, 2019. https://etda.libraries.psu.edu/catalog/9345.

MLA Handbook (7th Edition):

Marston, Timothy Merrill. “Infrasonic Pistonphone Calibration.” 2009. Web. 23 Sep 2019.

Vancouver:

Marston TM. Infrasonic Pistonphone Calibration. [Internet] [Doctoral dissertation]. Penn State University; 2009. [cited 2019 Sep 23]. Available from: https://etda.libraries.psu.edu/catalog/9345.

Council of Science Editors:

Marston TM. Infrasonic Pistonphone Calibration. [Doctoral Dissertation]. Penn State University; 2009. Available from: https://etda.libraries.psu.edu/catalog/9345


Penn State University

22. Cheng, An. A NOVEL DESIGN OF MICRO-SIZE TRANSDUCER BASED SINGLE CELL BIO-CHIP.

Degree: PhD, Engineering Science and Mechanics, 2008, Penn State University

 Cell membranes pose one of the greatest barriers to the delivery of drugs, proteins, DNA and other molecules into cells and tissues. The ability of… (more)

Subjects/Keywords: transducer; single cell; bio-chip; quantum dots

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Cheng, A. (2008). A NOVEL DESIGN OF MICRO-SIZE TRANSDUCER BASED SINGLE CELL BIO-CHIP. (Doctoral Dissertation). Penn State University. Retrieved from https://etda.libraries.psu.edu/catalog/9040

Chicago Manual of Style (16th Edition):

Cheng, An. “A NOVEL DESIGN OF MICRO-SIZE TRANSDUCER BASED SINGLE CELL BIO-CHIP.” 2008. Doctoral Dissertation, Penn State University. Accessed September 23, 2019. https://etda.libraries.psu.edu/catalog/9040.

MLA Handbook (7th Edition):

Cheng, An. “A NOVEL DESIGN OF MICRO-SIZE TRANSDUCER BASED SINGLE CELL BIO-CHIP.” 2008. Web. 23 Sep 2019.

Vancouver:

Cheng A. A NOVEL DESIGN OF MICRO-SIZE TRANSDUCER BASED SINGLE CELL BIO-CHIP. [Internet] [Doctoral dissertation]. Penn State University; 2008. [cited 2019 Sep 23]. Available from: https://etda.libraries.psu.edu/catalog/9040.

Council of Science Editors:

Cheng A. A NOVEL DESIGN OF MICRO-SIZE TRANSDUCER BASED SINGLE CELL BIO-CHIP. [Doctoral Dissertation]. Penn State University; 2008. Available from: https://etda.libraries.psu.edu/catalog/9040


Penn State University

23. THEIN, MYO MIN. Biochips Employing Microelectrodes and Microtransducers for Characterization and Permeabilization of Cell Membrane at the Whole-Cell and Cellular Level.

Degree: PhD, Engineering Science and Mechanics, 2010, Penn State University

 In this study, two types of biochips, Integrated Microelectrode Array (IMA) chip and Ultrasonic Micro–Transducer Array (UMTA) biochip, were designed and micro–fabricated. The IMA chip… (more)

Subjects/Keywords: sonoporation; microelectrode; impedance; cell membrane; biochip; transducer

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

THEIN, M. M. (2010). Biochips Employing Microelectrodes and Microtransducers for Characterization and Permeabilization of Cell Membrane at the Whole-Cell and Cellular Level. (Doctoral Dissertation). Penn State University. Retrieved from https://etda.libraries.psu.edu/catalog/11120

Chicago Manual of Style (16th Edition):

THEIN, MYO MIN. “Biochips Employing Microelectrodes and Microtransducers for Characterization and Permeabilization of Cell Membrane at the Whole-Cell and Cellular Level.” 2010. Doctoral Dissertation, Penn State University. Accessed September 23, 2019. https://etda.libraries.psu.edu/catalog/11120.

MLA Handbook (7th Edition):

THEIN, MYO MIN. “Biochips Employing Microelectrodes and Microtransducers for Characterization and Permeabilization of Cell Membrane at the Whole-Cell and Cellular Level.” 2010. Web. 23 Sep 2019.

Vancouver:

THEIN MM. Biochips Employing Microelectrodes and Microtransducers for Characterization and Permeabilization of Cell Membrane at the Whole-Cell and Cellular Level. [Internet] [Doctoral dissertation]. Penn State University; 2010. [cited 2019 Sep 23]. Available from: https://etda.libraries.psu.edu/catalog/11120.

Council of Science Editors:

THEIN MM. Biochips Employing Microelectrodes and Microtransducers for Characterization and Permeabilization of Cell Membrane at the Whole-Cell and Cellular Level. [Doctoral Dissertation]. Penn State University; 2010. Available from: https://etda.libraries.psu.edu/catalog/11120


Penn State University

24. Sherlock, Nevin Paul. RELAXOR-PT SINGLE CRYSTALS FOR BROAD BANDWIDTH, HIGH POWER SONAR PROJECTORS.

Degree: PhD, Materials Science and Engineering, 2010, Penn State University

 The high piezoelectric response of the ferroelectric relaxor (1-x)Pb(Mg1/3Nb2/3)O3-xPbTiO3 (PMNT) in single crystal form has generated significant interest in producing broad bandwidth SONAR systems. Both… (more)

Subjects/Keywords: ferroelectric; piezoelectric; single crystal; sonar; transducer

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Sherlock, N. P. (2010). RELAXOR-PT SINGLE CRYSTALS FOR BROAD BANDWIDTH, HIGH POWER SONAR PROJECTORS. (Doctoral Dissertation). Penn State University. Retrieved from https://etda.libraries.psu.edu/catalog/11397

Chicago Manual of Style (16th Edition):

Sherlock, Nevin Paul. “RELAXOR-PT SINGLE CRYSTALS FOR BROAD BANDWIDTH, HIGH POWER SONAR PROJECTORS.” 2010. Doctoral Dissertation, Penn State University. Accessed September 23, 2019. https://etda.libraries.psu.edu/catalog/11397.

MLA Handbook (7th Edition):

Sherlock, Nevin Paul. “RELAXOR-PT SINGLE CRYSTALS FOR BROAD BANDWIDTH, HIGH POWER SONAR PROJECTORS.” 2010. Web. 23 Sep 2019.

Vancouver:

Sherlock NP. RELAXOR-PT SINGLE CRYSTALS FOR BROAD BANDWIDTH, HIGH POWER SONAR PROJECTORS. [Internet] [Doctoral dissertation]. Penn State University; 2010. [cited 2019 Sep 23]. Available from: https://etda.libraries.psu.edu/catalog/11397.

Council of Science Editors:

Sherlock NP. RELAXOR-PT SINGLE CRYSTALS FOR BROAD BANDWIDTH, HIGH POWER SONAR PROJECTORS. [Doctoral Dissertation]. Penn State University; 2010. Available from: https://etda.libraries.psu.edu/catalog/11397


Penn State University

25. Shekhani, Husain Naseem. Characterization of the High Power Properties of Piezoelectric Ceramics using the Burst Method: Methodology, Analysis, and Experimental Approach.

Degree: PhD, Electrical Engineering, 2016, Penn State University

 Piezoelectric materials are used in a variety of high power applications such as ultrasonic motors and underwater sonar transducers. The properties of these materials are… (more)

Subjects/Keywords: piezoelectric; high power; PZT; ceramic; transducer

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Shekhani, H. N. (2016). Characterization of the High Power Properties of Piezoelectric Ceramics using the Burst Method: Methodology, Analysis, and Experimental Approach. (Doctoral Dissertation). Penn State University. Retrieved from https://etda.libraries.psu.edu/catalog/jm214p131

Chicago Manual of Style (16th Edition):

Shekhani, Husain Naseem. “Characterization of the High Power Properties of Piezoelectric Ceramics using the Burst Method: Methodology, Analysis, and Experimental Approach.” 2016. Doctoral Dissertation, Penn State University. Accessed September 23, 2019. https://etda.libraries.psu.edu/catalog/jm214p131.

MLA Handbook (7th Edition):

Shekhani, Husain Naseem. “Characterization of the High Power Properties of Piezoelectric Ceramics using the Burst Method: Methodology, Analysis, and Experimental Approach.” 2016. Web. 23 Sep 2019.

Vancouver:

Shekhani HN. Characterization of the High Power Properties of Piezoelectric Ceramics using the Burst Method: Methodology, Analysis, and Experimental Approach. [Internet] [Doctoral dissertation]. Penn State University; 2016. [cited 2019 Sep 23]. Available from: https://etda.libraries.psu.edu/catalog/jm214p131.

Council of Science Editors:

Shekhani HN. Characterization of the High Power Properties of Piezoelectric Ceramics using the Burst Method: Methodology, Analysis, and Experimental Approach. [Doctoral Dissertation]. Penn State University; 2016. Available from: https://etda.libraries.psu.edu/catalog/jm214p131


Delft University of Technology

26. Dannenberg, F.G.W. Symbolic dynamics and automata theory :.

Degree: 2011, Delft University of Technology

The equivalence of streams under transducers is investigated, as introduced by Klop 2011. In the process, some morphic properties of the Toeplitz words as first described by Keane are discovered. Advisors/Committee Members: Fokkink, R.J..

Subjects/Keywords: automata theory; transducer equivalence; symbolic dynamics

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Dannenberg, F. G. W. (2011). Symbolic dynamics and automata theory :. (Masters Thesis). Delft University of Technology. Retrieved from http://resolver.tudelft.nl/uuid:e7bd28eb-8fea-48ce-89c3-a2a6657f2810

Chicago Manual of Style (16th Edition):

Dannenberg, F G W. “Symbolic dynamics and automata theory :.” 2011. Masters Thesis, Delft University of Technology. Accessed September 23, 2019. http://resolver.tudelft.nl/uuid:e7bd28eb-8fea-48ce-89c3-a2a6657f2810.

MLA Handbook (7th Edition):

Dannenberg, F G W. “Symbolic dynamics and automata theory :.” 2011. Web. 23 Sep 2019.

Vancouver:

Dannenberg FGW. Symbolic dynamics and automata theory :. [Internet] [Masters thesis]. Delft University of Technology; 2011. [cited 2019 Sep 23]. Available from: http://resolver.tudelft.nl/uuid:e7bd28eb-8fea-48ce-89c3-a2a6657f2810.

Council of Science Editors:

Dannenberg FGW. Symbolic dynamics and automata theory :. [Masters Thesis]. Delft University of Technology; 2011. Available from: http://resolver.tudelft.nl/uuid:e7bd28eb-8fea-48ce-89c3-a2a6657f2810


University of Sydney

27. Miranda Jofre, Luis Alejandro. The acoustics of concentric sources and receivers – human voice and hearing applications .

Degree: 2016, University of Sydney

 One of the most common ways in which we experience environments acoustically is by listening to the reflections of our own voice in a space.… (more)

Subjects/Keywords: Acoustics; Voice; Hearing; Directivity; Concentric; Transducer Array

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Miranda Jofre, L. A. (2016). The acoustics of concentric sources and receivers – human voice and hearing applications . (Thesis). University of Sydney. Retrieved from http://hdl.handle.net/2123/15506

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Miranda Jofre, Luis Alejandro. “The acoustics of concentric sources and receivers – human voice and hearing applications .” 2016. Thesis, University of Sydney. Accessed September 23, 2019. http://hdl.handle.net/2123/15506.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Miranda Jofre, Luis Alejandro. “The acoustics of concentric sources and receivers – human voice and hearing applications .” 2016. Web. 23 Sep 2019.

Vancouver:

Miranda Jofre LA. The acoustics of concentric sources and receivers – human voice and hearing applications . [Internet] [Thesis]. University of Sydney; 2016. [cited 2019 Sep 23]. Available from: http://hdl.handle.net/2123/15506.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Miranda Jofre LA. The acoustics of concentric sources and receivers – human voice and hearing applications . [Thesis]. University of Sydney; 2016. Available from: http://hdl.handle.net/2123/15506

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Université de Bordeaux I

28. Rouge, Clémence. Modélisation du rayonnement ultrasonore par un traducteur EMAT dans une pièce ferromagnétique : Modelling of the ultrasonic field radiated by an EMAT transducer into a ferromagnetic media.

Degree: Docteur es, Mécanique, 2013, Université de Bordeaux I

Le but de la thèse est de modéliser la génération d’ondes élastiques ultrasonores émises par EMATs dans une pièce ferromagnétique, modélisation appliquée au domaine du… (more)

Subjects/Keywords: EMAT (ElectroMagnetic Acoustic Transducer); Ferromagnétisme; Contrôle non destructif; EMAT (ElectroMagnetic Acoustic Transducer); Ferromagnetism; NonDestructive Testing

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Rouge, C. (2013). Modélisation du rayonnement ultrasonore par un traducteur EMAT dans une pièce ferromagnétique : Modelling of the ultrasonic field radiated by an EMAT transducer into a ferromagnetic media. (Doctoral Dissertation). Université de Bordeaux I. Retrieved from http://www.theses.fr/2013BOR14995

Chicago Manual of Style (16th Edition):

Rouge, Clémence. “Modélisation du rayonnement ultrasonore par un traducteur EMAT dans une pièce ferromagnétique : Modelling of the ultrasonic field radiated by an EMAT transducer into a ferromagnetic media.” 2013. Doctoral Dissertation, Université de Bordeaux I. Accessed September 23, 2019. http://www.theses.fr/2013BOR14995.

MLA Handbook (7th Edition):

Rouge, Clémence. “Modélisation du rayonnement ultrasonore par un traducteur EMAT dans une pièce ferromagnétique : Modelling of the ultrasonic field radiated by an EMAT transducer into a ferromagnetic media.” 2013. Web. 23 Sep 2019.

Vancouver:

Rouge C. Modélisation du rayonnement ultrasonore par un traducteur EMAT dans une pièce ferromagnétique : Modelling of the ultrasonic field radiated by an EMAT transducer into a ferromagnetic media. [Internet] [Doctoral dissertation]. Université de Bordeaux I; 2013. [cited 2019 Sep 23]. Available from: http://www.theses.fr/2013BOR14995.

Council of Science Editors:

Rouge C. Modélisation du rayonnement ultrasonore par un traducteur EMAT dans une pièce ferromagnétique : Modelling of the ultrasonic field radiated by an EMAT transducer into a ferromagnetic media. [Doctoral Dissertation]. Université de Bordeaux I; 2013. Available from: http://www.theses.fr/2013BOR14995


University of California – Berkeley

29. Hung, Li-Wen. High-Q Low-Impedance MEMS Resonators.

Degree: Electrical Engineering & Computer Sciences, 2011, University of California – Berkeley

 The ever increasing need for regional and global roaming together with continuous advances in wireless communication standards continue to push future transceivers towards an ability… (more)

Subjects/Keywords: Electrical engineering; Mechanical engineering; Capacitive Transducer; MEMS; Piezoelectric Transducer; Resonator; Silicide; Wireless Communication

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Hung, L. (2011). High-Q Low-Impedance MEMS Resonators. (Thesis). University of California – Berkeley. Retrieved from http://www.escholarship.org/uc/item/9rr2k8c2

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Hung, Li-Wen. “High-Q Low-Impedance MEMS Resonators.” 2011. Thesis, University of California – Berkeley. Accessed September 23, 2019. http://www.escholarship.org/uc/item/9rr2k8c2.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Hung, Li-Wen. “High-Q Low-Impedance MEMS Resonators.” 2011. Web. 23 Sep 2019.

Vancouver:

Hung L. High-Q Low-Impedance MEMS Resonators. [Internet] [Thesis]. University of California – Berkeley; 2011. [cited 2019 Sep 23]. Available from: http://www.escholarship.org/uc/item/9rr2k8c2.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Hung L. High-Q Low-Impedance MEMS Resonators. [Thesis]. University of California – Berkeley; 2011. Available from: http://www.escholarship.org/uc/item/9rr2k8c2

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


KTH

30. Eghbali, Ladan. The impact of defective ultrasound transducers on the evaluation results of ultrasound imaging of blood flow.

Degree: Technology and Health (STH), 2010, KTH

  Following X-Ray, Ultrasound is now the most common of all the medical imaging technologies specifically in obstetrics and cardiology. Plus that the ultrasound hazards… (more)

Subjects/Keywords: Ultrasound; Doppler; Quality Assurance; Ultrasound Transducer; acceptance criteria; image quality; defective transducer; accurate diagnosis; Ultraljud; Doppler; kvalitetsbedömning; kvalitetssäkring; transducer; acceptanskriterier; bildkvalite; defekt ultraljudsgivare; rätt diagnos; rätt behandling

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Eghbali, L. (2010). The impact of defective ultrasound transducers on the evaluation results of ultrasound imaging of blood flow. (Thesis). KTH. Retrieved from http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-154830

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Eghbali, Ladan. “The impact of defective ultrasound transducers on the evaluation results of ultrasound imaging of blood flow.” 2010. Thesis, KTH. Accessed September 23, 2019. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-154830.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Eghbali, Ladan. “The impact of defective ultrasound transducers on the evaluation results of ultrasound imaging of blood flow.” 2010. Web. 23 Sep 2019.

Vancouver:

Eghbali L. The impact of defective ultrasound transducers on the evaluation results of ultrasound imaging of blood flow. [Internet] [Thesis]. KTH; 2010. [cited 2019 Sep 23]. Available from: http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-154830.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Eghbali L. The impact of defective ultrasound transducers on the evaluation results of ultrasound imaging of blood flow. [Thesis]. KTH; 2010. Available from: http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-154830

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

[1] [2] [3] [4] [5] … [14]

.