Advanced search options

Advanced Search Options 🞨

Browse by author name (“Author name starts with…”).

Find ETDs with:

in
/  
in
/  
in
/  
in

Written in Published in Earliest date Latest date

Sorted by

Results per page:

Sorted by: relevance · author · university · dateNew search

You searched for subject:(refrigerants). Showing records 1 – 30 of 80 total matches.

[1] [2] [3]

Search Limiters

Last 2 Years | English Only

Levels

Country

▼ Search Limiters


University of Johannesburg

1. Swanepoel, Wayne. Wet compression versus dry compression in refrigeration cycles working with pure or non-azeotropic refrigerant mixtures for air-conditioners.

Degree: 2012, University of Johannesburg

M.Ing.

Wet compression versus dry compression in refrigeration cycles working with pure refrigerants or non-azeotropic mixtures is investigated in this paper. In total 34 pure… (more)

Subjects/Keywords: Air conditioning; Refrigerants

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Swanepoel, W. (2012). Wet compression versus dry compression in refrigeration cycles working with pure or non-azeotropic refrigerant mixtures for air-conditioners. (Thesis). University of Johannesburg. Retrieved from http://hdl.handle.net/10210/6097

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Swanepoel, Wayne. “Wet compression versus dry compression in refrigeration cycles working with pure or non-azeotropic refrigerant mixtures for air-conditioners.” 2012. Thesis, University of Johannesburg. Accessed January 24, 2021. http://hdl.handle.net/10210/6097.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Swanepoel, Wayne. “Wet compression versus dry compression in refrigeration cycles working with pure or non-azeotropic refrigerant mixtures for air-conditioners.” 2012. Web. 24 Jan 2021.

Vancouver:

Swanepoel W. Wet compression versus dry compression in refrigeration cycles working with pure or non-azeotropic refrigerant mixtures for air-conditioners. [Internet] [Thesis]. University of Johannesburg; 2012. [cited 2021 Jan 24]. Available from: http://hdl.handle.net/10210/6097.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Swanepoel W. Wet compression versus dry compression in refrigeration cycles working with pure or non-azeotropic refrigerant mixtures for air-conditioners. [Thesis]. University of Johannesburg; 2012. Available from: http://hdl.handle.net/10210/6097

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Johannesburg

2. Vorster, Paul Philip Jacobus. Wet compression versus dry compression in heat pumps working with pure refrigerants or non-azeotropic mixtures for different heating applications.

Degree: 2012, University of Johannesburg

M.Ing.

Wet compression versus dry compression in heat pumps working with pure refrigerants or nonazeotropic mixtures is investigated in this paper. In total 34 pure… (more)

Subjects/Keywords: Heat pumps; Refrigerants

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Vorster, P. P. J. (2012). Wet compression versus dry compression in heat pumps working with pure refrigerants or non-azeotropic mixtures for different heating applications. (Thesis). University of Johannesburg. Retrieved from http://hdl.handle.net/10210/7627

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Vorster, Paul Philip Jacobus. “Wet compression versus dry compression in heat pumps working with pure refrigerants or non-azeotropic mixtures for different heating applications.” 2012. Thesis, University of Johannesburg. Accessed January 24, 2021. http://hdl.handle.net/10210/7627.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Vorster, Paul Philip Jacobus. “Wet compression versus dry compression in heat pumps working with pure refrigerants or non-azeotropic mixtures for different heating applications.” 2012. Web. 24 Jan 2021.

Vancouver:

Vorster PPJ. Wet compression versus dry compression in heat pumps working with pure refrigerants or non-azeotropic mixtures for different heating applications. [Internet] [Thesis]. University of Johannesburg; 2012. [cited 2021 Jan 24]. Available from: http://hdl.handle.net/10210/7627.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Vorster PPJ. Wet compression versus dry compression in heat pumps working with pure refrigerants or non-azeotropic mixtures for different heating applications. [Thesis]. University of Johannesburg; 2012. Available from: http://hdl.handle.net/10210/7627

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Hong Kong University of Science and Technology

3. Guan, Xiwen. Formulation and performance of refrigerants for moderately high temperature heat pump.

Degree: 2014, Hong Kong University of Science and Technology

 From household refrigerators and air conditioners to cooling chambers and heat pumps, refrigerants are widely used in both domestic and industrial equipments. Most of the… (more)

Subjects/Keywords: Refrigerants ; Heat pumps

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Guan, X. (2014). Formulation and performance of refrigerants for moderately high temperature heat pump. (Thesis). Hong Kong University of Science and Technology. Retrieved from http://repository.ust.hk/ir/Record/1783.1-70832 ; https://doi.org/10.14711/thesis-b1333516 ; http://repository.ust.hk/ir/bitstream/1783.1-70832/1/th_redirect.html

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Guan, Xiwen. “Formulation and performance of refrigerants for moderately high temperature heat pump.” 2014. Thesis, Hong Kong University of Science and Technology. Accessed January 24, 2021. http://repository.ust.hk/ir/Record/1783.1-70832 ; https://doi.org/10.14711/thesis-b1333516 ; http://repository.ust.hk/ir/bitstream/1783.1-70832/1/th_redirect.html.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Guan, Xiwen. “Formulation and performance of refrigerants for moderately high temperature heat pump.” 2014. Web. 24 Jan 2021.

Vancouver:

Guan X. Formulation and performance of refrigerants for moderately high temperature heat pump. [Internet] [Thesis]. Hong Kong University of Science and Technology; 2014. [cited 2021 Jan 24]. Available from: http://repository.ust.hk/ir/Record/1783.1-70832 ; https://doi.org/10.14711/thesis-b1333516 ; http://repository.ust.hk/ir/bitstream/1783.1-70832/1/th_redirect.html.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Guan X. Formulation and performance of refrigerants for moderately high temperature heat pump. [Thesis]. Hong Kong University of Science and Technology; 2014. Available from: http://repository.ust.hk/ir/Record/1783.1-70832 ; https://doi.org/10.14711/thesis-b1333516 ; http://repository.ust.hk/ir/bitstream/1783.1-70832/1/th_redirect.html

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

4. Bhramara, Panitapu. Experimental and CFD analysis of two phase flow of refrigerants inside a Horizontal tube.

Degree: 2010, Jawaharlal Nehru Technological University

In-tube two phase flow finds its applications in steam power plants, refrigeration and air conditioning, distillation and desalination units and transport of oil and slurry… (more)

Subjects/Keywords: Mechanical Engineering; Refrigerants; Fluids Model

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Bhramara, P. (2010). Experimental and CFD analysis of two phase flow of refrigerants inside a Horizontal tube. (Thesis). Jawaharlal Nehru Technological University. Retrieved from http://shodhganga.inflibnet.ac.in/handle/10603/2679

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Bhramara, Panitapu. “Experimental and CFD analysis of two phase flow of refrigerants inside a Horizontal tube.” 2010. Thesis, Jawaharlal Nehru Technological University. Accessed January 24, 2021. http://shodhganga.inflibnet.ac.in/handle/10603/2679.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Bhramara, Panitapu. “Experimental and CFD analysis of two phase flow of refrigerants inside a Horizontal tube.” 2010. Web. 24 Jan 2021.

Vancouver:

Bhramara P. Experimental and CFD analysis of two phase flow of refrigerants inside a Horizontal tube. [Internet] [Thesis]. Jawaharlal Nehru Technological University; 2010. [cited 2021 Jan 24]. Available from: http://shodhganga.inflibnet.ac.in/handle/10603/2679.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Bhramara P. Experimental and CFD analysis of two phase flow of refrigerants inside a Horizontal tube. [Thesis]. Jawaharlal Nehru Technological University; 2010. Available from: http://shodhganga.inflibnet.ac.in/handle/10603/2679

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Johannesburg

5. Smit, Floris Jakobus. Condensing coefficients of the refrigerant mixture R-22/R-142b in smooth tubes and during enhanced heat transfer configurations.

Degree: 2009, University of Johannesburg

D.Ing.

The heating of water with hot-water heat pumps is extremely energy-efficient. With the refrigerant R-22 hot water temperatures of 60° C to 65° C… (more)

Subjects/Keywords: Refrigerants; Condensation; Heat transmission

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Smit, F. J. (2009). Condensing coefficients of the refrigerant mixture R-22/R-142b in smooth tubes and during enhanced heat transfer configurations. (Thesis). University of Johannesburg. Retrieved from http://hdl.handle.net/10210/1938

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Smit, Floris Jakobus. “Condensing coefficients of the refrigerant mixture R-22/R-142b in smooth tubes and during enhanced heat transfer configurations.” 2009. Thesis, University of Johannesburg. Accessed January 24, 2021. http://hdl.handle.net/10210/1938.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Smit, Floris Jakobus. “Condensing coefficients of the refrigerant mixture R-22/R-142b in smooth tubes and during enhanced heat transfer configurations.” 2009. Web. 24 Jan 2021.

Vancouver:

Smit FJ. Condensing coefficients of the refrigerant mixture R-22/R-142b in smooth tubes and during enhanced heat transfer configurations. [Internet] [Thesis]. University of Johannesburg; 2009. [cited 2021 Jan 24]. Available from: http://hdl.handle.net/10210/1938.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Smit FJ. Condensing coefficients of the refrigerant mixture R-22/R-142b in smooth tubes and during enhanced heat transfer configurations. [Thesis]. University of Johannesburg; 2009. Available from: http://hdl.handle.net/10210/1938

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Johannesburg

6. Owaga, Denis. Flow patterns during refrigerant condensation in smooth and enhanced tubes.

Degree: 2009, University of Johannesburg

M.Ing.

The Montreal Protocol led to the phasing-out of ozone layer depleting refrigerants and replacing them with more environmentally friendly refrigerants, which in many cases… (more)

Subjects/Keywords: Refrigerants; Condensation; Heat transmission; Heat exchangers

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Owaga, D. (2009). Flow patterns during refrigerant condensation in smooth and enhanced tubes. (Thesis). University of Johannesburg. Retrieved from http://hdl.handle.net/10210/1931

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Owaga, Denis. “Flow patterns during refrigerant condensation in smooth and enhanced tubes.” 2009. Thesis, University of Johannesburg. Accessed January 24, 2021. http://hdl.handle.net/10210/1931.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Owaga, Denis. “Flow patterns during refrigerant condensation in smooth and enhanced tubes.” 2009. Web. 24 Jan 2021.

Vancouver:

Owaga D. Flow patterns during refrigerant condensation in smooth and enhanced tubes. [Internet] [Thesis]. University of Johannesburg; 2009. [cited 2021 Jan 24]. Available from: http://hdl.handle.net/10210/1931.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Owaga D. Flow patterns during refrigerant condensation in smooth and enhanced tubes. [Thesis]. University of Johannesburg; 2009. Available from: http://hdl.handle.net/10210/1931

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Johannesburg

7. Smit, Floris Jakobus. The influence of a non-azeotropic refrigerant mixture on the performance of a hot water heat pump.

Degree: 2012, University of Johannesburg

M.Ing.

The refrigerant R22, which is currently used in hot water heat pumps, delivers a maximum hot water temperature of 60 to 65 °C. This… (more)

Subjects/Keywords: Refrigerants.; Heat pumps.; Hot-water supply.

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Smit, F. J. (2012). The influence of a non-azeotropic refrigerant mixture on the performance of a hot water heat pump. (Thesis). University of Johannesburg. Retrieved from http://hdl.handle.net/10210/6802

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Smit, Floris Jakobus. “The influence of a non-azeotropic refrigerant mixture on the performance of a hot water heat pump.” 2012. Thesis, University of Johannesburg. Accessed January 24, 2021. http://hdl.handle.net/10210/6802.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Smit, Floris Jakobus. “The influence of a non-azeotropic refrigerant mixture on the performance of a hot water heat pump.” 2012. Web. 24 Jan 2021.

Vancouver:

Smit FJ. The influence of a non-azeotropic refrigerant mixture on the performance of a hot water heat pump. [Internet] [Thesis]. University of Johannesburg; 2012. [cited 2021 Jan 24]. Available from: http://hdl.handle.net/10210/6802.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Smit FJ. The influence of a non-azeotropic refrigerant mixture on the performance of a hot water heat pump. [Thesis]. University of Johannesburg; 2012. Available from: http://hdl.handle.net/10210/6802

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Cranfield University

8. Augood, P. C. Low-temperature thermal-energy storage and transmission systems employing hydrophilic polymeric materials.

Degree: PhD, 1997, Cranfield University

 The wide fluctuations that occur in the aggregate electrical demand of a generating utility are punitive with respect to total system efficiency. Demand side management… (more)

Subjects/Keywords: 536.7; Slurries; Refrigerants

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Augood, P. C. (1997). Low-temperature thermal-energy storage and transmission systems employing hydrophilic polymeric materials. (Doctoral Dissertation). Cranfield University. Retrieved from http://dspace.lib.cranfield.ac.uk/handle/1826/4517 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.359962

Chicago Manual of Style (16th Edition):

Augood, P C. “Low-temperature thermal-energy storage and transmission systems employing hydrophilic polymeric materials.” 1997. Doctoral Dissertation, Cranfield University. Accessed January 24, 2021. http://dspace.lib.cranfield.ac.uk/handle/1826/4517 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.359962.

MLA Handbook (7th Edition):

Augood, P C. “Low-temperature thermal-energy storage and transmission systems employing hydrophilic polymeric materials.” 1997. Web. 24 Jan 2021.

Vancouver:

Augood PC. Low-temperature thermal-energy storage and transmission systems employing hydrophilic polymeric materials. [Internet] [Doctoral dissertation]. Cranfield University; 1997. [cited 2021 Jan 24]. Available from: http://dspace.lib.cranfield.ac.uk/handle/1826/4517 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.359962.

Council of Science Editors:

Augood PC. Low-temperature thermal-energy storage and transmission systems employing hydrophilic polymeric materials. [Doctoral Dissertation]. Cranfield University; 1997. Available from: http://dspace.lib.cranfield.ac.uk/handle/1826/4517 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.359962


University of Victoria

9. Rowe, Andrew Michael. Active magnetic regenerators: performance in the vicinity of para-ferromagnetic second order phase transitions.

Degree: Department of Mechanical Engineering, 2018, University of Victoria

 A technology that has the potential to liquefy hydrogen and natural gas efficiently is an Active Magnetic Regenerative Liquefier (AMRL). An AMRL exploits the magnetocaloric… (more)

Subjects/Keywords: Refrigerants; Superconducting magnets; Regenerators; Phase transitions

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Rowe, A. M. (2018). Active magnetic regenerators: performance in the vicinity of para-ferromagnetic second order phase transitions. (Thesis). University of Victoria. Retrieved from https://dspace.library.uvic.ca//handle/1828/10248

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Rowe, Andrew Michael. “Active magnetic regenerators: performance in the vicinity of para-ferromagnetic second order phase transitions.” 2018. Thesis, University of Victoria. Accessed January 24, 2021. https://dspace.library.uvic.ca//handle/1828/10248.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Rowe, Andrew Michael. “Active magnetic regenerators: performance in the vicinity of para-ferromagnetic second order phase transitions.” 2018. Web. 24 Jan 2021.

Vancouver:

Rowe AM. Active magnetic regenerators: performance in the vicinity of para-ferromagnetic second order phase transitions. [Internet] [Thesis]. University of Victoria; 2018. [cited 2021 Jan 24]. Available from: https://dspace.library.uvic.ca//handle/1828/10248.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Rowe AM. Active magnetic regenerators: performance in the vicinity of para-ferromagnetic second order phase transitions. [Thesis]. University of Victoria; 2018. Available from: https://dspace.library.uvic.ca//handle/1828/10248

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Illinois – Urbana-Champaign

10. Mishra, Surya P. Tribological studies of surface texturing for application in air-conditioning and refrigeration compressors.

Degree: MS, 0133, 2011, University of Illinois – Urbana-Champaign

 Operating conditions such as load and speed of compressors are getting more aggressive to improve efficiency. Also, protection from beneficial surface layers, such as ferrous… (more)

Subjects/Keywords: Surface texturing; Compressor tribology; Environmentally friendly refrigerants

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Mishra, S. P. (2011). Tribological studies of surface texturing for application in air-conditioning and refrigeration compressors. (Thesis). University of Illinois – Urbana-Champaign. Retrieved from http://hdl.handle.net/2142/26123

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Mishra, Surya P. “Tribological studies of surface texturing for application in air-conditioning and refrigeration compressors.” 2011. Thesis, University of Illinois – Urbana-Champaign. Accessed January 24, 2021. http://hdl.handle.net/2142/26123.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Mishra, Surya P. “Tribological studies of surface texturing for application in air-conditioning and refrigeration compressors.” 2011. Web. 24 Jan 2021.

Vancouver:

Mishra SP. Tribological studies of surface texturing for application in air-conditioning and refrigeration compressors. [Internet] [Thesis]. University of Illinois – Urbana-Champaign; 2011. [cited 2021 Jan 24]. Available from: http://hdl.handle.net/2142/26123.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Mishra SP. Tribological studies of surface texturing for application in air-conditioning and refrigeration compressors. [Thesis]. University of Illinois – Urbana-Champaign; 2011. Available from: http://hdl.handle.net/2142/26123

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Northeastern University

11. Aljohani, Bassam S. Performance assessment of vapor compression systems utilizing low global warming potential hydrocarbons and carbon dioxide as working fluids.

Degree: MS, Department of Mechanical and Industrial Engineering, 2018, Northeastern University

 The air conditioning (AC) refrigerants such as chlorofluorocarbons (CFC) as well as hydrofluorocarbons (HFC) have been major factor affecting on the global warming. These harmful… (more)

Subjects/Keywords: carbon dioxide; hydrocarbons; low global warming potentials refrigerants; refrigerants; refrigeration system; vapor compression system

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Aljohani, B. S. (2018). Performance assessment of vapor compression systems utilizing low global warming potential hydrocarbons and carbon dioxide as working fluids. (Masters Thesis). Northeastern University. Retrieved from http://hdl.handle.net/2047/D20292869

Chicago Manual of Style (16th Edition):

Aljohani, Bassam S. “Performance assessment of vapor compression systems utilizing low global warming potential hydrocarbons and carbon dioxide as working fluids.” 2018. Masters Thesis, Northeastern University. Accessed January 24, 2021. http://hdl.handle.net/2047/D20292869.

MLA Handbook (7th Edition):

Aljohani, Bassam S. “Performance assessment of vapor compression systems utilizing low global warming potential hydrocarbons and carbon dioxide as working fluids.” 2018. Web. 24 Jan 2021.

Vancouver:

Aljohani BS. Performance assessment of vapor compression systems utilizing low global warming potential hydrocarbons and carbon dioxide as working fluids. [Internet] [Masters thesis]. Northeastern University; 2018. [cited 2021 Jan 24]. Available from: http://hdl.handle.net/2047/D20292869.

Council of Science Editors:

Aljohani BS. Performance assessment of vapor compression systems utilizing low global warming potential hydrocarbons and carbon dioxide as working fluids. [Masters Thesis]. Northeastern University; 2018. Available from: http://hdl.handle.net/2047/D20292869


NSYSU

12. Hsiao, Yu-Lung. Optimal Simulation and Analysis of the Refrigerant R-600a Applied to an Air-Conditioning System.

Degree: Master, Mechanical and Electro-Mechanical Engineering, 2002, NSYSU

 The optimizations of air-condition systems using naturalrefrigerants R-600a are studied in this thesis. The theories including the exergy analysis, heat transfer and fluid mechanics are… (more)

Subjects/Keywords: natural refrigerants; refrigerationcycle; optimization

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Hsiao, Y. (2002). Optimal Simulation and Analysis of the Refrigerant R-600a Applied to an Air-Conditioning System. (Thesis). NSYSU. Retrieved from http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0710102-132227

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Hsiao, Yu-Lung. “Optimal Simulation and Analysis of the Refrigerant R-600a Applied to an Air-Conditioning System.” 2002. Thesis, NSYSU. Accessed January 24, 2021. http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0710102-132227.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Hsiao, Yu-Lung. “Optimal Simulation and Analysis of the Refrigerant R-600a Applied to an Air-Conditioning System.” 2002. Web. 24 Jan 2021.

Vancouver:

Hsiao Y. Optimal Simulation and Analysis of the Refrigerant R-600a Applied to an Air-Conditioning System. [Internet] [Thesis]. NSYSU; 2002. [cited 2021 Jan 24]. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0710102-132227.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Hsiao Y. Optimal Simulation and Analysis of the Refrigerant R-600a Applied to an Air-Conditioning System. [Thesis]. NSYSU; 2002. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0710102-132227

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Johannesburg

13. Kebonte, Shiko A. Condensation heat transfer and pressure drop coefficients of R22/R142b in a water cooled helicaly coiled tube-in-tube heat exchanger.

Degree: 2012, University of Johannesburg

M.Ing.

Heat transfer and pressure drop characteristics during in-tube condensation of nonazeotropic mixtures of R22/R142b in a smooth helically coiled copper tube with an inside… (more)

Subjects/Keywords: Heat exchangers - Fluid dynamics; Heat - Transmission; Refrigerants; Condensation

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Kebonte, S. A. (2012). Condensation heat transfer and pressure drop coefficients of R22/R142b in a water cooled helicaly coiled tube-in-tube heat exchanger. (Thesis). University of Johannesburg. Retrieved from http://hdl.handle.net/10210/6181

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Kebonte, Shiko A. “Condensation heat transfer and pressure drop coefficients of R22/R142b in a water cooled helicaly coiled tube-in-tube heat exchanger.” 2012. Thesis, University of Johannesburg. Accessed January 24, 2021. http://hdl.handle.net/10210/6181.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Kebonte, Shiko A. “Condensation heat transfer and pressure drop coefficients of R22/R142b in a water cooled helicaly coiled tube-in-tube heat exchanger.” 2012. Web. 24 Jan 2021.

Vancouver:

Kebonte SA. Condensation heat transfer and pressure drop coefficients of R22/R142b in a water cooled helicaly coiled tube-in-tube heat exchanger. [Internet] [Thesis]. University of Johannesburg; 2012. [cited 2021 Jan 24]. Available from: http://hdl.handle.net/10210/6181.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Kebonte SA. Condensation heat transfer and pressure drop coefficients of R22/R142b in a water cooled helicaly coiled tube-in-tube heat exchanger. [Thesis]. University of Johannesburg; 2012. Available from: http://hdl.handle.net/10210/6181

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Johannesburg

14. Lambrechts, Adriaan. Heat transfer performance during in-tube condensation in horizontal smooth, micro-fin and herringbone tubes.

Degree: 2008, University of Johannesburg

M.Ing.

An experimental investigation was conducted into the heat transfer characteristics of horizontal smooth, micro-fin and herringbone tubes during in-tube condensation. The study focused on… (more)

Subjects/Keywords: Heat transmission; Condensation; Refrigerants

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Lambrechts, A. (2008). Heat transfer performance during in-tube condensation in horizontal smooth, micro-fin and herringbone tubes. (Thesis). University of Johannesburg. Retrieved from http://hdl.handle.net/10210/1753

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Lambrechts, Adriaan. “Heat transfer performance during in-tube condensation in horizontal smooth, micro-fin and herringbone tubes.” 2008. Thesis, University of Johannesburg. Accessed January 24, 2021. http://hdl.handle.net/10210/1753.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Lambrechts, Adriaan. “Heat transfer performance during in-tube condensation in horizontal smooth, micro-fin and herringbone tubes.” 2008. Web. 24 Jan 2021.

Vancouver:

Lambrechts A. Heat transfer performance during in-tube condensation in horizontal smooth, micro-fin and herringbone tubes. [Internet] [Thesis]. University of Johannesburg; 2008. [cited 2021 Jan 24]. Available from: http://hdl.handle.net/10210/1753.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Lambrechts A. Heat transfer performance during in-tube condensation in horizontal smooth, micro-fin and herringbone tubes. [Thesis]. University of Johannesburg; 2008. Available from: http://hdl.handle.net/10210/1753

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Lithuanian University of Agriculture

15. Jakštas, Edgaras. Šaldymo įrangos naudojimo saugos tyrimas.

Degree: Master, Mechanical Engineering, 2011, Lithuanian University of Agriculture

Darbo tikslas – ištirti įvairių veiksnių įtaką šaldymo įrangos naudojimo saugai. Dirbant su šaldymo įranga susiduriama su potencialiai pavojinga įranga ir pavojingomis cheminėmis medžiagomis, todėl… (more)

Subjects/Keywords: Šaltnešiai; Pavojingos medžiagos; Rizika; Prevencija; Refrigerants; Dangerous substances; Risk; Prevention

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Jakštas, Edgaras. (2011). Šaldymo įrangos naudojimo saugos tyrimas. (Masters Thesis). Lithuanian University of Agriculture. Retrieved from http://vddb.laba.lt/obj/LT-eLABa-0001:E.02~2011~D_20110602_120541-38308 ;

Note: this citation may be lacking information needed for this citation format:
Author name may be incomplete

Chicago Manual of Style (16th Edition):

Jakštas, Edgaras. “Šaldymo įrangos naudojimo saugos tyrimas.” 2011. Masters Thesis, Lithuanian University of Agriculture. Accessed January 24, 2021. http://vddb.laba.lt/obj/LT-eLABa-0001:E.02~2011~D_20110602_120541-38308 ;.

Note: this citation may be lacking information needed for this citation format:
Author name may be incomplete

MLA Handbook (7th Edition):

Jakštas, Edgaras. “Šaldymo įrangos naudojimo saugos tyrimas.” 2011. Web. 24 Jan 2021.

Note: this citation may be lacking information needed for this citation format:
Author name may be incomplete

Vancouver:

Jakštas, Edgaras. Šaldymo įrangos naudojimo saugos tyrimas. [Internet] [Masters thesis]. Lithuanian University of Agriculture; 2011. [cited 2021 Jan 24]. Available from: http://vddb.laba.lt/obj/LT-eLABa-0001:E.02~2011~D_20110602_120541-38308 ;.

Note: this citation may be lacking information needed for this citation format:
Author name may be incomplete

Council of Science Editors:

Jakštas, Edgaras. Šaldymo įrangos naudojimo saugos tyrimas. [Masters Thesis]. Lithuanian University of Agriculture; 2011. Available from: http://vddb.laba.lt/obj/LT-eLABa-0001:E.02~2011~D_20110602_120541-38308 ;

Note: this citation may be lacking information needed for this citation format:
Author name may be incomplete


University of Adelaide

16. Au, Edwin C.F. A computational scheme for calculating refrigerant properties & heat transfer in boiling tube flow.

Degree: 1999, University of Adelaide

 This study aims to develop a computational scheme (AuCFD) for calculating refrigerant properties, two-phase heat transfer coefficients and pressure drop of R12 and R134a in… (more)

Subjects/Keywords: Heat  – Transmission Refrigerants Thermodynamics

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Au, E. C. F. (1999). A computational scheme for calculating refrigerant properties & heat transfer in boiling tube flow. (Thesis). University of Adelaide. Retrieved from http://hdl.handle.net/2440/120373

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Au, Edwin C F. “A computational scheme for calculating refrigerant properties & heat transfer in boiling tube flow.” 1999. Thesis, University of Adelaide. Accessed January 24, 2021. http://hdl.handle.net/2440/120373.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Au, Edwin C F. “A computational scheme for calculating refrigerant properties & heat transfer in boiling tube flow.” 1999. Web. 24 Jan 2021.

Vancouver:

Au ECF. A computational scheme for calculating refrigerant properties & heat transfer in boiling tube flow. [Internet] [Thesis]. University of Adelaide; 1999. [cited 2021 Jan 24]. Available from: http://hdl.handle.net/2440/120373.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Au ECF. A computational scheme for calculating refrigerant properties & heat transfer in boiling tube flow. [Thesis]. University of Adelaide; 1999. Available from: http://hdl.handle.net/2440/120373

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Colorado

17. Coolidge, Collin Jennings. Low Pressure Ratio Cascaded Joule-Thomson Cryogenic Coolers.

Degree: PhD, 2017, University of Colorado

 This thesis presents the design, fabrication, and characterization of several coldstages intended to investigate the feasibility of a low pressure ratio three stage cascaded Joule-Thomson… (more)

Subjects/Keywords: cryogenic coolers; refrigerants; coldstage; Joule-Thomson; Mechanical Engineering

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Coolidge, C. J. (2017). Low Pressure Ratio Cascaded Joule-Thomson Cryogenic Coolers. (Doctoral Dissertation). University of Colorado. Retrieved from https://scholar.colorado.edu/mcen_gradetds/138

Chicago Manual of Style (16th Edition):

Coolidge, Collin Jennings. “Low Pressure Ratio Cascaded Joule-Thomson Cryogenic Coolers.” 2017. Doctoral Dissertation, University of Colorado. Accessed January 24, 2021. https://scholar.colorado.edu/mcen_gradetds/138.

MLA Handbook (7th Edition):

Coolidge, Collin Jennings. “Low Pressure Ratio Cascaded Joule-Thomson Cryogenic Coolers.” 2017. Web. 24 Jan 2021.

Vancouver:

Coolidge CJ. Low Pressure Ratio Cascaded Joule-Thomson Cryogenic Coolers. [Internet] [Doctoral dissertation]. University of Colorado; 2017. [cited 2021 Jan 24]. Available from: https://scholar.colorado.edu/mcen_gradetds/138.

Council of Science Editors:

Coolidge CJ. Low Pressure Ratio Cascaded Joule-Thomson Cryogenic Coolers. [Doctoral Dissertation]. University of Colorado; 2017. Available from: https://scholar.colorado.edu/mcen_gradetds/138


University of Victoria

18. Peksoy, Ozan. Demagnetizing effects in active magnetic regenerators.

Degree: Dept. of Mechanical Engineering, 2008, University of Victoria

Subjects/Keywords: Refrigerants; Refrigeration and refrigerating machinery

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Peksoy, O. (2008). Demagnetizing effects in active magnetic regenerators. (Thesis). University of Victoria. Retrieved from http://hdl.handle.net/1828/413

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Peksoy, Ozan. “Demagnetizing effects in active magnetic regenerators.” 2008. Thesis, University of Victoria. Accessed January 24, 2021. http://hdl.handle.net/1828/413.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Peksoy, Ozan. “Demagnetizing effects in active magnetic regenerators.” 2008. Web. 24 Jan 2021.

Vancouver:

Peksoy O. Demagnetizing effects in active magnetic regenerators. [Internet] [Thesis]. University of Victoria; 2008. [cited 2021 Jan 24]. Available from: http://hdl.handle.net/1828/413.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Peksoy O. Demagnetizing effects in active magnetic regenerators. [Thesis]. University of Victoria; 2008. Available from: http://hdl.handle.net/1828/413

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

19. Mort, Katherine Ann. The liquid structure of haloalkanes.

Degree: PhD, 1998, University of Liverpool

Subjects/Keywords: 547; Liquid benzene; Refrigerants

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Mort, K. A. (1998). The liquid structure of haloalkanes. (Doctoral Dissertation). University of Liverpool. Retrieved from https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.263872

Chicago Manual of Style (16th Edition):

Mort, Katherine Ann. “The liquid structure of haloalkanes.” 1998. Doctoral Dissertation, University of Liverpool. Accessed January 24, 2021. https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.263872.

MLA Handbook (7th Edition):

Mort, Katherine Ann. “The liquid structure of haloalkanes.” 1998. Web. 24 Jan 2021.

Vancouver:

Mort KA. The liquid structure of haloalkanes. [Internet] [Doctoral dissertation]. University of Liverpool; 1998. [cited 2021 Jan 24]. Available from: https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.263872.

Council of Science Editors:

Mort KA. The liquid structure of haloalkanes. [Doctoral Dissertation]. University of Liverpool; 1998. Available from: https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.263872


Michigan State University

20. Lindberg, Bruce Ernest. Enabling technology for the use of R718 in a vapor-compression refrigeration cycle.

Degree: MS, Mechanical Engineering, 2009, Michigan State University

Subjects/Keywords: Refrigerants – Economic aspects; Refrigerants – Environmental aspects; Water; Air conditioning; Vapor density

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Lindberg, B. E. (2009). Enabling technology for the use of R718 in a vapor-compression refrigeration cycle. (Masters Thesis). Michigan State University. Retrieved from http://etd.lib.msu.edu/islandora/object/etd:17389

Chicago Manual of Style (16th Edition):

Lindberg, Bruce Ernest. “Enabling technology for the use of R718 in a vapor-compression refrigeration cycle.” 2009. Masters Thesis, Michigan State University. Accessed January 24, 2021. http://etd.lib.msu.edu/islandora/object/etd:17389.

MLA Handbook (7th Edition):

Lindberg, Bruce Ernest. “Enabling technology for the use of R718 in a vapor-compression refrigeration cycle.” 2009. Web. 24 Jan 2021.

Vancouver:

Lindberg BE. Enabling technology for the use of R718 in a vapor-compression refrigeration cycle. [Internet] [Masters thesis]. Michigan State University; 2009. [cited 2021 Jan 24]. Available from: http://etd.lib.msu.edu/islandora/object/etd:17389.

Council of Science Editors:

Lindberg BE. Enabling technology for the use of R718 in a vapor-compression refrigeration cycle. [Masters Thesis]. Michigan State University; 2009. Available from: http://etd.lib.msu.edu/islandora/object/etd:17389


Brno University of Technology

21. Kotas, Marek. Větrání a chlazení administrativního objektu: Ventilation and cooling of administrative building.

Degree: 2019, Brno University of Technology

 The Bachelor thesis introduces a design of ventilation and air-conditioning equipment for an administrative building. The function of the device is to create a high-quality… (more)

Subjects/Keywords: Vzduchotechnika; chlazení; klimatizace; administrativní objekt; interní mikroklima; chladiva; životní prostředí; regulace chladiv.; Ventilation; cooling; air-conditioning; administrative building; internal microclimate; refrigerants; environment; regulation of refrigerants.

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Kotas, M. (2019). Větrání a chlazení administrativního objektu: Ventilation and cooling of administrative building. (Thesis). Brno University of Technology. Retrieved from http://hdl.handle.net/11012/179699

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Kotas, Marek. “Větrání a chlazení administrativního objektu: Ventilation and cooling of administrative building.” 2019. Thesis, Brno University of Technology. Accessed January 24, 2021. http://hdl.handle.net/11012/179699.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Kotas, Marek. “Větrání a chlazení administrativního objektu: Ventilation and cooling of administrative building.” 2019. Web. 24 Jan 2021.

Vancouver:

Kotas M. Větrání a chlazení administrativního objektu: Ventilation and cooling of administrative building. [Internet] [Thesis]. Brno University of Technology; 2019. [cited 2021 Jan 24]. Available from: http://hdl.handle.net/11012/179699.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Kotas M. Větrání a chlazení administrativního objektu: Ventilation and cooling of administrative building. [Thesis]. Brno University of Technology; 2019. Available from: http://hdl.handle.net/11012/179699

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

22. Cunha, Amélia Cristina Ferreira. Cafeína, apetite e sono.

Degree: 2013, Universidade Fernando Pessoa

Projeto de Pós-Graduação/Dissertação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Ciências Farmacêuticas

O presente trabalho foca… (more)

Subjects/Keywords: Apetite; Café; Cafeína; Chocolate; Exercício físico; Refrigerantes; Sono; Appetite; Caffeine; Chocolate; Coffee; Exercise; Refrigerants; Sleep

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Cunha, A. C. F. (2013). Cafeína, apetite e sono. (Thesis). Universidade Fernando Pessoa. Retrieved from http://www.rcaap.pt/detail.jsp?id=oai:bdigital.ufp.pt:10284/4088

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Cunha, Amélia Cristina Ferreira. “Cafeína, apetite e sono.” 2013. Thesis, Universidade Fernando Pessoa. Accessed January 24, 2021. http://www.rcaap.pt/detail.jsp?id=oai:bdigital.ufp.pt:10284/4088.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Cunha, Amélia Cristina Ferreira. “Cafeína, apetite e sono.” 2013. Web. 24 Jan 2021.

Vancouver:

Cunha ACF. Cafeína, apetite e sono. [Internet] [Thesis]. Universidade Fernando Pessoa; 2013. [cited 2021 Jan 24]. Available from: http://www.rcaap.pt/detail.jsp?id=oai:bdigital.ufp.pt:10284/4088.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Cunha ACF. Cafeína, apetite e sono. [Thesis]. Universidade Fernando Pessoa; 2013. Available from: http://www.rcaap.pt/detail.jsp?id=oai:bdigital.ufp.pt:10284/4088

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


NSYSU

23. Wu, Chun-Yi. Simulation and Analysis of the Characteristics of Thermal Fliuid Cycles for natural refrigerants R-600a and R-290 applying to an air-conditioning system.

Degree: Master, Mechanical Engineering, 2000, NSYSU

 The characteristics of thermofluid flow cycle for natural refrigerants R-600a and R-290 applying to an air-conditioning system are studied in this project. In system performance… (more)

Subjects/Keywords: air-conditioning system; optimized; natural refrigerants

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Wu, C. (2000). Simulation and Analysis of the Characteristics of Thermal Fliuid Cycles for natural refrigerants R-600a and R-290 applying to an air-conditioning system. (Thesis). NSYSU. Retrieved from http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0706100-094850

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Wu, Chun-Yi. “Simulation and Analysis of the Characteristics of Thermal Fliuid Cycles for natural refrigerants R-600a and R-290 applying to an air-conditioning system.” 2000. Thesis, NSYSU. Accessed January 24, 2021. http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0706100-094850.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Wu, Chun-Yi. “Simulation and Analysis of the Characteristics of Thermal Fliuid Cycles for natural refrigerants R-600a and R-290 applying to an air-conditioning system.” 2000. Web. 24 Jan 2021.

Vancouver:

Wu C. Simulation and Analysis of the Characteristics of Thermal Fliuid Cycles for natural refrigerants R-600a and R-290 applying to an air-conditioning system. [Internet] [Thesis]. NSYSU; 2000. [cited 2021 Jan 24]. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0706100-094850.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Wu C. Simulation and Analysis of the Characteristics of Thermal Fliuid Cycles for natural refrigerants R-600a and R-290 applying to an air-conditioning system. [Thesis]. NSYSU; 2000. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0706100-094850

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

24. Rebelo, Rui Miguel Pinto Torres. Uso de Fluidos Naturais em Sistemas de Refrigeração e Ar Condicionado.

Degree: 2017, Instituto Politécnico do Porto

 O signatário da tese trabalhou aproximadamente oito anos em assistência técnica e manutenção em sistemas de AVAC&R (Aquecimento Ventilação e Ar Condicionado & Refrigeração) sendo… (more)

Subjects/Keywords: Fluidos Frigorigéneos; Dióxido de Carbono; Refrigeração; Ar Condicionado; Refrigerants; Carbon dioxide; Refrigeration; Air Conditioning

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Rebelo, R. M. P. T. (2017). Uso de Fluidos Naturais em Sistemas de Refrigeração e Ar Condicionado. (Thesis). Instituto Politécnico do Porto. Retrieved from https://www.rcaap.pt/detail.jsp?id=oai:recipp.ipp.pt:10400.22/10402

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Rebelo, Rui Miguel Pinto Torres. “Uso de Fluidos Naturais em Sistemas de Refrigeração e Ar Condicionado.” 2017. Thesis, Instituto Politécnico do Porto. Accessed January 24, 2021. https://www.rcaap.pt/detail.jsp?id=oai:recipp.ipp.pt:10400.22/10402.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Rebelo, Rui Miguel Pinto Torres. “Uso de Fluidos Naturais em Sistemas de Refrigeração e Ar Condicionado.” 2017. Web. 24 Jan 2021.

Vancouver:

Rebelo RMPT. Uso de Fluidos Naturais em Sistemas de Refrigeração e Ar Condicionado. [Internet] [Thesis]. Instituto Politécnico do Porto; 2017. [cited 2021 Jan 24]. Available from: https://www.rcaap.pt/detail.jsp?id=oai:recipp.ipp.pt:10400.22/10402.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Rebelo RMPT. Uso de Fluidos Naturais em Sistemas de Refrigeração e Ar Condicionado. [Thesis]. Instituto Politécnico do Porto; 2017. Available from: https://www.rcaap.pt/detail.jsp?id=oai:recipp.ipp.pt:10400.22/10402

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Michigan

25. Kim, Youngil. Generalized equation of state for refrigerants with applications.

Degree: PhD, Mechanical engineering, 1993, University of Michigan

 Recent studies have indicated that chlorofluorocarbon compounds that are widely used as refrigerants in vapor-compression refrigeration cycles and as propellants are the major suspect to… (more)

Subjects/Keywords: Applications; Equation; Generalized; Of; Refrigerants; State

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Kim, Y. (1993). Generalized equation of state for refrigerants with applications. (Doctoral Dissertation). University of Michigan. Retrieved from http://hdl.handle.net/2027.42/129071

Chicago Manual of Style (16th Edition):

Kim, Youngil. “Generalized equation of state for refrigerants with applications.” 1993. Doctoral Dissertation, University of Michigan. Accessed January 24, 2021. http://hdl.handle.net/2027.42/129071.

MLA Handbook (7th Edition):

Kim, Youngil. “Generalized equation of state for refrigerants with applications.” 1993. Web. 24 Jan 2021.

Vancouver:

Kim Y. Generalized equation of state for refrigerants with applications. [Internet] [Doctoral dissertation]. University of Michigan; 1993. [cited 2021 Jan 24]. Available from: http://hdl.handle.net/2027.42/129071.

Council of Science Editors:

Kim Y. Generalized equation of state for refrigerants with applications. [Doctoral Dissertation]. University of Michigan; 1993. Available from: http://hdl.handle.net/2027.42/129071

26. Parag, Dadeech. Impact of alternative refrigerants on evaporator design and analysis of compact heat exchangers.

Degree: 1995, University of Tennessee – Chattanooga

 This thesis deals with the evaluation of the impact of alternate refrigerants on the thermal design parameters of different heat exchangers, such as, plate fin… (more)

Subjects/Keywords: Heat exchangers  – Thermodynamics; Refrigerants  – Thermal properties

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Parag, D. (1995). Impact of alternative refrigerants on evaporator design and analysis of compact heat exchangers. (Masters Thesis). University of Tennessee – Chattanooga. Retrieved from LB2369.2 .D334 1995 ; https://scholar.utc.edu/theses/676

Chicago Manual of Style (16th Edition):

Parag, Dadeech. “Impact of alternative refrigerants on evaporator design and analysis of compact heat exchangers.” 1995. Masters Thesis, University of Tennessee – Chattanooga. Accessed January 24, 2021. LB2369.2 .D334 1995 ; https://scholar.utc.edu/theses/676.

MLA Handbook (7th Edition):

Parag, Dadeech. “Impact of alternative refrigerants on evaporator design and analysis of compact heat exchangers.” 1995. Web. 24 Jan 2021.

Vancouver:

Parag D. Impact of alternative refrigerants on evaporator design and analysis of compact heat exchangers. [Internet] [Masters thesis]. University of Tennessee – Chattanooga; 1995. [cited 2021 Jan 24]. Available from: LB2369.2 .D334 1995 ; https://scholar.utc.edu/theses/676.

Council of Science Editors:

Parag D. Impact of alternative refrigerants on evaporator design and analysis of compact heat exchangers. [Masters Thesis]. University of Tennessee – Chattanooga; 1995. Available from: LB2369.2 .D334 1995 ; https://scholar.utc.edu/theses/676


Purdue University

27. Dharkar, Supriya. CO2 HEAT PUMPS FOR COMMERCIAL BUILDING APPLICATIONS WITH SIMULTANEOUS HEATING AND COOLING DEMAND.

Degree: MSME, Mechanical Engineering, 2015, Purdue University

 Many commercial buildings, including data centers, hotels and hospitals, have a simultaneous heating and cooling demand depending on the season, occupation and auxiliary equipment. A… (more)

Subjects/Keywords: Data Centers; Energy; Environment; Heat Pumps; Natural Refrigerants; Simultaneous Heating and Cooling

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Dharkar, S. (2015). CO2 HEAT PUMPS FOR COMMERCIAL BUILDING APPLICATIONS WITH SIMULTANEOUS HEATING AND COOLING DEMAND. (Thesis). Purdue University. Retrieved from https://docs.lib.purdue.edu/open_access_theses/1104

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Dharkar, Supriya. “CO2 HEAT PUMPS FOR COMMERCIAL BUILDING APPLICATIONS WITH SIMULTANEOUS HEATING AND COOLING DEMAND.” 2015. Thesis, Purdue University. Accessed January 24, 2021. https://docs.lib.purdue.edu/open_access_theses/1104.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Dharkar, Supriya. “CO2 HEAT PUMPS FOR COMMERCIAL BUILDING APPLICATIONS WITH SIMULTANEOUS HEATING AND COOLING DEMAND.” 2015. Web. 24 Jan 2021.

Vancouver:

Dharkar S. CO2 HEAT PUMPS FOR COMMERCIAL BUILDING APPLICATIONS WITH SIMULTANEOUS HEATING AND COOLING DEMAND. [Internet] [Thesis]. Purdue University; 2015. [cited 2021 Jan 24]. Available from: https://docs.lib.purdue.edu/open_access_theses/1104.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Dharkar S. CO2 HEAT PUMPS FOR COMMERCIAL BUILDING APPLICATIONS WITH SIMULTANEOUS HEATING AND COOLING DEMAND. [Thesis]. Purdue University; 2015. Available from: https://docs.lib.purdue.edu/open_access_theses/1104

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Johannesburg

28. Liebenberg, Leon. A unified prediction method for smooth and micro-fin tube condensation performance.

Degree: 2009, University of Johannesburg

D.Ing.

Subjects/Keywords: Heat transmission; Heat exchangers; Condensation; Refrigerants

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Liebenberg, L. (2009). A unified prediction method for smooth and micro-fin tube condensation performance. (Thesis). University of Johannesburg. Retrieved from http://hdl.handle.net/10210/1939

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Liebenberg, Leon. “A unified prediction method for smooth and micro-fin tube condensation performance.” 2009. Thesis, University of Johannesburg. Accessed January 24, 2021. http://hdl.handle.net/10210/1939.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Liebenberg, Leon. “A unified prediction method for smooth and micro-fin tube condensation performance.” 2009. Web. 24 Jan 2021.

Vancouver:

Liebenberg L. A unified prediction method for smooth and micro-fin tube condensation performance. [Internet] [Thesis]. University of Johannesburg; 2009. [cited 2021 Jan 24]. Available from: http://hdl.handle.net/10210/1939.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Liebenberg L. A unified prediction method for smooth and micro-fin tube condensation performance. [Thesis]. University of Johannesburg; 2009. Available from: http://hdl.handle.net/10210/1939

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

29. Spearing, Ian Gregory. Improving the refrigeration and gas liquefaction performance of Gifford-McMahon and active magnetic regenerative cryocoolers: a study of flow maldistribution, unbalance, and asymmetry.

Degree: Department of Mechanical Engineering, 2018, University of Victoria

 Cost-effective liquefaction of gases at cryogenic temperatures requires a combined approach of designing efficient refrigeration cycles to generate cooling capacity and designing efficient liquefaction processes… (more)

Subjects/Keywords: Refrigeration and refrigerating machinery; Refrigerants

Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Spearing, I. G. (2018). Improving the refrigeration and gas liquefaction performance of Gifford-McMahon and active magnetic regenerative cryocoolers: a study of flow maldistribution, unbalance, and asymmetry. (Thesis). University of Victoria. Retrieved from https://dspace.library.uvic.ca//handle/1828/9859

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Spearing, Ian Gregory. “Improving the refrigeration and gas liquefaction performance of Gifford-McMahon and active magnetic regenerative cryocoolers: a study of flow maldistribution, unbalance, and asymmetry.” 2018. Thesis, University of Victoria. Accessed January 24, 2021. https://dspace.library.uvic.ca//handle/1828/9859.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Spearing, Ian Gregory. “Improving the refrigeration and gas liquefaction performance of Gifford-McMahon and active magnetic regenerative cryocoolers: a study of flow maldistribution, unbalance, and asymmetry.” 2018. Web. 24 Jan 2021.

Vancouver:

Spearing IG. Improving the refrigeration and gas liquefaction performance of Gifford-McMahon and active magnetic regenerative cryocoolers: a study of flow maldistribution, unbalance, and asymmetry. [Internet] [Thesis]. University of Victoria; 2018. [cited 2021 Jan 24]. Available from: https://dspace.library.uvic.ca//handle/1828/9859.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Spearing IG. Improving the refrigeration and gas liquefaction performance of Gifford-McMahon and active magnetic regenerative cryocoolers: a study of flow maldistribution, unbalance, and asymmetry. [Thesis]. University of Victoria; 2018. Available from: https://dspace.library.uvic.ca//handle/1828/9859

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of KwaZulu-Natal

30. Ngema, Peterson Thokozani. Hydrate technology for the concentration of aqueous salt solutions using fluorinated refrigerants.

Degree: 2019, University of KwaZulu-Natal

 The world is facing a challenge with the scarcity of fresh water, due to an increase in the world population and the large expansion of… (more)

Subjects/Keywords: Desalination.; Wastewater.; Seawater.; Refrigerants.; Gas hydrate technology.; Water purification systems.; Water scarcity.

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Ngema, P. T. (2019). Hydrate technology for the concentration of aqueous salt solutions using fluorinated refrigerants. (Thesis). University of KwaZulu-Natal. Retrieved from https://researchspace.ukzn.ac.za/handle/10413/18670

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Ngema, Peterson Thokozani. “Hydrate technology for the concentration of aqueous salt solutions using fluorinated refrigerants.” 2019. Thesis, University of KwaZulu-Natal. Accessed January 24, 2021. https://researchspace.ukzn.ac.za/handle/10413/18670.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Ngema, Peterson Thokozani. “Hydrate technology for the concentration of aqueous salt solutions using fluorinated refrigerants.” 2019. Web. 24 Jan 2021.

Vancouver:

Ngema PT. Hydrate technology for the concentration of aqueous salt solutions using fluorinated refrigerants. [Internet] [Thesis]. University of KwaZulu-Natal; 2019. [cited 2021 Jan 24]. Available from: https://researchspace.ukzn.ac.za/handle/10413/18670.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Ngema PT. Hydrate technology for the concentration of aqueous salt solutions using fluorinated refrigerants. [Thesis]. University of KwaZulu-Natal; 2019. Available from: https://researchspace.ukzn.ac.za/handle/10413/18670

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

[1] [2] [3]

.