Advanced search options

Advanced Search Options 🞨

Browse by author name (“Author name starts with…”).

Find ETDs with:

in
/  
in
/  
in
/  
in

Written in Published in Earliest date Latest date

Sorted by

Results per page:

Sorted by: relevance · author · university · dateNew search

You searched for subject:(iodine 123). Showing records 1 – 3 of 3 total matches.

Search Limiters

Last 2 Years | English Only

No search limiters apply to these results.

▼ Search Limiters

1. Catanoso, Marcela Forli. Purificação de 123I e 131I para  marcação de biomoléculas.

Degree: Mestrado, Tecnologia Nuclear - Aplicações, 2011, University of São Paulo

O 123I e 131I são dois radioisótopos de iodo amplamente utilizados em medicina nuclear. O 123I é utilizado para diagnóstico através da técnica de SPECT e produzido no IPEN em cíclotron a partir da reação 124Xe (p,2n)123Cs->123Xe-> 123I. Já o 131I pode ser utilizado tanto para o diagnóstico quanto para o tratamento devido às suas características físicas de decaimento β- e sua elevada emissão de raios-γ. Sua produção no IPEN é realizada utilizando um reator nuclear a partir da reação indireta: 130Te(n, γ)->131Te->131I, onde são irradiados alvos contendo Te. Os radiofármacos preparados com estes radioisótopos passam por um rigoroso controle de qualidade onde a pureza química dos radioisótopos primários 123I e 131I está dentro dos limites estabelecidos atualmente. Entretanto, a presença de alguns contaminantes químicos prejudica a marcação de biomoléculas (anticorpos monoclonais e peptídeos) que produziriam radiofármacos de primeira geração para a área de oncologia. Com isso, o objetivo deste trabalho consiste na obtenção de um método de purificação dos radionuclídeos 123I e 131I para uma maior eficiência na marcação de biomoléculas, estabelecendo também controle do processo nos métodos de produção destes radioisótopos. A metodologia foi dividida em 3 etapas: Determinação da pureza radionuclídica através da análise de amostras de 123I e 131I no detector de germânio-hiperpuro (HPGe), determinação da pureza química de 123I e 131I através da técnica de ICP-OES e análise do comportamento de 131I em diversos adsorvedores para posterior utilização dos adsorvedores mais adequados para os testes de purificação, analisando o comportamento dos possíveis contaminantes. Quanto a pureza radionuclídica, pode-se observar a presença de radionuclídeos de Te e Co nas amostras de 131I e radionuclídeos de Te, Tc e Co para 123I. A análise de pureza química determinou a presença principalmente de Al e Mo nas amostras de 123I, provenientes do material do porta-alvo e da janela do porta-alvo e Al e Te nas amostras de 131I, provenientes da cápsula de Al utilizada na irradiação e do alvo, respectivamente. O estudo de retenção e eluição de 131I selecionou os meios adsorvedores mais promissores para sua purificação, no caso a resina catiônica Dowex 50WX4 que apresentou excelente eluição de 131I e retenção das impurezas radionuclídicas presentes em sua solução.

The 123I and 131I are iodine radioisotopes widely used in Nuclear Medicine. The radioisotope 123I is used in diagnosis through the SPECT technique and is routinely produced at IPEN in cyclotron through the reaction: 124Xe (p, 2n) 123Cs -> 123Xe -> 123I. The radioisotope 131I is used both in diagnosis and therapy due to its physical characteristics of decay by β- and its γ-ray emissions that are softened with the use of specific collimators for diagnosis. It is routinely produced at IPEN using the nuclear reactor through the indirect reaction: 130Te (n, γ) ->131Te -> 131I, irradiating compounds containing Te. The radiopharmaceuticals prepared with these…

Advisors/Committee Members: Osso Júnior, João Alberto.

Subjects/Keywords: iodine-123; iodine-131; iodo-123; iodo-131; purificação; purification; radiofarmácia; radiopharmacy

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Catanoso, M. F. (2011). Purificação de 123I e 131I para  marcação de biomoléculas. (Masters Thesis). University of São Paulo. Retrieved from http://www.teses.usp.br/teses/disponiveis/85/85131/tde-15092011-144958/ ;

Chicago Manual of Style (16th Edition):

Catanoso, Marcela Forli. “Purificação de 123I e 131I para  marcação de biomoléculas.” 2011. Masters Thesis, University of São Paulo. Accessed July 07, 2020. http://www.teses.usp.br/teses/disponiveis/85/85131/tde-15092011-144958/ ;.

MLA Handbook (7th Edition):

Catanoso, Marcela Forli. “Purificação de 123I e 131I para  marcação de biomoléculas.” 2011. Web. 07 Jul 2020.

Vancouver:

Catanoso MF. Purificação de 123I e 131I para  marcação de biomoléculas. [Internet] [Masters thesis]. University of São Paulo; 2011. [cited 2020 Jul 07]. Available from: http://www.teses.usp.br/teses/disponiveis/85/85131/tde-15092011-144958/ ;.

Council of Science Editors:

Catanoso MF. Purificação de 123I e 131I para  marcação de biomoléculas. [Masters Thesis]. University of São Paulo; 2011. Available from: http://www.teses.usp.br/teses/disponiveis/85/85131/tde-15092011-144958/ ;

2. Sumiya, Luiz Carlos do Amaral. Estudo de parâmetros relevantes na irradiação de 124-Xe, visando a otimização na obtenção de 123-I ultra puro no Ciclotron Cyclone-30 do IPEN-CNEN/SP.

Degree: PhD, Tecnologia Nuclear - Aplicações, 2006, University of São Paulo

O desenvolvimento da Medicina Nuclear, aliado à evolução dos equipamentos de diagnóstico e terapia, necessita, cada vez mais, da disponibilidade comercial de radioisótopos. Nesse contexto, o IPEN tem buscado atender e abastecer o mercado nacional. Um dos investimentos nesta área foi a aquisição de um ciclotron de 30 MeV, modelo Cyclone-30, que permitiu a produção dos radioisótopos tais como, o 18F, 67Ga, 201Tl e o 123I, sendo este último o foco do presente trabalho. Através de dados de produções rotineiras de 123I via irradiação com prótons em alvo gasoso de Xenônio com enriquecimento superior a 99,8% em 124Xe, foi realizado um estudo para identificar os fatores relevantes que influenciam diretamente o rendimento de obtenção de 123I com altíssimo grau de pureza. Embora a metodologia seja bem conhecida, quando se trata de produção comercial há uma escassez de dados sobre os parâmetros operacionais utilizados. Os parâmetros avaliados foram: pressão do gás 124Xe, intensidade de corrente de feixe de prótons, tempo de irradiação, temperatura de operação do sistema durante a irradiação, tempo de espera para formação de 123I, tempo de aquecimento do porta-alvo para recuperação do 123I formado, temperatura de aquecimento da solução de lavagem e influência do revestimento interno da câmara de irradiação com Ni. Com os resultados obtidos, foi possível alterar as condições operacionais nas produções rotineiras, conduzindo a um aumento de eficiência do processo em torno de 30%.

The development of diagnosis equipment and therapy procedures in nuclear medicine depends on the availability of commercial radioisotopes. IPEN is the most important institution that provides radioisotopes for national market. In order to achieve this function, IPEN had invested in the acquisition of a 30 MeV Cyclone-30 cyclotron to produce mainly 18F, 67Ga, 201Tl and 123I. The 123I production is the aim of the present work. With the 123I routine production data obtained by proton irradiation of Xe targets with an enrichment greater than 99.8%, it was possible to identify the important parameters that have direct influence on the production yield of high purity degree 123I. Even though the methodology for the commercial production of 123I, there are an scarcity of operational parameters data for this task. In this work the evaluated parameters were: 124Xe pressure, proton beam quality, irradiation time, operational temperature of the irradiation system under irradiation, waiting time to obtain 123I, temperature of washing solution and the impact of the internal Ni coating in the target. With the obtained results it was possible to modify the operational conditions for routine production and increasing the efficiency in about 30%.

Advisors/Committee Members: Sciani, Valdir.

Subjects/Keywords: 123I; 124Xe; I-123; iodo ultra puro; produção de I-123; production of 123I; pure extreme iodine; radioisótopo de ciclotron; radioisotopo of cyclotron; Xe-124

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Sumiya, L. C. d. A. (2006). Estudo de parâmetros relevantes na irradiação de 124-Xe, visando a otimização na obtenção de 123-I ultra puro no Ciclotron Cyclone-30 do IPEN-CNEN/SP. (Doctoral Dissertation). University of São Paulo. Retrieved from http://www.teses.usp.br/teses/disponiveis/85/85131/tde-06062007-164028/ ;

Chicago Manual of Style (16th Edition):

Sumiya, Luiz Carlos do Amaral. “Estudo de parâmetros relevantes na irradiação de 124-Xe, visando a otimização na obtenção de 123-I ultra puro no Ciclotron Cyclone-30 do IPEN-CNEN/SP.” 2006. Doctoral Dissertation, University of São Paulo. Accessed July 07, 2020. http://www.teses.usp.br/teses/disponiveis/85/85131/tde-06062007-164028/ ;.

MLA Handbook (7th Edition):

Sumiya, Luiz Carlos do Amaral. “Estudo de parâmetros relevantes na irradiação de 124-Xe, visando a otimização na obtenção de 123-I ultra puro no Ciclotron Cyclone-30 do IPEN-CNEN/SP.” 2006. Web. 07 Jul 2020.

Vancouver:

Sumiya LCdA. Estudo de parâmetros relevantes na irradiação de 124-Xe, visando a otimização na obtenção de 123-I ultra puro no Ciclotron Cyclone-30 do IPEN-CNEN/SP. [Internet] [Doctoral dissertation]. University of São Paulo; 2006. [cited 2020 Jul 07]. Available from: http://www.teses.usp.br/teses/disponiveis/85/85131/tde-06062007-164028/ ;.

Council of Science Editors:

Sumiya LCdA. Estudo de parâmetros relevantes na irradiação de 124-Xe, visando a otimização na obtenção de 123-I ultra puro no Ciclotron Cyclone-30 do IPEN-CNEN/SP. [Doctoral Dissertation]. University of São Paulo; 2006. Available from: http://www.teses.usp.br/teses/disponiveis/85/85131/tde-06062007-164028/ ;


Georgia Tech

3. Jangha, Desiree Nicole. Quantitative Conjugate Imaging of Iodine-123 and Technetium-99m Labeled Brain Agents in the Basal Ganglia.

Degree: PhD, Health Physics, 2006, Georgia Tech

In the research reported in this dissertation, the concept of classic conjugate imaging, a non-tomographic nuclear medicine technique, is modified such that activity of a radiopharmaceutical distribution in the striata can be estimated. A mathematical model is developed that extended the application of classic conjugate imaging to estimation of two distinct and aligned activity distributions. Error analysis of the mathematical model is performed to characterize the accuracy of the model and to benchmark the limitations of the model. Phantom experiments are performed to demonstrate the practical application of the model and to evaluate its accuracy. A Monte Carlo simulation model of conjugate imaging of activity uptake in the striata of a primate is developed to evaluate the accuracy of the modified conjugate imaging technique as applied in the use of a dedicate conjugate imaging system. In addition, the simulation model is used to determine and characterize the shielding design of the small field of view gamma cameras comprising the dedicated conjugate imaging system. The application of scatter correction is investigated to address the downscatter of high-energy photon emissions into the photopeak window and the inclusion of scattered primary photons in the photopeak window. In this dissertation, it is shown that the modified conjugate imaging technique developed can be used to estimate accurately activity uptake in each of two distinct and aligned activity distributions. The accuracy of the technique is shown to be comparable to that of clinical quantitative SPECT. The modified conjugate imaging technique used with the dedicated conjugate imaging system may, therefore, be a viable quantitative nuclear medicine technique for activity estimation of radiopharmaceutical uptake in the striata of Parkinsonian and schizophrenic patients. The portability and low cost relative to SPECT systems make a dedicated conjugate imaging system advantageous for clinics with Parkinsonian and schizophrenic patients, who are unable to travel due to physical or mental limitation. Advisors/Committee Members: Aarsvold, John N. (Committee Co-Chair), Wang, C K Chris (Committee Co-Chair), Benkeser, Paul J. (Committee Member), Hertel, Nolan (Committee Member), Rahnema, Farzad (Committee Member).

Subjects/Keywords: Technetium-99m; Iodine-123; Parkinson's disease; Conjugate imaging; Striata; Planar imaging; Technetium; Technetium compounds

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Jangha, D. N. (2006). Quantitative Conjugate Imaging of Iodine-123 and Technetium-99m Labeled Brain Agents in the Basal Ganglia. (Doctoral Dissertation). Georgia Tech. Retrieved from http://hdl.handle.net/1853/11589

Chicago Manual of Style (16th Edition):

Jangha, Desiree Nicole. “Quantitative Conjugate Imaging of Iodine-123 and Technetium-99m Labeled Brain Agents in the Basal Ganglia.” 2006. Doctoral Dissertation, Georgia Tech. Accessed July 07, 2020. http://hdl.handle.net/1853/11589.

MLA Handbook (7th Edition):

Jangha, Desiree Nicole. “Quantitative Conjugate Imaging of Iodine-123 and Technetium-99m Labeled Brain Agents in the Basal Ganglia.” 2006. Web. 07 Jul 2020.

Vancouver:

Jangha DN. Quantitative Conjugate Imaging of Iodine-123 and Technetium-99m Labeled Brain Agents in the Basal Ganglia. [Internet] [Doctoral dissertation]. Georgia Tech; 2006. [cited 2020 Jul 07]. Available from: http://hdl.handle.net/1853/11589.

Council of Science Editors:

Jangha DN. Quantitative Conjugate Imaging of Iodine-123 and Technetium-99m Labeled Brain Agents in the Basal Ganglia. [Doctoral Dissertation]. Georgia Tech; 2006. Available from: http://hdl.handle.net/1853/11589

.