Advanced search options

Advanced Search Options 🞨

Browse by author name (“Author name starts with…”).

Find ETDs with:

in
/  
in
/  
in
/  
in

Written in Published in Earliest date Latest date

Sorted by

Results per page:

Sorted by: relevance · author · university · dateNew search

You searched for subject:(flexural plate wave). Showing records 1 – 16 of 16 total matches.

Search Limiters

Last 2 Years | English Only

No search limiters apply to these results.

▼ Search Limiters


NSYSU

1. Hsu, Chia-Hao. Development of High-sensitivity Flexural Plate-wave Based Tetrahydrocannabinol Biosensor.

Degree: Master, Electrical Engineering, 2016, NSYSU

 According to the World Drugs Report 2016 released by the United Nations, It is estimated that 1 in 20 adults, or a quarter of a… (more)

Subjects/Keywords: flexural plate-wave; Tetrahydrocannabinol; insertion loss; double electrode interdigital transducers

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Hsu, C. (2016). Development of High-sensitivity Flexural Plate-wave Based Tetrahydrocannabinol Biosensor. (Thesis). NSYSU. Retrieved from http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0731116-092257

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Hsu, Chia-Hao. “Development of High-sensitivity Flexural Plate-wave Based Tetrahydrocannabinol Biosensor.” 2016. Thesis, NSYSU. Accessed November 22, 2019. http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0731116-092257.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Hsu, Chia-Hao. “Development of High-sensitivity Flexural Plate-wave Based Tetrahydrocannabinol Biosensor.” 2016. Web. 22 Nov 2019.

Vancouver:

Hsu C. Development of High-sensitivity Flexural Plate-wave Based Tetrahydrocannabinol Biosensor. [Internet] [Thesis]. NSYSU; 2016. [cited 2019 Nov 22]. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0731116-092257.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Hsu C. Development of High-sensitivity Flexural Plate-wave Based Tetrahydrocannabinol Biosensor. [Thesis]. NSYSU; 2016. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0731116-092257

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


NSYSU

2. Lin, Ji-Yuan. Development of Flexural Plate-wave Device with Focused Interdigital Transducers Design.

Degree: Master, Electrical Engineering, 2012, NSYSU

 The conventional flexural plate-wave (FPW) device has advantages of high mass sensitivity, low phase velocity and low operation frequency. However, conventional FPW devices usually present… (more)

Subjects/Keywords: microsensor; bulk micromachining; inter-digital transducers; insertion loss; flexural plate-wave

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Lin, J. (2012). Development of Flexural Plate-wave Device with Focused Interdigital Transducers Design. (Thesis). NSYSU. Retrieved from http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0731112-123300

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Lin, Ji-Yuan. “Development of Flexural Plate-wave Device with Focused Interdigital Transducers Design.” 2012. Thesis, NSYSU. Accessed November 22, 2019. http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0731112-123300.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Lin, Ji-Yuan. “Development of Flexural Plate-wave Device with Focused Interdigital Transducers Design.” 2012. Web. 22 Nov 2019.

Vancouver:

Lin J. Development of Flexural Plate-wave Device with Focused Interdigital Transducers Design. [Internet] [Thesis]. NSYSU; 2012. [cited 2019 Nov 22]. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0731112-123300.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Lin J. Development of Flexural Plate-wave Device with Focused Interdigital Transducers Design. [Thesis]. NSYSU; 2012. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0731112-123300

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Brunel University

3. Kossovich, Elena. Explicit models for flexural edge and interfacial waves in thin elastic plates.

Degree: PhD, 2011, Brunel University

 In the thesis explicit dual parabolic-elliptic models are constructed for the Konenkov flexural edge wave and the Stoneley-type flexural interfacial wave in case of thin… (more)

Subjects/Keywords: 515.983; Explicit dual parabolic-elliptic models; Konenkov flexural edge wave; Stoneley-type flexural interfacial wave; Kirchhoff plate theory; Deflection

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Kossovich, E. (2011). Explicit models for flexural edge and interfacial waves in thin elastic plates. (Doctoral Dissertation). Brunel University. Retrieved from http://bura.brunel.ac.uk/handle/2438/6505 ; https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.557749

Chicago Manual of Style (16th Edition):

Kossovich, Elena. “Explicit models for flexural edge and interfacial waves in thin elastic plates.” 2011. Doctoral Dissertation, Brunel University. Accessed November 22, 2019. http://bura.brunel.ac.uk/handle/2438/6505 ; https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.557749.

MLA Handbook (7th Edition):

Kossovich, Elena. “Explicit models for flexural edge and interfacial waves in thin elastic plates.” 2011. Web. 22 Nov 2019.

Vancouver:

Kossovich E. Explicit models for flexural edge and interfacial waves in thin elastic plates. [Internet] [Doctoral dissertation]. Brunel University; 2011. [cited 2019 Nov 22]. Available from: http://bura.brunel.ac.uk/handle/2438/6505 ; https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.557749.

Council of Science Editors:

Kossovich E. Explicit models for flexural edge and interfacial waves in thin elastic plates. [Doctoral Dissertation]. Brunel University; 2011. Available from: http://bura.brunel.ac.uk/handle/2438/6505 ; https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.557749


NSYSU

4. Hsieh, Han-Yueh. Investigation of the Influence of the Geometries and Structures of Interdigital Transducers and Reflective Grating Structures on Flexural Plate-wave based Prostatic Specific Antigen Biosensor.

Degree: Master, Electrical Engineering, 2017, NSYSU

 According to the report of Health Promotion Administration, Ministry of Health and Welfare, prostate cancer is the sixth leading cause of cancer death in Taiwanese… (more)

Subjects/Keywords: Insertion Loss; PSA-biosensors; Self-assembled Monolayers; Bulk Micromachining; Flexural Plate-wave

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Hsieh, H. (2017). Investigation of the Influence of the Geometries and Structures of Interdigital Transducers and Reflective Grating Structures on Flexural Plate-wave based Prostatic Specific Antigen Biosensor. (Thesis). NSYSU. Retrieved from http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0714117-184303

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Hsieh, Han-Yueh. “Investigation of the Influence of the Geometries and Structures of Interdigital Transducers and Reflective Grating Structures on Flexural Plate-wave based Prostatic Specific Antigen Biosensor.” 2017. Thesis, NSYSU. Accessed November 22, 2019. http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0714117-184303.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Hsieh, Han-Yueh. “Investigation of the Influence of the Geometries and Structures of Interdigital Transducers and Reflective Grating Structures on Flexural Plate-wave based Prostatic Specific Antigen Biosensor.” 2017. Web. 22 Nov 2019.

Vancouver:

Hsieh H. Investigation of the Influence of the Geometries and Structures of Interdigital Transducers and Reflective Grating Structures on Flexural Plate-wave based Prostatic Specific Antigen Biosensor. [Internet] [Thesis]. NSYSU; 2017. [cited 2019 Nov 22]. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0714117-184303.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Hsieh H. Investigation of the Influence of the Geometries and Structures of Interdigital Transducers and Reflective Grating Structures on Flexural Plate-wave based Prostatic Specific Antigen Biosensor. [Thesis]. NSYSU; 2017. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0714117-184303

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


NSYSU

5. Chen, Jian-Lin. Development of Flexural Plate-wave Device with a Focused Reflective Grating Structure.

Degree: Master, Electrical Engineering, 2013, NSYSU

 Acoustic micro-sensors have already been applied in mass sensing including surface acoustic wave (SAW), thickness shear mode (TSM), shear horizontal acoustic plate mode (SH-APM) and… (more)

Subjects/Keywords: focus-type reflective grating structure; insertion loss; microsensor; bulk micromachining; flexural plate-wave

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Chen, J. (2013). Development of Flexural Plate-wave Device with a Focused Reflective Grating Structure. (Thesis). NSYSU. Retrieved from http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0722113-124503

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Chen, Jian-Lin. “Development of Flexural Plate-wave Device with a Focused Reflective Grating Structure.” 2013. Thesis, NSYSU. Accessed November 22, 2019. http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0722113-124503.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Chen, Jian-Lin. “Development of Flexural Plate-wave Device with a Focused Reflective Grating Structure.” 2013. Web. 22 Nov 2019.

Vancouver:

Chen J. Development of Flexural Plate-wave Device with a Focused Reflective Grating Structure. [Internet] [Thesis]. NSYSU; 2013. [cited 2019 Nov 22]. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0722113-124503.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Chen J. Development of Flexural Plate-wave Device with a Focused Reflective Grating Structure. [Thesis]. NSYSU; 2013. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0722113-124503

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


NSYSU

6. Lyu, Guan-dong. Development of a Low Insertion Loss Flexural Plate-wave Sensor Using Circular-arc Interdigital Transducers Design.

Degree: Master, Electrical Engineering, 2015, NSYSU

 Acoustic micro-sensors have already been applied in mass sensing including surface acoustic wave (SAW), thickness shear mode (TSM), shear horizontal acoustic plate mode (SH-APM) and… (more)

Subjects/Keywords: circular-arc interdigital transducers; insertion loss; flexural plate-wave; microsensor; bulk micromachining

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Lyu, G. (2015). Development of a Low Insertion Loss Flexural Plate-wave Sensor Using Circular-arc Interdigital Transducers Design. (Thesis). NSYSU. Retrieved from http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0026115-110441

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Lyu, Guan-dong. “Development of a Low Insertion Loss Flexural Plate-wave Sensor Using Circular-arc Interdigital Transducers Design.” 2015. Thesis, NSYSU. Accessed November 22, 2019. http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0026115-110441.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Lyu, Guan-dong. “Development of a Low Insertion Loss Flexural Plate-wave Sensor Using Circular-arc Interdigital Transducers Design.” 2015. Web. 22 Nov 2019.

Vancouver:

Lyu G. Development of a Low Insertion Loss Flexural Plate-wave Sensor Using Circular-arc Interdigital Transducers Design. [Internet] [Thesis]. NSYSU; 2015. [cited 2019 Nov 22]. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0026115-110441.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Lyu G. Development of a Low Insertion Loss Flexural Plate-wave Sensor Using Circular-arc Interdigital Transducers Design. [Thesis]. NSYSU; 2015. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0026115-110441

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


NSYSU

7. Tang, Chih-Yi. Development of a High-sensitivity Flexural Plate-wave Based Biosensor for Carcinoembryonic Antigen Detection.

Degree: Master, Electrical Engineering, 2016, NSYSU

 According to the World Cancer Report 2014 by the International Agency for Research on Cancer (IARC), the global number of cases of colorectal cancer increased… (more)

Subjects/Keywords: CEA-biosensors; Bulk Micromachining; Self-Assembled Monolayers; SAMs; flexural plate-wave; Insertion Loss

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Tang, C. (2016). Development of a High-sensitivity Flexural Plate-wave Based Biosensor for Carcinoembryonic Antigen Detection. (Thesis). NSYSU. Retrieved from http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0731116-092305

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Tang, Chih-Yi. “Development of a High-sensitivity Flexural Plate-wave Based Biosensor for Carcinoembryonic Antigen Detection.” 2016. Thesis, NSYSU. Accessed November 22, 2019. http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0731116-092305.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Tang, Chih-Yi. “Development of a High-sensitivity Flexural Plate-wave Based Biosensor for Carcinoembryonic Antigen Detection.” 2016. Web. 22 Nov 2019.

Vancouver:

Tang C. Development of a High-sensitivity Flexural Plate-wave Based Biosensor for Carcinoembryonic Antigen Detection. [Internet] [Thesis]. NSYSU; 2016. [cited 2019 Nov 22]. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0731116-092305.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Tang C. Development of a High-sensitivity Flexural Plate-wave Based Biosensor for Carcinoembryonic Antigen Detection. [Thesis]. NSYSU; 2016. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0731116-092305

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


NSYSU

8. Hsu, Li-Han. Development of Flexural Plate-wave Device with Silicon Trench Reflective Grating Structure.

Degree: Master, Electrical Engineering, 2012, NSYSU

 Abstract Compared with the other micro acoustic wave devices, the flexural plate-wave (FPW) device is more suitable for being used in liquid-sensing applications due to… (more)

Subjects/Keywords: flexural plate-wave; silicon-trench reflective grating structure; electromechanical coupling coefficient; ZnO; bulk micromachining technology

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Hsu, L. (2012). Development of Flexural Plate-wave Device with Silicon Trench Reflective Grating Structure. (Thesis). NSYSU. Retrieved from http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0730112-180344

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Hsu, Li-Han. “Development of Flexural Plate-wave Device with Silicon Trench Reflective Grating Structure.” 2012. Thesis, NSYSU. Accessed November 22, 2019. http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0730112-180344.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Hsu, Li-Han. “Development of Flexural Plate-wave Device with Silicon Trench Reflective Grating Structure.” 2012. Web. 22 Nov 2019.

Vancouver:

Hsu L. Development of Flexural Plate-wave Device with Silicon Trench Reflective Grating Structure. [Internet] [Thesis]. NSYSU; 2012. [cited 2019 Nov 22]. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0730112-180344.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Hsu L. Development of Flexural Plate-wave Device with Silicon Trench Reflective Grating Structure. [Thesis]. NSYSU; 2012. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0730112-180344

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


NSYSU

9. Lee, Ming-Chih. Development of a Flexural Plateâwave Allergy Biosensor by MEMS Technology.

Degree: PhD, Electrical Engineering, 2012, NSYSU

 Utilizing self-assembled monolayer nanotechnology, micro-electro-mechanical systems (MEMS) and IC technologies, a novel flexural plate-wave (FPW) biosensor is developed in this dissertation for detecting the immunoglobulin-E… (more)

Subjects/Keywords: self-assembled monolayer; immunoglobulin-E; point-of-care testing; MEMS; flexural plate-wave; biosensor

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Lee, M. (2012). Development of a Flexural Plateâwave Allergy Biosensor by MEMS Technology. (Doctoral Dissertation). NSYSU. Retrieved from http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0816112-013336

Chicago Manual of Style (16th Edition):

Lee, Ming-Chih. “Development of a Flexural Plateâwave Allergy Biosensor by MEMS Technology.” 2012. Doctoral Dissertation, NSYSU. Accessed November 22, 2019. http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0816112-013336.

MLA Handbook (7th Edition):

Lee, Ming-Chih. “Development of a Flexural Plateâwave Allergy Biosensor by MEMS Technology.” 2012. Web. 22 Nov 2019.

Vancouver:

Lee M. Development of a Flexural Plateâwave Allergy Biosensor by MEMS Technology. [Internet] [Doctoral dissertation]. NSYSU; 2012. [cited 2019 Nov 22]. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0816112-013336.

Council of Science Editors:

Lee M. Development of a Flexural Plateâwave Allergy Biosensor by MEMS Technology. [Doctoral Dissertation]. NSYSU; 2012. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0816112-013336


NSYSU

10. Lin, Yain-Reu. Low Power Half-Run RC5 Cipher Circuit for Portable Biomedical Device and A Frequency-Shift Readout Circuit for FPW-Based Biosensors.

Degree: Master, Electrical Engineering, 2011, NSYSU

 This thesis consists of two topics. We proposed a low power half-run RC5 cipher for portable biomedical devices in the first part of this thesis.… (more)

Subjects/Keywords: frequency-shift readout system; RC5; flexural plate wave; biomedical system; low power; ZigBee

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Lin, Y. (2011). Low Power Half-Run RC5 Cipher Circuit for Portable Biomedical Device and A Frequency-Shift Readout Circuit for FPW-Based Biosensors. (Thesis). NSYSU. Retrieved from http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0808111-162539

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Lin, Yain-Reu. “Low Power Half-Run RC5 Cipher Circuit for Portable Biomedical Device and A Frequency-Shift Readout Circuit for FPW-Based Biosensors.” 2011. Thesis, NSYSU. Accessed November 22, 2019. http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0808111-162539.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Lin, Yain-Reu. “Low Power Half-Run RC5 Cipher Circuit for Portable Biomedical Device and A Frequency-Shift Readout Circuit for FPW-Based Biosensors.” 2011. Web. 22 Nov 2019.

Vancouver:

Lin Y. Low Power Half-Run RC5 Cipher Circuit for Portable Biomedical Device and A Frequency-Shift Readout Circuit for FPW-Based Biosensors. [Internet] [Thesis]. NSYSU; 2011. [cited 2019 Nov 22]. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0808111-162539.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Lin Y. Low Power Half-Run RC5 Cipher Circuit for Portable Biomedical Device and A Frequency-Shift Readout Circuit for FPW-Based Biosensors. [Thesis]. NSYSU; 2011. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0808111-162539

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


NSYSU

11. James, Chang. Development of FPW Device with Groove Reflection Structure Design.

Degree: Master, Electrical Engineering, 2011, NSYSU

 Utilizing bulk micromachining technology, this thesis aimed to develop a flexural plate-wave(FPW) device with novel groove reflection microstructure for high-sensitivity and low insertion-loss biomedical microsystem… (more)

Subjects/Keywords: ZnO piezoelectric thin-film; insertion-loss; groove reflection microstructure; flexural plate-wave; electrochemical etch-stop

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

James, C. (2011). Development of FPW Device with Groove Reflection Structure Design. (Thesis). NSYSU. Retrieved from http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0906111-004231

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

James, Chang. “Development of FPW Device with Groove Reflection Structure Design.” 2011. Thesis, NSYSU. Accessed November 22, 2019. http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0906111-004231.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

James, Chang. “Development of FPW Device with Groove Reflection Structure Design.” 2011. Web. 22 Nov 2019.

Vancouver:

James C. Development of FPW Device with Groove Reflection Structure Design. [Internet] [Thesis]. NSYSU; 2011. [cited 2019 Nov 22]. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0906111-004231.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

James C. Development of FPW Device with Groove Reflection Structure Design. [Thesis]. NSYSU; 2011. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0906111-004231

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


NSYSU

12. Su, Pei-jin. Development of a Flexural Plate-wave Based Alpha-fetoprotein Biosensor with High Performances and Fabrication Yield.

Degree: Master, Electrical Engineering, 2015, NSYSU

 According to the 2014 annual report of Health Promotion Administration (Ministry of Health and Welfare, Taiwan), the hepatocellular carcinoma (HCC) has become the second major… (more)

Subjects/Keywords: flexural plate-wave; MEMS; high fabrication yield; AFP-biosensor; self-assembly monolayer

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Su, P. (2015). Development of a Flexural Plate-wave Based Alpha-fetoprotein Biosensor with High Performances and Fabrication Yield. (Thesis). NSYSU. Retrieved from http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0717115-140159

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Su, Pei-jin. “Development of a Flexural Plate-wave Based Alpha-fetoprotein Biosensor with High Performances and Fabrication Yield.” 2015. Thesis, NSYSU. Accessed November 22, 2019. http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0717115-140159.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Su, Pei-jin. “Development of a Flexural Plate-wave Based Alpha-fetoprotein Biosensor with High Performances and Fabrication Yield.” 2015. Web. 22 Nov 2019.

Vancouver:

Su P. Development of a Flexural Plate-wave Based Alpha-fetoprotein Biosensor with High Performances and Fabrication Yield. [Internet] [Thesis]. NSYSU; 2015. [cited 2019 Nov 22]. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0717115-140159.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Su P. Development of a Flexural Plate-wave Based Alpha-fetoprotein Biosensor with High Performances and Fabrication Yield. [Thesis]. NSYSU; 2015. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0717115-140159

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


NSYSU

13. Hsiao, Wei-Chih. A dB-Linear Programmable Variable Gain Amplifier and A Voltage Peak Detector with Digital Calibration for FPW-based Allergy Antibody Sensing System.

Degree: Master, Electrical Engineering, 2012, NSYSU

 This thesis proposes a dB-linear programmable variable gain amplifier (VGA) and a voltage peak detector with digital calibration for FPW-based antibody sensing system. In the… (more)

Subjects/Keywords: flexural-plate-wave (FPW); peak detector; digital calibration; reconfiguration; local-feedback; variable gain amplifier; dB-linear

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Hsiao, W. (2012). A dB-Linear Programmable Variable Gain Amplifier and A Voltage Peak Detector with Digital Calibration for FPW-based Allergy Antibody Sensing System. (Thesis). NSYSU. Retrieved from http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0710112-123550

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Hsiao, Wei-Chih. “A dB-Linear Programmable Variable Gain Amplifier and A Voltage Peak Detector with Digital Calibration for FPW-based Allergy Antibody Sensing System.” 2012. Thesis, NSYSU. Accessed November 22, 2019. http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0710112-123550.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Hsiao, Wei-Chih. “A dB-Linear Programmable Variable Gain Amplifier and A Voltage Peak Detector with Digital Calibration for FPW-based Allergy Antibody Sensing System.” 2012. Web. 22 Nov 2019.

Vancouver:

Hsiao W. A dB-Linear Programmable Variable Gain Amplifier and A Voltage Peak Detector with Digital Calibration for FPW-based Allergy Antibody Sensing System. [Internet] [Thesis]. NSYSU; 2012. [cited 2019 Nov 22]. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0710112-123550.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Hsiao W. A dB-Linear Programmable Variable Gain Amplifier and A Voltage Peak Detector with Digital Calibration for FPW-based Allergy Antibody Sensing System. [Thesis]. NSYSU; 2012. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0710112-123550

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


NSYSU

14. Lan, Je-wei. Development of Flexural Plate-wave Based Micro Biosensors for Rapid Detection of Liver/Colorectal/Prostate Cancer.

Degree: PhD, Electrical Engineering, 2018, NSYSU

 According to the 2016 annual report of the Health Promotion Administration, Ministry of Health and Welfare, Taiwan, cancer is ranked first in the top ten… (more)

Subjects/Keywords: insertion loss; detection limit; sensing linearity; self-assembled monolayers; alpha-fetoprotein; carcinoembryonic antigen; prostatic specific antigen; flexural plate-wave

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Lan, J. (2018). Development of Flexural Plate-wave Based Micro Biosensors for Rapid Detection of Liver/Colorectal/Prostate Cancer. (Doctoral Dissertation). NSYSU. Retrieved from http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0111118-130110

Chicago Manual of Style (16th Edition):

Lan, Je-wei. “Development of Flexural Plate-wave Based Micro Biosensors for Rapid Detection of Liver/Colorectal/Prostate Cancer.” 2018. Doctoral Dissertation, NSYSU. Accessed November 22, 2019. http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0111118-130110.

MLA Handbook (7th Edition):

Lan, Je-wei. “Development of Flexural Plate-wave Based Micro Biosensors for Rapid Detection of Liver/Colorectal/Prostate Cancer.” 2018. Web. 22 Nov 2019.

Vancouver:

Lan J. Development of Flexural Plate-wave Based Micro Biosensors for Rapid Detection of Liver/Colorectal/Prostate Cancer. [Internet] [Doctoral dissertation]. NSYSU; 2018. [cited 2019 Nov 22]. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0111118-130110.

Council of Science Editors:

Lan J. Development of Flexural Plate-wave Based Micro Biosensors for Rapid Detection of Liver/Colorectal/Prostate Cancer. [Doctoral Dissertation]. NSYSU; 2018. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0111118-130110


NSYSU

15. Huang, Hao-Chun. A Highly Sensitive Portable Microsystem for Rapid Marijuana Detection and A Peak Detector with Offset Cancellation.

Degree: Master, Electrical Engineering, 2018, NSYSU

 As early as in the 1960s, drugs abuse has long been a serious problem in the world.The most popular one is marijuana, where 160 million… (more)

Subjects/Keywords: peak detector; portable medical device; flexural plate wave microsonic sensor; resonant frequency shift; dynamic offset voltage cancellation

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Huang, H. (2018). A Highly Sensitive Portable Microsystem for Rapid Marijuana Detection and A Peak Detector with Offset Cancellation. (Thesis). NSYSU. Retrieved from http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0629118-213302

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Huang, Hao-Chun. “A Highly Sensitive Portable Microsystem for Rapid Marijuana Detection and A Peak Detector with Offset Cancellation.” 2018. Thesis, NSYSU. Accessed November 22, 2019. http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0629118-213302.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Huang, Hao-Chun. “A Highly Sensitive Portable Microsystem for Rapid Marijuana Detection and A Peak Detector with Offset Cancellation.” 2018. Web. 22 Nov 2019.

Vancouver:

Huang H. A Highly Sensitive Portable Microsystem for Rapid Marijuana Detection and A Peak Detector with Offset Cancellation. [Internet] [Thesis]. NSYSU; 2018. [cited 2019 Nov 22]. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0629118-213302.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Huang H. A Highly Sensitive Portable Microsystem for Rapid Marijuana Detection and A Peak Detector with Offset Cancellation. [Thesis]. NSYSU; 2018. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0629118-213302

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

16. Aklouche, Omar. Réduction des niveaux vibratoires d'un panneau au moyen de trous noirs acoustiques structurés en réseau périodique : conception d'une méta-plaque : Reduction of the vibrational levels of a panel by means of acoustic black holes structured in a periodic lattice : design of a meta-plate.

Degree: Docteur es, Acoustique, 2017, Le Mans

Le "Trou Noir Acoustique" (TNA) constitue un moyen passif de réduction des vibrations des structures sans pour autant augmenter leur masse. Il s’agit d’un amincissement… (more)

Subjects/Keywords: Trou noir acoustique; Vibrations de flexion; Amortissement passif; Diffusion d'ondes; Réseau périodique; Méta-plaque; Bandes interdites; Acoustic black holes; Flexural vibrations; Passive damping; Wave scattering; Periodic lattice; Meta-plate; Band gaps; 620.37

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Aklouche, O. (2017). Réduction des niveaux vibratoires d'un panneau au moyen de trous noirs acoustiques structurés en réseau périodique : conception d'une méta-plaque : Reduction of the vibrational levels of a panel by means of acoustic black holes structured in a periodic lattice : design of a meta-plate. (Doctoral Dissertation). Le Mans. Retrieved from http://www.theses.fr/2017LEMA1030

Chicago Manual of Style (16th Edition):

Aklouche, Omar. “Réduction des niveaux vibratoires d'un panneau au moyen de trous noirs acoustiques structurés en réseau périodique : conception d'une méta-plaque : Reduction of the vibrational levels of a panel by means of acoustic black holes structured in a periodic lattice : design of a meta-plate.” 2017. Doctoral Dissertation, Le Mans. Accessed November 22, 2019. http://www.theses.fr/2017LEMA1030.

MLA Handbook (7th Edition):

Aklouche, Omar. “Réduction des niveaux vibratoires d'un panneau au moyen de trous noirs acoustiques structurés en réseau périodique : conception d'une méta-plaque : Reduction of the vibrational levels of a panel by means of acoustic black holes structured in a periodic lattice : design of a meta-plate.” 2017. Web. 22 Nov 2019.

Vancouver:

Aklouche O. Réduction des niveaux vibratoires d'un panneau au moyen de trous noirs acoustiques structurés en réseau périodique : conception d'une méta-plaque : Reduction of the vibrational levels of a panel by means of acoustic black holes structured in a periodic lattice : design of a meta-plate. [Internet] [Doctoral dissertation]. Le Mans; 2017. [cited 2019 Nov 22]. Available from: http://www.theses.fr/2017LEMA1030.

Council of Science Editors:

Aklouche O. Réduction des niveaux vibratoires d'un panneau au moyen de trous noirs acoustiques structurés en réseau périodique : conception d'une méta-plaque : Reduction of the vibrational levels of a panel by means of acoustic black holes structured in a periodic lattice : design of a meta-plate. [Doctoral Dissertation]. Le Mans; 2017. Available from: http://www.theses.fr/2017LEMA1030

.