Advanced search options

Advanced Search Options 🞨

Browse by author name (“Author name starts with…”).

Find ETDs with:

in
/  
in
/  
in
/  
in

Written in Published in Earliest date Latest date

Sorted by

Results per page:

Sorted by: relevance · author · university · dateNew search

You searched for subject:(cooling tower). Showing records 1 – 30 of 48 total matches.

[1] [2]

Search Limiters

Last 2 Years | English Only

Languages

Country

▼ Search Limiters


Texas A&M University

1. Xie, Xie. Modeling and Optimization of the Cooling Tower under Unsaturated Outlet Air Conditions.

Degree: MS, Mechanical Engineering, 2016, Texas A&M University

 This thesis presents a comprehensive methodology for engineers and plant managers to use for optimizing the combined chiller power and cooling tower fan power for… (more)

Subjects/Keywords: Cooling Tower; Optimization; Unsaturated Air Conditions

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Xie, X. (2016). Modeling and Optimization of the Cooling Tower under Unsaturated Outlet Air Conditions. (Masters Thesis). Texas A&M University. Retrieved from http://hdl.handle.net/1969.1/158118

Chicago Manual of Style (16th Edition):

Xie, Xie. “Modeling and Optimization of the Cooling Tower under Unsaturated Outlet Air Conditions.” 2016. Masters Thesis, Texas A&M University. Accessed September 20, 2019. http://hdl.handle.net/1969.1/158118.

MLA Handbook (7th Edition):

Xie, Xie. “Modeling and Optimization of the Cooling Tower under Unsaturated Outlet Air Conditions.” 2016. Web. 20 Sep 2019.

Vancouver:

Xie X. Modeling and Optimization of the Cooling Tower under Unsaturated Outlet Air Conditions. [Internet] [Masters thesis]. Texas A&M University; 2016. [cited 2019 Sep 20]. Available from: http://hdl.handle.net/1969.1/158118.

Council of Science Editors:

Xie X. Modeling and Optimization of the Cooling Tower under Unsaturated Outlet Air Conditions. [Masters Thesis]. Texas A&M University; 2016. Available from: http://hdl.handle.net/1969.1/158118

2. Mello, Lilian Cardoso de. Influência de variáveis de processo do desempenho de torre de resfriamento.

Degree: Mestrado, Engenharia Química, 2008, University of São Paulo

Com base em um modelo fenomenológico e a partir de dados experimentais obtidos numa planta piloto, foi obtida uma correlação entre o desempenho de uma… (more)

Subjects/Keywords: Cooling tower; Differential modelling of cooling tower performance; Engenharia química; Experimental characterization of a cooling tower; Mass transport; Simultaneous heat and mass transfer; Torres de resfriamento

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Mello, L. C. d. (2008). Influência de variáveis de processo do desempenho de torre de resfriamento. (Masters Thesis). University of São Paulo. Retrieved from http://www.teses.usp.br/teses/disponiveis/3/3137/tde-07112008-140442/ ;

Chicago Manual of Style (16th Edition):

Mello, Lilian Cardoso de. “Influência de variáveis de processo do desempenho de torre de resfriamento.” 2008. Masters Thesis, University of São Paulo. Accessed September 20, 2019. http://www.teses.usp.br/teses/disponiveis/3/3137/tde-07112008-140442/ ;.

MLA Handbook (7th Edition):

Mello, Lilian Cardoso de. “Influência de variáveis de processo do desempenho de torre de resfriamento.” 2008. Web. 20 Sep 2019.

Vancouver:

Mello LCd. Influência de variáveis de processo do desempenho de torre de resfriamento. [Internet] [Masters thesis]. University of São Paulo; 2008. [cited 2019 Sep 20]. Available from: http://www.teses.usp.br/teses/disponiveis/3/3137/tde-07112008-140442/ ;.

Council of Science Editors:

Mello LCd. Influência de variáveis de processo do desempenho de torre de resfriamento. [Masters Thesis]. University of São Paulo; 2008. Available from: http://www.teses.usp.br/teses/disponiveis/3/3137/tde-07112008-140442/ ;


University of Illinois – Urbana-Champaign

3. Kang, Daeho. Advances in the application of passive down-draft evaporative cooling technology in the cooling of buildings.

Degree: PhD, 0249, 2011, University of Illinois – Urbana-Champaign

 A passive down-draft evaporative cooling (PDEC) tower is a component that is designed to capture the wind at the top of a tower and cool… (more)

Subjects/Keywords: Passive Down-Draft Evaporative Cooling (PDEC); Passive Down-Draft Evaporative Cooling (PDEC) Tower; Building Simulation; Wind Tower

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Kang, D. (2011). Advances in the application of passive down-draft evaporative cooling technology in the cooling of buildings. (Doctoral Dissertation). University of Illinois – Urbana-Champaign. Retrieved from http://hdl.handle.net/2142/26273

Chicago Manual of Style (16th Edition):

Kang, Daeho. “Advances in the application of passive down-draft evaporative cooling technology in the cooling of buildings.” 2011. Doctoral Dissertation, University of Illinois – Urbana-Champaign. Accessed September 20, 2019. http://hdl.handle.net/2142/26273.

MLA Handbook (7th Edition):

Kang, Daeho. “Advances in the application of passive down-draft evaporative cooling technology in the cooling of buildings.” 2011. Web. 20 Sep 2019.

Vancouver:

Kang D. Advances in the application of passive down-draft evaporative cooling technology in the cooling of buildings. [Internet] [Doctoral dissertation]. University of Illinois – Urbana-Champaign; 2011. [cited 2019 Sep 20]. Available from: http://hdl.handle.net/2142/26273.

Council of Science Editors:

Kang D. Advances in the application of passive down-draft evaporative cooling technology in the cooling of buildings. [Doctoral Dissertation]. University of Illinois – Urbana-Champaign; 2011. Available from: http://hdl.handle.net/2142/26273


University of Tennessee – Knoxville

4. Costello, Elizabeth Stassun. Utilization of Rainwater as a Supplementary Water Source for Cooling Tower Makeup: A Sustainability Strategy for Potable Water Use Reduction.

Degree: MS, Environmental Engineering, 2012, University of Tennessee – Knoxville

  The use of rainwater as a supplementary water source for cooling water makeup was explored in an effort to reduce the potable water demand… (more)

Subjects/Keywords: rainwater; rainwater harvesting; cooling tower; potable water reduction; water sustainability; cooling water quality; Environmental Engineering

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Costello, E. S. (2012). Utilization of Rainwater as a Supplementary Water Source for Cooling Tower Makeup: A Sustainability Strategy for Potable Water Use Reduction. (Thesis). University of Tennessee – Knoxville. Retrieved from https://trace.tennessee.edu/utk_gradthes/1369

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Costello, Elizabeth Stassun. “Utilization of Rainwater as a Supplementary Water Source for Cooling Tower Makeup: A Sustainability Strategy for Potable Water Use Reduction.” 2012. Thesis, University of Tennessee – Knoxville. Accessed September 20, 2019. https://trace.tennessee.edu/utk_gradthes/1369.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Costello, Elizabeth Stassun. “Utilization of Rainwater as a Supplementary Water Source for Cooling Tower Makeup: A Sustainability Strategy for Potable Water Use Reduction.” 2012. Web. 20 Sep 2019.

Vancouver:

Costello ES. Utilization of Rainwater as a Supplementary Water Source for Cooling Tower Makeup: A Sustainability Strategy for Potable Water Use Reduction. [Internet] [Thesis]. University of Tennessee – Knoxville; 2012. [cited 2019 Sep 20]. Available from: https://trace.tennessee.edu/utk_gradthes/1369.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Costello ES. Utilization of Rainwater as a Supplementary Water Source for Cooling Tower Makeup: A Sustainability Strategy for Potable Water Use Reduction. [Thesis]. University of Tennessee – Knoxville; 2012. Available from: https://trace.tennessee.edu/utk_gradthes/1369

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

5. Hasan, Ala Ali. Performance Analysis of Heat Transfer Processes from Wet and Dry Surfaces: Cooling Towers and Heat Exchangers.

Degree: 2005, Helsinki University of Technology

 The objective of this work is to study the thermal and hydraulic performance of evaporatively cooled heat exchangers, including closed wet cooling towers, and dry… (more)

Subjects/Keywords: cooling tower; heat exchanger; heat transfer; mass transfer; fin; oval

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Hasan, A. A. (2005). Performance Analysis of Heat Transfer Processes from Wet and Dry Surfaces: Cooling Towers and Heat Exchangers. (Thesis). Helsinki University of Technology. Retrieved from http://lib.tkk.fi/Diss/2005/isbn9512276348/

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Hasan, Ala Ali. “Performance Analysis of Heat Transfer Processes from Wet and Dry Surfaces: Cooling Towers and Heat Exchangers.” 2005. Thesis, Helsinki University of Technology. Accessed September 20, 2019. http://lib.tkk.fi/Diss/2005/isbn9512276348/.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Hasan, Ala Ali. “Performance Analysis of Heat Transfer Processes from Wet and Dry Surfaces: Cooling Towers and Heat Exchangers.” 2005. Web. 20 Sep 2019.

Vancouver:

Hasan AA. Performance Analysis of Heat Transfer Processes from Wet and Dry Surfaces: Cooling Towers and Heat Exchangers. [Internet] [Thesis]. Helsinki University of Technology; 2005. [cited 2019 Sep 20]. Available from: http://lib.tkk.fi/Diss/2005/isbn9512276348/.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Hasan AA. Performance Analysis of Heat Transfer Processes from Wet and Dry Surfaces: Cooling Towers and Heat Exchangers. [Thesis]. Helsinki University of Technology; 2005. Available from: http://lib.tkk.fi/Diss/2005/isbn9512276348/

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

6. Maia, Joana Sofia Costa Barros. Otimização Energética do Sistema de Refrigeração da máquina de impregnar ZELL.

Degree: 2014, Instituto Politécnico do Porto

Esta dissertação teve como objetivo fundamental a otimização energética do sistema de refrigeração da máquina de impregnar tela ZELL e, como objetivo adicional, a avaliação… (more)

Subjects/Keywords: Otimização energética; Torre de arrefecimento; Corrosão; Energy Optimization; Cooling Tower; Corrosion

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Maia, J. S. C. B. (2014). Otimização Energética do Sistema de Refrigeração da máquina de impregnar ZELL. (Thesis). Instituto Politécnico do Porto. Retrieved from http://www.rcaap.pt/detail.jsp?id=oai:recipp.ipp.pt:10400.22/5791

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Maia, Joana Sofia Costa Barros. “Otimização Energética do Sistema de Refrigeração da máquina de impregnar ZELL.” 2014. Thesis, Instituto Politécnico do Porto. Accessed September 20, 2019. http://www.rcaap.pt/detail.jsp?id=oai:recipp.ipp.pt:10400.22/5791.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Maia, Joana Sofia Costa Barros. “Otimização Energética do Sistema de Refrigeração da máquina de impregnar ZELL.” 2014. Web. 20 Sep 2019.

Vancouver:

Maia JSCB. Otimização Energética do Sistema de Refrigeração da máquina de impregnar ZELL. [Internet] [Thesis]. Instituto Politécnico do Porto; 2014. [cited 2019 Sep 20]. Available from: http://www.rcaap.pt/detail.jsp?id=oai:recipp.ipp.pt:10400.22/5791.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Maia JSCB. Otimização Energética do Sistema de Refrigeração da máquina de impregnar ZELL. [Thesis]. Instituto Politécnico do Porto; 2014. Available from: http://www.rcaap.pt/detail.jsp?id=oai:recipp.ipp.pt:10400.22/5791

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

7. Ruiz Ramírez, Javier. Caracterización experimental y modelización del binomio sistema de distribución-separador de gotas en torres de refrigeración .

Degree: Ingeniería Térmica y de Fluidos, 2014, Universidad Politécnica de Cartagena

 [SPA] Las emisiones de gotas ocasionadas por el principio de funcionamiento de torres de refrigeración son indeseables por diferentes motivos, pero principalmente porque suponer un… (more)

Subjects/Keywords: Refrigeración; Aparatos frigoríficos; Eficiencia energética; Legionella; Cooling tower; Energy consumption

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Ruiz Ramírez, J. (2014). Caracterización experimental y modelización del binomio sistema de distribución-separador de gotas en torres de refrigeración . (Thesis). Universidad Politécnica de Cartagena. Retrieved from http://hdl.handle.net/10317/4079

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Ruiz Ramírez, Javier. “Caracterización experimental y modelización del binomio sistema de distribución-separador de gotas en torres de refrigeración .” 2014. Thesis, Universidad Politécnica de Cartagena. Accessed September 20, 2019. http://hdl.handle.net/10317/4079.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Ruiz Ramírez, Javier. “Caracterización experimental y modelización del binomio sistema de distribución-separador de gotas en torres de refrigeración .” 2014. Web. 20 Sep 2019.

Vancouver:

Ruiz Ramírez J. Caracterización experimental y modelización del binomio sistema de distribución-separador de gotas en torres de refrigeración . [Internet] [Thesis]. Universidad Politécnica de Cartagena; 2014. [cited 2019 Sep 20]. Available from: http://hdl.handle.net/10317/4079.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Ruiz Ramírez J. Caracterización experimental y modelización del binomio sistema de distribución-separador de gotas en torres de refrigeración . [Thesis]. Universidad Politécnica de Cartagena; 2014. Available from: http://hdl.handle.net/10317/4079

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

8. Leandro, Ana Catarina Cardoso. Projeto de um sistema de produção de energia a partir de vapor e a avaliação do melhor processo para condensação.

Degree: 2016, Instituto Politécnico do Porto

A acumulação de resíduos no meio ambiente é cada vez mais alvo de preocupação, dada a poluição que acarreta. Sendo a transformação destes resíduos uma… (more)

Subjects/Keywords: Energia; Turbina; Torre de arrefecimento; Aerocondensador; Energy; Turbine; Cooling tower; Aerocondenser

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Leandro, A. C. C. (2016). Projeto de um sistema de produção de energia a partir de vapor e a avaliação do melhor processo para condensação. (Thesis). Instituto Politécnico do Porto. Retrieved from https://www.rcaap.pt/detail.jsp?id=oai:recipp.ipp.pt:10400.22/10654

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Leandro, Ana Catarina Cardoso. “Projeto de um sistema de produção de energia a partir de vapor e a avaliação do melhor processo para condensação.” 2016. Thesis, Instituto Politécnico do Porto. Accessed September 20, 2019. https://www.rcaap.pt/detail.jsp?id=oai:recipp.ipp.pt:10400.22/10654.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Leandro, Ana Catarina Cardoso. “Projeto de um sistema de produção de energia a partir de vapor e a avaliação do melhor processo para condensação.” 2016. Web. 20 Sep 2019.

Vancouver:

Leandro ACC. Projeto de um sistema de produção de energia a partir de vapor e a avaliação do melhor processo para condensação. [Internet] [Thesis]. Instituto Politécnico do Porto; 2016. [cited 2019 Sep 20]. Available from: https://www.rcaap.pt/detail.jsp?id=oai:recipp.ipp.pt:10400.22/10654.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Leandro ACC. Projeto de um sistema de produção de energia a partir de vapor e a avaliação do melhor processo para condensação. [Thesis]. Instituto Politécnico do Porto; 2016. Available from: https://www.rcaap.pt/detail.jsp?id=oai:recipp.ipp.pt:10400.22/10654

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Delft University of Technology

9. Olariu, R. Treatment of cooling tower blowdown water: The effect of biodispersant on the ultrafiltration membrane:.

Degree: 2015, Delft University of Technology

 Taking into account the growing population, water scarcity is a relevant problem which needs to be addressed. Wastewater needs to be assured by quality, ecosystems… (more)

Subjects/Keywords: water; water treatment; cooling tower; blowdown; biodispersant; ultrafiltration; coagulation

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Olariu, R. (2015). Treatment of cooling tower blowdown water: The effect of biodispersant on the ultrafiltration membrane:. (Masters Thesis). Delft University of Technology. Retrieved from http://resolver.tudelft.nl/uuid:4ce2bed4-c879-44fb-8e13-61aa22e0b3f6

Chicago Manual of Style (16th Edition):

Olariu, R. “Treatment of cooling tower blowdown water: The effect of biodispersant on the ultrafiltration membrane:.” 2015. Masters Thesis, Delft University of Technology. Accessed September 20, 2019. http://resolver.tudelft.nl/uuid:4ce2bed4-c879-44fb-8e13-61aa22e0b3f6.

MLA Handbook (7th Edition):

Olariu, R. “Treatment of cooling tower blowdown water: The effect of biodispersant on the ultrafiltration membrane:.” 2015. Web. 20 Sep 2019.

Vancouver:

Olariu R. Treatment of cooling tower blowdown water: The effect of biodispersant on the ultrafiltration membrane:. [Internet] [Masters thesis]. Delft University of Technology; 2015. [cited 2019 Sep 20]. Available from: http://resolver.tudelft.nl/uuid:4ce2bed4-c879-44fb-8e13-61aa22e0b3f6.

Council of Science Editors:

Olariu R. Treatment of cooling tower blowdown water: The effect of biodispersant on the ultrafiltration membrane:. [Masters Thesis]. Delft University of Technology; 2015. Available from: http://resolver.tudelft.nl/uuid:4ce2bed4-c879-44fb-8e13-61aa22e0b3f6


Mississippi State University

10. Zdaniuk, Gregory J. DESIGN, ASSEMBLY, AND ASSESSMENT OF AN EXPERIMENTAL APPARATUS TO MEASURE FOULING OF CONDENSER TUBES.

Degree: MS, Mechanical Engineering, 2003, Mississippi State University

 This thesis discusses the design, construction, and debugging of an experimental apparatus to measure fouling in smooth and/or augmented copper alloy condenser tubes. In addition,… (more)

Subjects/Keywords: Fouling; cooling tower; condenser tubes

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Zdaniuk, G. J. (2003). DESIGN, ASSEMBLY, AND ASSESSMENT OF AN EXPERIMENTAL APPARATUS TO MEASURE FOULING OF CONDENSER TUBES. (Masters Thesis). Mississippi State University. Retrieved from http://sun.library.msstate.edu/ETD-db/theses/available/etd-11102003-133248/ ;

Chicago Manual of Style (16th Edition):

Zdaniuk, Gregory J. “DESIGN, ASSEMBLY, AND ASSESSMENT OF AN EXPERIMENTAL APPARATUS TO MEASURE FOULING OF CONDENSER TUBES.” 2003. Masters Thesis, Mississippi State University. Accessed September 20, 2019. http://sun.library.msstate.edu/ETD-db/theses/available/etd-11102003-133248/ ;.

MLA Handbook (7th Edition):

Zdaniuk, Gregory J. “DESIGN, ASSEMBLY, AND ASSESSMENT OF AN EXPERIMENTAL APPARATUS TO MEASURE FOULING OF CONDENSER TUBES.” 2003. Web. 20 Sep 2019.

Vancouver:

Zdaniuk GJ. DESIGN, ASSEMBLY, AND ASSESSMENT OF AN EXPERIMENTAL APPARATUS TO MEASURE FOULING OF CONDENSER TUBES. [Internet] [Masters thesis]. Mississippi State University; 2003. [cited 2019 Sep 20]. Available from: http://sun.library.msstate.edu/ETD-db/theses/available/etd-11102003-133248/ ;.

Council of Science Editors:

Zdaniuk GJ. DESIGN, ASSEMBLY, AND ASSESSMENT OF AN EXPERIMENTAL APPARATUS TO MEASURE FOULING OF CONDENSER TUBES. [Masters Thesis]. Mississippi State University; 2003. Available from: http://sun.library.msstate.edu/ETD-db/theses/available/etd-11102003-133248/ ;


Oklahoma State University

11. Ramesh, Annamalai. Experimental Facility to Measure Fouling Resistance in Condensers.

Degree: Mechanical & Aerospace Engineering, 2010, Oklahoma State University

 Heat exchangers are employed to transfer thermal energy between two fluids. Fouling is defined as the accumulation of deposits on the heat transfer surface which… (more)

Subjects/Keywords: chevron angle; condenser; cooling tower; fouling; heat exchanger

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Ramesh, A. (2010). Experimental Facility to Measure Fouling Resistance in Condensers. (Thesis). Oklahoma State University. Retrieved from http://hdl.handle.net/11244/10041

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Ramesh, Annamalai. “Experimental Facility to Measure Fouling Resistance in Condensers.” 2010. Thesis, Oklahoma State University. Accessed September 20, 2019. http://hdl.handle.net/11244/10041.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Ramesh, Annamalai. “Experimental Facility to Measure Fouling Resistance in Condensers.” 2010. Web. 20 Sep 2019.

Vancouver:

Ramesh A. Experimental Facility to Measure Fouling Resistance in Condensers. [Internet] [Thesis]. Oklahoma State University; 2010. [cited 2019 Sep 20]. Available from: http://hdl.handle.net/11244/10041.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Ramesh A. Experimental Facility to Measure Fouling Resistance in Condensers. [Thesis]. Oklahoma State University; 2010. Available from: http://hdl.handle.net/11244/10041

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

12. Eriksson, Rebecca. Legionella i kyltorn : Enkätundersökning gällande kommuners och länsstyrelsers tillsyn på kyltorn och behovet av ökad prioritering.

Degree: Ecology and Environmental Sciences, 2018, Umeå University

  If cooling towers are poorly maintained there is a risk of microbial growth such as Legionella which in turn might spread via aerosols and… (more)

Subjects/Keywords: cooling tower; legionella; legionnaires’ disease; supervision; legislation; Natural Sciences; Naturvetenskap

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Eriksson, R. (2018). Legionella i kyltorn : Enkätundersökning gällande kommuners och länsstyrelsers tillsyn på kyltorn och behovet av ökad prioritering. (Thesis). Umeå University. Retrieved from http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-153228

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Eriksson, Rebecca. “Legionella i kyltorn : Enkätundersökning gällande kommuners och länsstyrelsers tillsyn på kyltorn och behovet av ökad prioritering.” 2018. Thesis, Umeå University. Accessed September 20, 2019. http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-153228.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Eriksson, Rebecca. “Legionella i kyltorn : Enkätundersökning gällande kommuners och länsstyrelsers tillsyn på kyltorn och behovet av ökad prioritering.” 2018. Web. 20 Sep 2019.

Vancouver:

Eriksson R. Legionella i kyltorn : Enkätundersökning gällande kommuners och länsstyrelsers tillsyn på kyltorn och behovet av ökad prioritering. [Internet] [Thesis]. Umeå University; 2018. [cited 2019 Sep 20]. Available from: http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-153228.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Eriksson R. Legionella i kyltorn : Enkätundersökning gällande kommuners och länsstyrelsers tillsyn på kyltorn och behovet av ökad prioritering. [Thesis]. Umeå University; 2018. Available from: http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-153228

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Stellenbosch University

13. Ehlers, Frederik Coenrad. Condition-based monitoring of natural draught wet-cooling tower performance-related parameters.

Degree: MScEng, Mechanical and Mechatronic Engineering, 2011, Stellenbosch University

 ENGLISH ABSTRACT: The meteorological conditions at Eskom’s Majuba Power Station are measured, evaluated and trended in this dissertation. The results are used to evaluate the… (more)

Subjects/Keywords: Wet-cooling towers; Cooling towers  – Design; Lapse rate; Inversion; Dissertations  – Mechanical engineering; Natural draught wet-cooling tower

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Ehlers, F. C. (2011). Condition-based monitoring of natural draught wet-cooling tower performance-related parameters. (Masters Thesis). Stellenbosch University. Retrieved from http://hdl.handle.net/10019.1/17904

Chicago Manual of Style (16th Edition):

Ehlers, Frederik Coenrad. “Condition-based monitoring of natural draught wet-cooling tower performance-related parameters.” 2011. Masters Thesis, Stellenbosch University. Accessed September 20, 2019. http://hdl.handle.net/10019.1/17904.

MLA Handbook (7th Edition):

Ehlers, Frederik Coenrad. “Condition-based monitoring of natural draught wet-cooling tower performance-related parameters.” 2011. Web. 20 Sep 2019.

Vancouver:

Ehlers FC. Condition-based monitoring of natural draught wet-cooling tower performance-related parameters. [Internet] [Masters thesis]. Stellenbosch University; 2011. [cited 2019 Sep 20]. Available from: http://hdl.handle.net/10019.1/17904.

Council of Science Editors:

Ehlers FC. Condition-based monitoring of natural draught wet-cooling tower performance-related parameters. [Masters Thesis]. Stellenbosch University; 2011. Available from: http://hdl.handle.net/10019.1/17904


Brno University of Technology

14. Velešík, Aleš. Stanovení výkonnosti chladicího okruhu - chladící věž .

Degree: 2015, Brno University of Technology

 Cílem této práce je stanovení výkonnosti chladícího okruhu a jeho popis. K tomu je zapotřebí sestavení struktury empirického modelu chladící věže, jež jsem sestavil za… (more)

Subjects/Keywords: Chladící věž; lineární regrese; Rankine-Clausiův cyklus; regresní triplet; části chladící věže; matematické modelování; Cooling tower; linear regression; Clausius-Rankine cycle; regression triplet; parts of cooling tower; mathematical modeling

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Velešík, A. (2015). Stanovení výkonnosti chladicího okruhu - chladící věž . (Thesis). Brno University of Technology. Retrieved from http://hdl.handle.net/11012/41673

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Velešík, Aleš. “Stanovení výkonnosti chladicího okruhu - chladící věž .” 2015. Thesis, Brno University of Technology. Accessed September 20, 2019. http://hdl.handle.net/11012/41673.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Velešík, Aleš. “Stanovení výkonnosti chladicího okruhu - chladící věž .” 2015. Web. 20 Sep 2019.

Vancouver:

Velešík A. Stanovení výkonnosti chladicího okruhu - chladící věž . [Internet] [Thesis]. Brno University of Technology; 2015. [cited 2019 Sep 20]. Available from: http://hdl.handle.net/11012/41673.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Velešík A. Stanovení výkonnosti chladicího okruhu - chladící věž . [Thesis]. Brno University of Technology; 2015. Available from: http://hdl.handle.net/11012/41673

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Université de Grenoble

15. Putois, Tamara. Etude du traitement de désinfection des eaux de refroidissement par le couplage H2O2/UV : application à une tour aéroréfrigérante : Disinfection process study of cooling water by H2O2/UV : application to a cooling tower.

Degree: Docteur es, Chimie, 2012, Université de Grenoble

Les légionelles sont un enjeu de santé publique majeur car ces bactéries sont responsables des cas de légionellose, parfois mortels. Les tours aéroréfrigérantes (TAR) peuvent… (more)

Subjects/Keywords: Eaux de refroidissement; Peroxyde d'hydrogène; Ultraviolets; Désinfection; Biofilms; Tour aéroréfrigérante; Cooling water; Hydrogen peroxide; Ultraviolet; Desinfection; Biofilms; Cooling tower

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Putois, T. (2012). Etude du traitement de désinfection des eaux de refroidissement par le couplage H2O2/UV : application à une tour aéroréfrigérante : Disinfection process study of cooling water by H2O2/UV : application to a cooling tower. (Doctoral Dissertation). Université de Grenoble. Retrieved from http://www.theses.fr/2012GRENA025

Chicago Manual of Style (16th Edition):

Putois, Tamara. “Etude du traitement de désinfection des eaux de refroidissement par le couplage H2O2/UV : application à une tour aéroréfrigérante : Disinfection process study of cooling water by H2O2/UV : application to a cooling tower.” 2012. Doctoral Dissertation, Université de Grenoble. Accessed September 20, 2019. http://www.theses.fr/2012GRENA025.

MLA Handbook (7th Edition):

Putois, Tamara. “Etude du traitement de désinfection des eaux de refroidissement par le couplage H2O2/UV : application à une tour aéroréfrigérante : Disinfection process study of cooling water by H2O2/UV : application to a cooling tower.” 2012. Web. 20 Sep 2019.

Vancouver:

Putois T. Etude du traitement de désinfection des eaux de refroidissement par le couplage H2O2/UV : application à une tour aéroréfrigérante : Disinfection process study of cooling water by H2O2/UV : application to a cooling tower. [Internet] [Doctoral dissertation]. Université de Grenoble; 2012. [cited 2019 Sep 20]. Available from: http://www.theses.fr/2012GRENA025.

Council of Science Editors:

Putois T. Etude du traitement de désinfection des eaux de refroidissement par le couplage H2O2/UV : application à une tour aéroréfrigérante : Disinfection process study of cooling water by H2O2/UV : application to a cooling tower. [Doctoral Dissertation]. Université de Grenoble; 2012. Available from: http://www.theses.fr/2012GRENA025

16. Yedatore Venkatesh, Pranav. Creating a New Model to Predict Cooling Tower Performance and Determining Energy Saving Opportunities through Economizer Operation.

Degree: 2015, University of Massachusetts

Cooling towers form an important part of chilled water systems and perform the function of rejecting the heat to the atmosphere. These systems are… (more)

Subjects/Keywords: Cooling Tower Performance; Prediction Model; Energy Efficiency; Free Cooling; Waterside Economizer; Chilled Water System Assessment Tool; Engineering

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Yedatore Venkatesh, P. (2015). Creating a New Model to Predict Cooling Tower Performance and Determining Energy Saving Opportunities through Economizer Operation. (Thesis). University of Massachusetts. Retrieved from https://scholarworks.umass.edu/masters_theses_2/489

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Yedatore Venkatesh, Pranav. “Creating a New Model to Predict Cooling Tower Performance and Determining Energy Saving Opportunities through Economizer Operation.” 2015. Thesis, University of Massachusetts. Accessed September 20, 2019. https://scholarworks.umass.edu/masters_theses_2/489.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Yedatore Venkatesh, Pranav. “Creating a New Model to Predict Cooling Tower Performance and Determining Energy Saving Opportunities through Economizer Operation.” 2015. Web. 20 Sep 2019.

Vancouver:

Yedatore Venkatesh P. Creating a New Model to Predict Cooling Tower Performance and Determining Energy Saving Opportunities through Economizer Operation. [Internet] [Thesis]. University of Massachusetts; 2015. [cited 2019 Sep 20]. Available from: https://scholarworks.umass.edu/masters_theses_2/489.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Yedatore Venkatesh P. Creating a New Model to Predict Cooling Tower Performance and Determining Energy Saving Opportunities through Economizer Operation. [Thesis]. University of Massachusetts; 2015. Available from: https://scholarworks.umass.edu/masters_theses_2/489

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


NSYSU

17. Cheng, Hao-An. The Noise Barrier of Cooling Tower-The Application of Aluminum Porous Board.

Degree: Master, Mechanical Engineering, 2001, NSYSU

 This thesis uses aluminum porous board (AP board) to study the noise reduction for cooling tower. It sets the barrier to isolate the sound propagation.… (more)

Subjects/Keywords: aluminum porous board; cooling tower; barrier

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Cheng, H. (2001). The Noise Barrier of Cooling Tower-The Application of Aluminum Porous Board. (Thesis). NSYSU. Retrieved from http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0716101-142041

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Cheng, Hao-An. “The Noise Barrier of Cooling Tower-The Application of Aluminum Porous Board.” 2001. Thesis, NSYSU. Accessed September 20, 2019. http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0716101-142041.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Cheng, Hao-An. “The Noise Barrier of Cooling Tower-The Application of Aluminum Porous Board.” 2001. Web. 20 Sep 2019.

Vancouver:

Cheng H. The Noise Barrier of Cooling Tower-The Application of Aluminum Porous Board. [Internet] [Thesis]. NSYSU; 2001. [cited 2019 Sep 20]. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0716101-142041.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Cheng H. The Noise Barrier of Cooling Tower-The Application of Aluminum Porous Board. [Thesis]. NSYSU; 2001. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0716101-142041

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Arizona State University

18. Al-Hassawi, Omar Dhia Sadulah. Advancing Performance of Passive Downdraft Cooling Towers.

Degree: Architecture, 2017, Arizona State University

Subjects/Keywords: Sustainability; Architectural engineering; Architecture; Multi-stage Downdraft Cooling Tower; Passive and Hybrid Downdraft Cooling Towers; Passive Cooling; Passive Downdraft Evaporative Cooling Tower; Passive Downdraught Cooling; Single Stage Downdraft Cooling Tower

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Al-Hassawi, O. D. S. (2017). Advancing Performance of Passive Downdraft Cooling Towers. (Doctoral Dissertation). Arizona State University. Retrieved from http://repository.asu.edu/items/46229

Chicago Manual of Style (16th Edition):

Al-Hassawi, Omar Dhia Sadulah. “Advancing Performance of Passive Downdraft Cooling Towers.” 2017. Doctoral Dissertation, Arizona State University. Accessed September 20, 2019. http://repository.asu.edu/items/46229.

MLA Handbook (7th Edition):

Al-Hassawi, Omar Dhia Sadulah. “Advancing Performance of Passive Downdraft Cooling Towers.” 2017. Web. 20 Sep 2019.

Vancouver:

Al-Hassawi ODS. Advancing Performance of Passive Downdraft Cooling Towers. [Internet] [Doctoral dissertation]. Arizona State University; 2017. [cited 2019 Sep 20]. Available from: http://repository.asu.edu/items/46229.

Council of Science Editors:

Al-Hassawi ODS. Advancing Performance of Passive Downdraft Cooling Towers. [Doctoral Dissertation]. Arizona State University; 2017. Available from: http://repository.asu.edu/items/46229

19. Fernandes, Mariana. Proposta e comparação de um modelo fenomenológico com base em alto transporte de massa e supersaturação para torre de resfriamento de água.

Degree: Mestrado, Engenharia Química, 2011, University of São Paulo

Torres de resfriamento são equipamentos muito utilizados na indústria e que muitas vezes operam sob condições adversas, particularmente, temperatura de água acima dos 50°C na… (more)

Subjects/Keywords: Cooling tower; Heat transfer; Mass transport; Supersaturação; Supersaturation; Torres de resfriamento; Transporte de calor; Transporte de massa

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Fernandes, M. (2011). Proposta e comparação de um modelo fenomenológico com base em alto transporte de massa e supersaturação para torre de resfriamento de água. (Masters Thesis). University of São Paulo. Retrieved from http://www.teses.usp.br/teses/disponiveis/3/3137/tde-27032012-114749/ ;

Chicago Manual of Style (16th Edition):

Fernandes, Mariana. “Proposta e comparação de um modelo fenomenológico com base em alto transporte de massa e supersaturação para torre de resfriamento de água.” 2011. Masters Thesis, University of São Paulo. Accessed September 20, 2019. http://www.teses.usp.br/teses/disponiveis/3/3137/tde-27032012-114749/ ;.

MLA Handbook (7th Edition):

Fernandes, Mariana. “Proposta e comparação de um modelo fenomenológico com base em alto transporte de massa e supersaturação para torre de resfriamento de água.” 2011. Web. 20 Sep 2019.

Vancouver:

Fernandes M. Proposta e comparação de um modelo fenomenológico com base em alto transporte de massa e supersaturação para torre de resfriamento de água. [Internet] [Masters thesis]. University of São Paulo; 2011. [cited 2019 Sep 20]. Available from: http://www.teses.usp.br/teses/disponiveis/3/3137/tde-27032012-114749/ ;.

Council of Science Editors:

Fernandes M. Proposta e comparação de um modelo fenomenológico com base em alto transporte de massa e supersaturação para torre de resfriamento de água. [Masters Thesis]. University of São Paulo; 2011. Available from: http://www.teses.usp.br/teses/disponiveis/3/3137/tde-27032012-114749/ ;

20. Graves, Rhett David. Thermodynamic Modeling and Optimization of a Screw Compressor Chiller and Cooling Tower System.

Degree: 2004, Texas A&M University

 This thesis presents a thermodynamic model for a screw chiller and cooling tower system for the purpose of developing an optimized control algorithm for the… (more)

Subjects/Keywords: Screw; Chiller; Compressor; Cooling Tower; Modeling; Optimization

…viii LIST OF TABLES TABLE Page Table 5.1. Cooling Tower Node Values… …and the cooling tower, including the power consumption by the chilled-water and condenser… …with moving the condenser water between the cooling tower and chiller. The second advantage… …is an increase in cooling tower effectiveness. As the condenser-water flow rate is… …streams, which means there is more driving potential for heat transfer in the cooling tower… 

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Graves, R. D. (2004). Thermodynamic Modeling and Optimization of a Screw Compressor Chiller and Cooling Tower System. (Thesis). Texas A&M University. Retrieved from http://hdl.handle.net/1969.1/427

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Graves, Rhett David. “Thermodynamic Modeling and Optimization of a Screw Compressor Chiller and Cooling Tower System.” 2004. Thesis, Texas A&M University. Accessed September 20, 2019. http://hdl.handle.net/1969.1/427.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Graves, Rhett David. “Thermodynamic Modeling and Optimization of a Screw Compressor Chiller and Cooling Tower System.” 2004. Web. 20 Sep 2019.

Vancouver:

Graves RD. Thermodynamic Modeling and Optimization of a Screw Compressor Chiller and Cooling Tower System. [Internet] [Thesis]. Texas A&M University; 2004. [cited 2019 Sep 20]. Available from: http://hdl.handle.net/1969.1/427.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Graves RD. Thermodynamic Modeling and Optimization of a Screw Compressor Chiller and Cooling Tower System. [Thesis]. Texas A&M University; 2004. Available from: http://hdl.handle.net/1969.1/427

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Alabama

21. Zhao, Zilai. Energy performance estimation of cooling towers.

Degree: 2016, University of Alabama

 The goal of this project is to investigate and compare the performance of cooling towers using Effectiveness-NTU model and the empirical model of cooling towers.… (more)

Subjects/Keywords: Electronic Thesis or Dissertation;  – thesis; Mechanical engineering; Energy; Statistics; Cooling Tower; Estimation; Experiment; Heat Transfer; Psychometric; Validation

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Zhao, Z. (2016). Energy performance estimation of cooling towers. (Thesis). University of Alabama. Retrieved from http://purl.lib.ua.edu/163869

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Zhao, Zilai. “Energy performance estimation of cooling towers.” 2016. Thesis, University of Alabama. Accessed September 20, 2019. http://purl.lib.ua.edu/163869.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Zhao, Zilai. “Energy performance estimation of cooling towers.” 2016. Web. 20 Sep 2019.

Vancouver:

Zhao Z. Energy performance estimation of cooling towers. [Internet] [Thesis]. University of Alabama; 2016. [cited 2019 Sep 20]. Available from: http://purl.lib.ua.edu/163869.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Zhao Z. Energy performance estimation of cooling towers. [Thesis]. University of Alabama; 2016. Available from: http://purl.lib.ua.edu/163869

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

22. Vinha, João Celso Rosa da. Sistema de Torre de Refrigeração.

Degree: 2010, Instituto Politécnico do Porto

Mestrado em Engenharia Química - Ramo Optimização Energética na Indústria Química

Uma vez chegado o momento de elaborar uma tese para a conclusão do segundo… (more)

Subjects/Keywords: Impulsor; Força impulsionadora; Integração; Optimização; Reutilização; Torre de arrefecimento; Impeller; Driving force; Integration; Optimization; Reutilization; Cooling Tower

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Vinha, J. C. R. d. (2010). Sistema de Torre de Refrigeração. (Thesis). Instituto Politécnico do Porto. Retrieved from http://www.rcaap.pt/detail.jsp?id=oai:recipp.ipp.pt:10400.22/4409

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Vinha, João Celso Rosa da. “Sistema de Torre de Refrigeração.” 2010. Thesis, Instituto Politécnico do Porto. Accessed September 20, 2019. http://www.rcaap.pt/detail.jsp?id=oai:recipp.ipp.pt:10400.22/4409.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Vinha, João Celso Rosa da. “Sistema de Torre de Refrigeração.” 2010. Web. 20 Sep 2019.

Vancouver:

Vinha JCRd. Sistema de Torre de Refrigeração. [Internet] [Thesis]. Instituto Politécnico do Porto; 2010. [cited 2019 Sep 20]. Available from: http://www.rcaap.pt/detail.jsp?id=oai:recipp.ipp.pt:10400.22/4409.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Vinha JCRd. Sistema de Torre de Refrigeração. [Thesis]. Instituto Politécnico do Porto; 2010. Available from: http://www.rcaap.pt/detail.jsp?id=oai:recipp.ipp.pt:10400.22/4409

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


North-West University

23. Van Rooyen, Kathryn Marie-Louise. The effect of condenser backpressure on station thermal efficiency : Grootvlei Power Station as a case study / Kathryn Marie-Louise van Rooyen .

Degree: 2014, North-West University

 Grootvlei Power Station’s thermal efficiency had been on a steady declining trend since it was re-commissioned in 2008, which had tremendous financial implications to the… (more)

Subjects/Keywords: Condenser performance; Thermal efficiency; Temperature gradient; Terminal temperature difference; Condensate depression; Temperature rise; Condenser efficiency analysis; Cooling tower performance

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Van Rooyen, K. M. (2014). The effect of condenser backpressure on station thermal efficiency : Grootvlei Power Station as a case study / Kathryn Marie-Louise van Rooyen . (Thesis). North-West University. Retrieved from http://hdl.handle.net/10394/15719

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Van Rooyen, Kathryn Marie-Louise. “The effect of condenser backpressure on station thermal efficiency : Grootvlei Power Station as a case study / Kathryn Marie-Louise van Rooyen .” 2014. Thesis, North-West University. Accessed September 20, 2019. http://hdl.handle.net/10394/15719.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Van Rooyen, Kathryn Marie-Louise. “The effect of condenser backpressure on station thermal efficiency : Grootvlei Power Station as a case study / Kathryn Marie-Louise van Rooyen .” 2014. Web. 20 Sep 2019.

Vancouver:

Van Rooyen KM. The effect of condenser backpressure on station thermal efficiency : Grootvlei Power Station as a case study / Kathryn Marie-Louise van Rooyen . [Internet] [Thesis]. North-West University; 2014. [cited 2019 Sep 20]. Available from: http://hdl.handle.net/10394/15719.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Van Rooyen KM. The effect of condenser backpressure on station thermal efficiency : Grootvlei Power Station as a case study / Kathryn Marie-Louise van Rooyen . [Thesis]. North-West University; 2014. Available from: http://hdl.handle.net/10394/15719

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of South Carolina

24. Maxwell, Ryan Matthew. Improving Cooling Tower Chemistry Control And Cost Savings Through Automation.

Degree: MS, 2016, University of South Carolina

  Proper chemistry control of cooling towers reduces corrosion, biological growth, and precipitation of solids. Therefore, improving control can lead to increased equipment life, operating… (more)

Subjects/Keywords: Business; Business Administration, Management, and Operations; Engineering; Other Engineering; Improving; Cooling Tower; Chemistry Control; Cost Savings; Automation

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Maxwell, R. M. (2016). Improving Cooling Tower Chemistry Control And Cost Savings Through Automation. (Masters Thesis). University of South Carolina. Retrieved from https://scholarcommons.sc.edu/etd/3875

Chicago Manual of Style (16th Edition):

Maxwell, Ryan Matthew. “Improving Cooling Tower Chemistry Control And Cost Savings Through Automation.” 2016. Masters Thesis, University of South Carolina. Accessed September 20, 2019. https://scholarcommons.sc.edu/etd/3875.

MLA Handbook (7th Edition):

Maxwell, Ryan Matthew. “Improving Cooling Tower Chemistry Control And Cost Savings Through Automation.” 2016. Web. 20 Sep 2019.

Vancouver:

Maxwell RM. Improving Cooling Tower Chemistry Control And Cost Savings Through Automation. [Internet] [Masters thesis]. University of South Carolina; 2016. [cited 2019 Sep 20]. Available from: https://scholarcommons.sc.edu/etd/3875.

Council of Science Editors:

Maxwell RM. Improving Cooling Tower Chemistry Control And Cost Savings Through Automation. [Masters Thesis]. University of South Carolina; 2016. Available from: https://scholarcommons.sc.edu/etd/3875


Brno University of Technology

25. Dobiáš, Radek. Řešení technologie součásti chladicí věže .

Degree: 2012, Brno University of Technology

 Obsahem této diplomové práce je řešení výroby součásti z chladicí věže. Je navržen model chladicí věže dle specifikace zákazníka. Z ocelové konstrukce jsou vybrány 2… (more)

Subjects/Keywords: chladicí věž; plazmové řezání; technologie; deska; finanční náklady; cooling tower; plasma cutting; technology; plate; financial costs

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Dobiáš, R. (2012). Řešení technologie součásti chladicí věže . (Thesis). Brno University of Technology. Retrieved from http://hdl.handle.net/11012/7915

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Dobiáš, Radek. “Řešení technologie součásti chladicí věže .” 2012. Thesis, Brno University of Technology. Accessed September 20, 2019. http://hdl.handle.net/11012/7915.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Dobiáš, Radek. “Řešení technologie součásti chladicí věže .” 2012. Web. 20 Sep 2019.

Vancouver:

Dobiáš R. Řešení technologie součásti chladicí věže . [Internet] [Thesis]. Brno University of Technology; 2012. [cited 2019 Sep 20]. Available from: http://hdl.handle.net/11012/7915.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Dobiáš R. Řešení technologie součásti chladicí věže . [Thesis]. Brno University of Technology; 2012. Available from: http://hdl.handle.net/11012/7915

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Brno University of Technology

26. Veselský, Marek. Klimatická data pro klimatizaci .

Degree: 2016, Brno University of Technology

 Předmětem diplomové práce je spracování klimatických údajú a návrh chladícího zařízení. Chladící zařízení je navrženo ve dvou variantách: bloková chladící jednota a chladící jednotka s… (more)

Subjects/Keywords: klimatické data; bloková chladící jednotka; chladící jednotka s otevřenou chladící věží; climate data; air-cooled chiller; chiller with open cooling tower

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Veselský, M. (2016). Klimatická data pro klimatizaci . (Thesis). Brno University of Technology. Retrieved from http://hdl.handle.net/11012/57549

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Veselský, Marek. “Klimatická data pro klimatizaci .” 2016. Thesis, Brno University of Technology. Accessed September 20, 2019. http://hdl.handle.net/11012/57549.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Veselský, Marek. “Klimatická data pro klimatizaci .” 2016. Web. 20 Sep 2019.

Vancouver:

Veselský M. Klimatická data pro klimatizaci . [Internet] [Thesis]. Brno University of Technology; 2016. [cited 2019 Sep 20]. Available from: http://hdl.handle.net/11012/57549.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Veselský M. Klimatická data pro klimatizaci . [Thesis]. Brno University of Technology; 2016. Available from: http://hdl.handle.net/11012/57549

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

27. Oikawa, Eduardo Hiroshi. Avaliação de um sistema industrial de resfriamento de água.

Degree: Mestrado, Engenharia Química, 2012, University of São Paulo

Neste trabalho, foi estudado o desempenho de um sistema constituído de torres de resfriamento e a sua integração em uma planta industrial de hidrogenação de… (more)

Subjects/Keywords: Análise de processo; Cooling tower; Cooling water system; Heat and mass transfer; Integração de processo; Mathematical modeling; Process analysis; Torre de resfriamento de água; Transferência de calor e massa

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Oikawa, E. H. (2012). Avaliação de um sistema industrial de resfriamento de água. (Masters Thesis). University of São Paulo. Retrieved from http://www.teses.usp.br/teses/disponiveis/3/3137/tde-16112012-114140/ ;

Chicago Manual of Style (16th Edition):

Oikawa, Eduardo Hiroshi. “Avaliação de um sistema industrial de resfriamento de água.” 2012. Masters Thesis, University of São Paulo. Accessed September 20, 2019. http://www.teses.usp.br/teses/disponiveis/3/3137/tde-16112012-114140/ ;.

MLA Handbook (7th Edition):

Oikawa, Eduardo Hiroshi. “Avaliação de um sistema industrial de resfriamento de água.” 2012. Web. 20 Sep 2019.

Vancouver:

Oikawa EH. Avaliação de um sistema industrial de resfriamento de água. [Internet] [Masters thesis]. University of São Paulo; 2012. [cited 2019 Sep 20]. Available from: http://www.teses.usp.br/teses/disponiveis/3/3137/tde-16112012-114140/ ;.

Council of Science Editors:

Oikawa EH. Avaliação de um sistema industrial de resfriamento de água. [Masters Thesis]. University of São Paulo; 2012. Available from: http://www.teses.usp.br/teses/disponiveis/3/3137/tde-16112012-114140/ ;

28. Rodrigues, Pedro Eduardo Ferreira. Otimização da torre de arrefecimento da Artlant PTA.

Degree: 2015, Repositório Científico do Instituto Politécnico de Lisboa

Trabalho Final de Mestrado para obtenção de grau de Mestre em Engenharia Química e Biológica

Este trabalho teve como objetivo uma análise e proposta de… (more)

Subjects/Keywords: Ácido tereftálico purificado; Torre de arrefecimento; Temperatura de água de arrefecimento; Turbina de vapor; Purified terephtalic acid; Cooling tower; Cooling water temperature; Steam turbine

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Rodrigues, P. E. F. (2015). Otimização da torre de arrefecimento da Artlant PTA. (Thesis). Repositório Científico do Instituto Politécnico de Lisboa. Retrieved from http://www.rcaap.pt/detail.jsp?id=oai:repositorio.ipl.pt:10400.21/5603

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Rodrigues, Pedro Eduardo Ferreira. “Otimização da torre de arrefecimento da Artlant PTA.” 2015. Thesis, Repositório Científico do Instituto Politécnico de Lisboa. Accessed September 20, 2019. http://www.rcaap.pt/detail.jsp?id=oai:repositorio.ipl.pt:10400.21/5603.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Rodrigues, Pedro Eduardo Ferreira. “Otimização da torre de arrefecimento da Artlant PTA.” 2015. Web. 20 Sep 2019.

Vancouver:

Rodrigues PEF. Otimização da torre de arrefecimento da Artlant PTA. [Internet] [Thesis]. Repositório Científico do Instituto Politécnico de Lisboa; 2015. [cited 2019 Sep 20]. Available from: http://www.rcaap.pt/detail.jsp?id=oai:repositorio.ipl.pt:10400.21/5603.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Rodrigues PEF. Otimização da torre de arrefecimento da Artlant PTA. [Thesis]. Repositório Científico do Instituto Politécnico de Lisboa; 2015. Available from: http://www.rcaap.pt/detail.jsp?id=oai:repositorio.ipl.pt:10400.21/5603

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Universidade Nova

29. Cardoso, Ana Margarete Sousa. Legionella em meio hospitalar : qual a eficácia dos programas de prevenção nos hospitais da Região de Lisboa e Vale do Tejo : manutenção, limpeza e desinfeção de sistemas e.

Degree: 2013, Universidade Nova

RESUMO - A legionella em meio hospitalar tem sido alvo de preocupação e de várias discussões, sendo esta uma bactéria patogénica que coloniza vários tipos… (more)

Subjects/Keywords: Legionella; Febre de Pontiac; Programas de prevenção; Sistemas de arrefecimento de ar; torre de arrefecimento; Legionella; Pontiac’s fever; preventing programs; air cooling systems; cooling tower

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Cardoso, A. M. S. (2013). Legionella em meio hospitalar : qual a eficácia dos programas de prevenção nos hospitais da Região de Lisboa e Vale do Tejo : manutenção, limpeza e desinfeção de sistemas e. (Thesis). Universidade Nova. Retrieved from http://www.rcaap.pt/detail.jsp?id=oai:run.unl.pt:10362/10088

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Cardoso, Ana Margarete Sousa. “Legionella em meio hospitalar : qual a eficácia dos programas de prevenção nos hospitais da Região de Lisboa e Vale do Tejo : manutenção, limpeza e desinfeção de sistemas e.” 2013. Thesis, Universidade Nova. Accessed September 20, 2019. http://www.rcaap.pt/detail.jsp?id=oai:run.unl.pt:10362/10088.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Cardoso, Ana Margarete Sousa. “Legionella em meio hospitalar : qual a eficácia dos programas de prevenção nos hospitais da Região de Lisboa e Vale do Tejo : manutenção, limpeza e desinfeção de sistemas e.” 2013. Web. 20 Sep 2019.

Vancouver:

Cardoso AMS. Legionella em meio hospitalar : qual a eficácia dos programas de prevenção nos hospitais da Região de Lisboa e Vale do Tejo : manutenção, limpeza e desinfeção de sistemas e. [Internet] [Thesis]. Universidade Nova; 2013. [cited 2019 Sep 20]. Available from: http://www.rcaap.pt/detail.jsp?id=oai:run.unl.pt:10362/10088.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Cardoso AMS. Legionella em meio hospitalar : qual a eficácia dos programas de prevenção nos hospitais da Região de Lisboa e Vale do Tejo : manutenção, limpeza e desinfeção de sistemas e. [Thesis]. Universidade Nova; 2013. Available from: http://www.rcaap.pt/detail.jsp?id=oai:run.unl.pt:10362/10088

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Brno University of Technology

30. Susna, David. Návrh chladícího okruhu pro odvod tepla z kondenzátoru parní turbíny .

Degree: 2018, Brno University of Technology

 Diplomová práce se zabývá problematikou vyvedení zbytkového nízkopotenciálního tepla z kondenzátoru parní turbíny a jeho mařením. V teoretické části práce jsou nejdříve popsány různé druhy… (more)

Subjects/Keywords: Chladící okruh; mokrá chladící věž; suchý chladič; přirozený tah; nucený tah; voda; propylen glykol; Cooling cycle; wet cooling tower; dry chiller; natural draft; forced draft; water; propylene glycol

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Susna, D. (2018). Návrh chladícího okruhu pro odvod tepla z kondenzátoru parní turbíny . (Thesis). Brno University of Technology. Retrieved from http://hdl.handle.net/11012/82671

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Susna, David. “Návrh chladícího okruhu pro odvod tepla z kondenzátoru parní turbíny .” 2018. Thesis, Brno University of Technology. Accessed September 20, 2019. http://hdl.handle.net/11012/82671.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Susna, David. “Návrh chladícího okruhu pro odvod tepla z kondenzátoru parní turbíny .” 2018. Web. 20 Sep 2019.

Vancouver:

Susna D. Návrh chladícího okruhu pro odvod tepla z kondenzátoru parní turbíny . [Internet] [Thesis]. Brno University of Technology; 2018. [cited 2019 Sep 20]. Available from: http://hdl.handle.net/11012/82671.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Susna D. Návrh chladícího okruhu pro odvod tepla z kondenzátoru parní turbíny . [Thesis]. Brno University of Technology; 2018. Available from: http://hdl.handle.net/11012/82671

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

[1] [2]

.