You searched for subject:(composite insulators). Showing records 1 – 8 of 8 total matches.

Search Limiters

Last 2 Years | English Only

No search limiters apply to these results.

▼ Search Limiters


University of Manchester

1. Da Silva domingues, Elizabeth. Improved Condition Monitoring of Composite Insulators.

Degree: 2012, University of Manchester

 Although the cost of investment in power lines insulators is 3 - 5% of the total cost of the installation, the impact of their performance… (more)

Subjects/Keywords: composite insulators; ageing; early stages; water droplets; electric field; corona discharges

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Da Silva domingues, E. (2012). Improved Condition Monitoring of Composite Insulators. (Doctoral Dissertation). University of Manchester. Retrieved from http://www.manchester.ac.uk/escholar/uk-ac-man-scw:156246

Chicago Manual of Style (16th Edition):

Da Silva domingues, Elizabeth. “Improved Condition Monitoring of Composite Insulators.” 2012. Doctoral Dissertation, University of Manchester. Accessed January 18, 2020. http://www.manchester.ac.uk/escholar/uk-ac-man-scw:156246.

MLA Handbook (7th Edition):

Da Silva domingues, Elizabeth. “Improved Condition Monitoring of Composite Insulators.” 2012. Web. 18 Jan 2020.

Vancouver:

Da Silva domingues E. Improved Condition Monitoring of Composite Insulators. [Internet] [Doctoral dissertation]. University of Manchester; 2012. [cited 2020 Jan 18]. Available from: http://www.manchester.ac.uk/escholar/uk-ac-man-scw:156246.

Council of Science Editors:

Da Silva domingues E. Improved Condition Monitoring of Composite Insulators. [Doctoral Dissertation]. University of Manchester; 2012. Available from: http://www.manchester.ac.uk/escholar/uk-ac-man-scw:156246


University of Manchester

2. Da Silva domingues, Elizabeth. Improved condition monitoring of composite insulators.

Degree: PhD, 2012, University of Manchester

 Although the cost of investment in power lines insulators is 3-5% of the total cost of the installation, the impact of their performance on reliability,… (more)

Subjects/Keywords: 621.31937; composite insulators; ageing; early stages; water droplets; electric field; corona discharges

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Da Silva domingues, E. (2012). Improved condition monitoring of composite insulators. (Doctoral Dissertation). University of Manchester. Retrieved from https://www.research.manchester.ac.uk/portal/en/theses/improved-condition-monitoring-of-composite-insulators(d42e15fb-d9c2-4e45-94b9-3321e9d9b9f0).html ; https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.553396

Chicago Manual of Style (16th Edition):

Da Silva domingues, Elizabeth. “Improved condition monitoring of composite insulators.” 2012. Doctoral Dissertation, University of Manchester. Accessed January 18, 2020. https://www.research.manchester.ac.uk/portal/en/theses/improved-condition-monitoring-of-composite-insulators(d42e15fb-d9c2-4e45-94b9-3321e9d9b9f0).html ; https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.553396.

MLA Handbook (7th Edition):

Da Silva domingues, Elizabeth. “Improved condition monitoring of composite insulators.” 2012. Web. 18 Jan 2020.

Vancouver:

Da Silva domingues E. Improved condition monitoring of composite insulators. [Internet] [Doctoral dissertation]. University of Manchester; 2012. [cited 2020 Jan 18]. Available from: https://www.research.manchester.ac.uk/portal/en/theses/improved-condition-monitoring-of-composite-insulators(d42e15fb-d9c2-4e45-94b9-3321e9d9b9f0).html ; https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.553396.

Council of Science Editors:

Da Silva domingues E. Improved condition monitoring of composite insulators. [Doctoral Dissertation]. University of Manchester; 2012. Available from: https://www.research.manchester.ac.uk/portal/en/theses/improved-condition-monitoring-of-composite-insulators(d42e15fb-d9c2-4e45-94b9-3321e9d9b9f0).html ; https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.553396


Brno University of Technology

3. Dovčík, František. Testování izolátorů .

Degree: 2014, Brno University of Technology

 Práca „Testování izolátorů“ sa zaoberá izolátormi a metódami používanými pri ich vysokonapäťovom testovaní. Práca bola vytvorená podľa platných noriem týkajúcich sa testovania, predovšetkým ČSN EN… (more)

Subjects/Keywords: testovanie izolátoru; izolátory; kompozitné izolátory; tyčové izolátory; porcelánové izolátory; sklenené izolátory; rázová charakteristika; atmosférické impulzné napätie; normalizovaný atmosférický impulz; testing insulators; composite insulator; long rod insulators; ceramic insulators; glass insulators; time lag characteristic; lightning impulse voltage; standardized lightning impulse

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Dovčík, F. (2014). Testování izolátorů . (Thesis). Brno University of Technology. Retrieved from http://hdl.handle.net/11012/34350

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Dovčík, František. “Testování izolátorů .” 2014. Thesis, Brno University of Technology. Accessed January 18, 2020. http://hdl.handle.net/11012/34350.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Dovčík, František. “Testování izolátorů .” 2014. Web. 18 Jan 2020.

Vancouver:

Dovčík F. Testování izolátorů . [Internet] [Thesis]. Brno University of Technology; 2014. [cited 2020 Jan 18]. Available from: http://hdl.handle.net/11012/34350.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Dovčík F. Testování izolátorů . [Thesis]. Brno University of Technology; 2014. Available from: http://hdl.handle.net/11012/34350

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

4. Bo, Lin. Modeling Flashover of AC Outdoor Insulators under Contaminated Conditions with Dry Band Formation and Arcing.

Degree: MS, Electrical Engineering, 2012, Arizona State University

 This paper presents a theoretical model for evaluating flashover performance of insulators under contaminated conditions. The model introduces several new features when compared with existing… (more)

Subjects/Keywords: Electrical engineering; composite insulators; contamination performance; EPDM; porcelain insulators; silicone rubber; surface hydrophobicity

…porcelain. Polymeric 3 insulators are also known as composite and nonceramic insulators… …even in wet and contaminated environments. Composite insulators are lighter and are… …composite materials is high and such insulators are not easily wetted. However, composite… …properties of composite insulators can change. In other words, the insulator will “age”. Hence, the… …insulators. All materials undergo aging. It is more common to talk about aging with composite… 

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Bo, L. (2012). Modeling Flashover of AC Outdoor Insulators under Contaminated Conditions with Dry Band Formation and Arcing. (Masters Thesis). Arizona State University. Retrieved from http://repository.asu.edu/items/14536

Chicago Manual of Style (16th Edition):

Bo, Lin. “Modeling Flashover of AC Outdoor Insulators under Contaminated Conditions with Dry Band Formation and Arcing.” 2012. Masters Thesis, Arizona State University. Accessed January 18, 2020. http://repository.asu.edu/items/14536.

MLA Handbook (7th Edition):

Bo, Lin. “Modeling Flashover of AC Outdoor Insulators under Contaminated Conditions with Dry Band Formation and Arcing.” 2012. Web. 18 Jan 2020.

Vancouver:

Bo L. Modeling Flashover of AC Outdoor Insulators under Contaminated Conditions with Dry Band Formation and Arcing. [Internet] [Masters thesis]. Arizona State University; 2012. [cited 2020 Jan 18]. Available from: http://repository.asu.edu/items/14536.

Council of Science Editors:

Bo L. Modeling Flashover of AC Outdoor Insulators under Contaminated Conditions with Dry Band Formation and Arcing. [Masters Thesis]. Arizona State University; 2012. Available from: http://repository.asu.edu/items/14536


University of KwaZulu-Natal

5. [No author]. Determination of dynamic loads caused by aeolian vibration on composite insulator : experimental approach.

Degree: Mechanical engineering, 2015, University of KwaZulu-Natal

 High voltage insulators have to fulfil high reliability criteria by being one of the main components for the operational safety and operating efficiency of the… (more)

Subjects/Keywords: Electric insulators and insulation – Vibration.; Flutter (Aerodynamics); Electric conductors.; Electric conductors – Vibration.; Overhead electric lines – Vibration.; Mechanical engineering.; Aeolian vibration.; Composite insulator.

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

author], [. (2015). Determination of dynamic loads caused by aeolian vibration on composite insulator : experimental approach. (Thesis). University of KwaZulu-Natal. Retrieved from http://hdl.handle.net/10413/13276

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

author], [No. “Determination of dynamic loads caused by aeolian vibration on composite insulator : experimental approach. ” 2015. Thesis, University of KwaZulu-Natal. Accessed January 18, 2020. http://hdl.handle.net/10413/13276.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

author], [No. “Determination of dynamic loads caused by aeolian vibration on composite insulator : experimental approach. ” 2015. Web. 18 Jan 2020.

Vancouver:

author] [. Determination of dynamic loads caused by aeolian vibration on composite insulator : experimental approach. [Internet] [Thesis]. University of KwaZulu-Natal; 2015. [cited 2020 Jan 18]. Available from: http://hdl.handle.net/10413/13276.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

author] [. Determination of dynamic loads caused by aeolian vibration on composite insulator : experimental approach. [Thesis]. University of KwaZulu-Natal; 2015. Available from: http://hdl.handle.net/10413/13276

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Queensland University of Technology

6. Sovar, Robert D. Novel analytical techniques for the assessment of degradation of silicone elastomers in high voltage applications.

Degree: 2005, Queensland University of Technology

 Over the last 20 years "composite" insulators have been increasingly used in high voltage applications as an alternative traditional materials. More recently, polydimethylsiloxane (PDMS) have… (more)

Subjects/Keywords: Composite insulators; polydimethylsiloxane (PDMS); low molecular weight silicone oil (LMWS); polydimethlysiloxane high-voltage insulators; Contact Angle DRIFT Electrostatic Deposition (CADED); hydrophobicity; Silicone Elastomers; high voltage; applications

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Sovar, R. D. (2005). Novel analytical techniques for the assessment of degradation of silicone elastomers in high voltage applications. (Thesis). Queensland University of Technology. Retrieved from https://eprints.qut.edu.au/16072/

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Sovar, Robert D. “Novel analytical techniques for the assessment of degradation of silicone elastomers in high voltage applications.” 2005. Thesis, Queensland University of Technology. Accessed January 18, 2020. https://eprints.qut.edu.au/16072/.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Sovar, Robert D. “Novel analytical techniques for the assessment of degradation of silicone elastomers in high voltage applications.” 2005. Web. 18 Jan 2020.

Vancouver:

Sovar RD. Novel analytical techniques for the assessment of degradation of silicone elastomers in high voltage applications. [Internet] [Thesis]. Queensland University of Technology; 2005. [cited 2020 Jan 18]. Available from: https://eprints.qut.edu.au/16072/.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Sovar RD. Novel analytical techniques for the assessment of degradation of silicone elastomers in high voltage applications. [Thesis]. Queensland University of Technology; 2005. Available from: https://eprints.qut.edu.au/16072/

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Indian Institute of Science

7. Singha, Santanu. Studies On The Dielectric And Electrical Insulation Properties Of Polymer Nanocomposites.

Degree: 2008, Indian Institute of Science

 Today, nanotechnology has added a new dimension to materials technology by creating opportunities to significantly enhance the properties of existing conventional materials. Polymer nanocomposites belong… (more)

Subjects/Keywords: Polymer Nanocomposites; Electric Insulation; Insulators And Insulations; Nanodielectrics; Polymer Nanocomposites - Dielectric Properties; Epoxy Nanocomposites - Dielectric Properties; Nanocomposite Interface Dynamics; Electrical Insulation Systems; Electrical Insulating Materials; Polymer Composite; Nanocomposite Processing; Nano-filler Loadings; Electrical Engineering

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Singha, S. (2008). Studies On The Dielectric And Electrical Insulation Properties Of Polymer Nanocomposites. (Thesis). Indian Institute of Science. Retrieved from http://hdl.handle.net/2005/842

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Singha, Santanu. “Studies On The Dielectric And Electrical Insulation Properties Of Polymer Nanocomposites.” 2008. Thesis, Indian Institute of Science. Accessed January 18, 2020. http://hdl.handle.net/2005/842.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Singha, Santanu. “Studies On The Dielectric And Electrical Insulation Properties Of Polymer Nanocomposites.” 2008. Web. 18 Jan 2020.

Vancouver:

Singha S. Studies On The Dielectric And Electrical Insulation Properties Of Polymer Nanocomposites. [Internet] [Thesis]. Indian Institute of Science; 2008. [cited 2020 Jan 18]. Available from: http://hdl.handle.net/2005/842.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Singha S. Studies On The Dielectric And Electrical Insulation Properties Of Polymer Nanocomposites. [Thesis]. Indian Institute of Science; 2008. Available from: http://hdl.handle.net/2005/842

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Queensland University of Technology

8. Blackmore, Paul David. Degradation of polymeric outdoor high voltage insulation : surface discharge phenomena and condition assessment techniques.

Degree: 1997, Queensland University of Technology

Subjects/Keywords: Fourier transform infrared spectroscopy; Electric insulators and insulation Polymers Testing; electrical insulation; high voltage outdoor insulation; polymeric insulation; non-ceramic insulation; composite insulators; EPDM; silicone; ageing; degradation; condition monitoring; Fourier transform infrared spectroscopy; FTIR; Xray photoelectron spectroscopy; XPS; chalking index; oxidation index; electrical discharge; glow discharge; atmospheric pressure; electrolyte; thesis; doctoral

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Blackmore, P. D. (1997). Degradation of polymeric outdoor high voltage insulation : surface discharge phenomena and condition assessment techniques. (Thesis). Queensland University of Technology. Retrieved from http://eprints.qut.edu.au/36051/

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Blackmore, Paul David. “Degradation of polymeric outdoor high voltage insulation : surface discharge phenomena and condition assessment techniques.” 1997. Thesis, Queensland University of Technology. Accessed January 18, 2020. http://eprints.qut.edu.au/36051/.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Blackmore, Paul David. “Degradation of polymeric outdoor high voltage insulation : surface discharge phenomena and condition assessment techniques.” 1997. Web. 18 Jan 2020.

Vancouver:

Blackmore PD. Degradation of polymeric outdoor high voltage insulation : surface discharge phenomena and condition assessment techniques. [Internet] [Thesis]. Queensland University of Technology; 1997. [cited 2020 Jan 18]. Available from: http://eprints.qut.edu.au/36051/.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Blackmore PD. Degradation of polymeric outdoor high voltage insulation : surface discharge phenomena and condition assessment techniques. [Thesis]. Queensland University of Technology; 1997. Available from: http://eprints.qut.edu.au/36051/

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

.