Advanced search options

Advanced Search Options 🞨

Browse by author name (“Author name starts with…”).

Find ETDs with:

in
/  
in
/  
in
/  
in

Written in Published in Earliest date Latest date

Sorted by

Results per page:

Sorted by: relevance · author · university · dateNew search

You searched for subject:(Stents Surgery ). Showing records 1 – 30 of 31 total matches.

[1] [2]

Search Limiters

Last 2 Years | English Only

▼ Search Limiters

1. Karman, Kristen. 2-D CFD design of the cross-sectional shape of arterial stents.

Degree: 2013, University of Tennessee – Chattanooga

 An approach for desigining arterial stents to maximize wall shear stress is presented. A cost equation to maximize wall shear stress is derived and then… (more)

Subjects/Keywords: Stents (Surgery); Stents (Surgery)  – Fluid dynamics

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Karman, K. (2013). 2-D CFD design of the cross-sectional shape of arterial stents. (Masters Thesis). University of Tennessee – Chattanooga. Retrieved from https://scholar.utc.edu/theses/97

Chicago Manual of Style (16th Edition):

Karman, Kristen. “2-D CFD design of the cross-sectional shape of arterial stents.” 2013. Masters Thesis, University of Tennessee – Chattanooga. Accessed March 01, 2021. https://scholar.utc.edu/theses/97.

MLA Handbook (7th Edition):

Karman, Kristen. “2-D CFD design of the cross-sectional shape of arterial stents.” 2013. Web. 01 Mar 2021.

Vancouver:

Karman K. 2-D CFD design of the cross-sectional shape of arterial stents. [Internet] [Masters thesis]. University of Tennessee – Chattanooga; 2013. [cited 2021 Mar 01]. Available from: https://scholar.utc.edu/theses/97.

Council of Science Editors:

Karman K. 2-D CFD design of the cross-sectional shape of arterial stents. [Masters Thesis]. University of Tennessee – Chattanooga; 2013. Available from: https://scholar.utc.edu/theses/97


Rutgers University

2. Chan, Jennifer Wing-Yee. Design, fabrication, and characterization of bioactive amphiphilic polymers as cardiovascular therapeutics.

Degree: PhD, Biomedical Engineering, 2016, Rutgers University

Recent advancements in cardiovascular drug-eluting stents (DES) have significantly improved clinical outcomes and survival rates in patients with arteries blocked by fat and cholesterol accumulation.… (more)

Subjects/Keywords: Stents (Surgery); Macromolecules

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Chan, J. W. (2016). Design, fabrication, and characterization of bioactive amphiphilic polymers as cardiovascular therapeutics. (Doctoral Dissertation). Rutgers University. Retrieved from https://rucore.libraries.rutgers.edu/rutgers-lib/49920/

Chicago Manual of Style (16th Edition):

Chan, Jennifer Wing-Yee. “Design, fabrication, and characterization of bioactive amphiphilic polymers as cardiovascular therapeutics.” 2016. Doctoral Dissertation, Rutgers University. Accessed March 01, 2021. https://rucore.libraries.rutgers.edu/rutgers-lib/49920/.

MLA Handbook (7th Edition):

Chan, Jennifer Wing-Yee. “Design, fabrication, and characterization of bioactive amphiphilic polymers as cardiovascular therapeutics.” 2016. Web. 01 Mar 2021.

Vancouver:

Chan JW. Design, fabrication, and characterization of bioactive amphiphilic polymers as cardiovascular therapeutics. [Internet] [Doctoral dissertation]. Rutgers University; 2016. [cited 2021 Mar 01]. Available from: https://rucore.libraries.rutgers.edu/rutgers-lib/49920/.

Council of Science Editors:

Chan JW. Design, fabrication, and characterization of bioactive amphiphilic polymers as cardiovascular therapeutics. [Doctoral Dissertation]. Rutgers University; 2016. Available from: https://rucore.libraries.rutgers.edu/rutgers-lib/49920/


Oregon State University

3. Bergman, Joshua J. Determining the activity distribution on a radioactive stent using plastic scintillation techniques.

Degree: MS, Radiation Health Physics, 2000, Oregon State University

 Re-occlusion of arteries following percutaneous transluminal coronary angioplasty (PTCA) remains a post-operative issue in the treatment of artery blockage. This re-narrowing of the luminal cavity,… (more)

Subjects/Keywords: Stents (Surgery)

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Bergman, J. J. (2000). Determining the activity distribution on a radioactive stent using plastic scintillation techniques. (Masters Thesis). Oregon State University. Retrieved from http://hdl.handle.net/1957/32951

Chicago Manual of Style (16th Edition):

Bergman, Joshua J. “Determining the activity distribution on a radioactive stent using plastic scintillation techniques.” 2000. Masters Thesis, Oregon State University. Accessed March 01, 2021. http://hdl.handle.net/1957/32951.

MLA Handbook (7th Edition):

Bergman, Joshua J. “Determining the activity distribution on a radioactive stent using plastic scintillation techniques.” 2000. Web. 01 Mar 2021.

Vancouver:

Bergman JJ. Determining the activity distribution on a radioactive stent using plastic scintillation techniques. [Internet] [Masters thesis]. Oregon State University; 2000. [cited 2021 Mar 01]. Available from: http://hdl.handle.net/1957/32951.

Council of Science Editors:

Bergman JJ. Determining the activity distribution on a radioactive stent using plastic scintillation techniques. [Masters Thesis]. Oregon State University; 2000. Available from: http://hdl.handle.net/1957/32951


Durban University of Technology

4. Harrypaul, Ashika. The assessment of two year clinical outcomes after stent implantation for the treatment of coronary artery disease.

Degree: 2013, Durban University of Technology

Submitted in fulfilment of the Master’s Degree in Clinical Technology, Durban University of Technology, 2012.

The sirolimus-eluting stent (Cypher) was the first approved drug- eluting… (more)

Subjects/Keywords: Stents (Surgery); Coronary heart disease – Treatment; Cardiology

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Harrypaul, A. (2013). The assessment of two year clinical outcomes after stent implantation for the treatment of coronary artery disease. (Thesis). Durban University of Technology. Retrieved from http://hdl.handle.net/10321/812

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Harrypaul, Ashika. “The assessment of two year clinical outcomes after stent implantation for the treatment of coronary artery disease.” 2013. Thesis, Durban University of Technology. Accessed March 01, 2021. http://hdl.handle.net/10321/812.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Harrypaul, Ashika. “The assessment of two year clinical outcomes after stent implantation for the treatment of coronary artery disease.” 2013. Web. 01 Mar 2021.

Vancouver:

Harrypaul A. The assessment of two year clinical outcomes after stent implantation for the treatment of coronary artery disease. [Internet] [Thesis]. Durban University of Technology; 2013. [cited 2021 Mar 01]. Available from: http://hdl.handle.net/10321/812.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Harrypaul A. The assessment of two year clinical outcomes after stent implantation for the treatment of coronary artery disease. [Thesis]. Durban University of Technology; 2013. Available from: http://hdl.handle.net/10321/812

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Drexel University

5. Thompson, Patrick Robert. Performance leakage for biospan-covered electrospun vascular stents in a pulsatile flow bioreactor.

Degree: 2014, Drexel University

In-stent restenosis occurs in 15-20% of “simple” coronary lesions, and in 30-60% of patients with complex lesions. Covered-stents reduce the rates of in-stent restenosis by… (more)

Subjects/Keywords: Biomedical engineering; Stents (Surgery); Blood flow

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Thompson, P. R. (2014). Performance leakage for biospan-covered electrospun vascular stents in a pulsatile flow bioreactor. (Thesis). Drexel University. Retrieved from http://hdl.handle.net/1860/idea:6079

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Thompson, Patrick Robert. “Performance leakage for biospan-covered electrospun vascular stents in a pulsatile flow bioreactor.” 2014. Thesis, Drexel University. Accessed March 01, 2021. http://hdl.handle.net/1860/idea:6079.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Thompson, Patrick Robert. “Performance leakage for biospan-covered electrospun vascular stents in a pulsatile flow bioreactor.” 2014. Web. 01 Mar 2021.

Vancouver:

Thompson PR. Performance leakage for biospan-covered electrospun vascular stents in a pulsatile flow bioreactor. [Internet] [Thesis]. Drexel University; 2014. [cited 2021 Mar 01]. Available from: http://hdl.handle.net/1860/idea:6079.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Thompson PR. Performance leakage for biospan-covered electrospun vascular stents in a pulsatile flow bioreactor. [Thesis]. Drexel University; 2014. Available from: http://hdl.handle.net/1860/idea:6079

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

6. Halwani, Dina O. Characterization of explanted endovascular stents : a study of in-vivo corrosion and the role of vascular calcification in stent fracture.

Degree: PhD, 2010, University of Alabama – Birmingham

The electrochemical and mechanical stability of endovascular stents in-vivo is essential for their biocompatibility. Limited information is available regarding the condition of stents following interaction… (more)

Subjects/Keywords: Stents (Surgery)  – Materials  – Corrosion <; br>; Stents (Surgery)  – Materials  – Fracture <; br>; Stents (Surgery)  – Materials  – Biocompatibility <; br>; Blood-vessels  – Calcification <; br>; Blood-vessels  – Diseases

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Halwani, D. O. (2010). Characterization of explanted endovascular stents : a study of in-vivo corrosion and the role of vascular calcification in stent fracture. (Doctoral Dissertation). University of Alabama – Birmingham. Retrieved from http://contentdm.mhsl.uab.edu/u?/etd,815

Chicago Manual of Style (16th Edition):

Halwani, Dina O. “Characterization of explanted endovascular stents : a study of in-vivo corrosion and the role of vascular calcification in stent fracture.” 2010. Doctoral Dissertation, University of Alabama – Birmingham. Accessed March 01, 2021. http://contentdm.mhsl.uab.edu/u?/etd,815.

MLA Handbook (7th Edition):

Halwani, Dina O. “Characterization of explanted endovascular stents : a study of in-vivo corrosion and the role of vascular calcification in stent fracture.” 2010. Web. 01 Mar 2021.

Vancouver:

Halwani DO. Characterization of explanted endovascular stents : a study of in-vivo corrosion and the role of vascular calcification in stent fracture. [Internet] [Doctoral dissertation]. University of Alabama – Birmingham; 2010. [cited 2021 Mar 01]. Available from: http://contentdm.mhsl.uab.edu/u?/etd,815.

Council of Science Editors:

Halwani DO. Characterization of explanted endovascular stents : a study of in-vivo corrosion and the role of vascular calcification in stent fracture. [Doctoral Dissertation]. University of Alabama – Birmingham; 2010. Available from: http://contentdm.mhsl.uab.edu/u?/etd,815


University of Hong Kong

7. Leung, Kar-ming. Stent assisted coiling for wide-neck cerebral aneurysms.

Degree: 2009, University of Hong Kong

Subjects/Keywords: Intracranial aneurysms.; Stents (Surgery)

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Leung, K. (2009). Stent assisted coiling for wide-neck cerebral aneurysms. (Thesis). University of Hong Kong. Retrieved from http://hdl.handle.net/10722/56987

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Leung, Kar-ming. “Stent assisted coiling for wide-neck cerebral aneurysms.” 2009. Thesis, University of Hong Kong. Accessed March 01, 2021. http://hdl.handle.net/10722/56987.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Leung, Kar-ming. “Stent assisted coiling for wide-neck cerebral aneurysms.” 2009. Web. 01 Mar 2021.

Vancouver:

Leung K. Stent assisted coiling for wide-neck cerebral aneurysms. [Internet] [Thesis]. University of Hong Kong; 2009. [cited 2021 Mar 01]. Available from: http://hdl.handle.net/10722/56987.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Leung K. Stent assisted coiling for wide-neck cerebral aneurysms. [Thesis]. University of Hong Kong; 2009. Available from: http://hdl.handle.net/10722/56987

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Universidade Nova

8. Canena, Jorge Manuel Tavares . Próteses no tubo digestivo: evolução e aplicações no século XXI .

Degree: 2012, Universidade Nova

 RESUMO: A utilização das próteses metálicas auto-expansíveis é um tratamento paliativo e definitivo muito eficaz em doentes com obstrução maligna coló-retal e gastroduodenal. Este tratamento… (more)

Subjects/Keywords: Gastrointestinal Neoplasms - surgery; Endoscopy, Gastrointestinal - methods; Stents; Gastrenterologia

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Canena, J. M. T. (2012). Próteses no tubo digestivo: evolução e aplicações no século XXI . (Thesis). Universidade Nova. Retrieved from http://www.rcaap.pt/detail.jsp?id=oai:run.unl.pt:10362/7874

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Canena, Jorge Manuel Tavares . “Próteses no tubo digestivo: evolução e aplicações no século XXI .” 2012. Thesis, Universidade Nova. Accessed March 01, 2021. http://www.rcaap.pt/detail.jsp?id=oai:run.unl.pt:10362/7874.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Canena, Jorge Manuel Tavares . “Próteses no tubo digestivo: evolução e aplicações no século XXI .” 2012. Web. 01 Mar 2021.

Vancouver:

Canena JMT. Próteses no tubo digestivo: evolução e aplicações no século XXI . [Internet] [Thesis]. Universidade Nova; 2012. [cited 2021 Mar 01]. Available from: http://www.rcaap.pt/detail.jsp?id=oai:run.unl.pt:10362/7874.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Canena JMT. Próteses no tubo digestivo: evolução e aplicações no século XXI . [Thesis]. Universidade Nova; 2012. Available from: http://www.rcaap.pt/detail.jsp?id=oai:run.unl.pt:10362/7874

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Michigan State University

9. Rayepalli, Sagar. Experimental investigation of flow in a rectangular cavity with a porous opening.

Degree: MS, Department of Mechanical Engineering, 2007, Michigan State University

Subjects/Keywords: Stents (Surgery) – Fluid dynamics

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Rayepalli, S. (2007). Experimental investigation of flow in a rectangular cavity with a porous opening. (Masters Thesis). Michigan State University. Retrieved from http://etd.lib.msu.edu/islandora/object/etd:38776

Chicago Manual of Style (16th Edition):

Rayepalli, Sagar. “Experimental investigation of flow in a rectangular cavity with a porous opening.” 2007. Masters Thesis, Michigan State University. Accessed March 01, 2021. http://etd.lib.msu.edu/islandora/object/etd:38776.

MLA Handbook (7th Edition):

Rayepalli, Sagar. “Experimental investigation of flow in a rectangular cavity with a porous opening.” 2007. Web. 01 Mar 2021.

Vancouver:

Rayepalli S. Experimental investigation of flow in a rectangular cavity with a porous opening. [Internet] [Masters thesis]. Michigan State University; 2007. [cited 2021 Mar 01]. Available from: http://etd.lib.msu.edu/islandora/object/etd:38776.

Council of Science Editors:

Rayepalli S. Experimental investigation of flow in a rectangular cavity with a porous opening. [Masters Thesis]. Michigan State University; 2007. Available from: http://etd.lib.msu.edu/islandora/object/etd:38776


University of Hong Kong

10. 庆开雄. Thoracic endovascular stent graft repair (TEVAR) for treating type B aortic dissections (TBAD) : a hemodynamic and morphologic perspective.

Degree: 2013, University of Hong Kong

 TEVAR has been used extensively to treat TBAD. The principle of treatment involve placement of a stent graft in the true lumen to cover the… (more)

Subjects/Keywords: Stents (Surgery); Dissecting aortic aneurysms - Surgery

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

庆开雄. (2013). Thoracic endovascular stent graft repair (TEVAR) for treating type B aortic dissections (TBAD) : a hemodynamic and morphologic perspective. (Thesis). University of Hong Kong. Retrieved from http://hdl.handle.net/10722/197128

Note: this citation may be lacking information needed for this citation format:
Author name may be incomplete
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

庆开雄. “Thoracic endovascular stent graft repair (TEVAR) for treating type B aortic dissections (TBAD) : a hemodynamic and morphologic perspective.” 2013. Thesis, University of Hong Kong. Accessed March 01, 2021. http://hdl.handle.net/10722/197128.

Note: this citation may be lacking information needed for this citation format:
Author name may be incomplete
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

庆开雄. “Thoracic endovascular stent graft repair (TEVAR) for treating type B aortic dissections (TBAD) : a hemodynamic and morphologic perspective.” 2013. Web. 01 Mar 2021.

Note: this citation may be lacking information needed for this citation format:
Author name may be incomplete

Vancouver:

庆开雄. Thoracic endovascular stent graft repair (TEVAR) for treating type B aortic dissections (TBAD) : a hemodynamic and morphologic perspective. [Internet] [Thesis]. University of Hong Kong; 2013. [cited 2021 Mar 01]. Available from: http://hdl.handle.net/10722/197128.

Note: this citation may be lacking information needed for this citation format:
Author name may be incomplete
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

庆开雄. Thoracic endovascular stent graft repair (TEVAR) for treating type B aortic dissections (TBAD) : a hemodynamic and morphologic perspective. [Thesis]. University of Hong Kong; 2013. Available from: http://hdl.handle.net/10722/197128

Note: this citation may be lacking information needed for this citation format:
Author name may be incomplete
Not specified: Masters Thesis or Doctoral Dissertation

11. Kiemeneij, Ferdinand. Towards optimalization of clinical outcome after Palmaz Schatz coronary stent implantation.

Degree: 1995, Erasmus University Medical Center

Subjects/Keywords: cardiology; coronary diseases; heart surgery; stents

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Kiemeneij, F. (1995). Towards optimalization of clinical outcome after Palmaz Schatz coronary stent implantation. (Doctoral Dissertation). Erasmus University Medical Center. Retrieved from http://hdl.handle.net/1765/21765

Chicago Manual of Style (16th Edition):

Kiemeneij, Ferdinand. “Towards optimalization of clinical outcome after Palmaz Schatz coronary stent implantation.” 1995. Doctoral Dissertation, Erasmus University Medical Center. Accessed March 01, 2021. http://hdl.handle.net/1765/21765.

MLA Handbook (7th Edition):

Kiemeneij, Ferdinand. “Towards optimalization of clinical outcome after Palmaz Schatz coronary stent implantation.” 1995. Web. 01 Mar 2021.

Vancouver:

Kiemeneij F. Towards optimalization of clinical outcome after Palmaz Schatz coronary stent implantation. [Internet] [Doctoral dissertation]. Erasmus University Medical Center; 1995. [cited 2021 Mar 01]. Available from: http://hdl.handle.net/1765/21765.

Council of Science Editors:

Kiemeneij F. Towards optimalization of clinical outcome after Palmaz Schatz coronary stent implantation. [Doctoral Dissertation]. Erasmus University Medical Center; 1995. Available from: http://hdl.handle.net/1765/21765


Universitat de Barcelona

12. Yugueros Castellnou, Xavier. Estudio experimental in vitro de la técnica del stent paralelo en la reparación endovascular de los aneurismas de la aorta abdominal.

Degree: 2019, Universitat de Barcelona

 Parallel stenting is a surgical procedure used in endovascular repair of complex abdominal aortic aneurysms. The objective of this study has been to evaluate, using… (more)

Subjects/Keywords: Fisiologia patològica; Fisiología patológica; Pathological physiology; Aneurismes aòrtics; Aneurismas aórticos; Aortic aneurysms; Pròtesis de Stent; Stents; Stents (Surgery); Ciències de la Salut; 616.1

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Yugueros Castellnou, X. (2019). Estudio experimental in vitro de la técnica del stent paralelo en la reparación endovascular de los aneurismas de la aorta abdominal. (Thesis). Universitat de Barcelona. Retrieved from http://hdl.handle.net/10803/669918

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Yugueros Castellnou, Xavier. “Estudio experimental in vitro de la técnica del stent paralelo en la reparación endovascular de los aneurismas de la aorta abdominal.” 2019. Thesis, Universitat de Barcelona. Accessed March 01, 2021. http://hdl.handle.net/10803/669918.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Yugueros Castellnou, Xavier. “Estudio experimental in vitro de la técnica del stent paralelo en la reparación endovascular de los aneurismas de la aorta abdominal.” 2019. Web. 01 Mar 2021.

Vancouver:

Yugueros Castellnou X. Estudio experimental in vitro de la técnica del stent paralelo en la reparación endovascular de los aneurismas de la aorta abdominal. [Internet] [Thesis]. Universitat de Barcelona; 2019. [cited 2021 Mar 01]. Available from: http://hdl.handle.net/10803/669918.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Yugueros Castellnou X. Estudio experimental in vitro de la técnica del stent paralelo en la reparación endovascular de los aneurismas de la aorta abdominal. [Thesis]. Universitat de Barcelona; 2019. Available from: http://hdl.handle.net/10803/669918

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of North Texas

13. Yang, Hua. Study of Mechanical Performance of Stent Implants Using Theoretical and Numerical Approach.

Degree: 2015, University of North Texas

 The coronary heart disease kills more than 350,000 persons/year and it costs $108.9 billion for the United States each year, in spite of significant advancements… (more)

Subjects/Keywords: Stent implants; rhombus structure; cardiovascular disease; non-Newtonian flow; Stents (Surgery)  – Mechanical properties.; Biomedical materials  – Mechanical properties.; Cardiovascular system  – Surgery.; Heart  – Surgery.

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Yang, H. (2015). Study of Mechanical Performance of Stent Implants Using Theoretical and Numerical Approach. (Thesis). University of North Texas. Retrieved from https://digital.library.unt.edu/ark:/67531/metadc804879/

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Yang, Hua. “Study of Mechanical Performance of Stent Implants Using Theoretical and Numerical Approach.” 2015. Thesis, University of North Texas. Accessed March 01, 2021. https://digital.library.unt.edu/ark:/67531/metadc804879/.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Yang, Hua. “Study of Mechanical Performance of Stent Implants Using Theoretical and Numerical Approach.” 2015. Web. 01 Mar 2021.

Vancouver:

Yang H. Study of Mechanical Performance of Stent Implants Using Theoretical and Numerical Approach. [Internet] [Thesis]. University of North Texas; 2015. [cited 2021 Mar 01]. Available from: https://digital.library.unt.edu/ark:/67531/metadc804879/.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Yang H. Study of Mechanical Performance of Stent Implants Using Theoretical and Numerical Approach. [Thesis]. University of North Texas; 2015. Available from: https://digital.library.unt.edu/ark:/67531/metadc804879/

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

14. Shin, Minchul. MRI evaluation of a stented abdominal aorta of a rabbit.

Degree: MS, 2007, University of Alabama – Birmingham

Magnetic resonance imaging (MRI) is an attractive non-invasive angiographic device, not requiring nephrotoxic contrast agents and damaging exposure to radiation such as traditional angiography and… (more)

Subjects/Keywords: Blood-vessels  – Stenosis  – Measurement <; br>; Magnetic resonance imaging <; br>; Stents (Surgery) <; br>; Rabbits  – Cardiovascular system

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Shin, M. (2007). MRI evaluation of a stented abdominal aorta of a rabbit. (Masters Thesis). University of Alabama – Birmingham. Retrieved from http://contentdm.mhsl.uab.edu/u?/etd,537

Chicago Manual of Style (16th Edition):

Shin, Minchul. “MRI evaluation of a stented abdominal aorta of a rabbit.” 2007. Masters Thesis, University of Alabama – Birmingham. Accessed March 01, 2021. http://contentdm.mhsl.uab.edu/u?/etd,537.

MLA Handbook (7th Edition):

Shin, Minchul. “MRI evaluation of a stented abdominal aorta of a rabbit.” 2007. Web. 01 Mar 2021.

Vancouver:

Shin M. MRI evaluation of a stented abdominal aorta of a rabbit. [Internet] [Masters thesis]. University of Alabama – Birmingham; 2007. [cited 2021 Mar 01]. Available from: http://contentdm.mhsl.uab.edu/u?/etd,537.

Council of Science Editors:

Shin M. MRI evaluation of a stented abdominal aorta of a rabbit. [Masters Thesis]. University of Alabama – Birmingham; 2007. Available from: http://contentdm.mhsl.uab.edu/u?/etd,537


University of Hong Kong

15. 林省京. Computational fluid dynamic analyses of the endovascular stent-graft at the thoracic aorta with different biomechanical factors.

Degree: 2008, University of Hong Kong

Subjects/Keywords: Hemodynamics.; Thoracic arteries.; Stents (Surgery) - Fluid dynamics.

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

林省京.. (2008). Computational fluid dynamic analyses of the endovascular stent-graft at the thoracic aorta with different biomechanical factors. (Thesis). University of Hong Kong. Retrieved from http://hdl.handle.net/10722/54652

Note: this citation may be lacking information needed for this citation format:
Author name may be incomplete
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

林省京.. “Computational fluid dynamic analyses of the endovascular stent-graft at the thoracic aorta with different biomechanical factors.” 2008. Thesis, University of Hong Kong. Accessed March 01, 2021. http://hdl.handle.net/10722/54652.

Note: this citation may be lacking information needed for this citation format:
Author name may be incomplete
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

林省京.. “Computational fluid dynamic analyses of the endovascular stent-graft at the thoracic aorta with different biomechanical factors.” 2008. Web. 01 Mar 2021.

Note: this citation may be lacking information needed for this citation format:
Author name may be incomplete

Vancouver:

林省京.. Computational fluid dynamic analyses of the endovascular stent-graft at the thoracic aorta with different biomechanical factors. [Internet] [Thesis]. University of Hong Kong; 2008. [cited 2021 Mar 01]. Available from: http://hdl.handle.net/10722/54652.

Note: this citation may be lacking information needed for this citation format:
Author name may be incomplete
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

林省京.. Computational fluid dynamic analyses of the endovascular stent-graft at the thoracic aorta with different biomechanical factors. [Thesis]. University of Hong Kong; 2008. Available from: http://hdl.handle.net/10722/54652

Note: this citation may be lacking information needed for this citation format:
Author name may be incomplete
Not specified: Masters Thesis or Doctoral Dissertation


University of Missouri – Kansas City

16. Grodzinsky, Anna. Bleeding Risk Following Percutaneous Intervention in Patients with Diabetes Prescribed Dual Anti Platelet Therapy.

Degree: 2015, University of Missouri – Kansas City

 Patients with diabetes (DM) experience higher rates of in-stent restenosis and therefore greater benefit from drug eluting stent (DES) implant at the time of percutaneous… (more)

Subjects/Keywords: Hemorrhage; Stents (Surgery); Diabetes  – Complications; Percutaneous Coronary Intervention; Hemorrhage; Diabetes Complications; Thesis  – University of Missouri – Kansas City  – Medicine

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Grodzinsky, A. (2015). Bleeding Risk Following Percutaneous Intervention in Patients with Diabetes Prescribed Dual Anti Platelet Therapy. (Thesis). University of Missouri – Kansas City. Retrieved from http://hdl.handle.net/10355/46326

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Grodzinsky, Anna. “Bleeding Risk Following Percutaneous Intervention in Patients with Diabetes Prescribed Dual Anti Platelet Therapy.” 2015. Thesis, University of Missouri – Kansas City. Accessed March 01, 2021. http://hdl.handle.net/10355/46326.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Grodzinsky, Anna. “Bleeding Risk Following Percutaneous Intervention in Patients with Diabetes Prescribed Dual Anti Platelet Therapy.” 2015. Web. 01 Mar 2021.

Vancouver:

Grodzinsky A. Bleeding Risk Following Percutaneous Intervention in Patients with Diabetes Prescribed Dual Anti Platelet Therapy. [Internet] [Thesis]. University of Missouri – Kansas City; 2015. [cited 2021 Mar 01]. Available from: http://hdl.handle.net/10355/46326.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Grodzinsky A. Bleeding Risk Following Percutaneous Intervention in Patients with Diabetes Prescribed Dual Anti Platelet Therapy. [Thesis]. University of Missouri – Kansas City; 2015. Available from: http://hdl.handle.net/10355/46326

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of North Texas

17. Alagarsamy, Karthik. Application of High Entropy Alloys in Stent Implants.

Degree: 2017, University of North Texas

 High entropy alloys (HEAs) are alloys with five or more principal elements. Due to these distinct concept of alloying, the HEA exhibits unique and superior… (more)

Subjects/Keywords: High entropy alloys; stent implants; fatigue life; computational modeling; Engineering, Mechanical; Engineering, Materials Science; Engineering, Biomedical; Alloys.; Stents (Surgery); Biomedical materials.

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Alagarsamy, K. (2017). Application of High Entropy Alloys in Stent Implants. (Thesis). University of North Texas. Retrieved from https://digital.library.unt.edu/ark:/67531/metadc984159/

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Alagarsamy, Karthik. “Application of High Entropy Alloys in Stent Implants.” 2017. Thesis, University of North Texas. Accessed March 01, 2021. https://digital.library.unt.edu/ark:/67531/metadc984159/.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Alagarsamy, Karthik. “Application of High Entropy Alloys in Stent Implants.” 2017. Web. 01 Mar 2021.

Vancouver:

Alagarsamy K. Application of High Entropy Alloys in Stent Implants. [Internet] [Thesis]. University of North Texas; 2017. [cited 2021 Mar 01]. Available from: https://digital.library.unt.edu/ark:/67531/metadc984159/.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Alagarsamy K. Application of High Entropy Alloys in Stent Implants. [Thesis]. University of North Texas; 2017. Available from: https://digital.library.unt.edu/ark:/67531/metadc984159/

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Macquarie University

18. Zhang, Mingzi. Haemodynamic simulation and optimisation for the flow-diversion treatment of intracranial aneurysms.

Degree: 2018, Macquarie University

Empirical thesis.

Thesis carried out as part of a co-tutelle arrangement with Tohoku University.

Bibliography: pages 125-136.

Chapter 1. Introduction  – Chapter 2. Materials and… (more)

Subjects/Keywords: Stents (Surgery)  – Fluid dynamics; Intracranial aneurysms  – Treatment; computational fluid dynamics (CFD); haemodynamics; flow-diversion treatment; intracranial aneurysms; design optimisation; treatment planning

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Zhang, M. (2018). Haemodynamic simulation and optimisation for the flow-diversion treatment of intracranial aneurysms. (Doctoral Dissertation). Macquarie University. Retrieved from http://hdl.handle.net/1959.14/1274879

Chicago Manual of Style (16th Edition):

Zhang, Mingzi. “Haemodynamic simulation and optimisation for the flow-diversion treatment of intracranial aneurysms.” 2018. Doctoral Dissertation, Macquarie University. Accessed March 01, 2021. http://hdl.handle.net/1959.14/1274879.

MLA Handbook (7th Edition):

Zhang, Mingzi. “Haemodynamic simulation and optimisation for the flow-diversion treatment of intracranial aneurysms.” 2018. Web. 01 Mar 2021.

Vancouver:

Zhang M. Haemodynamic simulation and optimisation for the flow-diversion treatment of intracranial aneurysms. [Internet] [Doctoral dissertation]. Macquarie University; 2018. [cited 2021 Mar 01]. Available from: http://hdl.handle.net/1959.14/1274879.

Council of Science Editors:

Zhang M. Haemodynamic simulation and optimisation for the flow-diversion treatment of intracranial aneurysms. [Doctoral Dissertation]. Macquarie University; 2018. Available from: http://hdl.handle.net/1959.14/1274879


University of New South Wales

19. Huang, Henry Yen-Chin. Theoretical and experimental modelling of stress within the neck of endoluminal grafted artery.

Degree: Graduate School of Biomedical Engineering, 2006, University of New South Wales

 The success of endoluminal stent-graft treatment for abdominal aortic aneurysm relies on maintenance of an effective seal when the stent expands into the healthy artery.… (more)

Subjects/Keywords: Arterial grafts; Aortic aneurysms; Stents (Surgery); Stress (Physiology)

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Huang, H. Y. (2006). Theoretical and experimental modelling of stress within the neck of endoluminal grafted artery. (Doctoral Dissertation). University of New South Wales. Retrieved from http://handle.unsw.edu.au/1959.4/29146 ; https://unsworks.unsw.edu.au/fapi/datastream/unsworks:1377/SOURCE02?view=true

Chicago Manual of Style (16th Edition):

Huang, Henry Yen-Chin. “Theoretical and experimental modelling of stress within the neck of endoluminal grafted artery.” 2006. Doctoral Dissertation, University of New South Wales. Accessed March 01, 2021. http://handle.unsw.edu.au/1959.4/29146 ; https://unsworks.unsw.edu.au/fapi/datastream/unsworks:1377/SOURCE02?view=true.

MLA Handbook (7th Edition):

Huang, Henry Yen-Chin. “Theoretical and experimental modelling of stress within the neck of endoluminal grafted artery.” 2006. Web. 01 Mar 2021.

Vancouver:

Huang HY. Theoretical and experimental modelling of stress within the neck of endoluminal grafted artery. [Internet] [Doctoral dissertation]. University of New South Wales; 2006. [cited 2021 Mar 01]. Available from: http://handle.unsw.edu.au/1959.4/29146 ; https://unsworks.unsw.edu.au/fapi/datastream/unsworks:1377/SOURCE02?view=true.

Council of Science Editors:

Huang HY. Theoretical and experimental modelling of stress within the neck of endoluminal grafted artery. [Doctoral Dissertation]. University of New South Wales; 2006. Available from: http://handle.unsw.edu.au/1959.4/29146 ; https://unsworks.unsw.edu.au/fapi/datastream/unsworks:1377/SOURCE02?view=true


Stellenbosch University

20. Esterhuyse, Anton. Structural design of a stent for a percutaneous aortic heart valve.

Degree: Mechanical and Mechatronic Engineering, 2009, Stellenbosch University

Thesis (MScEng (Mechanical and Mechatronic Engineering)) – University of Stellenbosch, 2009.

Elderly patients suffering from aortic valvular dysfunction are often denied aortic valve replacement due to… (more)

Subjects/Keywords: Mechanical engineering; Heart  – Surgery; Stents (Surgery); Aortic valve; Mechanical and Mechatronic Engineering

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Esterhuyse, A. (2009). Structural design of a stent for a percutaneous aortic heart valve. (Thesis). Stellenbosch University. Retrieved from http://hdl.handle.net/10019.1/2706

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Esterhuyse, Anton. “Structural design of a stent for a percutaneous aortic heart valve.” 2009. Thesis, Stellenbosch University. Accessed March 01, 2021. http://hdl.handle.net/10019.1/2706.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Esterhuyse, Anton. “Structural design of a stent for a percutaneous aortic heart valve.” 2009. Web. 01 Mar 2021.

Vancouver:

Esterhuyse A. Structural design of a stent for a percutaneous aortic heart valve. [Internet] [Thesis]. Stellenbosch University; 2009. [cited 2021 Mar 01]. Available from: http://hdl.handle.net/10019.1/2706.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Esterhuyse A. Structural design of a stent for a percutaneous aortic heart valve. [Thesis]. Stellenbosch University; 2009. Available from: http://hdl.handle.net/10019.1/2706

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Columbia University

21. Russ, Jonathan Brent. Computational Design of Structures for Enhanced Failure Resistance.

Degree: 2021, Columbia University

 The field of structural design optimization is one with great breadth and depth in many engineering applications. From the perspective of a designer, three distinct… (more)

Subjects/Keywords: Biomedical engineering; Computer-aided design; Congenital heart disease; Heart valve prosthesis – Research; Stents (Surgery); Congenital heart disease in children – Surgery; Failure analysis (Engineering)

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Russ, J. B. (2021). Computational Design of Structures for Enhanced Failure Resistance. (Doctoral Dissertation). Columbia University. Retrieved from https://doi.org/10.7916/d8-rfmz-6x23

Chicago Manual of Style (16th Edition):

Russ, Jonathan Brent. “Computational Design of Structures for Enhanced Failure Resistance.” 2021. Doctoral Dissertation, Columbia University. Accessed March 01, 2021. https://doi.org/10.7916/d8-rfmz-6x23.

MLA Handbook (7th Edition):

Russ, Jonathan Brent. “Computational Design of Structures for Enhanced Failure Resistance.” 2021. Web. 01 Mar 2021.

Vancouver:

Russ JB. Computational Design of Structures for Enhanced Failure Resistance. [Internet] [Doctoral dissertation]. Columbia University; 2021. [cited 2021 Mar 01]. Available from: https://doi.org/10.7916/d8-rfmz-6x23.

Council of Science Editors:

Russ JB. Computational Design of Structures for Enhanced Failure Resistance. [Doctoral Dissertation]. Columbia University; 2021. Available from: https://doi.org/10.7916/d8-rfmz-6x23

22. Dimble, Dipesh S. Geometry modeling for patterned and repetitive configurations.

Degree: MS, 2006, University of Alabama – Birmingham

Over the years, the use of computational engineering applications such as computer-aided design (CAD), computational fluid dynamics (CFD), and computational structural mechanics (CSM) has grown… (more)

Subjects/Keywords: Computer graphics  – Computer programs <; br>; Geometry  – Computer programs <; br>; Numerical grid generation (Numerical analysis)  – Computer programs <; br>; Stents (Surgery)  – Computer-aided design

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Dimble, D. S. (2006). Geometry modeling for patterned and repetitive configurations. (Masters Thesis). University of Alabama – Birmingham. Retrieved from http://contentdm.mhsl.uab.edu/u?/etd,28

Chicago Manual of Style (16th Edition):

Dimble, Dipesh S. “Geometry modeling for patterned and repetitive configurations.” 2006. Masters Thesis, University of Alabama – Birmingham. Accessed March 01, 2021. http://contentdm.mhsl.uab.edu/u?/etd,28.

MLA Handbook (7th Edition):

Dimble, Dipesh S. “Geometry modeling for patterned and repetitive configurations.” 2006. Web. 01 Mar 2021.

Vancouver:

Dimble DS. Geometry modeling for patterned and repetitive configurations. [Internet] [Masters thesis]. University of Alabama – Birmingham; 2006. [cited 2021 Mar 01]. Available from: http://contentdm.mhsl.uab.edu/u?/etd,28.

Council of Science Editors:

Dimble DS. Geometry modeling for patterned and repetitive configurations. [Masters Thesis]. University of Alabama – Birmingham; 2006. Available from: http://contentdm.mhsl.uab.edu/u?/etd,28

23. Halwani, Dina. Metal-tissue interactions in early stage biocorrosion of metallic stents.

Degree: MS, 2007, University of Alabama – Birmingham

In-vivo corrosion of endovascular stents presents two main risks; release of toxic metallic ions and deterioration of the mechanical properties of the stents which may… (more)

Subjects/Keywords: Stents (Surgery)  – Materials  – Biodegradation <; br>; Steel, Stainless  – Biodegradation <; br>; Nickel-titanium alloys  – Biodegradation <; br>; Scanning electron microscopy <; br>; X-ray spectroscopy

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Halwani, D. (2007). Metal-tissue interactions in early stage biocorrosion of metallic stents. (Masters Thesis). University of Alabama – Birmingham. Retrieved from http://contentdm.mhsl.uab.edu/u?/etd,106

Chicago Manual of Style (16th Edition):

Halwani, Dina. “Metal-tissue interactions in early stage biocorrosion of metallic stents.” 2007. Masters Thesis, University of Alabama – Birmingham. Accessed March 01, 2021. http://contentdm.mhsl.uab.edu/u?/etd,106.

MLA Handbook (7th Edition):

Halwani, Dina. “Metal-tissue interactions in early stage biocorrosion of metallic stents.” 2007. Web. 01 Mar 2021.

Vancouver:

Halwani D. Metal-tissue interactions in early stage biocorrosion of metallic stents. [Internet] [Masters thesis]. University of Alabama – Birmingham; 2007. [cited 2021 Mar 01]. Available from: http://contentdm.mhsl.uab.edu/u?/etd,106.

Council of Science Editors:

Halwani D. Metal-tissue interactions in early stage biocorrosion of metallic stents. [Masters Thesis]. University of Alabama – Birmingham; 2007. Available from: http://contentdm.mhsl.uab.edu/u?/etd,106

24. Arauz Garofalo, Gianluca. Prospects of microwave spectrometry for vascular stent monitoring. Towards a non-invasive and non-ionizing follow-up alternative.

Degree: Departament de Física de la Matèria Condensada, 2017, Universitat de Barcelona

 Throughout this thesis we have assessed the prospects of microwave spectrometry (MWS) as a non-ionizing non-invasive monitoring alternative for stented patients in a very early… (more)

Subjects/Keywords: Espectrometria de masses; Espectrometría de masas; Mass spectrometry; Microones; Microondas; Microwaves; Pròtesis de Stent; Stents (Surgery); Stent; Aterosclerosi; Aterosclerosis; Atherosclerosis; Ciències Experimentals i Matemàtiques; 538.9

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Arauz Garofalo, G. (2017). Prospects of microwave spectrometry for vascular stent monitoring. Towards a non-invasive and non-ionizing follow-up alternative. (Thesis). Universitat de Barcelona. Retrieved from http://hdl.handle.net/10803/404376

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Arauz Garofalo, Gianluca. “Prospects of microwave spectrometry for vascular stent monitoring. Towards a non-invasive and non-ionizing follow-up alternative.” 2017. Thesis, Universitat de Barcelona. Accessed March 01, 2021. http://hdl.handle.net/10803/404376.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Arauz Garofalo, Gianluca. “Prospects of microwave spectrometry for vascular stent monitoring. Towards a non-invasive and non-ionizing follow-up alternative.” 2017. Web. 01 Mar 2021.

Vancouver:

Arauz Garofalo G. Prospects of microwave spectrometry for vascular stent monitoring. Towards a non-invasive and non-ionizing follow-up alternative. [Internet] [Thesis]. Universitat de Barcelona; 2017. [cited 2021 Mar 01]. Available from: http://hdl.handle.net/10803/404376.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Arauz Garofalo G. Prospects of microwave spectrometry for vascular stent monitoring. Towards a non-invasive and non-ionizing follow-up alternative. [Thesis]. Universitat de Barcelona; 2017. Available from: http://hdl.handle.net/10803/404376

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

25. Nelson, Terrilyn. Health-related Quality of Life One Year After Coronary Angioplasty and/or Coronary Stenting.

Degree: MS, Graduate Nursing, 1998, South Dakota State University

  Cardiovascular diseases (CVD) afflict approximately 60 million Americans and are the leading causes of death in the United States. In 1995, more than 950,000… (more)

Subjects/Keywords: angioplasty; stents; coronary heart disease surgery patients; quality of life; Nursing

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Nelson, T. (1998). Health-related Quality of Life One Year After Coronary Angioplasty and/or Coronary Stenting. (Masters Thesis). South Dakota State University. Retrieved from https://openprairie.sdstate.edu/etd/872

Chicago Manual of Style (16th Edition):

Nelson, Terrilyn. “Health-related Quality of Life One Year After Coronary Angioplasty and/or Coronary Stenting.” 1998. Masters Thesis, South Dakota State University. Accessed March 01, 2021. https://openprairie.sdstate.edu/etd/872.

MLA Handbook (7th Edition):

Nelson, Terrilyn. “Health-related Quality of Life One Year After Coronary Angioplasty and/or Coronary Stenting.” 1998. Web. 01 Mar 2021.

Vancouver:

Nelson T. Health-related Quality of Life One Year After Coronary Angioplasty and/or Coronary Stenting. [Internet] [Masters thesis]. South Dakota State University; 1998. [cited 2021 Mar 01]. Available from: https://openprairie.sdstate.edu/etd/872.

Council of Science Editors:

Nelson T. Health-related Quality of Life One Year After Coronary Angioplasty and/or Coronary Stenting. [Masters Thesis]. South Dakota State University; 1998. Available from: https://openprairie.sdstate.edu/etd/872

26. Martinez, Adam W. Design and development of an elastin mimetic stent with therapeutic delivery potential.

Degree: PhD, Biomedical Engineering, 2011, Georgia Tech

 Stenting remains a common treatment option for atherosclerotic arteries. The main drawback of early stent platforms was restenosis, which has been combated by drug eluting… (more)

Subjects/Keywords: Rat stenting; Elastin miemtic; Laser fabrication; Crosslinking; Drug delivery; Stent; Stents (Surgery); Drug-eluting stents; Drug delivery devices; Implants, Artificial

…fluoroscopy with commercial stents above and below (C) EWlastin mimetic stent doped with… …which has been combated by drug eluting stents (DESs). The current limitation facing… …development of the next generation of DESs and first generation bioabsorbable stents to combat… …development of a new class of bioabsorbable stents composed of elastin mimetic protein polymers. The… …initial work focused on the ability to process these protein polymers into stents and ensure… 

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Martinez, A. W. (2011). Design and development of an elastin mimetic stent with therapeutic delivery potential. (Doctoral Dissertation). Georgia Tech. Retrieved from http://hdl.handle.net/1853/45926

Chicago Manual of Style (16th Edition):

Martinez, Adam W. “Design and development of an elastin mimetic stent with therapeutic delivery potential.” 2011. Doctoral Dissertation, Georgia Tech. Accessed March 01, 2021. http://hdl.handle.net/1853/45926.

MLA Handbook (7th Edition):

Martinez, Adam W. “Design and development of an elastin mimetic stent with therapeutic delivery potential.” 2011. Web. 01 Mar 2021.

Vancouver:

Martinez AW. Design and development of an elastin mimetic stent with therapeutic delivery potential. [Internet] [Doctoral dissertation]. Georgia Tech; 2011. [cited 2021 Mar 01]. Available from: http://hdl.handle.net/1853/45926.

Council of Science Editors:

Martinez AW. Design and development of an elastin mimetic stent with therapeutic delivery potential. [Doctoral Dissertation]. Georgia Tech; 2011. Available from: http://hdl.handle.net/1853/45926


University of Hong Kong

27. Wang, Yan. Atherosclerotic disease of the carotid, coronary and renal arteries: diagnosis, angioplasty and the effect ofstent surface on early thrombosis and restenosis.

Degree: 2004, University of Hong Kong

Subjects/Keywords: Stents (Surgery); Arteries - Stenosis.; Carotid artery - Diseases - Diagnosis.; Coronary heart disease - Diagnosis.; Renal artery - Diseases - Diagnosis.; Angioplasty.

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Wang, Y. (2004). Atherosclerotic disease of the carotid, coronary and renal arteries: diagnosis, angioplasty and the effect ofstent surface on early thrombosis and restenosis. (Thesis). University of Hong Kong. Retrieved from http://hdl.handle.net/10722/56596

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Wang, Yan. “Atherosclerotic disease of the carotid, coronary and renal arteries: diagnosis, angioplasty and the effect ofstent surface on early thrombosis and restenosis.” 2004. Thesis, University of Hong Kong. Accessed March 01, 2021. http://hdl.handle.net/10722/56596.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Wang, Yan. “Atherosclerotic disease of the carotid, coronary and renal arteries: diagnosis, angioplasty and the effect ofstent surface on early thrombosis and restenosis.” 2004. Web. 01 Mar 2021.

Vancouver:

Wang Y. Atherosclerotic disease of the carotid, coronary and renal arteries: diagnosis, angioplasty and the effect ofstent surface on early thrombosis and restenosis. [Internet] [Thesis]. University of Hong Kong; 2004. [cited 2021 Mar 01]. Available from: http://hdl.handle.net/10722/56596.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Wang Y. Atherosclerotic disease of the carotid, coronary and renal arteries: diagnosis, angioplasty and the effect ofstent surface on early thrombosis and restenosis. [Thesis]. University of Hong Kong; 2004. Available from: http://hdl.handle.net/10722/56596

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

28. Matsoukis, Ioannis. Συγκριτική μελέτη της κλινικής αποτελεσματικότητας επικαλυμμένων και μη επικαλυμμένων ενδοστεφανιαίων προθέσεων.

Degree: 2020, National and Kapodistrian University of Athens; Εθνικό και Καποδιστριακό Πανεπιστήμιο Αθηνών (ΕΚΠΑ)

 In this Thesis, long-term outcomes of 600 patients with chronic stable angina and an isolated de-novo lesion in the pLAD that underwent PCI with Endeavor-zotarolimus… (more)

Subjects/Keywords: Ενδοστεφανιαίες προθέσεις κεκαλυμμένες με φαρμακευτικές ουσίες; Στεφανιαίες ενδοπροθέσεις; Επεμβάσεις αορτοστεφανιαίας παράκαμψης; Κλινική αποτελεσματικότητα; Αγγειοπλαστική στεφανιαίων αγγείων; Στεφανιαία νόσος; Coronary artery bypass graft surgery; Coronary artery disease; Percutaneous coronary intervention; Coronary stent; Drug eluting stents (DES); Clinical effectiveness

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Matsoukis, I. (2020). Συγκριτική μελέτη της κλινικής αποτελεσματικότητας επικαλυμμένων και μη επικαλυμμένων ενδοστεφανιαίων προθέσεων. (Thesis). National and Kapodistrian University of Athens; Εθνικό και Καποδιστριακό Πανεπιστήμιο Αθηνών (ΕΚΠΑ). Retrieved from http://hdl.handle.net/10442/hedi/48085

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Matsoukis, Ioannis. “Συγκριτική μελέτη της κλινικής αποτελεσματικότητας επικαλυμμένων και μη επικαλυμμένων ενδοστεφανιαίων προθέσεων.” 2020. Thesis, National and Kapodistrian University of Athens; Εθνικό και Καποδιστριακό Πανεπιστήμιο Αθηνών (ΕΚΠΑ). Accessed March 01, 2021. http://hdl.handle.net/10442/hedi/48085.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Matsoukis, Ioannis. “Συγκριτική μελέτη της κλινικής αποτελεσματικότητας επικαλυμμένων και μη επικαλυμμένων ενδοστεφανιαίων προθέσεων.” 2020. Web. 01 Mar 2021.

Vancouver:

Matsoukis I. Συγκριτική μελέτη της κλινικής αποτελεσματικότητας επικαλυμμένων και μη επικαλυμμένων ενδοστεφανιαίων προθέσεων. [Internet] [Thesis]. National and Kapodistrian University of Athens; Εθνικό και Καποδιστριακό Πανεπιστήμιο Αθηνών (ΕΚΠΑ); 2020. [cited 2021 Mar 01]. Available from: http://hdl.handle.net/10442/hedi/48085.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Matsoukis I. Συγκριτική μελέτη της κλινικής αποτελεσματικότητας επικαλυμμένων και μη επικαλυμμένων ενδοστεφανιαίων προθέσεων. [Thesis]. National and Kapodistrian University of Athens; Εθνικό και Καποδιστριακό Πανεπιστήμιο Αθηνών (ΕΚΠΑ); 2020. Available from: http://hdl.handle.net/10442/hedi/48085

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Georgia Tech

29. Rose, Stacey Loren. In Vitro Model of Vascular Healing in the Presence of Biomaterials.

Degree: PhD, Biomedical Engineering, 2006, Georgia Tech

 Coronary artery stent placement has been a significant advance in the percutaneous treatment of atherosclerotic disease, and tissue engineered vascular grafts may provide a viable… (more)

Subjects/Keywords: Biomaterials; Leukocytes; Smooth muscle cells; Endothelial cells; Stents (Surgery); Vascular endothelial growth factors; Biocompatibility; Leucocytes; Regeneration (Biology)

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Rose, S. L. (2006). In Vitro Model of Vascular Healing in the Presence of Biomaterials. (Doctoral Dissertation). Georgia Tech. Retrieved from http://hdl.handle.net/1853/13955

Chicago Manual of Style (16th Edition):

Rose, Stacey Loren. “In Vitro Model of Vascular Healing in the Presence of Biomaterials.” 2006. Doctoral Dissertation, Georgia Tech. Accessed March 01, 2021. http://hdl.handle.net/1853/13955.

MLA Handbook (7th Edition):

Rose, Stacey Loren. “In Vitro Model of Vascular Healing in the Presence of Biomaterials.” 2006. Web. 01 Mar 2021.

Vancouver:

Rose SL. In Vitro Model of Vascular Healing in the Presence of Biomaterials. [Internet] [Doctoral dissertation]. Georgia Tech; 2006. [cited 2021 Mar 01]. Available from: http://hdl.handle.net/1853/13955.

Council of Science Editors:

Rose SL. In Vitro Model of Vascular Healing in the Presence of Biomaterials. [Doctoral Dissertation]. Georgia Tech; 2006. Available from: http://hdl.handle.net/1853/13955

30. Andukuri, Adinarayana. A Bioinspired Multifunctional Nanomatrix For Cardiovascular Applications.

Degree: 2013, University of Alabama – Birmingham

Bioinspired solutions for challenges faced by conventional therapies are rapidly emerging, especially as new and innovative improvements in medical devices are constantly being researched and… (more)

Subjects/Keywords: Stents (Surgery) – Biocompatibility.<; br>; Coatings – Biocompatibility.<; br>; Endothelium.<; br>; Peptide amphiphiles – Formation.<; br>; Vascular endothelium – Regeneration – Equipment and supplies – Design and construction.<; br>; Nanostructured materials.<; br>; Biomedical materials.

…Nanomatrix Coatings for Stents ................14 EFFECT OF ENDOTHELIUM MIMICKING SELF-ASSEMBLED… …130 x 1 INTRODUCTION Stents are the most commonly implanted devices used in the… …inflated. Bare metal stents (BMS) deployment has reduced the rate of re-narrowing… …restenosis caused by inevitable endothelial injury1. Drug-eluting stents (DES) have… …stents have been developed which may also reduce late stent thrombosis6-11. Another new… 

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Andukuri, A. (2013). A Bioinspired Multifunctional Nanomatrix For Cardiovascular Applications. (Thesis). University of Alabama – Birmingham. Retrieved from http://contentdm.mhsl.uab.edu/u?/etd,1481

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Andukuri, Adinarayana. “A Bioinspired Multifunctional Nanomatrix For Cardiovascular Applications.” 2013. Thesis, University of Alabama – Birmingham. Accessed March 01, 2021. http://contentdm.mhsl.uab.edu/u?/etd,1481.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Andukuri, Adinarayana. “A Bioinspired Multifunctional Nanomatrix For Cardiovascular Applications.” 2013. Web. 01 Mar 2021.

Vancouver:

Andukuri A. A Bioinspired Multifunctional Nanomatrix For Cardiovascular Applications. [Internet] [Thesis]. University of Alabama – Birmingham; 2013. [cited 2021 Mar 01]. Available from: http://contentdm.mhsl.uab.edu/u?/etd,1481.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Andukuri A. A Bioinspired Multifunctional Nanomatrix For Cardiovascular Applications. [Thesis]. University of Alabama – Birmingham; 2013. Available from: http://contentdm.mhsl.uab.edu/u?/etd,1481

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

[1] [2]

.