Advanced search options

Advanced Search Options 🞨

Browse by author name (“Author name starts with…”).

Find ETDs with:

in
/  
in
/  
in
/  
in

Written in Published in Earliest date Latest date

Sorted by

Results per page:

You searched for subject:(Software CONTAM). One record found.

Search Limiters

Last 2 Years | English Only

No search limiters apply to these results.

▼ Search Limiters


Universidade de Lisboa

1. Fernandes, Cláudia Alexandra de Almeida. Avaliação da ventilação natural num lar de idosos.

Degree: 2016, Universidade de Lisboa

Tese de mestrado integrado em Engenharia da Energia e do Ambiente, apresentada à Universidade de Lisboa, através da Faculdade de Ciências, 2016

Esta dissertação tem como principal objetivo a criação de um modelo computacional baseado num lar de idosos existente. Este foi validado através das taxas de ventilação obtidas experimentalmente através do método de emissão constante, método de PFT’s e o método do decaimento. As simulações realizadas com o software CONTAM permitiram estudar as taxas de ventilação do caso de estudo, concluindo-se que o edifício não cumpria os requisitos mínimos para manter uma boa qualidade do ar interior. Através da Norma NP 1037-parte 1 (2015) calcularam-se caudais mínimos considerando o tipo de compartimento e, posteriormente, o número de ocupantes. Baseando-se nestes valores, criaram-se aberturas de admissão e exaustão do ar dos compartimentos, melhorando assim as taxas de ventilação no caso de estudo. Estudou-se a inversão de tiragem, verificando-se que este fenómeno acontecia aproximadamente 15% do ano típico considerado. Concluiu-se que como o edifício é térreo os efeitos eólicos eram praticamente nulos, mas que por outro lado os efeitos térmicos eram sentidos nos meses de verão. As renovações por hora dos quartos de dormir melhoraram quando se aplicou as condições base da Norma NP 1037 (2015), apesar disso estas não são suficientes para manter a qualidade do ar interior. Assim, conclui-se que a ventilação natural por si só não é um método viável, podendo ser complementada com um sistema de ventilação mecânica.

The present Masters’ Thesis has its main objective on the creation of computational model based on a nursing home’s measured data. The model was validated by using of ventilation rates experimentally obtained by various methods, like the constant emission, PFT’s and decay methods. Through simulations with the CONTAM software, the case study’s ventilation rates were studied, concluding that the building didn’t meet the minimal requirements to maintain a good interior air quality. Using the norm NP 1037 (2015) and considering the type of compartment and, posteriorly the number of occupants, the minimal flows were calculated. Based on these values, the compartment’s air admission and exhaustion openings were created, consequently improving the rooms’ ventilation rates. On another phase, the air flux inversion was studied, verifying that this phenomenon occurred approximately 15% of the typical year. Getting to the conclusion that like the building is ground floored the wind effects were practically null, but on the other hand the thermal effects were felt during the summer months. The sleeping rooms’ air changes per hour improved when the base conditions of the norm NP 1037 (2015) were applied, although these were not enough to maintain the interior air quality. Therefore, it is established that natural ventilation by itself isn’t a viable approach, with the possibility of being complemented with a mechanical ventilation system.

Advisors/Committee Members: Viegas, João Godinho, Silva, Fernando Marques da,1955-.

Subjects/Keywords: Software CONTAM; Qualidade do ar interior; Renovações por hora; Ventilação natural; Teses de mestrado - 2016; Domínio/Área Científica::Engenharia e Tecnologia::Engenharia do Ambiente

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Fernandes, C. A. d. A. (2016). Avaliação da ventilação natural num lar de idosos. (Thesis). Universidade de Lisboa. Retrieved from http://www.rcaap.pt/detail.jsp?id=oai:repositorio.ul.pt:10451/26558

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Fernandes, Cláudia Alexandra de Almeida. “Avaliação da ventilação natural num lar de idosos.” 2016. Thesis, Universidade de Lisboa. Accessed January 26, 2020. http://www.rcaap.pt/detail.jsp?id=oai:repositorio.ul.pt:10451/26558.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Fernandes, Cláudia Alexandra de Almeida. “Avaliação da ventilação natural num lar de idosos.” 2016. Web. 26 Jan 2020.

Vancouver:

Fernandes CAdA. Avaliação da ventilação natural num lar de idosos. [Internet] [Thesis]. Universidade de Lisboa; 2016. [cited 2020 Jan 26]. Available from: http://www.rcaap.pt/detail.jsp?id=oai:repositorio.ul.pt:10451/26558.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Fernandes CAdA. Avaliação da ventilação natural num lar de idosos. [Thesis]. Universidade de Lisboa; 2016. Available from: http://www.rcaap.pt/detail.jsp?id=oai:repositorio.ul.pt:10451/26558

Note: this citation may be lacking information needed for this citation format: