Advanced search options

Advanced Search Options 🞨

Browse by author name (“Author name starts with…”).

Find ETDs with:

in
/  
in
/  
in
/  
in

Written in Published in Earliest date Latest date

Sorted by

Results per page:

Sorted by: relevance · author · university · dateNew search

You searched for subject:(Screw pull out). Showing records 1 – 6 of 6 total matches.

Search Limiters

Last 2 Years | English Only

No search limiters apply to these results.

▼ Search Limiters


Brunel University

1. Piper, Antony T. Modelling cancellous bone screw performance using finite element models.

Degree: PhD, 2016, Brunel University

 Implants such as intramedullary nails or cancellous screws are used to mechanically stabilize fractures in bone. They provide reinforcement to the bone if they find… (more)

Subjects/Keywords: 617.4; Intramedullary implants; Screw pull-out; Cement augmentation; Bone cement

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Piper, A. T. (2016). Modelling cancellous bone screw performance using finite element models. (Doctoral Dissertation). Brunel University. Retrieved from http://bura.brunel.ac.uk/handle/2438/12071 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.681196

Chicago Manual of Style (16th Edition):

Piper, Antony T. “Modelling cancellous bone screw performance using finite element models.” 2016. Doctoral Dissertation, Brunel University. Accessed October 20, 2019. http://bura.brunel.ac.uk/handle/2438/12071 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.681196.

MLA Handbook (7th Edition):

Piper, Antony T. “Modelling cancellous bone screw performance using finite element models.” 2016. Web. 20 Oct 2019.

Vancouver:

Piper AT. Modelling cancellous bone screw performance using finite element models. [Internet] [Doctoral dissertation]. Brunel University; 2016. [cited 2019 Oct 20]. Available from: http://bura.brunel.ac.uk/handle/2438/12071 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.681196.

Council of Science Editors:

Piper AT. Modelling cancellous bone screw performance using finite element models. [Doctoral Dissertation]. Brunel University; 2016. Available from: http://bura.brunel.ac.uk/handle/2438/12071 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.681196


Mississippi State University

2. Demko, Jennifer Lynn. AXIAL PULL-OUT STRENGTH OF 3.5 CORTICAL AND 4.0 CANCELLOUS BONE SCREWS PLACED IN CANINE PROXIMAL TIBIAS USING MANUAL AND POWER TAPPING.

Degree: MS, Veterinary Medicine, College of, 2008, Mississippi State University

 Many orthopedic conditions in dogs require the placement of bone screws in the proximal tibial metaphysis. Currently, both cortical and cancellous screws are used clinically… (more)

Subjects/Keywords: canine; mechanical; axial pull-out; screw

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Demko, J. L. (2008). AXIAL PULL-OUT STRENGTH OF 3.5 CORTICAL AND 4.0 CANCELLOUS BONE SCREWS PLACED IN CANINE PROXIMAL TIBIAS USING MANUAL AND POWER TAPPING. (Masters Thesis). Mississippi State University. Retrieved from http://sun.library.msstate.edu/ETD-db/theses/available/etd-03312008-205137/ ;

Chicago Manual of Style (16th Edition):

Demko, Jennifer Lynn. “AXIAL PULL-OUT STRENGTH OF 3.5 CORTICAL AND 4.0 CANCELLOUS BONE SCREWS PLACED IN CANINE PROXIMAL TIBIAS USING MANUAL AND POWER TAPPING.” 2008. Masters Thesis, Mississippi State University. Accessed October 20, 2019. http://sun.library.msstate.edu/ETD-db/theses/available/etd-03312008-205137/ ;.

MLA Handbook (7th Edition):

Demko, Jennifer Lynn. “AXIAL PULL-OUT STRENGTH OF 3.5 CORTICAL AND 4.0 CANCELLOUS BONE SCREWS PLACED IN CANINE PROXIMAL TIBIAS USING MANUAL AND POWER TAPPING.” 2008. Web. 20 Oct 2019.

Vancouver:

Demko JL. AXIAL PULL-OUT STRENGTH OF 3.5 CORTICAL AND 4.0 CANCELLOUS BONE SCREWS PLACED IN CANINE PROXIMAL TIBIAS USING MANUAL AND POWER TAPPING. [Internet] [Masters thesis]. Mississippi State University; 2008. [cited 2019 Oct 20]. Available from: http://sun.library.msstate.edu/ETD-db/theses/available/etd-03312008-205137/ ;.

Council of Science Editors:

Demko JL. AXIAL PULL-OUT STRENGTH OF 3.5 CORTICAL AND 4.0 CANCELLOUS BONE SCREWS PLACED IN CANINE PROXIMAL TIBIAS USING MANUAL AND POWER TAPPING. [Masters Thesis]. Mississippi State University; 2008. Available from: http://sun.library.msstate.edu/ETD-db/theses/available/etd-03312008-205137/ ;


Missouri University of Science and Technology

3. Francka, Ryan M. Screw connections subject to tension pull-out and shear forces.

Degree: M.S. in Civil Engineering, Civil Engineering, Missouri University of Science and Technology

 "Currently, the behavior of screw connections subject to combined tension pull-out and shear forces is not well understood. An experimental study was conducted at Missouri… (more)

Subjects/Keywords: Screw tension pull-out; Civil Engineering

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Francka, R. M. (n.d.). Screw connections subject to tension pull-out and shear forces. (Masters Thesis). Missouri University of Science and Technology. Retrieved from http://scholarsmine.mst.edu/masters_theses/4720

Note: this citation may be lacking information needed for this citation format:
No year of publication.

Chicago Manual of Style (16th Edition):

Francka, Ryan M. “Screw connections subject to tension pull-out and shear forces.” Masters Thesis, Missouri University of Science and Technology. Accessed October 20, 2019. http://scholarsmine.mst.edu/masters_theses/4720.

Note: this citation may be lacking information needed for this citation format:
No year of publication.

MLA Handbook (7th Edition):

Francka, Ryan M. “Screw connections subject to tension pull-out and shear forces.” Web. 20 Oct 2019.

Note: this citation may be lacking information needed for this citation format:
No year of publication.

Vancouver:

Francka RM. Screw connections subject to tension pull-out and shear forces. [Internet] [Masters thesis]. Missouri University of Science and Technology; [cited 2019 Oct 20]. Available from: http://scholarsmine.mst.edu/masters_theses/4720.

Note: this citation may be lacking information needed for this citation format:
No year of publication.

Council of Science Editors:

Francka RM. Screw connections subject to tension pull-out and shear forces. [Masters Thesis]. Missouri University of Science and Technology; Available from: http://scholarsmine.mst.edu/masters_theses/4720

Note: this citation may be lacking information needed for this citation format:
No year of publication.


Brunel University

4. Bennani Kamane, Philippe. Finite element modelling of screw fixation in augmented and non-augmented cancellous bone.

Degree: PhD, 2012, Brunel University

 This research project presents a study of the fixation of screws in augmented and non-augmented cancellous bone at a microscopic scale. It is estimated that… (more)

Subjects/Keywords: 617.1; Orthopaedic screw desgn; Bone augmentation with alcium phosphate cement; Bone screw architecture; Finite element modelling from medical images; Screw pull out simulation

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Bennani Kamane, P. (2012). Finite element modelling of screw fixation in augmented and non-augmented cancellous bone. (Doctoral Dissertation). Brunel University. Retrieved from http://bura.brunel.ac.uk/handle/2438/8716 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.607506

Chicago Manual of Style (16th Edition):

Bennani Kamane, Philippe. “Finite element modelling of screw fixation in augmented and non-augmented cancellous bone.” 2012. Doctoral Dissertation, Brunel University. Accessed October 20, 2019. http://bura.brunel.ac.uk/handle/2438/8716 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.607506.

MLA Handbook (7th Edition):

Bennani Kamane, Philippe. “Finite element modelling of screw fixation in augmented and non-augmented cancellous bone.” 2012. Web. 20 Oct 2019.

Vancouver:

Bennani Kamane P. Finite element modelling of screw fixation in augmented and non-augmented cancellous bone. [Internet] [Doctoral dissertation]. Brunel University; 2012. [cited 2019 Oct 20]. Available from: http://bura.brunel.ac.uk/handle/2438/8716 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.607506.

Council of Science Editors:

Bennani Kamane P. Finite element modelling of screw fixation in augmented and non-augmented cancellous bone. [Doctoral Dissertation]. Brunel University; 2012. Available from: http://bura.brunel.ac.uk/handle/2438/8716 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.607506


Brno University of Technology

5. Ryšavá, Zdeňka. Analýza designu,inserce a vytrhávacích sil u vybraných druhů ortopedických implantátů.

Degree: 2010, Brno University of Technology

 Cílem této bakalářské práce bylo na základě literární rešerše a zrpacování naměřených dat, prokázat vazbu mezi inserční a vytrhávací prací chirurgických implantátu. Práce se zabývá… (more)

Subjects/Keywords: kostni šroub; vytrhávací síla; řezný moment; inserčni práce; vytrhávací práce; korelace; bone screw; pull-out force; insertion torque; insertion work; pull-out work; correlation

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Ryšavá, Z. (2010). Analýza designu,inserce a vytrhávacích sil u vybraných druhů ortopedických implantátů. (Thesis). Brno University of Technology. Retrieved from http://hdl.handle.net/11012/2649

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Ryšavá, Zdeňka. “Analýza designu,inserce a vytrhávacích sil u vybraných druhů ortopedických implantátů. ” 2010. Thesis, Brno University of Technology. Accessed October 20, 2019. http://hdl.handle.net/11012/2649.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Ryšavá, Zdeňka. “Analýza designu,inserce a vytrhávacích sil u vybraných druhů ortopedických implantátů. ” 2010. Web. 20 Oct 2019.

Vancouver:

Ryšavá Z. Analýza designu,inserce a vytrhávacích sil u vybraných druhů ortopedických implantátů. [Internet] [Thesis]. Brno University of Technology; 2010. [cited 2019 Oct 20]. Available from: http://hdl.handle.net/11012/2649.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Ryšavá Z. Analýza designu,inserce a vytrhávacích sil u vybraných druhů ortopedických implantátů. [Thesis]. Brno University of Technology; 2010. Available from: http://hdl.handle.net/11012/2649

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

6. Ferrazzo, Vilmar Antonio. Avaliação da resistência à tração, em diferentes períodos de cicatrização, de mini-parafusos utilizados como ancoragem temporária em ortodontia: estudo em cães da raça Beagle.

Degree: PhD, Ortodontia, 2008, University of São Paulo

Com o objetivo de avaliar a influência do processo de cicatrização óssea sobre o desempenho biomecânico de mini-parafusos utilizados como ancoragem em ortodontia, foram inseridos… (more)

Subjects/Keywords: Absolute anchorage; Ancoragem absoluta; Beagle dogs; Cão Beagle; Ensaio de tração; Mini-parafusos; Mini-screw; Orthodontics; Ortodontia; Pull-out strength

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Ferrazzo, V. A. (2008). Avaliação da resistência à tração, em diferentes períodos de cicatrização, de mini-parafusos utilizados como ancoragem temporária em ortodontia: estudo em cães da raça Beagle. (Doctoral Dissertation). University of São Paulo. Retrieved from http://www.teses.usp.br/teses/disponiveis/23/23151/tde-21012009-144722/ ;

Chicago Manual of Style (16th Edition):

Ferrazzo, Vilmar Antonio. “Avaliação da resistência à tração, em diferentes períodos de cicatrização, de mini-parafusos utilizados como ancoragem temporária em ortodontia: estudo em cães da raça Beagle.” 2008. Doctoral Dissertation, University of São Paulo. Accessed October 20, 2019. http://www.teses.usp.br/teses/disponiveis/23/23151/tde-21012009-144722/ ;.

MLA Handbook (7th Edition):

Ferrazzo, Vilmar Antonio. “Avaliação da resistência à tração, em diferentes períodos de cicatrização, de mini-parafusos utilizados como ancoragem temporária em ortodontia: estudo em cães da raça Beagle.” 2008. Web. 20 Oct 2019.

Vancouver:

Ferrazzo VA. Avaliação da resistência à tração, em diferentes períodos de cicatrização, de mini-parafusos utilizados como ancoragem temporária em ortodontia: estudo em cães da raça Beagle. [Internet] [Doctoral dissertation]. University of São Paulo; 2008. [cited 2019 Oct 20]. Available from: http://www.teses.usp.br/teses/disponiveis/23/23151/tde-21012009-144722/ ;.

Council of Science Editors:

Ferrazzo VA. Avaliação da resistência à tração, em diferentes períodos de cicatrização, de mini-parafusos utilizados como ancoragem temporária em ortodontia: estudo em cães da raça Beagle. [Doctoral Dissertation]. University of São Paulo; 2008. Available from: http://www.teses.usp.br/teses/disponiveis/23/23151/tde-21012009-144722/ ;

.