Advanced search options

Advanced Search Options 🞨

Browse by author name (“Author name starts with…”).

Find ETDs with:

in
/  
in
/  
in
/  
in

Written in Published in Earliest date Latest date

Sorted by

Results per page:

Sorted by: relevance · author · university · dateNew search

You searched for subject:(Phasor measurement units). Showing records 1 – 30 of 57 total matches.

[1] [2]

Search Limiters

Last 2 Years | English Only

Degrees

Levels

▼ Search Limiters


University of Illinois – Urbana-Champaign

1. Gegner, Kathleen M. Phasor measurement unit data visualizations and their role in improving operation of the electric grid.

Degree: MS, Electrical & Computer Engr, 2017, University of Illinois – Urbana-Champaign

 In the energy industry, as in many other industries, data is growing faster than the tools needed to transform it into meaningful insights, decisions, and… (more)

Subjects/Keywords: Phasor measurement units; Data visualization; Power systems

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Gegner, K. M. (2017). Phasor measurement unit data visualizations and their role in improving operation of the electric grid. (Thesis). University of Illinois – Urbana-Champaign. Retrieved from http://hdl.handle.net/2142/97442

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Gegner, Kathleen M. “Phasor measurement unit data visualizations and their role in improving operation of the electric grid.” 2017. Thesis, University of Illinois – Urbana-Champaign. Accessed April 17, 2021. http://hdl.handle.net/2142/97442.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Gegner, Kathleen M. “Phasor measurement unit data visualizations and their role in improving operation of the electric grid.” 2017. Web. 17 Apr 2021.

Vancouver:

Gegner KM. Phasor measurement unit data visualizations and their role in improving operation of the electric grid. [Internet] [Thesis]. University of Illinois – Urbana-Champaign; 2017. [cited 2021 Apr 17]. Available from: http://hdl.handle.net/2142/97442.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Gegner KM. Phasor measurement unit data visualizations and their role in improving operation of the electric grid. [Thesis]. University of Illinois – Urbana-Champaign; 2017. Available from: http://hdl.handle.net/2142/97442

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Manchester

2. Nechifor, Alexandru. Estimation of Dynamic Load Model Parameters using Real-time Measurements and a Flexible Phasor Data Concentrator.

Degree: 2017, University of Manchester

 This thesis presents the development of an advanced monitoring platform aimed at increasing the transmission/distribution network operator’s understanding of load dynamics. The advanced monitoring platform… (more)

Subjects/Keywords: Load Modelling; Phasor Measurement Units; Phasor Data Concentrator; Java Enterprise Edition

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Nechifor, A. (2017). Estimation of Dynamic Load Model Parameters using Real-time Measurements and a Flexible Phasor Data Concentrator. (Doctoral Dissertation). University of Manchester. Retrieved from http://www.manchester.ac.uk/escholar/uk-ac-man-scw:309834

Chicago Manual of Style (16th Edition):

Nechifor, Alexandru. “Estimation of Dynamic Load Model Parameters using Real-time Measurements and a Flexible Phasor Data Concentrator.” 2017. Doctoral Dissertation, University of Manchester. Accessed April 17, 2021. http://www.manchester.ac.uk/escholar/uk-ac-man-scw:309834.

MLA Handbook (7th Edition):

Nechifor, Alexandru. “Estimation of Dynamic Load Model Parameters using Real-time Measurements and a Flexible Phasor Data Concentrator.” 2017. Web. 17 Apr 2021.

Vancouver:

Nechifor A. Estimation of Dynamic Load Model Parameters using Real-time Measurements and a Flexible Phasor Data Concentrator. [Internet] [Doctoral dissertation]. University of Manchester; 2017. [cited 2021 Apr 17]. Available from: http://www.manchester.ac.uk/escholar/uk-ac-man-scw:309834.

Council of Science Editors:

Nechifor A. Estimation of Dynamic Load Model Parameters using Real-time Measurements and a Flexible Phasor Data Concentrator. [Doctoral Dissertation]. University of Manchester; 2017. Available from: http://www.manchester.ac.uk/escholar/uk-ac-man-scw:309834


University of Manchester

3. Nechifor, Alexandru. Estimation of dynamic load model parameters using real-time measurements and a flexible phasor data concentrator.

Degree: PhD, 2017, University of Manchester

 This thesis presents the development of an advanced monitoring platform aimed at increasing the transmission/distribution network operator's understanding of load dynamics. The advanced monitoring platform… (more)

Subjects/Keywords: Java Enterprise Edition; Phasor Data Concentrator; Load Modelling; Phasor Measurement Units

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Nechifor, A. (2017). Estimation of dynamic load model parameters using real-time measurements and a flexible phasor data concentrator. (Doctoral Dissertation). University of Manchester. Retrieved from https://www.research.manchester.ac.uk/portal/en/theses/estimation-of-dynamic-load-model-parameters-using-realtime-measurements-and-a-flexible-phasor-data-concentrator(f177f6e6-72e6-4828-92cb-49e8112fb47f).html ; https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.822882

Chicago Manual of Style (16th Edition):

Nechifor, Alexandru. “Estimation of dynamic load model parameters using real-time measurements and a flexible phasor data concentrator.” 2017. Doctoral Dissertation, University of Manchester. Accessed April 17, 2021. https://www.research.manchester.ac.uk/portal/en/theses/estimation-of-dynamic-load-model-parameters-using-realtime-measurements-and-a-flexible-phasor-data-concentrator(f177f6e6-72e6-4828-92cb-49e8112fb47f).html ; https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.822882.

MLA Handbook (7th Edition):

Nechifor, Alexandru. “Estimation of dynamic load model parameters using real-time measurements and a flexible phasor data concentrator.” 2017. Web. 17 Apr 2021.

Vancouver:

Nechifor A. Estimation of dynamic load model parameters using real-time measurements and a flexible phasor data concentrator. [Internet] [Doctoral dissertation]. University of Manchester; 2017. [cited 2021 Apr 17]. Available from: https://www.research.manchester.ac.uk/portal/en/theses/estimation-of-dynamic-load-model-parameters-using-realtime-measurements-and-a-flexible-phasor-data-concentrator(f177f6e6-72e6-4828-92cb-49e8112fb47f).html ; https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.822882.

Council of Science Editors:

Nechifor A. Estimation of dynamic load model parameters using real-time measurements and a flexible phasor data concentrator. [Doctoral Dissertation]. University of Manchester; 2017. Available from: https://www.research.manchester.ac.uk/portal/en/theses/estimation-of-dynamic-load-model-parameters-using-realtime-measurements-and-a-flexible-phasor-data-concentrator(f177f6e6-72e6-4828-92cb-49e8112fb47f).html ; https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.822882


University of Toronto

4. Singh, Amrit. Phasor Measurement Unit Enabled Power Dispatch and Autonomous Black Start of AC Microgrids.

Degree: 2018, University of Toronto

The aim of this thesis is to develop a mathematical model and control for black start and power dispatch of AC microgrids powered by converter… (more)

Subjects/Keywords: ac microgrids; black start; Phasor measurement units; 0544

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Singh, A. (2018). Phasor Measurement Unit Enabled Power Dispatch and Autonomous Black Start of AC Microgrids. (Masters Thesis). University of Toronto. Retrieved from http://hdl.handle.net/1807/89531

Chicago Manual of Style (16th Edition):

Singh, Amrit. “Phasor Measurement Unit Enabled Power Dispatch and Autonomous Black Start of AC Microgrids.” 2018. Masters Thesis, University of Toronto. Accessed April 17, 2021. http://hdl.handle.net/1807/89531.

MLA Handbook (7th Edition):

Singh, Amrit. “Phasor Measurement Unit Enabled Power Dispatch and Autonomous Black Start of AC Microgrids.” 2018. Web. 17 Apr 2021.

Vancouver:

Singh A. Phasor Measurement Unit Enabled Power Dispatch and Autonomous Black Start of AC Microgrids. [Internet] [Masters thesis]. University of Toronto; 2018. [cited 2021 Apr 17]. Available from: http://hdl.handle.net/1807/89531.

Council of Science Editors:

Singh A. Phasor Measurement Unit Enabled Power Dispatch and Autonomous Black Start of AC Microgrids. [Masters Thesis]. University of Toronto; 2018. Available from: http://hdl.handle.net/1807/89531


Brunel University

5. Golshani, Mohammad. Novel performance evaluation of information and communication technologies to enable wide area monitoring systems for enhanced transmission network operation.

Degree: PhD, 2015, Brunel University

 The penetration of renewable energy sources has increased significantly in recent years due to the ongoing depletion of conventional resources and the transition to a… (more)

Subjects/Keywords: 621.31; Phasor measurement units; Open stantards; Smart grid; Power system

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Golshani, M. (2015). Novel performance evaluation of information and communication technologies to enable wide area monitoring systems for enhanced transmission network operation. (Doctoral Dissertation). Brunel University. Retrieved from http://bura.brunel.ac.uk/handle/2438/11918 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.678931

Chicago Manual of Style (16th Edition):

Golshani, Mohammad. “Novel performance evaluation of information and communication technologies to enable wide area monitoring systems for enhanced transmission network operation.” 2015. Doctoral Dissertation, Brunel University. Accessed April 17, 2021. http://bura.brunel.ac.uk/handle/2438/11918 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.678931.

MLA Handbook (7th Edition):

Golshani, Mohammad. “Novel performance evaluation of information and communication technologies to enable wide area monitoring systems for enhanced transmission network operation.” 2015. Web. 17 Apr 2021.

Vancouver:

Golshani M. Novel performance evaluation of information and communication technologies to enable wide area monitoring systems for enhanced transmission network operation. [Internet] [Doctoral dissertation]. Brunel University; 2015. [cited 2021 Apr 17]. Available from: http://bura.brunel.ac.uk/handle/2438/11918 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.678931.

Council of Science Editors:

Golshani M. Novel performance evaluation of information and communication technologies to enable wide area monitoring systems for enhanced transmission network operation. [Doctoral Dissertation]. Brunel University; 2015. Available from: http://bura.brunel.ac.uk/handle/2438/11918 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.678931


Delft University of Technology

6. Radević, Isidora (author). SDFT Based PMU Prototype.

Degree: 2018, Delft University of Technology

Presently, phasor measurement units (PMUs) are the most accurate and advanced time-synchronized technology. PMUs are the main element of the Wide-Area Monitoring, Protection and Control… (more)

Subjects/Keywords: real-time monitoring; phasor measurement units; Embedded Systems

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Radević, I. (. (2018). SDFT Based PMU Prototype. (Masters Thesis). Delft University of Technology. Retrieved from http://resolver.tudelft.nl/uuid:604c45b7-40c8-4161-8898-6111c4648813

Chicago Manual of Style (16th Edition):

Radević, Isidora (author). “SDFT Based PMU Prototype.” 2018. Masters Thesis, Delft University of Technology. Accessed April 17, 2021. http://resolver.tudelft.nl/uuid:604c45b7-40c8-4161-8898-6111c4648813.

MLA Handbook (7th Edition):

Radević, Isidora (author). “SDFT Based PMU Prototype.” 2018. Web. 17 Apr 2021.

Vancouver:

Radević I(. SDFT Based PMU Prototype. [Internet] [Masters thesis]. Delft University of Technology; 2018. [cited 2021 Apr 17]. Available from: http://resolver.tudelft.nl/uuid:604c45b7-40c8-4161-8898-6111c4648813.

Council of Science Editors:

Radević I(. SDFT Based PMU Prototype. [Masters Thesis]. Delft University of Technology; 2018. Available from: http://resolver.tudelft.nl/uuid:604c45b7-40c8-4161-8898-6111c4648813


University of Illinois – Urbana-Champaign

7. Kirihara, Kenta. Big data in power systems: a statistical approach on synchrophasor application.

Degree: MS, Electrical & Computer Engineering, 2015, University of Illinois – Urbana-Champaign

Phasor Measurement Units (PMUs) are regarded as one of the most valuable device on the power system. PMUs, being devices that are found on buses… (more)

Subjects/Keywords: Synchrophasor; Phasor Measurement Units (PMU); big data; statistics

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Kirihara, K. (2015). Big data in power systems: a statistical approach on synchrophasor application. (Thesis). University of Illinois – Urbana-Champaign. Retrieved from http://hdl.handle.net/2142/87999

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Kirihara, Kenta. “Big data in power systems: a statistical approach on synchrophasor application.” 2015. Thesis, University of Illinois – Urbana-Champaign. Accessed April 17, 2021. http://hdl.handle.net/2142/87999.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Kirihara, Kenta. “Big data in power systems: a statistical approach on synchrophasor application.” 2015. Web. 17 Apr 2021.

Vancouver:

Kirihara K. Big data in power systems: a statistical approach on synchrophasor application. [Internet] [Thesis]. University of Illinois – Urbana-Champaign; 2015. [cited 2021 Apr 17]. Available from: http://hdl.handle.net/2142/87999.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Kirihara K. Big data in power systems: a statistical approach on synchrophasor application. [Thesis]. University of Illinois – Urbana-Champaign; 2015. Available from: http://hdl.handle.net/2142/87999

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Washington State University

8. [No author]. STOCHASTIC SUBSPACE METHODS FOR LARGE POWER SYSTEM OSCILLATION MONITORING .

Degree: 2015, Washington State University

 Accurate knowledge and estimation of the low-frequency electromechanical oscillations are of vital importance for operational reliability of any power system. Such mode estimation basically can… (more)

Subjects/Keywords: Electrical engineering; Electromechanical Oscillation; Forced Oscillation; Phasor Measurement Units; Power System Stability; Subspace Identification

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

author], [. (2015). STOCHASTIC SUBSPACE METHODS FOR LARGE POWER SYSTEM OSCILLATION MONITORING . (Thesis). Washington State University. Retrieved from http://hdl.handle.net/2376/6169

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

author], [No. “STOCHASTIC SUBSPACE METHODS FOR LARGE POWER SYSTEM OSCILLATION MONITORING .” 2015. Thesis, Washington State University. Accessed April 17, 2021. http://hdl.handle.net/2376/6169.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

author], [No. “STOCHASTIC SUBSPACE METHODS FOR LARGE POWER SYSTEM OSCILLATION MONITORING .” 2015. Web. 17 Apr 2021.

Vancouver:

author] [. STOCHASTIC SUBSPACE METHODS FOR LARGE POWER SYSTEM OSCILLATION MONITORING . [Internet] [Thesis]. Washington State University; 2015. [cited 2021 Apr 17]. Available from: http://hdl.handle.net/2376/6169.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

author] [. STOCHASTIC SUBSPACE METHODS FOR LARGE POWER SYSTEM OSCILLATION MONITORING . [Thesis]. Washington State University; 2015. Available from: http://hdl.handle.net/2376/6169

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Northeastern University

9. Emami, Roozbeh. Enhancement of network monitoring & security analysis using phasor measurement units.

Degree: PhD, Department of Electrical and Computer Engineering, 2011, Northeastern University

 Among various facilitators of the smart grid are the phasor measurement units (PMU) which are rapidly populating substations in today's interconnected transmission systems. This dissertation… (more)

Subjects/Keywords: Network Monitoring; Phasor Measurement Units; Security Analysis; Electrical and Computer Engineering; Engineering

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Emami, R. (2011). Enhancement of network monitoring & security analysis using phasor measurement units. (Doctoral Dissertation). Northeastern University. Retrieved from http://hdl.handle.net/2047/d20000839

Chicago Manual of Style (16th Edition):

Emami, Roozbeh. “Enhancement of network monitoring & security analysis using phasor measurement units.” 2011. Doctoral Dissertation, Northeastern University. Accessed April 17, 2021. http://hdl.handle.net/2047/d20000839.

MLA Handbook (7th Edition):

Emami, Roozbeh. “Enhancement of network monitoring & security analysis using phasor measurement units.” 2011. Web. 17 Apr 2021.

Vancouver:

Emami R. Enhancement of network monitoring & security analysis using phasor measurement units. [Internet] [Doctoral dissertation]. Northeastern University; 2011. [cited 2021 Apr 17]. Available from: http://hdl.handle.net/2047/d20000839.

Council of Science Editors:

Emami R. Enhancement of network monitoring & security analysis using phasor measurement units. [Doctoral Dissertation]. Northeastern University; 2011. Available from: http://hdl.handle.net/2047/d20000839


Brunel University

10. Khan, Mukhtaj. Hadoop performance modeling and job optimization for big data analytics.

Degree: PhD, 2015, Brunel University

 Big data has received a momentum from both academia and industry. The MapReduce model has emerged into a major computing model in support of big… (more)

Subjects/Keywords: 005.7; Resource provisioning; Phasor measurement units; Gene expression programming; Parallel detrended fluctuation analysis; Job estimation

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Khan, M. (2015). Hadoop performance modeling and job optimization for big data analytics. (Doctoral Dissertation). Brunel University. Retrieved from http://bura.brunel.ac.uk/handle/2438/11078 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.655905

Chicago Manual of Style (16th Edition):

Khan, Mukhtaj. “Hadoop performance modeling and job optimization for big data analytics.” 2015. Doctoral Dissertation, Brunel University. Accessed April 17, 2021. http://bura.brunel.ac.uk/handle/2438/11078 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.655905.

MLA Handbook (7th Edition):

Khan, Mukhtaj. “Hadoop performance modeling and job optimization for big data analytics.” 2015. Web. 17 Apr 2021.

Vancouver:

Khan M. Hadoop performance modeling and job optimization for big data analytics. [Internet] [Doctoral dissertation]. Brunel University; 2015. [cited 2021 Apr 17]. Available from: http://bura.brunel.ac.uk/handle/2438/11078 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.655905.

Council of Science Editors:

Khan M. Hadoop performance modeling and job optimization for big data analytics. [Doctoral Dissertation]. Brunel University; 2015. Available from: http://bura.brunel.ac.uk/handle/2438/11078 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.655905


Virginia Tech

11. Gyawali, Sanij. Dynamic Load Modeling from PSSE-Simulated Disturbance Data using Machine Learning.

Degree: MS, Electrical Engineering, 2020, Virginia Tech

 Independent system Operators (ISO) and Distribution system operators (DSO) have a responsibility to provide uninterrupted power supply to consumers. That along with the longing to… (more)

Subjects/Keywords: Dynamic Load Modeling; Neural Network; Long-Short Term Memory; Support Vector Regression; Phasor Measurement Units

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Gyawali, S. (2020). Dynamic Load Modeling from PSSE-Simulated Disturbance Data using Machine Learning. (Masters Thesis). Virginia Tech. Retrieved from http://hdl.handle.net/10919/100591

Chicago Manual of Style (16th Edition):

Gyawali, Sanij. “Dynamic Load Modeling from PSSE-Simulated Disturbance Data using Machine Learning.” 2020. Masters Thesis, Virginia Tech. Accessed April 17, 2021. http://hdl.handle.net/10919/100591.

MLA Handbook (7th Edition):

Gyawali, Sanij. “Dynamic Load Modeling from PSSE-Simulated Disturbance Data using Machine Learning.” 2020. Web. 17 Apr 2021.

Vancouver:

Gyawali S. Dynamic Load Modeling from PSSE-Simulated Disturbance Data using Machine Learning. [Internet] [Masters thesis]. Virginia Tech; 2020. [cited 2021 Apr 17]. Available from: http://hdl.handle.net/10919/100591.

Council of Science Editors:

Gyawali S. Dynamic Load Modeling from PSSE-Simulated Disturbance Data using Machine Learning. [Masters Thesis]. Virginia Tech; 2020. Available from: http://hdl.handle.net/10919/100591


University of Illinois – Urbana-Champaign

12. Lu, Miao. Malicious data detection and localization in state estimation leveraging system losses.

Degree: MS, Electrical & Computer Engr, 2015, University of Illinois – Urbana-Champaign

 In power systems, economic dispatch, contingency analysis, and the detection of faulty equipment rely on the output of the state estimator. Typically, state estimations are… (more)

Subjects/Keywords: false data injection; phasor measurement units; state estimation; power system cyber security

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Lu, M. (2015). Malicious data detection and localization in state estimation leveraging system losses. (Thesis). University of Illinois – Urbana-Champaign. Retrieved from http://hdl.handle.net/2142/78661

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Lu, Miao. “Malicious data detection and localization in state estimation leveraging system losses.” 2015. Thesis, University of Illinois – Urbana-Champaign. Accessed April 17, 2021. http://hdl.handle.net/2142/78661.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Lu, Miao. “Malicious data detection and localization in state estimation leveraging system losses.” 2015. Web. 17 Apr 2021.

Vancouver:

Lu M. Malicious data detection and localization in state estimation leveraging system losses. [Internet] [Thesis]. University of Illinois – Urbana-Champaign; 2015. [cited 2021 Apr 17]. Available from: http://hdl.handle.net/2142/78661.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Lu M. Malicious data detection and localization in state estimation leveraging system losses. [Thesis]. University of Illinois – Urbana-Champaign; 2015. Available from: http://hdl.handle.net/2142/78661

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Illinois – Urbana-Champaign

13. Zhang, Christopher Benedict. Application of PMU for system stability analysis with Thevenin equivalent modeling.

Degree: MS, Electrical & Computer Engr, 2016, University of Illinois – Urbana-Champaign

 This thesis is a continuation and verification of the proposed method to analyze power system stability by utilizing phasor measurement units (PMUs). In the past… (more)

Subjects/Keywords: Phasor measurement units (PMU); Thevenin equivalent; System stability; Voltage stability; Angle stability

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Zhang, C. B. (2016). Application of PMU for system stability analysis with Thevenin equivalent modeling. (Thesis). University of Illinois – Urbana-Champaign. Retrieved from http://hdl.handle.net/2142/90763

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Zhang, Christopher Benedict. “Application of PMU for system stability analysis with Thevenin equivalent modeling.” 2016. Thesis, University of Illinois – Urbana-Champaign. Accessed April 17, 2021. http://hdl.handle.net/2142/90763.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Zhang, Christopher Benedict. “Application of PMU for system stability analysis with Thevenin equivalent modeling.” 2016. Web. 17 Apr 2021.

Vancouver:

Zhang CB. Application of PMU for system stability analysis with Thevenin equivalent modeling. [Internet] [Thesis]. University of Illinois – Urbana-Champaign; 2016. [cited 2021 Apr 17]. Available from: http://hdl.handle.net/2142/90763.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Zhang CB. Application of PMU for system stability analysis with Thevenin equivalent modeling. [Thesis]. University of Illinois – Urbana-Champaign; 2016. Available from: http://hdl.handle.net/2142/90763

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Illinois – Urbana-Champaign

14. Jiang, Xichen. Real-time power system topology change detection and identification.

Degree: PhD, Electrical & Computer Engr, 2016, University of Illinois – Urbana-Champaign

 This thesis proposes a framework for detection and identification of system topological changes in near real-time that utilizes the statistical properties of electricity generation and… (more)

Subjects/Keywords: Phasor measurement units (PMU); Line Outage; Detection; Identification; Estimation; CuSum; Quickest Change; Topology Change

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Jiang, X. (2016). Real-time power system topology change detection and identification. (Doctoral Dissertation). University of Illinois – Urbana-Champaign. Retrieved from http://hdl.handle.net/2142/92738

Chicago Manual of Style (16th Edition):

Jiang, Xichen. “Real-time power system topology change detection and identification.” 2016. Doctoral Dissertation, University of Illinois – Urbana-Champaign. Accessed April 17, 2021. http://hdl.handle.net/2142/92738.

MLA Handbook (7th Edition):

Jiang, Xichen. “Real-time power system topology change detection and identification.” 2016. Web. 17 Apr 2021.

Vancouver:

Jiang X. Real-time power system topology change detection and identification. [Internet] [Doctoral dissertation]. University of Illinois – Urbana-Champaign; 2016. [cited 2021 Apr 17]. Available from: http://hdl.handle.net/2142/92738.

Council of Science Editors:

Jiang X. Real-time power system topology change detection and identification. [Doctoral Dissertation]. University of Illinois – Urbana-Champaign; 2016. Available from: http://hdl.handle.net/2142/92738


University of Manchester

15. Guo, Tingyan. On-line Identification of Power System Dynamic Signature Using PMU Measurements and Data Mining.

Degree: 2015, University of Manchester

 This thesis develops a robust methodology for on-line identification of power system dynamic signature based on incoming system responses from Phasor Measurement Units (PMUs) in… (more)

Subjects/Keywords: Power system dynamic signature; Transient stability; Corrective control; Phasor measurement units; Data mining; Classification; Clustering

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Guo, T. (2015). On-line Identification of Power System Dynamic Signature Using PMU Measurements and Data Mining. (Doctoral Dissertation). University of Manchester. Retrieved from http://www.manchester.ac.uk/escholar/uk-ac-man-scw:271753

Chicago Manual of Style (16th Edition):

Guo, Tingyan. “On-line Identification of Power System Dynamic Signature Using PMU Measurements and Data Mining.” 2015. Doctoral Dissertation, University of Manchester. Accessed April 17, 2021. http://www.manchester.ac.uk/escholar/uk-ac-man-scw:271753.

MLA Handbook (7th Edition):

Guo, Tingyan. “On-line Identification of Power System Dynamic Signature Using PMU Measurements and Data Mining.” 2015. Web. 17 Apr 2021.

Vancouver:

Guo T. On-line Identification of Power System Dynamic Signature Using PMU Measurements and Data Mining. [Internet] [Doctoral dissertation]. University of Manchester; 2015. [cited 2021 Apr 17]. Available from: http://www.manchester.ac.uk/escholar/uk-ac-man-scw:271753.

Council of Science Editors:

Guo T. On-line Identification of Power System Dynamic Signature Using PMU Measurements and Data Mining. [Doctoral Dissertation]. University of Manchester; 2015. Available from: http://www.manchester.ac.uk/escholar/uk-ac-man-scw:271753


Northeastern University

16. Korkali, Mert. Strategic and robust deployment of synchronized phasor measurement units with restricted channel capacity.

Degree: MS, Department of Electrical and Computer Engineering, 2010, Northeastern University

 Synchronized phasor measurements are changing the way power systems are monitored and operated. Their efficient incorporation into various applications, which are executed in energy management… (more)

Subjects/Keywords: electrical engineering; synchronized phasor measurement units (PMUs); network observability; zero-injection measurements; channel limits; Electrical and Computer Engineering; Engineering

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Korkali, M. (2010). Strategic and robust deployment of synchronized phasor measurement units with restricted channel capacity. (Masters Thesis). Northeastern University. Retrieved from http://hdl.handle.net/2047/d20001023

Chicago Manual of Style (16th Edition):

Korkali, Mert. “Strategic and robust deployment of synchronized phasor measurement units with restricted channel capacity.” 2010. Masters Thesis, Northeastern University. Accessed April 17, 2021. http://hdl.handle.net/2047/d20001023.

MLA Handbook (7th Edition):

Korkali, Mert. “Strategic and robust deployment of synchronized phasor measurement units with restricted channel capacity.” 2010. Web. 17 Apr 2021.

Vancouver:

Korkali M. Strategic and robust deployment of synchronized phasor measurement units with restricted channel capacity. [Internet] [Masters thesis]. Northeastern University; 2010. [cited 2021 Apr 17]. Available from: http://hdl.handle.net/2047/d20001023.

Council of Science Editors:

Korkali M. Strategic and robust deployment of synchronized phasor measurement units with restricted channel capacity. [Masters Thesis]. Northeastern University; 2010. Available from: http://hdl.handle.net/2047/d20001023


Northeastern University

17. Gol, Murat. Incorporation of PMUs in power system state estimation.

Degree: PhD, Department of Electrical and Computer Engineering, 2014, Northeastern University

 This dissertation describes new methods to efficiently incorporate PMUs in power system state estimation, which plays a key role in effective operation of power markets… (more)

Subjects/Keywords: Least absolute value; Observability; Phasor measurement units; State estimation; Synchrophasor; Electrical and Computer Engineering; Power and Energy

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Gol, M. (2014). Incorporation of PMUs in power system state estimation. (Doctoral Dissertation). Northeastern University. Retrieved from http://hdl.handle.net/2047/d20004973

Chicago Manual of Style (16th Edition):

Gol, Murat. “Incorporation of PMUs in power system state estimation.” 2014. Doctoral Dissertation, Northeastern University. Accessed April 17, 2021. http://hdl.handle.net/2047/d20004973.

MLA Handbook (7th Edition):

Gol, Murat. “Incorporation of PMUs in power system state estimation.” 2014. Web. 17 Apr 2021.

Vancouver:

Gol M. Incorporation of PMUs in power system state estimation. [Internet] [Doctoral dissertation]. Northeastern University; 2014. [cited 2021 Apr 17]. Available from: http://hdl.handle.net/2047/d20004973.

Council of Science Editors:

Gol M. Incorporation of PMUs in power system state estimation. [Doctoral Dissertation]. Northeastern University; 2014. Available from: http://hdl.handle.net/2047/d20004973


University of Manitoba

18. Wijeweera, Don Gayan Prabath. Development of an equivalent circuit of a large power system for real- time security assessment.

Degree: Electrical and Computer Engineering, 2016, University of Manitoba

 More and more system operators are interested in calculating transfer capability in real-time using real-time power flow models generated from the Energy Management System (EMS).… (more)

Subjects/Keywords: Equivalent circuits; Power system interconnection; Power system security; Power system simulation; Power system analysis computing; Power system modelling; Phasor measurement units

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Wijeweera, D. G. P. (2016). Development of an equivalent circuit of a large power system for real- time security assessment. (Thesis). University of Manitoba. Retrieved from http://hdl.handle.net/1993/31927

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Wijeweera, Don Gayan Prabath. “Development of an equivalent circuit of a large power system for real- time security assessment.” 2016. Thesis, University of Manitoba. Accessed April 17, 2021. http://hdl.handle.net/1993/31927.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Wijeweera, Don Gayan Prabath. “Development of an equivalent circuit of a large power system for real- time security assessment.” 2016. Web. 17 Apr 2021.

Vancouver:

Wijeweera DGP. Development of an equivalent circuit of a large power system for real- time security assessment. [Internet] [Thesis]. University of Manitoba; 2016. [cited 2021 Apr 17]. Available from: http://hdl.handle.net/1993/31927.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Wijeweera DGP. Development of an equivalent circuit of a large power system for real- time security assessment. [Thesis]. University of Manitoba; 2016. Available from: http://hdl.handle.net/1993/31927

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Manitoba

19. KONARA MUDIYANSELAGE, ANUPAMA. Synchrophasor-based robust power system stabilizer design using eigenstructure assignment.

Degree: Electrical and Computer Engineering, 2015, University of Manitoba

 Power system stabilizers (PSSs) provide the most economical way to improve damping of electro-mechanical oscillations in electrical power systems. Synchrophasor technology enables the use of… (more)

Subjects/Keywords: Electro-mechanical oscillations; Power system stabilizers; Eigenstructure assignment; Phasor measurement units; Robust controller; Data transmission delays

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

KONARA MUDIYANSELAGE, A. (2015). Synchrophasor-based robust power system stabilizer design using eigenstructure assignment. (Thesis). University of Manitoba. Retrieved from http://hdl.handle.net/1993/30973

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

KONARA MUDIYANSELAGE, ANUPAMA. “Synchrophasor-based robust power system stabilizer design using eigenstructure assignment.” 2015. Thesis, University of Manitoba. Accessed April 17, 2021. http://hdl.handle.net/1993/30973.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

KONARA MUDIYANSELAGE, ANUPAMA. “Synchrophasor-based robust power system stabilizer design using eigenstructure assignment.” 2015. Web. 17 Apr 2021.

Vancouver:

KONARA MUDIYANSELAGE A. Synchrophasor-based robust power system stabilizer design using eigenstructure assignment. [Internet] [Thesis]. University of Manitoba; 2015. [cited 2021 Apr 17]. Available from: http://hdl.handle.net/1993/30973.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

KONARA MUDIYANSELAGE A. Synchrophasor-based robust power system stabilizer design using eigenstructure assignment. [Thesis]. University of Manitoba; 2015. Available from: http://hdl.handle.net/1993/30973

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Iowa State University

20. Ramapuram Matavalam, Amarsagar Reddy. Online monitoring & mitigation of voltage instability in transmission and distribution systems using synchrophasors.

Degree: 2019, Iowa State University

 With the increasing need for economic operation of the power grid, the system is being operated closer to their limits and there is a need… (more)

Subjects/Keywords: Data Driven Modeling; Delayed Voltage Recovery; Phasor Measurement Units; Thevenin Equivalent; Transmission & Distribution Interaction; Voltage Stability; Electrical and Electronics

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Ramapuram Matavalam, A. R. (2019). Online monitoring & mitigation of voltage instability in transmission and distribution systems using synchrophasors. (Thesis). Iowa State University. Retrieved from https://lib.dr.iastate.edu/etd/17545

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Ramapuram Matavalam, Amarsagar Reddy. “Online monitoring & mitigation of voltage instability in transmission and distribution systems using synchrophasors.” 2019. Thesis, Iowa State University. Accessed April 17, 2021. https://lib.dr.iastate.edu/etd/17545.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Ramapuram Matavalam, Amarsagar Reddy. “Online monitoring & mitigation of voltage instability in transmission and distribution systems using synchrophasors.” 2019. Web. 17 Apr 2021.

Vancouver:

Ramapuram Matavalam AR. Online monitoring & mitigation of voltage instability in transmission and distribution systems using synchrophasors. [Internet] [Thesis]. Iowa State University; 2019. [cited 2021 Apr 17]. Available from: https://lib.dr.iastate.edu/etd/17545.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Ramapuram Matavalam AR. Online monitoring & mitigation of voltage instability in transmission and distribution systems using synchrophasors. [Thesis]. Iowa State University; 2019. Available from: https://lib.dr.iastate.edu/etd/17545

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Delft University of Technology

21. den Boer, Tjerk (author). Validation of Dynamic Power System Models using Synchrophasor Measurements.

Degree: 2020, Delft University of Technology

A dynamic power system model cannot perfectly predict the behaviour of a physical power system. Model validation tries to answer the question whether the model… (more)

Subjects/Keywords: power system stability; power system dynamics; model validation; PMU; phasor measurement units; Synchrophasor; System Wide Simulation; Hybrid Dynamic Simulation

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

den Boer, T. (. (2020). Validation of Dynamic Power System Models using Synchrophasor Measurements. (Masters Thesis). Delft University of Technology. Retrieved from http://resolver.tudelft.nl/uuid:b871e4b7-451c-493e-9d2d-3d0b0d76a15e

Chicago Manual of Style (16th Edition):

den Boer, Tjerk (author). “Validation of Dynamic Power System Models using Synchrophasor Measurements.” 2020. Masters Thesis, Delft University of Technology. Accessed April 17, 2021. http://resolver.tudelft.nl/uuid:b871e4b7-451c-493e-9d2d-3d0b0d76a15e.

MLA Handbook (7th Edition):

den Boer, Tjerk (author). “Validation of Dynamic Power System Models using Synchrophasor Measurements.” 2020. Web. 17 Apr 2021.

Vancouver:

den Boer T(. Validation of Dynamic Power System Models using Synchrophasor Measurements. [Internet] [Masters thesis]. Delft University of Technology; 2020. [cited 2021 Apr 17]. Available from: http://resolver.tudelft.nl/uuid:b871e4b7-451c-493e-9d2d-3d0b0d76a15e.

Council of Science Editors:

den Boer T(. Validation of Dynamic Power System Models using Synchrophasor Measurements. [Masters Thesis]. Delft University of Technology; 2020. Available from: http://resolver.tudelft.nl/uuid:b871e4b7-451c-493e-9d2d-3d0b0d76a15e

22. Quinlan, Michael Brock. Development and deployment of a residential voltage level phasor measurement unit.

Degree: MS, Electrical & Computer Engr, 2015, University of Illinois – Urbana-Champaign

 This thesis aims to investigate the production and transmission of synchrophasor data. Synchrophasor data provides near real-time data at widely separated points across the power… (more)

Subjects/Keywords: Phasor Measurement Units (PMU); Distribution Level

…x5B;7] H.G. Abood, and V. Sreeram,”A review on phasor measurement units placement for… …Sauer, "A one-phase, distribution-level phasor measurement unit for post-event analysis… …OpenPMU platform for open-source phasor measurements," Instrumentation and Measurement… …While the data produced by the units is becoming more transparent, as can be seen again in… …part, to the many different ways to implement a device generating phasor measurements. We… 

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Quinlan, M. B. (2015). Development and deployment of a residential voltage level phasor measurement unit. (Thesis). University of Illinois – Urbana-Champaign. Retrieved from http://hdl.handle.net/2142/78652

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Quinlan, Michael Brock. “Development and deployment of a residential voltage level phasor measurement unit.” 2015. Thesis, University of Illinois – Urbana-Champaign. Accessed April 17, 2021. http://hdl.handle.net/2142/78652.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Quinlan, Michael Brock. “Development and deployment of a residential voltage level phasor measurement unit.” 2015. Web. 17 Apr 2021.

Vancouver:

Quinlan MB. Development and deployment of a residential voltage level phasor measurement unit. [Internet] [Thesis]. University of Illinois – Urbana-Champaign; 2015. [cited 2021 Apr 17]. Available from: http://hdl.handle.net/2142/78652.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Quinlan MB. Development and deployment of a residential voltage level phasor measurement unit. [Thesis]. University of Illinois – Urbana-Champaign; 2015. Available from: http://hdl.handle.net/2142/78652

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Kansas State University

23. Ahmed, Sheikh. PMU based PSS and SVC fuzzy controller design for angular stability analysis.

Degree: MS, Department of Electrical and Computer Engineering, 2015, Kansas State University

 Variability in power systems is increasing due to pushing the system to limits for economic purposes, the inclusion of new energy sources like wind turbines… (more)

Subjects/Keywords: Power System Stabilizer; Phasor Measurement Units;

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Ahmed, S. (2015). PMU based PSS and SVC fuzzy controller design for angular stability analysis. (Masters Thesis). Kansas State University. Retrieved from http://hdl.handle.net/2097/20547

Chicago Manual of Style (16th Edition):

Ahmed, Sheikh. “PMU based PSS and SVC fuzzy controller design for angular stability analysis.” 2015. Masters Thesis, Kansas State University. Accessed April 17, 2021. http://hdl.handle.net/2097/20547.

MLA Handbook (7th Edition):

Ahmed, Sheikh. “PMU based PSS and SVC fuzzy controller design for angular stability analysis.” 2015. Web. 17 Apr 2021.

Vancouver:

Ahmed S. PMU based PSS and SVC fuzzy controller design for angular stability analysis. [Internet] [Masters thesis]. Kansas State University; 2015. [cited 2021 Apr 17]. Available from: http://hdl.handle.net/2097/20547.

Council of Science Editors:

Ahmed S. PMU based PSS and SVC fuzzy controller design for angular stability analysis. [Masters Thesis]. Kansas State University; 2015. Available from: http://hdl.handle.net/2097/20547


University of Kentucky

24. Fan, Wen. ADVANCED FAULT AREA IDENTIFICATION AND FAULT LOCATION FOR TRANSMISSION AND DISTRIBUTION SYSTEMS.

Degree: 2019, University of Kentucky

 Fault location reveals the exact information needed for utility crews to timely and promptly perform maintenance and system restoration. Therefore, accurate fault location is a… (more)

Subjects/Keywords: Fault location; simultaneous faults; fault area identification; power systems; distributed generations; phasor measurement units; Power and Energy

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Fan, W. (2019). ADVANCED FAULT AREA IDENTIFICATION AND FAULT LOCATION FOR TRANSMISSION AND DISTRIBUTION SYSTEMS. (Doctoral Dissertation). University of Kentucky. Retrieved from https://uknowledge.uky.edu/ece_etds/144

Chicago Manual of Style (16th Edition):

Fan, Wen. “ADVANCED FAULT AREA IDENTIFICATION AND FAULT LOCATION FOR TRANSMISSION AND DISTRIBUTION SYSTEMS.” 2019. Doctoral Dissertation, University of Kentucky. Accessed April 17, 2021. https://uknowledge.uky.edu/ece_etds/144.

MLA Handbook (7th Edition):

Fan, Wen. “ADVANCED FAULT AREA IDENTIFICATION AND FAULT LOCATION FOR TRANSMISSION AND DISTRIBUTION SYSTEMS.” 2019. Web. 17 Apr 2021.

Vancouver:

Fan W. ADVANCED FAULT AREA IDENTIFICATION AND FAULT LOCATION FOR TRANSMISSION AND DISTRIBUTION SYSTEMS. [Internet] [Doctoral dissertation]. University of Kentucky; 2019. [cited 2021 Apr 17]. Available from: https://uknowledge.uky.edu/ece_etds/144.

Council of Science Editors:

Fan W. ADVANCED FAULT AREA IDENTIFICATION AND FAULT LOCATION FOR TRANSMISSION AND DISTRIBUTION SYSTEMS. [Doctoral Dissertation]. University of Kentucky; 2019. Available from: https://uknowledge.uky.edu/ece_etds/144

25. Oubrahim, Zakarya. On electric grid power quality monitoring using parametric signal processing techniques : Contribution à la surveillance de la qualité de l'énergie du réseau électrique à l'aide de techniques paramétriques de traitement du signal.

Degree: Docteur es, Génie électrique, 2017, Brest

Cette thèse porte sur la surveillance des perturbations de la qualité de l’énergie d’un réseau électrique via des techniques paramétriques de traitement du signal. Pour… (more)

Subjects/Keywords: Réseau électrique; Qualité de l’énergie; Surveillance; Perturbations; Creux de tension et surtensions; Estimation de la fréquence et du phaseur; Phasor Measurement Units (PMUs); IEEE C37.118.2014; Classification; Composantes symétriques; Système électrique déséquilibré; Electric grid; Power quality; Monitoring; Disturbances; Voltage sags and swells; Frequency and phasor estimations; Phasor measurement units (PMUs); IEEE C37.118.2014; Classification; Symmetrical components; Unbalanced power system; 621.31

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Oubrahim, Z. (2017). On electric grid power quality monitoring using parametric signal processing techniques : Contribution à la surveillance de la qualité de l'énergie du réseau électrique à l'aide de techniques paramétriques de traitement du signal. (Doctoral Dissertation). Brest. Retrieved from http://www.theses.fr/2017BRES0102

Chicago Manual of Style (16th Edition):

Oubrahim, Zakarya. “On electric grid power quality monitoring using parametric signal processing techniques : Contribution à la surveillance de la qualité de l'énergie du réseau électrique à l'aide de techniques paramétriques de traitement du signal.” 2017. Doctoral Dissertation, Brest. Accessed April 17, 2021. http://www.theses.fr/2017BRES0102.

MLA Handbook (7th Edition):

Oubrahim, Zakarya. “On electric grid power quality monitoring using parametric signal processing techniques : Contribution à la surveillance de la qualité de l'énergie du réseau électrique à l'aide de techniques paramétriques de traitement du signal.” 2017. Web. 17 Apr 2021.

Vancouver:

Oubrahim Z. On electric grid power quality monitoring using parametric signal processing techniques : Contribution à la surveillance de la qualité de l'énergie du réseau électrique à l'aide de techniques paramétriques de traitement du signal. [Internet] [Doctoral dissertation]. Brest; 2017. [cited 2021 Apr 17]. Available from: http://www.theses.fr/2017BRES0102.

Council of Science Editors:

Oubrahim Z. On electric grid power quality monitoring using parametric signal processing techniques : Contribution à la surveillance de la qualité de l'énergie du réseau électrique à l'aide de techniques paramétriques de traitement du signal. [Doctoral Dissertation]. Brest; 2017. Available from: http://www.theses.fr/2017BRES0102

26. Pal, Anamitra. PMU-Based Applications for Improved Monitoring and Protection of Power Systems.

Degree: PhD, Electrical Engineering, 2014, Virginia Tech

 Monitoring and protection of power systems is a task that has manifold objectives. Amongst others, it involves performing data mining, optimizing available resources, assessing system… (more)

Subjects/Keywords: Binary Integer Programming; Data Conditioning; Fisher Linear Discriminant (FLD); Kalman Filter; Observability; Phasor Measurement Units (PMUs); Stress Assessment; Wide Area Measurement Systems (WAMS)

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Pal, A. (2014). PMU-Based Applications for Improved Monitoring and Protection of Power Systems. (Doctoral Dissertation). Virginia Tech. Retrieved from http://hdl.handle.net/10919/51093

Chicago Manual of Style (16th Edition):

Pal, Anamitra. “PMU-Based Applications for Improved Monitoring and Protection of Power Systems.” 2014. Doctoral Dissertation, Virginia Tech. Accessed April 17, 2021. http://hdl.handle.net/10919/51093.

MLA Handbook (7th Edition):

Pal, Anamitra. “PMU-Based Applications for Improved Monitoring and Protection of Power Systems.” 2014. Web. 17 Apr 2021.

Vancouver:

Pal A. PMU-Based Applications for Improved Monitoring and Protection of Power Systems. [Internet] [Doctoral dissertation]. Virginia Tech; 2014. [cited 2021 Apr 17]. Available from: http://hdl.handle.net/10919/51093.

Council of Science Editors:

Pal A. PMU-Based Applications for Improved Monitoring and Protection of Power Systems. [Doctoral Dissertation]. Virginia Tech; 2014. Available from: http://hdl.handle.net/10919/51093


Queensland University of Technology

27. Goldoost Soloot, Reza. Wide-area damping control through inverse filtering technique.

Degree: 2016, Queensland University of Technology

 This thesis proposes a new wide-area controller for enhancing the stability of power systems by damping inter-area oscillations. The obtained controller is a new nonlinear… (more)

Subjects/Keywords: Inter-area Oscillations; Wide-area Control; Inverse Filtering Technique; Power System Stability; Excitation System Control; Power System Dynamics; Load Modulation; Static Var Compensator; Induction Motor Control; Phasor Measurement Units

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Goldoost Soloot, R. (2016). Wide-area damping control through inverse filtering technique. (Thesis). Queensland University of Technology. Retrieved from http://eprints.qut.edu.au/95937/

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Goldoost Soloot, Reza. “Wide-area damping control through inverse filtering technique.” 2016. Thesis, Queensland University of Technology. Accessed April 17, 2021. http://eprints.qut.edu.au/95937/.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Goldoost Soloot, Reza. “Wide-area damping control through inverse filtering technique.” 2016. Web. 17 Apr 2021.

Vancouver:

Goldoost Soloot R. Wide-area damping control through inverse filtering technique. [Internet] [Thesis]. Queensland University of Technology; 2016. [cited 2021 Apr 17]. Available from: http://eprints.qut.edu.au/95937/.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Goldoost Soloot R. Wide-area damping control through inverse filtering technique. [Thesis]. Queensland University of Technology; 2016. Available from: http://eprints.qut.edu.au/95937/

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Queensland University of Technology

28. Vahidnia, Arash. Wide area control through aggregation of power systems.

Degree: 2013, Queensland University of Technology

 This thesis was a step forward in improving the stability of power systems by applying new control and modelling techniques. The developed methods use the… (more)

Subjects/Keywords: Aggregation of Power Systems; Dynamic Reduction; FACTS Devices; Generator Coherency; Inter-area Oscillations; Kalman Filter; Phasor Measurement Units; Power System Stability; State Estimation; Wide-area Control

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Vahidnia, A. (2013). Wide area control through aggregation of power systems. (Thesis). Queensland University of Technology. Retrieved from https://eprints.qut.edu.au/61186/

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Vahidnia, Arash. “Wide area control through aggregation of power systems.” 2013. Thesis, Queensland University of Technology. Accessed April 17, 2021. https://eprints.qut.edu.au/61186/.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Vahidnia, Arash. “Wide area control through aggregation of power systems.” 2013. Web. 17 Apr 2021.

Vancouver:

Vahidnia A. Wide area control through aggregation of power systems. [Internet] [Thesis]. Queensland University of Technology; 2013. [cited 2021 Apr 17]. Available from: https://eprints.qut.edu.au/61186/.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Vahidnia A. Wide area control through aggregation of power systems. [Thesis]. Queensland University of Technology; 2013. Available from: https://eprints.qut.edu.au/61186/

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

29. Ekechukwu, Chinedum. Improving Low Voltage Ride-Through Requirements (LVRT) Based on Hybrid PMU, Conventional Measurements in Wind Power Systems.

Degree: Physics and Electrical Engineering, 2014, Karlstad University

  Previously, conventional state estimation techniques have been used for state estimation in power systems. These conventional methods are based on steady state models. As… (more)

Subjects/Keywords: State Estimation; Power Systems; Unscented Kalman Filters; Phasor Measurement Units

…real-time measurement from remote terminal units (RTUs) and phasor data… …to the SCADA system. Fig 3.4: Hierarchical placement of phasor measurement units. Let us… …Measuring devices such as Phasor Measuring Units (PMUs), which were developed in the… …measurement noise vector with covariance matrix ∁௡ ∈ ℝ௅ ௫ ௅ . 3.2 Synchronized Phasor… …Measurements Units (PMUs) PMUs are measurement devices capable of providing near real-time… 

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Ekechukwu, C. (2014). Improving Low Voltage Ride-Through Requirements (LVRT) Based on Hybrid PMU, Conventional Measurements in Wind Power Systems. (Thesis). Karlstad University. Retrieved from http://urn.kb.se/resolve?urn=urn:nbn:se:kau:diva-31449

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Ekechukwu, Chinedum. “Improving Low Voltage Ride-Through Requirements (LVRT) Based on Hybrid PMU, Conventional Measurements in Wind Power Systems.” 2014. Thesis, Karlstad University. Accessed April 17, 2021. http://urn.kb.se/resolve?urn=urn:nbn:se:kau:diva-31449.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Ekechukwu, Chinedum. “Improving Low Voltage Ride-Through Requirements (LVRT) Based on Hybrid PMU, Conventional Measurements in Wind Power Systems.” 2014. Web. 17 Apr 2021.

Vancouver:

Ekechukwu C. Improving Low Voltage Ride-Through Requirements (LVRT) Based on Hybrid PMU, Conventional Measurements in Wind Power Systems. [Internet] [Thesis]. Karlstad University; 2014. [cited 2021 Apr 17]. Available from: http://urn.kb.se/resolve?urn=urn:nbn:se:kau:diva-31449.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Ekechukwu C. Improving Low Voltage Ride-Through Requirements (LVRT) Based on Hybrid PMU, Conventional Measurements in Wind Power Systems. [Thesis]. Karlstad University; 2014. Available from: http://urn.kb.se/resolve?urn=urn:nbn:se:kau:diva-31449

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

30. Frazao, Rodrigo José Albuquerque. PMU based situation awareness for smart distribution grids : Unités de mesure de phaseur dans le cadre des réseaux de distribution électrique intelligents.

Degree: Docteur es, Génie électrique, 2015, Université Grenoble Alpes (ComUE)

 Une infrastructure robuste de surveillance basée sur des mesures numériques classiques est souvent utilisée pour permettre une gestion efficace du réseau de distribution électrique, néanmoins… (more)

Subjects/Keywords: Synchrophaseur; Unités de mesure de phaseur; Réseaux de distribution électrique intelligent; Algorithmes adaptifs en fréquence; Applications; Synchrophasor; Phasor measurement units; Active power distribution systems; Frequency adaptive algorithms; Applications; 620

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Frazao, R. J. A. (2015). PMU based situation awareness for smart distribution grids : Unités de mesure de phaseur dans le cadre des réseaux de distribution électrique intelligents. (Doctoral Dissertation). Université Grenoble Alpes (ComUE). Retrieved from http://www.theses.fr/2015GREAT061

Chicago Manual of Style (16th Edition):

Frazao, Rodrigo José Albuquerque. “PMU based situation awareness for smart distribution grids : Unités de mesure de phaseur dans le cadre des réseaux de distribution électrique intelligents.” 2015. Doctoral Dissertation, Université Grenoble Alpes (ComUE). Accessed April 17, 2021. http://www.theses.fr/2015GREAT061.

MLA Handbook (7th Edition):

Frazao, Rodrigo José Albuquerque. “PMU based situation awareness for smart distribution grids : Unités de mesure de phaseur dans le cadre des réseaux de distribution électrique intelligents.” 2015. Web. 17 Apr 2021.

Vancouver:

Frazao RJA. PMU based situation awareness for smart distribution grids : Unités de mesure de phaseur dans le cadre des réseaux de distribution électrique intelligents. [Internet] [Doctoral dissertation]. Université Grenoble Alpes (ComUE); 2015. [cited 2021 Apr 17]. Available from: http://www.theses.fr/2015GREAT061.

Council of Science Editors:

Frazao RJA. PMU based situation awareness for smart distribution grids : Unités de mesure de phaseur dans le cadre des réseaux de distribution électrique intelligents. [Doctoral Dissertation]. Université Grenoble Alpes (ComUE); 2015. Available from: http://www.theses.fr/2015GREAT061

[1] [2]

.