You searched for subject:(Orthodontic Wires)
.
Showing records 1 – 30 of
40 total matches.
◁ [1] [2] ▶
1.
Lohse, John F.
A method for evaluating multiple strand orthodontic wires.
Degree: Certificate in Orthodontics, Orthodontics, 1974, Oregon Health Sciences University
URL: doi:10.6083/M4XD0ZWK
;
http://digitalcommons.ohsu.edu/etd/2516
Subjects/Keywords: Orthodontic Wires
Record Details
Similar Records
Cite
Share »
Record Details
Similar Records
Cite
« Share





❌
APA ·
Chicago ·
MLA ·
Vancouver ·
CSE |
Export
to Zotero / EndNote / Reference
Manager
APA (6th Edition):
Lohse, J. F. (1974). A method for evaluating multiple strand orthodontic wires. (Thesis). Oregon Health Sciences University. Retrieved from doi:10.6083/M4XD0ZWK ; http://digitalcommons.ohsu.edu/etd/2516
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
Chicago Manual of Style (16th Edition):
Lohse, John F. “A method for evaluating multiple strand orthodontic wires.” 1974. Thesis, Oregon Health Sciences University. Accessed April 19, 2021.
doi:10.6083/M4XD0ZWK ; http://digitalcommons.ohsu.edu/etd/2516.
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
MLA Handbook (7th Edition):
Lohse, John F. “A method for evaluating multiple strand orthodontic wires.” 1974. Web. 19 Apr 2021.
Vancouver:
Lohse JF. A method for evaluating multiple strand orthodontic wires. [Internet] [Thesis]. Oregon Health Sciences University; 1974. [cited 2021 Apr 19].
Available from: doi:10.6083/M4XD0ZWK ; http://digitalcommons.ohsu.edu/etd/2516.
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
Council of Science Editors:
Lohse JF. A method for evaluating multiple strand orthodontic wires. [Thesis]. Oregon Health Sciences University; 1974. Available from: doi:10.6083/M4XD0ZWK ; http://digitalcommons.ohsu.edu/etd/2516
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Loma Linda University
2.
Wierenga, Mark.
Copper, Aluminum and Nickel: A New Monocrystalline Orthodontic Alloy.
Degree: MSODO, Orthodontics and Dentofacial Orthopedics, 2014, Loma Linda University
URL: https://scholarsrepository.llu.edu/etd/195
► Introduction: This study was designed to evaluate, via tensile and bend testing, the mechanical properties of a newly-developed monocrystalline orthodontic archwire comprised of a…
(more)
▼ Introduction: This study was designed to evaluate, via tensile and bend testing, the mechanical properties of a newly-developed monocrystalline
orthodontic archwire comprised of a blend of copper, aluminum, and nickel (CuAlNi). Methods: The sample was comprised of three shape memory alloys; CuAlNi, copper nickel titanium (CuNiTi), and nickel titanium (NiTi); from various
orthodontic manufacturers in both 0.018” round and 0.019” x 0.025” rectangular dimensions. Additional data was gathered for similarly sized stainless steel and beta-titanium archwires as a point of reference for drawing conclusions about the relative properties of the archwires. Measurements of loading and unloading forces were recorded in both tension and deflection testing. Repeated-measure ANOVA (α= 0.05) was used to compare loading and unloading forces across
wires and one-way ANOVA (α= 0.05) was used to compare elastic moduli and hysteresis. To identify significant differences, Tukey post-hoc comparisons were performed. Results: The modulus of elasticity, deflection forces, and hysteresis profiles of CuAlNi were significantly different than the other superelastic
wires tested. In all tests, CuAlNi had a statistically significant lower modulus of elasticity compared to the CuNiTi and NiTi
wires (
P <0.0001). The CuAlNi wire exhibited significantly lower loading and unloading forces than any other wire tested. In round wire tensile tests, loading force at all deflections was significantly lower for CuAlNi than CuNiTi or NiTi (
P <0.0001). In tensile testing, the CuAlNi alloy was able to recover from a 7 mm extension (10% elongation) without permanent deformation and with little to no loss in force output. In large-deflection bend tests at 4, 5, and 6 mm deflection, CuAlNi showed the significantly lowest loading forces across the three wire materials (
P <0.0001). The NiTi
wires showed up to 12 times the amount of energy loss due to hysteresis compared to CuAlNi. CuAlNi showed a hysteresis loss that was significantly less than any other wire tested in this study (
P <0.0001). Conclusions: The relatively constant force delivered for a long period of time during the deactivation of this wire, the minimal hysteresis loss, the low force output in deflection, and the relatively low modulus of elasticity suggest that CuAlNi
wires should be considered an important material addition to
orthodontic metallurgy.
Advisors/Committee Members: Leggitt, V. Leroy, Olson, Gregory, Rungcharassaeng, Kitichai.
Subjects/Keywords: Dentistry; Orthodontics and Orthodontology; Orthodontic Wires; Orthodontic alloys; Monocrystalline orthodontic alloys; tensile strength; archwires
Record Details
Similar Records
Cite
Share »
Record Details
Similar Records
Cite
« Share





❌
APA ·
Chicago ·
MLA ·
Vancouver ·
CSE |
Export
to Zotero / EndNote / Reference
Manager
APA (6th Edition):
Wierenga, M. (2014). Copper, Aluminum and Nickel: A New Monocrystalline Orthodontic Alloy. (Thesis). Loma Linda University. Retrieved from https://scholarsrepository.llu.edu/etd/195
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
Chicago Manual of Style (16th Edition):
Wierenga, Mark. “Copper, Aluminum and Nickel: A New Monocrystalline Orthodontic Alloy.” 2014. Thesis, Loma Linda University. Accessed April 19, 2021.
https://scholarsrepository.llu.edu/etd/195.
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
MLA Handbook (7th Edition):
Wierenga, Mark. “Copper, Aluminum and Nickel: A New Monocrystalline Orthodontic Alloy.” 2014. Web. 19 Apr 2021.
Vancouver:
Wierenga M. Copper, Aluminum and Nickel: A New Monocrystalline Orthodontic Alloy. [Internet] [Thesis]. Loma Linda University; 2014. [cited 2021 Apr 19].
Available from: https://scholarsrepository.llu.edu/etd/195.
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
Council of Science Editors:
Wierenga M. Copper, Aluminum and Nickel: A New Monocrystalline Orthodontic Alloy. [Thesis]. Loma Linda University; 2014. Available from: https://scholarsrepository.llu.edu/etd/195
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

University of Missouri – Kansas City
3.
Sander, Kristen.
The Effect of Topical Fluoride Agents on Coated Nickel-Titanium Archwires.
Degree: 2015, University of Missouri – Kansas City
URL: http://hdl.handle.net/10355/48037
► This study examined the effect of exposure to topical fluoride agents on the mechanical properties and surface characteristics of esthetic coated nickel-titanium archwires. Two types…
(more)
▼ This study examined the effect of exposure to topical fluoride agents on the mechanical properties and surface characteristics of esthetic coated nickel-titanium archwires. Two types of coated
wires were tested: one with a polymer coating and one with a rhodium ion coating.
Wires were divided into treatment groups based on type of fluoride exposure: no treatment (DI water), neutral sodium fluoride gel, neutral sodium fluoride rinse, or acidulated phosphate fluoride (APF) gel. A three-point bend test in DI water at 37±1°C was performed on specimens before and after test solution exposure. Unloading forces at 1, 1.5, and 2mm of deflection were reported, along with unloading elastic modulus and yield strength. Three representative specimens from each treatment group along with untested
wires underwent qualitative scanning electron microscopy (SEM) surface topography analysis following test solution exposure.
Results of the present study indicated no significant difference between treatment groups for any mechanical properties measured (p > 0.05) after fluoride exposure. However, significant differences were observed between wire types for all measures within all treatment groups (p < 0.05). Rhodium-coated
wires exhibited significantly lower unloading forces, lower yield strength, and higher elastic modulus than polymer-coated
wires. This may
be due to effects of the coatings or due to differences in the underlying nickel-titanium. SEM analysis revealed the polymer coating peeled off in areas of contact with testing apparatus. With polymer-coated
wires, exposed underlying nickel-titanium exhibited pitting corrosion after APF gel treatment, which did not occur with other fluoride groups or the DI water group. Similarly, with rhodium-coated
wires exposed to APF gel, corrosion pitting appeared to go through the rhodium coating into the underlying NiTi wire, which did not occur with other fluoride groups or the DI water group.
The lack of degradation of mechanical properties of
wires exposed to fluoride in this study suggests a potential protective effect of coatings on nickel-titanium. However, polymer coating instability could pose a problem by allowing underlying nickel-titanium to come into contact with fluoride when used in the mouth. Further research is needed to determine whether this protective effect continues even after substantial coating degradation.
Advisors/Committee Members: Walker, Mary P. (advisor), Nickel, Jeffrey C. (Jeffrey Charles), 1957- (advisor).
Subjects/Keywords: Orthodontic appliances; Fluorides; Orthodontic Wires; Fluorides, Topical; Thesis – University of Missouri – Kansas City – Dentistry
Record Details
Similar Records
Cite
Share »
Record Details
Similar Records
Cite
« Share





❌
APA ·
Chicago ·
MLA ·
Vancouver ·
CSE |
Export
to Zotero / EndNote / Reference
Manager
APA (6th Edition):
Sander, K. (2015). The Effect of Topical Fluoride Agents on Coated Nickel-Titanium Archwires. (Thesis). University of Missouri – Kansas City. Retrieved from http://hdl.handle.net/10355/48037
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
Chicago Manual of Style (16th Edition):
Sander, Kristen. “The Effect of Topical Fluoride Agents on Coated Nickel-Titanium Archwires.” 2015. Thesis, University of Missouri – Kansas City. Accessed April 19, 2021.
http://hdl.handle.net/10355/48037.
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
MLA Handbook (7th Edition):
Sander, Kristen. “The Effect of Topical Fluoride Agents on Coated Nickel-Titanium Archwires.” 2015. Web. 19 Apr 2021.
Vancouver:
Sander K. The Effect of Topical Fluoride Agents on Coated Nickel-Titanium Archwires. [Internet] [Thesis]. University of Missouri – Kansas City; 2015. [cited 2021 Apr 19].
Available from: http://hdl.handle.net/10355/48037.
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
Council of Science Editors:
Sander K. The Effect of Topical Fluoride Agents on Coated Nickel-Titanium Archwires. [Thesis]. University of Missouri – Kansas City; 2015. Available from: http://hdl.handle.net/10355/48037
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
4.
Dowe, Frederick L.
Ligature tie friction in the 22 mil edgewise appliance.
Degree: Certificate in Orthodontics, Orthodontics, 1975, Oregon Health Sciences University
URL: doi:10.6083/M4DJ5CVQ
;
http://digitalcommons.ohsu.edu/etd/2489
Subjects/Keywords: Ligation; Orthodontic Wires; Friction
Record Details
Similar Records
Cite
Share »
Record Details
Similar Records
Cite
« Share





❌
APA ·
Chicago ·
MLA ·
Vancouver ·
CSE |
Export
to Zotero / EndNote / Reference
Manager
APA (6th Edition):
Dowe, F. L. (1975). Ligature tie friction in the 22 mil edgewise appliance. (Thesis). Oregon Health Sciences University. Retrieved from doi:10.6083/M4DJ5CVQ ; http://digitalcommons.ohsu.edu/etd/2489
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
Chicago Manual of Style (16th Edition):
Dowe, Frederick L. “Ligature tie friction in the 22 mil edgewise appliance.” 1975. Thesis, Oregon Health Sciences University. Accessed April 19, 2021.
doi:10.6083/M4DJ5CVQ ; http://digitalcommons.ohsu.edu/etd/2489.
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
MLA Handbook (7th Edition):
Dowe, Frederick L. “Ligature tie friction in the 22 mil edgewise appliance.” 1975. Web. 19 Apr 2021.
Vancouver:
Dowe FL. Ligature tie friction in the 22 mil edgewise appliance. [Internet] [Thesis]. Oregon Health Sciences University; 1975. [cited 2021 Apr 19].
Available from: doi:10.6083/M4DJ5CVQ ; http://digitalcommons.ohsu.edu/etd/2489.
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
Council of Science Editors:
Dowe FL. Ligature tie friction in the 22 mil edgewise appliance. [Thesis]. Oregon Health Sciences University; 1975. Available from: doi:10.6083/M4DJ5CVQ ; http://digitalcommons.ohsu.edu/etd/2489
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
5.
Ecker, John M.
A force comparison study of round orthodontic wires.
Degree: Certificate in Orthodontics, Orthodontics, 1975, Oregon Health Sciences University
URL: doi:10.6083/M4J964MW
;
http://digitalcommons.ohsu.edu/etd/2488
Subjects/Keywords: Orthodontic Wires; Tooth Movement
Record Details
Similar Records
Cite
Share »
Record Details
Similar Records
Cite
« Share





❌
APA ·
Chicago ·
MLA ·
Vancouver ·
CSE |
Export
to Zotero / EndNote / Reference
Manager
APA (6th Edition):
Ecker, J. M. (1975). A force comparison study of round orthodontic wires. (Thesis). Oregon Health Sciences University. Retrieved from doi:10.6083/M4J964MW ; http://digitalcommons.ohsu.edu/etd/2488
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
Chicago Manual of Style (16th Edition):
Ecker, John M. “A force comparison study of round orthodontic wires.” 1975. Thesis, Oregon Health Sciences University. Accessed April 19, 2021.
doi:10.6083/M4J964MW ; http://digitalcommons.ohsu.edu/etd/2488.
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
MLA Handbook (7th Edition):
Ecker, John M. “A force comparison study of round orthodontic wires.” 1975. Web. 19 Apr 2021.
Vancouver:
Ecker JM. A force comparison study of round orthodontic wires. [Internet] [Thesis]. Oregon Health Sciences University; 1975. [cited 2021 Apr 19].
Available from: doi:10.6083/M4J964MW ; http://digitalcommons.ohsu.edu/etd/2488.
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
Council of Science Editors:
Ecker JM. A force comparison study of round orthodontic wires. [Thesis]. Oregon Health Sciences University; 1975. Available from: doi:10.6083/M4J964MW ; http://digitalcommons.ohsu.edu/etd/2488
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

University of Toronto
6.
Oguienko, Ouliana.
Mechanical Properties of Graded Thermodynamic Nickel Titanium Archwires in Bending and Torsion.
Degree: 2017, University of Toronto
URL: http://hdl.handle.net/1807/80228
► Background: Graded thermodynamic nickel titanium (GT-NiTi) wires purportedly deliver differential force levels in different archwire regions. No studies evaluating the force delivery characteristics of such…
(more)
▼ Background: Graded thermodynamic nickel titanium (GT-NiTi) wires purportedly deliver differential force levels in different archwire regions. No studies evaluating the force delivery characteristics of such wires currently exist. Objective: To evaluate the mechanical properties of GT-NiTi wires in bending and torsion. Methods: Six samples of 0.016 x 0.022â and 0.017 x 0.025â of GT-NiTi wires were divided into incisor, premolar, and molar sections and each segment was tested in bending and torsion. The characteristics of the unloading superelastic plateau were evaluated and compared with similar segments of non-graded, control NiTi wires. Results: Statistically significant differences in mean force and moment levels were found between the three sections of GT-NiTi wires, but not in control wires. Small but statistically significant differences in length and slope were also found. Conclusion: GT-NiTi wires deliver different forces and moments in different archwire sections. Clinicians can use this knowledge to optimize force delivery for treatment.
M.Sc.
Advisors/Committee Members: Suri, Sunjay, Dentistry.
Subjects/Keywords: nickel titanium; orthodontic wires; three-point bending; torsion; 0567
Record Details
Similar Records
Cite
Share »
Record Details
Similar Records
Cite
« Share





❌
APA ·
Chicago ·
MLA ·
Vancouver ·
CSE |
Export
to Zotero / EndNote / Reference
Manager
APA (6th Edition):
Oguienko, O. (2017). Mechanical Properties of Graded Thermodynamic Nickel Titanium Archwires in Bending and Torsion. (Masters Thesis). University of Toronto. Retrieved from http://hdl.handle.net/1807/80228
Chicago Manual of Style (16th Edition):
Oguienko, Ouliana. “Mechanical Properties of Graded Thermodynamic Nickel Titanium Archwires in Bending and Torsion.” 2017. Masters Thesis, University of Toronto. Accessed April 19, 2021.
http://hdl.handle.net/1807/80228.
MLA Handbook (7th Edition):
Oguienko, Ouliana. “Mechanical Properties of Graded Thermodynamic Nickel Titanium Archwires in Bending and Torsion.” 2017. Web. 19 Apr 2021.
Vancouver:
Oguienko O. Mechanical Properties of Graded Thermodynamic Nickel Titanium Archwires in Bending and Torsion. [Internet] [Masters thesis]. University of Toronto; 2017. [cited 2021 Apr 19].
Available from: http://hdl.handle.net/1807/80228.
Council of Science Editors:
Oguienko O. Mechanical Properties of Graded Thermodynamic Nickel Titanium Archwires in Bending and Torsion. [Masters Thesis]. University of Toronto; 2017. Available from: http://hdl.handle.net/1807/80228
7.
Lopes, Rúbia Lorena Siqueira Garcia.
Citotoxicidade de fios ortodônticos de níquel - titânio superelásticos e termoativado.
Degree: 2015, Universidade Federal de Goiás; Programa de Pós-graduação em Odontologia (FO); UFG; Brasil; Faculdade de Odontologia – FO (RG)
URL: http://repositorio.bc.ufg.br/tede/handle/tede/9857
► Submitted by Franciele Moreira ([email protected]) on 2019-07-31T15:55:31Z No. of bitstreams: 2 Dissertação - Rúbia Lorena Siqueira Garcia Lopes - 2015.pdf: 1028508 bytes, checksum: 232b7cce16eb3c930555e553d4be8724 (MD5)…
(more)
▼ Submitted by Franciele Moreira ([email protected]) on 2019-07-31T15:55:31Z No. of bitstreams: 2 Dissertação - Rúbia Lorena Siqueira Garcia Lopes - 2015.pdf: 1028508 bytes, checksum: 232b7cce16eb3c930555e553d4be8724 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Approved for entry into archive by Luciana Ferreira ([email protected]) on 2019-08-02T11:17:02Z (GMT) No. of bitstreams: 2 Dissertação - Rúbia Lorena Siqueira Garcia Lopes - 2015.pdf: 1028508 bytes, checksum: 232b7cce16eb3c930555e553d4be8724 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Made available in DSpace on 2019-08-02T11:17:02Z (GMT). No. of bitstreams: 2 Dissertação - Rúbia Lorena Siqueira Garcia Lopes - 2015.pdf: 1028508 bytes, checksum: 232b7cce16eb3c930555e553d4be8724 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2015-03-03
Coordenação de
Aperfeiçoamento de Pessoal de Nível Superior - CAPES
Introduction: the use of wires or any other orthodontic appliance that contains nickel can sensitize an individual not previously sensitive. Nickel titanium wires (NiTi) are used during many stages of orthodontic treatment, staying for a considerable time in contact with the mucous and saliva. Purpose: To assess "in vitro" fibroblast cell viability in relation to nickel present in cytotoxicity superelastic nickel-titanium wire and termoativado. Materials and Methods: The study "in vitro" used strains of murine fibroblasts commercially available in order to evaluate the cytotoxicity of NiTi wires 0014 '. L929 cells were cultured, exposed to extracts from immersion of the wires in artificial saliva for 30 to 60 days. The sample consisted of four commercial brands: Morelli, Orthometric, GAC and Abzil three types of alloys: stainless steel, superelastic NiTi and NiTi termoativado. All wires were sterilized in an autoclave, according
to the manufacturer's instructions. Tests were performed to verify the release of nickel ions in the artificial saliva, atomic absorption spectrophotometry (AAS). The Scanning Electron Microscopy (SEM) to analyze the surface morphology. Elemental analysis of the surface of the wire by Energy Dispersive Spectroscopy (EDS). And cell viability testing, to test the cytotoxicity of nickel through the cell culture extracts. The two-way ANOVA test was used to evaluate the interaction of wire marks and alloys and the t- test was used to compare the times of 30 and 60 days with p <0.05. Results: In the EAA there was the release of nickel ions, with statistically significant differences between the brands and types of alloys in the time of 60 days. In SEM of the wires was not observed morphological differences between samples and their controls. There was no cytotoxicity when cultures were exposed to the sample extracts.
Introdução: O uso dos fios ou qualquer outro dispositivo
ortodôntico que contenha níquel pode sensibilizar um indivíduo até então não sensível. Os fios de níquel…
Advisors/Committee Members: Lenza, Marcos Augusto, Silva, Fernanda Paula Yamamoto, Lenza, Marcos Augusto, Gomes, Thaisângela Rodrigues Lopes e Silva, Nery, Claudio de Gois.
Subjects/Keywords: Citotoxicidade; Níquel; Fios ortodônticos; Cytotoxicity; Nickel; Orthodontic wires; ODONTOLOGIA::CLINICA ODONTOLOGICA
Record Details
Similar Records
Cite
Share »
Record Details
Similar Records
Cite
« Share





❌
APA ·
Chicago ·
MLA ·
Vancouver ·
CSE |
Export
to Zotero / EndNote / Reference
Manager
APA (6th Edition):
Lopes, R. L. S. G. (2015). Citotoxicidade de fios ortodônticos de níquel - titânio superelásticos e termoativado. (Masters Thesis). Universidade Federal de Goiás; Programa de Pós-graduação em Odontologia (FO); UFG; Brasil; Faculdade de Odontologia – FO (RG). Retrieved from http://repositorio.bc.ufg.br/tede/handle/tede/9857
Chicago Manual of Style (16th Edition):
Lopes, Rúbia Lorena Siqueira Garcia. “Citotoxicidade de fios ortodônticos de níquel - titânio superelásticos e termoativado.” 2015. Masters Thesis, Universidade Federal de Goiás; Programa de Pós-graduação em Odontologia (FO); UFG; Brasil; Faculdade de Odontologia – FO (RG). Accessed April 19, 2021.
http://repositorio.bc.ufg.br/tede/handle/tede/9857.
MLA Handbook (7th Edition):
Lopes, Rúbia Lorena Siqueira Garcia. “Citotoxicidade de fios ortodônticos de níquel - titânio superelásticos e termoativado.” 2015. Web. 19 Apr 2021.
Vancouver:
Lopes RLSG. Citotoxicidade de fios ortodônticos de níquel - titânio superelásticos e termoativado. [Internet] [Masters thesis]. Universidade Federal de Goiás; Programa de Pós-graduação em Odontologia (FO); UFG; Brasil; Faculdade de Odontologia – FO (RG); 2015. [cited 2021 Apr 19].
Available from: http://repositorio.bc.ufg.br/tede/handle/tede/9857.
Council of Science Editors:
Lopes RLSG. Citotoxicidade de fios ortodônticos de níquel - titânio superelásticos e termoativado. [Masters Thesis]. Universidade Federal de Goiás; Programa de Pós-graduação em Odontologia (FO); UFG; Brasil; Faculdade de Odontologia – FO (RG); 2015. Available from: http://repositorio.bc.ufg.br/tede/handle/tede/9857
8.
Sakima, Cristiane Graciano Ponce [UNESP].
Avaliação das propriedades mecânicas de fios de Níquel-Titânio após incorporação de dobras e/ou tratamento elétrico.
Degree: 2006, Universidade Estadual Paulista (UNESP)
URL: http://hdl.handle.net/11449/95761
► Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-03-27Bitstream added on 2014-06-13T19:36:11Z : No. of bitstreams: 1 sakima_cgp_me_arafo.pdf: 875892…
(more)
▼ Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-03-27Bitstream added on 2014-06-13T19:36:11Z : No. of bitstreams: 1 sakima_cgp_me_arafo.pdf: 875892 bytes, checksum: 0b407b85b7e24386d401869c06430798 (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
A possibilidade de usar fios superelásticos retangulares com níveis de força mais leves (biológicos) permitiria simultâneo alinhamento, nivelamento e torque, o que resultaria em um menor número de fios utilizados, reduzindo custos e tempo de tratamento. Existe uma tendência, principalmente na ortodontia lingual, de se dobrar fios superelásticos (manualmente ou com tratamento térmico/elétrico) para adequar o fio à forma do arco. O objetivo deste trabalho foi avaliar as propriedades mecânicas de fios de NiTi de quatro marcas comerciais diferentes (0,017 x 0,025) após dobras e tratamento elétrico. Os fios foram dobrados com
alicates elétricos (sistema DERHT) e com alicate 139 e depois foram comparados com fios retos sem nenhum tratamento (grupo controle) e fios retos com tratamento elétrico sem dobras (grupo controle tratamento elétrico). Na tentativa de simular uma situação clínica, todos os fios foram testados a 36 °C na máquina de testes FSI (Sistema Identificador de Forças). Foram testados usando-se braquetes autoligáveis tipo Damon, simulando ativações em segunda ordem de 0 mm a 2 mm. Foram analisadas as seguintes variáveis: força e deslocamento no ponto do limite elástico, força máxima, energia total, energia dissipada, energia perdida, força e deslocamento no início e no fim do platô, inclinação e comprimento do platô. As diferenças estatísticas para os diferentes fios, nos diferentes testes, foram avaliadas pela ANOVA. Os resultados mostraram que: (1) o tratamento elétrico afetou as propriedades mecânicas de todos os fios de maneira geral, existindo uma tendência de diminuição nos níveis de
força; (2) quando os fios receberam dobras, todos perderam os platôs de superelasticidade; (3) se o uso de forças leves e constantes é desejável no tratamento ortodôntico, os fios termodinâmicos deveriam ser recomendados na seguinte ordem: Copper NiTi 400, Neo Sentalloy 100 e Copper NiTi 270.
The possibility of using superelastic rectangular Nickel-Titanium wires in early stages of treatment with light forces, could allow more three-dimensional control, a small number of wires, lowering costs and treatment time. There is a tendency, especially in lingual orthodontics of bending superelastic wires (manually or with heat treatment) to adequate the wire in the arch anatomy. The aim of this study was to evaluate the mechanical properties of four commercially available 0.017 x 0.025 inch NiTi archwires after bending and heat treatment. The wires were bent with electrical pliers (DERHT System) and with standard bird beak plier and then compared with straight wires as a control group and
another electrical treatment control group. All the wires were tested at 360 C in an orthodontic wire-testing…
Advisors/Committee Members: Universidade Estadual Paulista (UNESP), Gonçalves, João Roberto [UNESP].
Subjects/Keywords: Fios ortodônticos; Orthodontic wires
Record Details
Similar Records
Cite
Share »
Record Details
Similar Records
Cite
« Share





❌
APA ·
Chicago ·
MLA ·
Vancouver ·
CSE |
Export
to Zotero / EndNote / Reference
Manager
APA (6th Edition):
Sakima, C. G. P. [. (2006). Avaliação das propriedades mecânicas de fios de Níquel-Titânio após incorporação de dobras e/ou tratamento elétrico. (Masters Thesis). Universidade Estadual Paulista (UNESP). Retrieved from http://hdl.handle.net/11449/95761
Chicago Manual of Style (16th Edition):
Sakima, Cristiane Graciano Ponce [UNESP]. “Avaliação das propriedades mecânicas de fios de Níquel-Titânio após incorporação de dobras e/ou tratamento elétrico.” 2006. Masters Thesis, Universidade Estadual Paulista (UNESP). Accessed April 19, 2021.
http://hdl.handle.net/11449/95761.
MLA Handbook (7th Edition):
Sakima, Cristiane Graciano Ponce [UNESP]. “Avaliação das propriedades mecânicas de fios de Níquel-Titânio após incorporação de dobras e/ou tratamento elétrico.” 2006. Web. 19 Apr 2021.
Vancouver:
Sakima CGP[. Avaliação das propriedades mecânicas de fios de Níquel-Titânio após incorporação de dobras e/ou tratamento elétrico. [Internet] [Masters thesis]. Universidade Estadual Paulista (UNESP); 2006. [cited 2021 Apr 19].
Available from: http://hdl.handle.net/11449/95761.
Council of Science Editors:
Sakima CGP[. Avaliação das propriedades mecânicas de fios de Níquel-Titânio após incorporação de dobras e/ou tratamento elétrico. [Masters Thesis]. Universidade Estadual Paulista (UNESP); 2006. Available from: http://hdl.handle.net/11449/95761
9.
Werner, Gregory R.
Atomic layer deposition coatings on orthodontic archwires and brackets : resistance to sliding, coefficient of friction, and mechanical testing.
Degree: MS, 2011, Oregon Health Sciences University
URL: doi:10.6083/M4K9369V
;
http://digitalcommons.ohsu.edu/etd/3688
Subjects/Keywords: Orthodontic Brackets; Orthodontic Wires; Friction; Orthodontics and Orthodontology
Record Details
Similar Records
Cite
Share »
Record Details
Similar Records
Cite
« Share





❌
APA ·
Chicago ·
MLA ·
Vancouver ·
CSE |
Export
to Zotero / EndNote / Reference
Manager
APA (6th Edition):
Werner, G. R. (2011). Atomic layer deposition coatings on orthodontic archwires and brackets : resistance to sliding, coefficient of friction, and mechanical testing. (Thesis). Oregon Health Sciences University. Retrieved from doi:10.6083/M4K9369V ; http://digitalcommons.ohsu.edu/etd/3688
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
Chicago Manual of Style (16th Edition):
Werner, Gregory R. “Atomic layer deposition coatings on orthodontic archwires and brackets : resistance to sliding, coefficient of friction, and mechanical testing.” 2011. Thesis, Oregon Health Sciences University. Accessed April 19, 2021.
doi:10.6083/M4K9369V ; http://digitalcommons.ohsu.edu/etd/3688.
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
MLA Handbook (7th Edition):
Werner, Gregory R. “Atomic layer deposition coatings on orthodontic archwires and brackets : resistance to sliding, coefficient of friction, and mechanical testing.” 2011. Web. 19 Apr 2021.
Vancouver:
Werner GR. Atomic layer deposition coatings on orthodontic archwires and brackets : resistance to sliding, coefficient of friction, and mechanical testing. [Internet] [Thesis]. Oregon Health Sciences University; 2011. [cited 2021 Apr 19].
Available from: doi:10.6083/M4K9369V ; http://digitalcommons.ohsu.edu/etd/3688.
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
Council of Science Editors:
Werner GR. Atomic layer deposition coatings on orthodontic archwires and brackets : resistance to sliding, coefficient of friction, and mechanical testing. [Thesis]. Oregon Health Sciences University; 2011. Available from: doi:10.6083/M4K9369V ; http://digitalcommons.ohsu.edu/etd/3688
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
10.
Ramos, Aretha Aliny dos Santos.
Propriedades físico-químicas de bráquetes e fios ortodônticos utilizados em diferentes tempos de tratamento.
Degree: 2014, Universidade Federal da Paraíba; Programa de Pós-Graduação em Odontologia; UFPB; Brasil; Odontologia
URL: https://repositorio.ufpb.br/jspui/handle/tede/8868
► Submitted by Maike Costa ([email protected]) on 2017-03-16T12:14:26Z No. of bitstreams: 1 arquivototal.pdf: 1679756 bytes, checksum: 5065ecafba4b6ac4c0113ddd5cc81002 (MD5)
Made available in DSpace on 2017-03-16T12:14:26Z (GMT). No.…
(more)
▼ Submitted by Maike Costa ([email protected]) on 2017-03-16T12:14:26Z No. of bitstreams: 1 arquivototal.pdf: 1679756 bytes, checksum: 5065ecafba4b6ac4c0113ddd5cc81002 (MD5)
Made available in DSpace on 2017-03-16T12:14:26Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 1679756 bytes, checksum: 5065ecafba4b6ac4c0113ddd5cc81002 (MD5) Previous issue date: 2014-02-18
Made available in DSpace on 2018-07-21T00:23:50Z (GMT). No. of bitstreams: 2 arquivototal.pdf: 1679756 bytes, checksum: 5065ecafba4b6ac4c0113ddd5cc81002 (MD5) arquivototal.pdf.jpg: 4703 bytes, checksum: 94faa0631d147189f08d55bbf69da202 (MD5) Previous issue date: 2014-02-18
OBJECTIVE: The focus of this study was to test the hypothesis that treatment time and oral pH had an influence on the physical chemical properties of orthodontic brackets and arch wires. METHODS: 120 metal brackets were evaluated. They were divided into 4 groups (n=30): Group C (Control) and Groups T12, T24 and
T36 (brackets recovered after 12, 24, and 36 months of treatment, respectively), rectangular stainless steel arch wires that remained in the oral cavity for 12 to 24 months were also analyzed. Dimensional stability, surface morphology and composition of brackets, resistance to sliding of the bracket/wire set and surface roughness of wires were analyzed by optical microscopy by measurement, scanning electron microscopy and energy dispersive x-ray, universal test machine and atomic force microscopy assays, respectively. Oral pH was evaluated by means of pH indicator strips by the colorimetric method. One-way analysis of variance ANOVA, followed by Tukey multiple comparisons test were used for statistical analysis (p<0.05). RESULTS: There was gradual influence of time from the 12th to 36th month for biofilm and food debris accumulation on bracket surfaces, presence of deformations on winglets and points of corrosion. Occlusal and cervical heights of brackets increased
significantly after clinical use for 36 months, compared with new bracket heights (p<0.05). Carbon and Oxygen were shown to be elements that increased expressively and in direct proportion to time, and there was a progressive increase in the coefficient of friction and roughness of wires as a function of time of clinical use after 36 months. Oral pH showed significant difference only between group T36 and its control (p<0.05). CONCLUSIONS: The hypothesis was partially accepted, brackets and orthodontic wires suffered significant physical-chemical changes due to clinical use. However, the treatment time and biofilm and debris accumulation in bracket slots were shown to have more influence on the degradation process and frictional force of these devices than oral pH.
OBJETIVO: Este estudo teve como foco atestar a hipótese de que o tempo de tratamento e o pH bucal possuem influência sobre as propriedades físico-químicas de fios e bráquetes ortodônticos. MÉTODOS: Cento
e vinte bráquetes metálicos foram avaliados, divididos em 4 grupos (n=30 por grupo): grupo C (Controle, como recebido do fabricante) e os grupos…
Advisors/Committee Members: Santos, Rogerio Lacerda dos.
Subjects/Keywords: Bráquetes Ortodônticos.; Fios ortodônticos.; Propriedades Físicas e Químicas.; Orthodontic Brackets.; Orthodontic Wires.; Physical and Chemical Properties.; CIENCIAS DA SAUDE::ODONTOLOGIA
Record Details
Similar Records
Cite
Share »
Record Details
Similar Records
Cite
« Share





❌
APA ·
Chicago ·
MLA ·
Vancouver ·
CSE |
Export
to Zotero / EndNote / Reference
Manager
APA (6th Edition):
Ramos, A. A. d. S. (2014). Propriedades físico-químicas de bráquetes e fios ortodônticos utilizados em diferentes tempos de tratamento. (Masters Thesis). Universidade Federal da Paraíba; Programa de Pós-Graduação em Odontologia; UFPB; Brasil; Odontologia. Retrieved from https://repositorio.ufpb.br/jspui/handle/tede/8868
Chicago Manual of Style (16th Edition):
Ramos, Aretha Aliny dos Santos. “Propriedades físico-químicas de bráquetes e fios ortodônticos utilizados em diferentes tempos de tratamento.” 2014. Masters Thesis, Universidade Federal da Paraíba; Programa de Pós-Graduação em Odontologia; UFPB; Brasil; Odontologia. Accessed April 19, 2021.
https://repositorio.ufpb.br/jspui/handle/tede/8868.
MLA Handbook (7th Edition):
Ramos, Aretha Aliny dos Santos. “Propriedades físico-químicas de bráquetes e fios ortodônticos utilizados em diferentes tempos de tratamento.” 2014. Web. 19 Apr 2021.
Vancouver:
Ramos AAdS. Propriedades físico-químicas de bráquetes e fios ortodônticos utilizados em diferentes tempos de tratamento. [Internet] [Masters thesis]. Universidade Federal da Paraíba; Programa de Pós-Graduação em Odontologia; UFPB; Brasil; Odontologia; 2014. [cited 2021 Apr 19].
Available from: https://repositorio.ufpb.br/jspui/handle/tede/8868.
Council of Science Editors:
Ramos AAdS. Propriedades físico-químicas de bráquetes e fios ortodônticos utilizados em diferentes tempos de tratamento. [Masters Thesis]. Universidade Federal da Paraíba; Programa de Pós-Graduação em Odontologia; UFPB; Brasil; Odontologia; 2014. Available from: https://repositorio.ufpb.br/jspui/handle/tede/8868
11.
ADRIANA CORREIA PEDRO.
ANÁLISE MICROSCÓPICA E DA RUGOSIDADE DE SUPERFÍCIE DE FIOS ORTODÔNTICOS ESTÉTICOS, ANTES E APÓS DEFLEXÃO.
Degree: 2011, Universidade Metodista de São Paulo
URL: http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2773
;
http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2774
;
http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2775
;
http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2776
;
http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2777
;
http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2778
;
http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2779
;
http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2780
► O objetivo deste estudo foi avaliar a topografia de superfície dos fios estéticos, antes e após teste de deflexão. A amostra foi composta por 70…
(more)
▼ O objetivo deste estudo foi avaliar a topografia de superfície dos fios estéticos, antes e após teste de deflexão. A amostra foi composta por 70 corpos de prova de fios 0,014 redondos, sendo 10 de cada uma das marcas comerciais avaliadas: Orthocosmetic Elastinol (Masel), Flexy Super Elastic Esthetic (Orthometric), InVu (TP Orthodontics) e ProForm Nitanium (Ortho Organizers) fios de NiTi revestidos por Teflon; Optis (TP Orthodontics) fio de resina reforçado por fibra de vidro ou FRP; Niticosmetic (Tecnident) fio de NiTi revestido por resina epoxídica; e Nitinol SE (3M Unitek) fio de NiTi superelástico, usado para controle. A topografia de superfície de cada fio foi avaliada por rugosímetro e por microscópio óptico, antes e após ser submetido a ensaio de deflexão, no lado em que a força foi aplicada e no lado oposto a este. Cada fio foi defletido em 3,1mm, a uma velocidade de 1mm/min, com célula de carga de 5N a 36⁰C + 1⁰C. A análise de variância a três critérios (p<0,05) mostrou diferença significante entre os fios e o teste de Tukey mostrou que o fio Optis (TP Orthodontics) apresentou aumento nos parâmetros de rugosidade Ra, Rt e Rz, após a deflexão. O fio Niticosmetic (Tecnident) apresentou aumento na rugosidade média (Ra). O fio InVu (TP Orthodontics) foi o único que mostrou aumento na rugosidade no lado em que a força foi aplicada. A análise visual por meio de microscopia óptica revelou alterações na superfície em todos os fios estéticos após o teste de deflexão, desde delaminações do revestimento, observadas nos fios Orthocosmetic Elastinol e InVu, riscos permanentes na superfície, como visto nos fios Flexy Super Elastic Esthetic, Niticosmetic e ProForm Nitanium, e até mesmo fratura incompleta, no fio Optis. Concluiu-se que o fio Niticosmetic apresentou topografia de superfície similar ao fio metálico, e os demais fios estéticos apresentaram maior rugosidade e alterações visuaisna superfície.
The aim of this study was evaluate surface topography of esthetic orthodontic wires, before and after three-point bending test. The sample consisted of 70 lenghts of wires 0,014 round section, 10 of which commercial brand assessed: Orthocosmetic Elastinol (Masel), Flexy Super Elastic Esthetic (Orthometric), InVu (TP Orthodontics) and ProForm Nitanium (Ortho Organizers) Teflon coated NiTi wires; Optis (TP Orthodontics) a fiber-reinforced plastic orthodontic wire named FRP; Niticosmetic (Tecnident) epoxy resin-coated NiTi wire; and Nitinol SE (3M Unitek) uncoated NiTi wire, used as control group. Surface topography of each wire was measured with a contact stylus perfilometer and with optical microscope, before and after being submitted to deflection, on side force was applied and on the opposite side. Each wire was 3,1mm deflected, at a speed of 1mm/min, with a 5N load cell, at 36⁰C + 1⁰C. Three criteria variance analysis (p<0,05) showed significant difference between assessed wires and Tukeys test showed Optis wire (TP Orthodontics) had increased parameters Ra, Rt and Rz mean values, after…
Advisors/Committee Members: GLADYS CRISTINA DOMINGUEZ RODRIGUEZ, Renata Cristina Faria Ribeiro de Castro, CLAUDIA TOYAMA HINO.
Subjects/Keywords: Fios ortodônticos; Estética; Topografia de Superfície; ODONTOLOGIA; Orthodontic wires; Esthetic; Surface topography.
Record Details
Similar Records
Cite
Share »
Record Details
Similar Records
Cite
« Share





❌
APA ·
Chicago ·
MLA ·
Vancouver ·
CSE |
Export
to Zotero / EndNote / Reference
Manager
APA (6th Edition):
PEDRO, A. C. (2011). ANÁLISE MICROSCÓPICA E DA RUGOSIDADE DE SUPERFÍCIE DE FIOS ORTODÔNTICOS ESTÉTICOS, ANTES E APÓS DEFLEXÃO. (Thesis). Universidade Metodista de São Paulo. Retrieved from http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2773 ; http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2774 ; http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2775 ; http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2776 ; http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2777 ; http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2778 ; http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2779 ; http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2780
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
Chicago Manual of Style (16th Edition):
PEDRO, ADRIANA CORREIA. “ANÁLISE MICROSCÓPICA E DA RUGOSIDADE DE SUPERFÍCIE DE FIOS ORTODÔNTICOS ESTÉTICOS, ANTES E APÓS DEFLEXÃO.” 2011. Thesis, Universidade Metodista de São Paulo. Accessed April 19, 2021.
http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2773 ; http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2774 ; http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2775 ; http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2776 ; http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2777 ; http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2778 ; http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2779 ; http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2780.
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
MLA Handbook (7th Edition):
PEDRO, ADRIANA CORREIA. “ANÁLISE MICROSCÓPICA E DA RUGOSIDADE DE SUPERFÍCIE DE FIOS ORTODÔNTICOS ESTÉTICOS, ANTES E APÓS DEFLEXÃO.” 2011. Web. 19 Apr 2021.
Vancouver:
PEDRO AC. ANÁLISE MICROSCÓPICA E DA RUGOSIDADE DE SUPERFÍCIE DE FIOS ORTODÔNTICOS ESTÉTICOS, ANTES E APÓS DEFLEXÃO. [Internet] [Thesis]. Universidade Metodista de São Paulo; 2011. [cited 2021 Apr 19].
Available from: http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2773 ; http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2774 ; http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2775 ; http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2776 ; http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2777 ; http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2778 ; http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2779 ; http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2780.
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
Council of Science Editors:
PEDRO AC. ANÁLISE MICROSCÓPICA E DA RUGOSIDADE DE SUPERFÍCIE DE FIOS ORTODÔNTICOS ESTÉTICOS, ANTES E APÓS DEFLEXÃO. [Thesis]. Universidade Metodista de São Paulo; 2011. Available from: http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2773 ; http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2774 ; http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2775 ; http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2776 ; http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2777 ; http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2778 ; http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2779 ; http://ibict.metodista.br/tedeSimplificado/tde_busca/arquivo.php?codArquivo=2780
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
12.
Rakalla, Amrita.
Composition, Phase Structure, and Corrosion of Nickel-Free and Nickel-Containing Stainless Steel Orthodontic Wires.
Degree: 2014, Marquette University
URL: https://epublications.marquette.edu/theses_open/267
► Stainless steel wires have long been used in orthodontics. The austenitic stainless steel used in orthodontics contains approximately 18 wt% chromium and 8 wt% nickel.…
(more)
▼ Stainless steel
wires have long been used in orthodontics. The austenitic stainless steel used in orthodontics contains approximately 18 wt% chromium and 8 wt% nickel. Nickel improves the corrosion resistance and helps maintain the austenite structure of stainless steel. Nickel is the most allergenic metal and is the most common metal associated with contact dermatitis in orthodontics. Nickel-free
wires have been developed, and it was the goal of this study to compare nickel-free and nickel-containing stainless steel
orthodontic wires to determine and compare their composition, phase structure, and corrosion properties. For each test, nickel-free and conventional stainless steel
wires were compared from four companies: Acme Monaco, Dentaurum, Leone, and Scheu-Dental. Phase structure was determined using x-ray diffraction. Composition was measured using scanning electron microscopy with energy dispersive spectroscopy. For each wire, straight lengths were sectioned into 1-inch segments, arranged side-by-side, to create a 1-inch by 1-inch planar array of
wires secured with sticky wax. Resultant XRD pattern peaks were indexed using standard methods or via ICDD files. Electrochemical corrosion tests were completed using a 3-electrode cell with a potentiostat and Gamry corrosion test software. Fusayama-Meyer artificial saliva solution was used as the electrolyte at room temperature. For each wire brand, wire lengths were isolated using nail polish, exposing a consistent surface area to account for varying diameters of the
wires among brands. Open circuit potential, polarization resistance, and corrosion current density were determined. Data were compared using one-way analysis of variance (ANOVA) at a 0.05 significance value with a Tukey's Studentized Range (HSD) Test post hoc analysis, where required. Two nickel-free
wires had detectable amounts of nickel. All nickel-free stainless steel
wires had an increased amount of manganese, chromium, and molybdenum with decreased iron content. The
orthodontic stainless steel
wires are mostly austenitic, but martensite may be present in both types. Although there were significant differences among the
wires for the three corrosion parameters, there was not a general difference between nickel-free and conventional stainless steel
wires. Overall, despite composition differences between the nickel-free and nickel-containing stainless steel
wires, they generally had the same phase structure and similar corrosion properties.
Advisors/Committee Members: Berzins, David W., Bradley,Thomas G., Liu, Dawei.
Subjects/Keywords: Composition; Corrosion; Nickel; Orthodontic wires; Phase structure; Stainless steel; Orthodontics and Orthodontology
Record Details
Similar Records
Cite
Share »
Record Details
Similar Records
Cite
« Share





❌
APA ·
Chicago ·
MLA ·
Vancouver ·
CSE |
Export
to Zotero / EndNote / Reference
Manager
APA (6th Edition):
Rakalla, A. (2014). Composition, Phase Structure, and Corrosion of Nickel-Free and Nickel-Containing Stainless Steel Orthodontic Wires. (Thesis). Marquette University. Retrieved from https://epublications.marquette.edu/theses_open/267
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
Chicago Manual of Style (16th Edition):
Rakalla, Amrita. “Composition, Phase Structure, and Corrosion of Nickel-Free and Nickel-Containing Stainless Steel Orthodontic Wires.” 2014. Thesis, Marquette University. Accessed April 19, 2021.
https://epublications.marquette.edu/theses_open/267.
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
MLA Handbook (7th Edition):
Rakalla, Amrita. “Composition, Phase Structure, and Corrosion of Nickel-Free and Nickel-Containing Stainless Steel Orthodontic Wires.” 2014. Web. 19 Apr 2021.
Vancouver:
Rakalla A. Composition, Phase Structure, and Corrosion of Nickel-Free and Nickel-Containing Stainless Steel Orthodontic Wires. [Internet] [Thesis]. Marquette University; 2014. [cited 2021 Apr 19].
Available from: https://epublications.marquette.edu/theses_open/267.
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
Council of Science Editors:
Rakalla A. Composition, Phase Structure, and Corrosion of Nickel-Free and Nickel-Containing Stainless Steel Orthodontic Wires. [Thesis]. Marquette University; 2014. Available from: https://epublications.marquette.edu/theses_open/267
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
13.
Alves, Celha Borges Costa.
Detecção de microorganismos em fios novos e usados.
Degree: 2015, Universidade Federal de Goiás; Programa de Pós-graduação em Odontologia (FO); UFG; Brasil; Faculdade de Odontologia – FO (RG)
URL: http://repositorio.bc.ufg.br/tede/handle/tede/7085
► Submitted by Erika Demachki ([email protected]) on 2017-04-05T20:56:34Z No. of bitstreams: 3 Dissertação - Celha Borges Costa Alves - 2015 - PARTE 01.pdf: 12922235 bytes, checksum:…
(more)
▼ Submitted by Erika Demachki ([email protected]) on 2017-04-05T20:56:34Z No. of bitstreams: 3 Dissertação - Celha Borges Costa Alves - 2015 - PARTE 01.pdf: 12922235 bytes, checksum: ef85b7e196e5b1e55c0484b1ee36b847 (MD5) Dissertação - Celha Borges Costa Alves - 2015 - PARTE 02.pdf: 10597055 bytes, checksum: 009b3f0a24c6157e6d3f5d069bb1138d (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Approved for entry into archive by Luciana Ferreira ([email protected]) on 2017-04-06T12:02:04Z (GMT) No. of bitstreams: 3 Dissertação - Celha Borges Costa Alves - 2015 - PARTE 01.pdf: 12922235 bytes, checksum: ef85b7e196e5b1e55c0484b1ee36b847 (MD5) Dissertação - Celha Borges Costa Alves - 2015 - PARTE 02.pdf: 10597055 bytes, checksum: 009b3f0a24c6157e6d3f5d069bb1138d (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Made available in DSpace on 2017-04-06T12:02:04Z (GMT). No. of bitstreams: 3
Dissertação - Celha Borges Costa Alves - 2015 - PARTE 01.pdf: 12922235 bytes, checksum: ef85b7e196e5b1e55c0484b1ee36b847 (MD5) Dissertação - Celha Borges Costa Alves - 2015 - PARTE 02.pdf: 10597055 bytes, checksum: 009b3f0a24c6157e6d3f5d069bb1138d (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2015-03-06
Os fios de níquel-titânio (NiTi) termoativados revolucionaram o campo da ortodontia em decorrência de sua capacidade elástica e memória de forma. Entretanto, essas características aumentam seu custo. A reutilização dos fios ortodônticos após o uso clínico e os processos de desinfecção e esterilização, mediante a comprovação de sua descontaminação total por intermédio de testes microbiológicos, permitiria baixar custos no tratamento ortodôntico, beneficiando o profissional e o paciente, além de contribuir para a preservação de recursos naturais. Assim, no presente estudo, objetivou-se avaliar a presença de micro-organismos na
superfície de fios ortodônticos novos e após uso clínico e submetidos a processos de desinfecção e esterilização, utilizando testes microbiológicos nos meios de cultura ágar sangue, ágar chocolate e ágar MacConkey. Para isso, foram utilizados 18 segmentos de fios de copper NiTi (Ormco®) de 0,018 pol, divididos em três grupos: a) grupo controle (GC) – seis segmentos de fios novos, como fornecido pelo fabricante; b) grupo 1 (G1) – seis segmentos de fios retirados de pacientes após 60 dias de uso clínico; c) grupo 2 (G2) – seis segmentos de fios retirados dos mesmos pacientes após 60 dias de uso clínico e submetidos a processos de desinfecção e esterilização. Os segmentos de fios do GC, G1 e G2 também foram avaliados por microscopia eletrônica de varredura (MEV) para detectar a presença de microorganismos e possíveis alterações de topografia. Constatou-se ausência de micro-organismos em 100% dos fios ortodônticos do GC e do G2 avaliados pelos testes microbiológicos, enquanto no G1
observou-se presença de micro-organismos em 100% das amostras analisadas. Conclui-se que o uso clínico dos…
Advisors/Committee Members: Lenza, Marcos Augusto, Lenza, Marcos Augusto, Nery, Cláudio de Góis, Fantini, Solange Mongelli de.
Subjects/Keywords: Reciclagem; Desinfecção; Esterilização; Fios ortodônticos; Recycling; Disinfection; Sterilization; Orthodontic wires; ODONTOLOGIA::CLINICA ODONTOLOGICA
Record Details
Similar Records
Cite
Share »
Record Details
Similar Records
Cite
« Share





❌
APA ·
Chicago ·
MLA ·
Vancouver ·
CSE |
Export
to Zotero / EndNote / Reference
Manager
APA (6th Edition):
Alves, C. B. C. (2015). Detecção de microorganismos em fios novos e usados. (Masters Thesis). Universidade Federal de Goiás; Programa de Pós-graduação em Odontologia (FO); UFG; Brasil; Faculdade de Odontologia – FO (RG). Retrieved from http://repositorio.bc.ufg.br/tede/handle/tede/7085
Chicago Manual of Style (16th Edition):
Alves, Celha Borges Costa. “Detecção de microorganismos em fios novos e usados.” 2015. Masters Thesis, Universidade Federal de Goiás; Programa de Pós-graduação em Odontologia (FO); UFG; Brasil; Faculdade de Odontologia – FO (RG). Accessed April 19, 2021.
http://repositorio.bc.ufg.br/tede/handle/tede/7085.
MLA Handbook (7th Edition):
Alves, Celha Borges Costa. “Detecção de microorganismos em fios novos e usados.” 2015. Web. 19 Apr 2021.
Vancouver:
Alves CBC. Detecção de microorganismos em fios novos e usados. [Internet] [Masters thesis]. Universidade Federal de Goiás; Programa de Pós-graduação em Odontologia (FO); UFG; Brasil; Faculdade de Odontologia – FO (RG); 2015. [cited 2021 Apr 19].
Available from: http://repositorio.bc.ufg.br/tede/handle/tede/7085.
Council of Science Editors:
Alves CBC. Detecção de microorganismos em fios novos e usados. [Masters Thesis]. Universidade Federal de Goiás; Programa de Pós-graduação em Odontologia (FO); UFG; Brasil; Faculdade de Odontologia – FO (RG); 2015. Available from: http://repositorio.bc.ufg.br/tede/handle/tede/7085
14.
Camargo, Lívio Bráulio Silva e.
Avaliação da influência do desgaste termomecânico nas propriedades mecânicas de fios ortodônticos de níquel-titânio termoativados.
Degree: 2014, Universidade Federal de Goiás; Programa de Pós-graduação em Odontologia (FO); UFG; Brasil; Faculdade de Odontologia – FO (RG)
URL: http://repositorio.bc.ufg.br/tede/handle/tede/7226
► Submitted by Erika Demachki ([email protected]) on 2017-04-25T20:09:52Z No. of bitstreams: 2 Dissertação - Lívio Bráulio Silva e Camargo - 2014.pdf: 13608179 bytes, checksum: 577554ee148810b74272f7b5a266db0b (MD5)…
(more)
▼ Submitted by Erika Demachki ([email protected]) on 2017-04-25T20:09:52Z No. of bitstreams: 2 Dissertação - Lívio Bráulio Silva e Camargo - 2014.pdf: 13608179 bytes, checksum: 577554ee148810b74272f7b5a266db0b (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Approved for entry into archive by Luciana Ferreira ([email protected]) on 2017-04-26T12:55:48Z (GMT) No. of bitstreams: 2 Dissertação - Lívio Bráulio Silva e Camargo - 2014.pdf: 13608179 bytes, checksum: 577554ee148810b74272f7b5a266db0b (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Made available in DSpace on 2017-04-26T12:55:48Z (GMT). No. of bitstreams: 2 Dissertação - Lívio Bráulio Silva e Camargo - 2014.pdf: 13608179 bytes, checksum: 577554ee148810b74272f7b5a266db0b (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2014-08-11
To evaluate the influence of thermal and
mechanical wear on the bending strength, topography and surface roughness of orthodontic NiTi wires Thermoset. Materials and Methods: round wire gauge section 0.018 "(0.045 mm) alloy NiTi (nickel titanium), thermoactivated (Dental Morelli, 3M/Abzil, American Orthodontics, Detsply GAC, Ormco) were selected. The samples were subjected to deflection test in a universal testing machine Instron 5965 model, and the atomic force microscope AFM model 5500, after being in thermocycled equipment Thermomechanical Wear Model ER 37000. Data were submitted to ANOVA statistical analysis and Tukey test, beyond the Spearman correlation coefficient with α = 0.05 significance. Results: By applying the deflection test at three points we observed that groups 1 and 4 matching results obtained, while the 2 and 3 equaled each other. The average force exerted by the wire was more pronounced in group 1 (control) than the rest. The wire Morelli which was developed as a higher average strength of the wire AO
less developed for all groups. By AFM, the wires of Thermoset Abzil and AO presented the most striking defects and Morelli thermoactivated showed less surface irregularities. The other wires were equal in quantity and severity of surface topographical, changes Conclusion: The test deflection at three points proved to be very effective for the desired goals. Demonstrating the equivalence between the control group and the group that was subjected to thermo-mechanical wear. Wires subjected to for just one wear, thermal or mechanical, proved to release more linear force. All Thermoset wires studied andsubmitted to the AFM, showed irregularities on the surface, with no significant differences between groups. The wires had higher surface smoothness were those who developed higher levels of strength in the load-deflection graph.
Objetivo:Avaliar a influência do desgaste térmico e mecânico na resistência à deflexão, topografia e rugosidade superficial de fios ortodônticos de níquel
titânio termoativados. Materiais e Métodos: Foram selecionados fios de secção redonda de calibre 0,018” (0,045mm) da liga de…
Advisors/Committee Members: Lenza, Marcos Augusto, Reges, Rogério Vieira, Lenza, Marcos Augusto, Nery, Cláudio Góis, Sakima, Maurício Tatsuei.
Subjects/Keywords: Fios ortodônticos; Propriedades mecânicas; Desgaste termomecânico; Orthodontic wires; Mechanical properties; Thermomechanical wear; ODONTOLOGIA::CLINICA ODONTOLOGICA
Record Details
Similar Records
Cite
Share »
Record Details
Similar Records
Cite
« Share





❌
APA ·
Chicago ·
MLA ·
Vancouver ·
CSE |
Export
to Zotero / EndNote / Reference
Manager
APA (6th Edition):
Camargo, L. B. S. e. (2014). Avaliação da influência do desgaste termomecânico nas propriedades mecânicas de fios ortodônticos de níquel-titânio termoativados. (Masters Thesis). Universidade Federal de Goiás; Programa de Pós-graduação em Odontologia (FO); UFG; Brasil; Faculdade de Odontologia – FO (RG). Retrieved from http://repositorio.bc.ufg.br/tede/handle/tede/7226
Chicago Manual of Style (16th Edition):
Camargo, Lívio Bráulio Silva e. “Avaliação da influência do desgaste termomecânico nas propriedades mecânicas de fios ortodônticos de níquel-titânio termoativados.” 2014. Masters Thesis, Universidade Federal de Goiás; Programa de Pós-graduação em Odontologia (FO); UFG; Brasil; Faculdade de Odontologia – FO (RG). Accessed April 19, 2021.
http://repositorio.bc.ufg.br/tede/handle/tede/7226.
MLA Handbook (7th Edition):
Camargo, Lívio Bráulio Silva e. “Avaliação da influência do desgaste termomecânico nas propriedades mecânicas de fios ortodônticos de níquel-titânio termoativados.” 2014. Web. 19 Apr 2021.
Vancouver:
Camargo LBSe. Avaliação da influência do desgaste termomecânico nas propriedades mecânicas de fios ortodônticos de níquel-titânio termoativados. [Internet] [Masters thesis]. Universidade Federal de Goiás; Programa de Pós-graduação em Odontologia (FO); UFG; Brasil; Faculdade de Odontologia – FO (RG); 2014. [cited 2021 Apr 19].
Available from: http://repositorio.bc.ufg.br/tede/handle/tede/7226.
Council of Science Editors:
Camargo LBSe. Avaliação da influência do desgaste termomecânico nas propriedades mecânicas de fios ortodônticos de níquel-titânio termoativados. [Masters Thesis]. Universidade Federal de Goiás; Programa de Pós-graduação em Odontologia (FO); UFG; Brasil; Faculdade de Odontologia – FO (RG); 2014. Available from: http://repositorio.bc.ufg.br/tede/handle/tede/7226
15.
Manoela Fávaro Francisconi.
Avaliação da força gerada pela deflexão gradual de fios ortodônticos em braquetes convencionais metálicos, estéticos e autoligáveis.
Degree: 2014, University of São Paulo
URL: http://www.teses.usp.br/teses/disponiveis/25/25144/tde-07012015-092552/
► PROPOSIÇÃO: O objetivo deste trabalho foi avaliar a força gerada pela deflexão de fios ortodônticos de Nitinol associados a diferentes tipos de braquetes por meio…
(more)
▼ PROPOSIÇÃO: O objetivo deste trabalho foi avaliar a força gerada pela deflexão de fios ortodônticos de Nitinol associados a diferentes tipos de braquetes por meio da avaliação dos valores da força através do aumento gradual do calibre e da deflexão dos fios e comparação entre as distintas combinações, nas diferentes deflexões. MATERIAL E MÉTODOS: Os corpos de prova foram montados em um modelo de simulação clínica e avaliados em uma máquina de ensaio universal INSTRON 3342, com célula de carga de 10N e, como protocolo, foi seguida a norma ISO 15.841. Foram confeccionados cinco destes modelos para a colagem de cada conjunto de acessórios a serem testados: metálico (Mini Diamond), policarbonato com fibra de vidro e canaleta metálica (Spirit), safira (Inspire ICE) e os autoligáveis passivo (Damon Q/Ormco) e ativo (In-Ovation R/GAC). Para os testes, o dispositivo de acrílico que representava o incisivo central direito foi movimentado no sentido
palatino-vestibular, com leituras das resistências geradas nas deflexões de 3; 2; 1 e 0,5mm, com velocidade constante de 2mm/min. Os resultados foram avaliados por meio da análise de variância (ANOVA) a dois e a um critério, havendo diferença significante, a análise comparativa das médias foi feita por meio do teste de Tukey (p<0,05). RESULTADOS: A força de desativação foi gradativamente maior, com o aumento do calibre dos arcos e maior deflexão, nos diferentes tipos de braquetes. Nas combinações entre os diferentes tipos de braquetes selecionados com os fios de Nitinol verificou-se que os braquetes autoligáveis foram os que apresentaram os resultados mais parecidos entre si, mantendo-os decrescentes conforme a deflexão diminuía. Já, entre os braquetes convencionais Mini Diamond, Spirit e Inspire ICE verificou-se que não existe um padrão em nenhuma deflexão estudada. CONCLUSÕES: A avaliação dos valores da força, através do aumento gradual do calibre e da deflexão dos fios,
demonstrou que a mesma foi crescente em todos os braquetes avaliados. Os braquetes autoligáveis foram os que apresentaram os resultados mais constantes e previsíveis enquanto que nos demais essa característica não foi observada.
OBJECTIVE: The purpose of this study was to evaluate the deflection forces of Nitinol orthodontic wires, placed in different kinds of brackets by assessing strength values variation according to gradual increase in the diameter and the deflection of the wires, comparing the different combinations, in the different deflections. MATERIAL AND METHODS: Specimens were mounted in a clinical simulation model and evaluated in a Universal Testing Machine (INSTRON 3342), using a 10 N load cell and, as a protocol, ISO 15841. Five of these models were prepared, each one for the bonding of each set of accessories to be tested: metallic (Mini Diamond), reinforced polycarbonate with metallic slots (Spirit), sapphire (Inspire ICE), and passive (Damon Q/Ormco) and active
self-ligated (In-Ovation R/GAC). For performing the tests, the acrylic device corresponding to the right central incisor was…
Advisors/Committee Members: Jose Fernando Castanha Henriques, Analu Giampietro Brandão, Daniela Gamba Garib Carreira, Alexandre Fortes Drummond, Karina Maria Salvatore de Freitas.
Subjects/Keywords: Elasticidade; Estudo Comparativo; Fenômenos Mecânicos; Fios Ortodônticos; Comparative Study; Elasticity; Mechanical Phenomena; Orthodontic Wires
Record Details
Similar Records
Cite
Share »
Record Details
Similar Records
Cite
« Share





❌
APA ·
Chicago ·
MLA ·
Vancouver ·
CSE |
Export
to Zotero / EndNote / Reference
Manager
APA (6th Edition):
Francisconi, M. F. (2014). Avaliação da força gerada pela deflexão gradual de fios ortodônticos em braquetes convencionais metálicos, estéticos e autoligáveis. (Doctoral Dissertation). University of São Paulo. Retrieved from http://www.teses.usp.br/teses/disponiveis/25/25144/tde-07012015-092552/
Chicago Manual of Style (16th Edition):
Francisconi, Manoela Fávaro. “Avaliação da força gerada pela deflexão gradual de fios ortodônticos em braquetes convencionais metálicos, estéticos e autoligáveis.” 2014. Doctoral Dissertation, University of São Paulo. Accessed April 19, 2021.
http://www.teses.usp.br/teses/disponiveis/25/25144/tde-07012015-092552/.
MLA Handbook (7th Edition):
Francisconi, Manoela Fávaro. “Avaliação da força gerada pela deflexão gradual de fios ortodônticos em braquetes convencionais metálicos, estéticos e autoligáveis.” 2014. Web. 19 Apr 2021.
Vancouver:
Francisconi MF. Avaliação da força gerada pela deflexão gradual de fios ortodônticos em braquetes convencionais metálicos, estéticos e autoligáveis. [Internet] [Doctoral dissertation]. University of São Paulo; 2014. [cited 2021 Apr 19].
Available from: http://www.teses.usp.br/teses/disponiveis/25/25144/tde-07012015-092552/.
Council of Science Editors:
Francisconi MF. Avaliação da força gerada pela deflexão gradual de fios ortodônticos em braquetes convencionais metálicos, estéticos e autoligáveis. [Doctoral Dissertation]. University of São Paulo; 2014. Available from: http://www.teses.usp.br/teses/disponiveis/25/25144/tde-07012015-092552/

Loma Linda University
16.
Liatti, Skyler J.
Effects of Wire Material, Deflection, and Interbracket Distance on Burstone Bracket Geometry Force Systems.
Degree: MS, Orthodontics and Dentofacial Orthopedics, 2017, Loma Linda University
URL: https://scholarsrepository.llu.edu/etd/479
► Objective. This paper aims to quantify the effect of wire material, dimension, and deflection on the most identifiable feature of the six-geometries: the moment…
(more)
▼ Objective. This paper aims to quantify the effect of wire material, dimension, and deflection on the most identifiable feature of the six-geometries: the moment dissociation point (force system with no moment on the lesser angled bracket), which may or may not occur at the classically defined geometry IV. Materials and Methods. A six-degree of freedom load cell was used to measure the force systems in different combinations of wire materials, wire dimensions, total angle of bracket, and interbracket distance. Brackets were progressively rotated through Burstone and Koenig’s six geometries and the moment on the right bracket was plotted against the ratio of the angle of the two brackets. Regression analysis was used to determine the angular relationship where the actual moment dissociation point occurred for each variable combination. The moment dissociation points were statistically compared. Results. There were significant differences in the moment dissociation points in the variables studied. A shift in the moment dissociation point toward what is classically considered a geometry III, with lower interbracket distance ratios (IBDr = the ratio of distances a) the higher angle bracket to the bracket slot plane intersection and b) total interbracket distance) with linear materials and low wire deflections was observed. Higher deflections showed a pattern more consistent with the theoretical geometry IV (IBDr 0.33). Superelastic phase transformation at extremely high deflections led to a shift towards a geometry III (lower IBDrs). Conclusions. The moment dissociation point was not always coincident with a geometry IV as classically defined by Burstone and Koenig. Variables including wire material properties, dimension, and wire deflection affect the location of the moment dissociation point to different extents. The classic geometries as defined by Burstone and Koenig are a simplification of a complex wire deflection problem, especially with phase transforming pseudoelastic
wires. In clinical situations, where one is attempting to create or predict the force system on brackets, these data should be taken into consideration, especially to avoid inconsistent force systems.
Advisors/Committee Members: Viecilli, Rodrigo F., Caruso, Joseph M., Rynearson, R. David.
Subjects/Keywords: Dentistry; Medicine and Health Sciences; Orthodontics and Orthodontology; Orthodontic Wires; Orthodontic Appliances; Orthodontic Appliance Design;
Record Details
Similar Records
Cite
Share »
Record Details
Similar Records
Cite
« Share





❌
APA ·
Chicago ·
MLA ·
Vancouver ·
CSE |
Export
to Zotero / EndNote / Reference
Manager
APA (6th Edition):
Liatti, S. J. (2017). Effects of Wire Material, Deflection, and Interbracket Distance on Burstone Bracket Geometry Force Systems. (Thesis). Loma Linda University. Retrieved from https://scholarsrepository.llu.edu/etd/479
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
Chicago Manual of Style (16th Edition):
Liatti, Skyler J. “Effects of Wire Material, Deflection, and Interbracket Distance on Burstone Bracket Geometry Force Systems.” 2017. Thesis, Loma Linda University. Accessed April 19, 2021.
https://scholarsrepository.llu.edu/etd/479.
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
MLA Handbook (7th Edition):
Liatti, Skyler J. “Effects of Wire Material, Deflection, and Interbracket Distance on Burstone Bracket Geometry Force Systems.” 2017. Web. 19 Apr 2021.
Vancouver:
Liatti SJ. Effects of Wire Material, Deflection, and Interbracket Distance on Burstone Bracket Geometry Force Systems. [Internet] [Thesis]. Loma Linda University; 2017. [cited 2021 Apr 19].
Available from: https://scholarsrepository.llu.edu/etd/479.
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
Council of Science Editors:
Liatti SJ. Effects of Wire Material, Deflection, and Interbracket Distance on Burstone Bracket Geometry Force Systems. [Thesis]. Loma Linda University; 2017. Available from: https://scholarsrepository.llu.edu/etd/479
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
17.
Herbert Ghersel.
"Relação entre força e deflexão na ativação e desativação de fios ortodônticos de níquel-titânio".
Degree: 2005, University of São Paulo
URL: http://www.teses.usp.br/teses/disponiveis/23/23140/tde-12012006-150318/
► O objetivo da presente pesquisa foi avaliar o comportamento da força em função da deflexão na ativação e desativação de fios ortodônticos de níquel-titânio, de…
(more)
▼ O objetivo da presente pesquisa foi avaliar o comportamento da força em função da deflexão na ativação e desativação de fios ortodônticos de níquel-titânio, de secção circular (.016"). Ensaiaram-se três marcas de fio (Forestadent, GAC e Morelli). As temperaturas de ensaio foram três (32, 37 e 42ºC). As ativações máximas foram até 1, 2, 3 e 4mm. O espécime de ensaio consistiu de uma placa de resina acrílica, sobre a qual eram fixados cilindros metálicos por meio de parafusos, simulando dentes, com distribuição semelhante aos dentes naturais. Sobre os cilindros foram cimentados os bráquetes (distância de 8mm entre eles). Sobre os bráquetes era fixado, conforme clinicamente, o arco do fio em ensaio. O dente" correspondente ao incisivo central era liberado (desparafusado) para poder se deslocar livremente no sentido vestíbulo-lingual durante os ensaios e o fio poder sofrer a deflexão. O conjunto era levado à máquina de ensaio (Instron), com câmara de
temperatura controlada. Durante o ensaio a velocidade de deslocamento para a deflexão foi de 0,5mm/min. Durante a ativação e desativação as forças foram registradas de 0,10 em 0,10mm de deflexão. Por meio de software esses valores eram impressos numericamente e em gráficos da força em função da ativação/desativação. Com 4 ativações máximas, 3 marcas de fios e 3 temperaturas obtiveram-se 36 condições experimentais e com 5 repetições (n=5) foram feitos 180 ensaios. Os gráficos obtidos mostraram uma não linearidade entre força e deflexão e com ativação de 1 e 2mm não foi detectado platô de superelasticidade, mas que foi observado na desativação, das ativações máximas de 3 e 4mm. Dos gráficos e tabelas foram extraídos valores específicos para serem analisados e comparados: 1) força máxima de ativação; 2/3) diminuição da força na desativação de 0,20mm e 0,70mm (esta só na ativação de 3 e 4mm); 4/5) extensão e forças no platô (apenas nas ativações máximas de 3 e 4mm); 6/7/8) desativação
até alcançar 50g de força, a partir de 0,80 e 1,80mm (ativações de 1 e 2mm), ou no final dos platôs (ativações de 3 e 4mm), a força ao iniciar-se a desativação, afastamento da origem ao registrar 50g de força; 9) deformação permanente ao atingir a força zero. As principais conclusões foram: a força de ativação máxima aumentou com o aumento desta e da temperatura, o material Morelli apresentou a menor e o GAC a maior; a diminuição da força máxima foi tanto maior quanto maior a ativação; apenas as ativações até 3 e 4mm apresentaram platôs de superelasticidade e que foram bem mais extensos na ativação de 4mm, que por sua vez apresentaram menor força; em todos os ensaios for observada deformação permanente
The purpose of this study was to evaluate the behaviour of force as function of loading and unloading orthodontic nickel-titanium wires. Three defferent brands (Forestadent, GAC and Morelli) were tested. Testing temperature were 32, 37 and 42 o C. Loading were up to 1, 2, 3 and
4mm deflection. Specimens consisted of a acrylic base where were fixed metallic cylinders simulating teeth. Over…
Advisors/Committee Members: Antonio Muench, Maria de Lourdes Rodrigues Accorinte, Julio de Araujo Gurgel, Estevao Tomomitsu Kimpara, Gladys Cristina Dominguez Rodriguez.
Subjects/Keywords: Fios de níquel-titânio; Fios ortodônticos; Superelasticidade; Nickel-titanium wires; Orthodontic wires; Superelasticity
Record Details
Similar Records
Cite
Share »
Record Details
Similar Records
Cite
« Share





❌
APA ·
Chicago ·
MLA ·
Vancouver ·
CSE |
Export
to Zotero / EndNote / Reference
Manager
APA (6th Edition):
Ghersel, H. (2005). "Relação entre força e deflexão na ativação e desativação de fios ortodônticos de níquel-titânio". (Doctoral Dissertation). University of São Paulo. Retrieved from http://www.teses.usp.br/teses/disponiveis/23/23140/tde-12012006-150318/
Chicago Manual of Style (16th Edition):
Ghersel, Herbert. “"Relação entre força e deflexão na ativação e desativação de fios ortodônticos de níquel-titânio".” 2005. Doctoral Dissertation, University of São Paulo. Accessed April 19, 2021.
http://www.teses.usp.br/teses/disponiveis/23/23140/tde-12012006-150318/.
MLA Handbook (7th Edition):
Ghersel, Herbert. “"Relação entre força e deflexão na ativação e desativação de fios ortodônticos de níquel-titânio".” 2005. Web. 19 Apr 2021.
Vancouver:
Ghersel H. "Relação entre força e deflexão na ativação e desativação de fios ortodônticos de níquel-titânio". [Internet] [Doctoral dissertation]. University of São Paulo; 2005. [cited 2021 Apr 19].
Available from: http://www.teses.usp.br/teses/disponiveis/23/23140/tde-12012006-150318/.
Council of Science Editors:
Ghersel H. "Relação entre força e deflexão na ativação e desativação de fios ortodônticos de níquel-titânio". [Doctoral Dissertation]. University of São Paulo; 2005. Available from: http://www.teses.usp.br/teses/disponiveis/23/23140/tde-12012006-150318/
18.
Couto, Cátia Sofia Alecrim.
O papel do flúor como agente corrosivo dos fios ortodônticos.
Degree: 2016, Universidade Fernando Pessoa
URL: http://www.rcaap.pt/detail.jsp?id=oai:bdigital.ufp.pt:10284/5578
► O tratamento ortodôntico insere-se numa área da medicina dentária que se dedica ao estudo das formas de prevenir, interceptar e corrigir as más posições dos…
(more)
▼ O tratamento ortodôntico insere-se numa área da medicina dentária que se dedica ao estudo das formas de prevenir, interceptar e corrigir as más posições dos dentes e dos maxilares. Durante este tratamento é importante que os pacientes consigam manter uma boa higiene oral dos dentes e do aparelho, o que requer precisão e tempo. Para ajudar a manter a higiene oral os pacientes recorrem frequentemente ao uso de produtos fluoretados, que apesar dos seus benefícios como agentes na prevenção da cárie têm consequências no tratamento ortodôntico nomeadamente na corrosão dos fios ortodônticos. Através de uma revisão da literatura pretende-se explorar a relação entre o uso de flúor durante o tratamento ortodôntico com a corrosão dos fios mais usados nesse mesmo tratamento.
Materiais e Métodos: Nesta revisão de literatura realizou-se pesquisa nas bases de dados electrónicas “Medline/PubMed”, e “B-On”; referências bibliográficas de artigos; livros de Medicina Dentária e pesquisa narrativa.
Conclusão: O uso de agentes fluoretados tópicos pode induzir uma diminuição das propriedades mecânicas dos fios ortodônticos nomeadamente do níquel-titânio, e consequentemente provocar o prolongamento do tratamento ortodôntico. Os Ortodontistas devem ter em consideração o tipo de fio usado no tratamento no momento da prescrição de colutórios e outros agentes fluoretados.
Orthodontic treatment is inserted in a field of dentistry that deals with the study of ways to prevent, intercept and correct the bad position of the teeth and jaws. During this treatment it is important that patients are able to maintain good oral hygiene of teeth and oral devices, which requires accuracy and time. To help maintain oral hygiene patients often resort to the use of fluoridated products, which despite its benefits as agents in the prevention of tooth decay have consequences in orthodontic treatment including the corrosion of orthodontic wires. Through a literature review it is intended to explore the relationship between the use of fluoride during orthodontic treatment with the corrosion of wires commonly used in the same treatment.
Materials and Methods: In this literature review was carried out research in electronic databases "Medline / PubMed" and "B-On"; references of articles; books of Dental Medicine and narrative research.
Conclusion: The use of fluoride topical agents can induce a decrease of mechanical properties of orthodontic wires in particular nickel-titanium, and thus cause the extension of orthodontic treatment. Orthodontists must take into account the type of wire used in the treatment when prescribing mouthwashes and other fluoridated agents.
Advisors/Committee Members: Bulhosa, José Frias.
Subjects/Keywords: Fios Ortodônticos; Corrosão; Flúor; Flúor tópico; Orthodontic wires; Corrosion; Fluoride; Fluoride topical; Domínio/Área Científica::Ciências Médicas::Medicina Clínica
Record Details
Similar Records
Cite
Share »
Record Details
Similar Records
Cite
« Share





❌
APA ·
Chicago ·
MLA ·
Vancouver ·
CSE |
Export
to Zotero / EndNote / Reference
Manager
APA (6th Edition):
Couto, C. S. A. (2016). O papel do flúor como agente corrosivo dos fios ortodônticos. (Thesis). Universidade Fernando Pessoa. Retrieved from http://www.rcaap.pt/detail.jsp?id=oai:bdigital.ufp.pt:10284/5578
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
Chicago Manual of Style (16th Edition):
Couto, Cátia Sofia Alecrim. “O papel do flúor como agente corrosivo dos fios ortodônticos.” 2016. Thesis, Universidade Fernando Pessoa. Accessed April 19, 2021.
http://www.rcaap.pt/detail.jsp?id=oai:bdigital.ufp.pt:10284/5578.
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
MLA Handbook (7th Edition):
Couto, Cátia Sofia Alecrim. “O papel do flúor como agente corrosivo dos fios ortodônticos.” 2016. Web. 19 Apr 2021.
Vancouver:
Couto CSA. O papel do flúor como agente corrosivo dos fios ortodônticos. [Internet] [Thesis]. Universidade Fernando Pessoa; 2016. [cited 2021 Apr 19].
Available from: http://www.rcaap.pt/detail.jsp?id=oai:bdigital.ufp.pt:10284/5578.
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
Council of Science Editors:
Couto CSA. O papel do flúor como agente corrosivo dos fios ortodônticos. [Thesis]. Universidade Fernando Pessoa; 2016. Available from: http://www.rcaap.pt/detail.jsp?id=oai:bdigital.ufp.pt:10284/5578
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
19.
Clark, Kathryn J.
Corrosion and nickel ion release of nickel titanium archwires with ion implantation technology in deflected and nondeflected states.
Degree: MS, 2009, Oregon Health Sciences University
URL: doi:10.6083/M4C24V51
;
http://digitalcommons.ohsu.edu/etd/3641
Subjects/Keywords: Corrosion; Nickel; Titanium; Orthodontic Wires; Hypersensitivity; Orthodontics and Orthodontology
Record Details
Similar Records
Cite
Share »
Record Details
Similar Records
Cite
« Share





❌
APA ·
Chicago ·
MLA ·
Vancouver ·
CSE |
Export
to Zotero / EndNote / Reference
Manager
APA (6th Edition):
Clark, K. J. (2009). Corrosion and nickel ion release of nickel titanium archwires with ion implantation technology in deflected and nondeflected states. (Thesis). Oregon Health Sciences University. Retrieved from doi:10.6083/M4C24V51 ; http://digitalcommons.ohsu.edu/etd/3641
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
Chicago Manual of Style (16th Edition):
Clark, Kathryn J. “Corrosion and nickel ion release of nickel titanium archwires with ion implantation technology in deflected and nondeflected states.” 2009. Thesis, Oregon Health Sciences University. Accessed April 19, 2021.
doi:10.6083/M4C24V51 ; http://digitalcommons.ohsu.edu/etd/3641.
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
MLA Handbook (7th Edition):
Clark, Kathryn J. “Corrosion and nickel ion release of nickel titanium archwires with ion implantation technology in deflected and nondeflected states.” 2009. Web. 19 Apr 2021.
Vancouver:
Clark KJ. Corrosion and nickel ion release of nickel titanium archwires with ion implantation technology in deflected and nondeflected states. [Internet] [Thesis]. Oregon Health Sciences University; 2009. [cited 2021 Apr 19].
Available from: doi:10.6083/M4C24V51 ; http://digitalcommons.ohsu.edu/etd/3641.
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
Council of Science Editors:
Clark KJ. Corrosion and nickel ion release of nickel titanium archwires with ion implantation technology in deflected and nondeflected states. [Thesis]. Oregon Health Sciences University; 2009. Available from: doi:10.6083/M4C24V51 ; http://digitalcommons.ohsu.edu/etd/3641
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
20.
Prado, Murilo de Melo.
Efeito da esterilização e uso clínico nas propriedades mecânicas e rugosidade superficial dos fios de níquel titânio.
Degree: 2015, Universidade Federal de Goiás; Programa de Pós-graduação em Odontologia (FO); UFG; Brasil; Faculdade de Odontologia – FO (RG)
URL: http://repositorio.bc.ufg.br/tede/handle/tede/4696
► Submitted by Luciana Ferreira ([email protected]) on 2015-10-21T11:25:26Z No. of bitstreams: 2 Dissertação - Murilo de Melo Prado - 2015.pdf: 11846576 bytes, checksum: c1b512a579f2a2894ce18a2204e03be5 (MD5) license_rdf:…
(more)
▼ Submitted by Luciana Ferreira ([email protected]) on 2015-10-21T11:25:26Z No. of bitstreams: 2 Dissertação - Murilo de Melo Prado - 2015.pdf: 11846576 bytes, checksum: c1b512a579f2a2894ce18a2204e03be5 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Approved for entry into archive by Luciana Ferreira ([email protected]) on 2015-10-21T11:40:15Z (GMT) No. of bitstreams: 2 Dissertação - Murilo de Melo Prado - 2015.pdf: 11846576 bytes, checksum: c1b512a579f2a2894ce18a2204e03be5 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Made available in DSpace on 2015-10-21T11:40:15Z (GMT). No. of bitstreams: 2 Dissertação - Murilo de Melo Prado - 2015.pdf: 11846576 bytes, checksum: c1b512a579f2a2894ce18a2204e03be5 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2015-03-25
This study evaluated the effects of sterilization and clinical
use in the mechanical properties and surface roughness gauge wires 0.018 "nickel titanium termoset, with the addition of copper covers: Ormco (Glendora, CA, USA). Twenty-four samples were the evaluation of mechanical behavior in the load test and deflection, the scanning electron microscopy and atomic force microscope to check surface roughness. The tests were performed in four different situations: 1-packaged by the manufacturer (control); 2- packaged by the manufacturer and autoclaved; 3- after clinical use 60 days and disinfection and 4- and autoclaved clinical use. The data were submitted to ANOVA and Tukey test. By applying the deflection test on three points could be observed that the wires in all groups showed mechanical behavior in the activation / deactivation similar, with no significant statistical differences. All wires reached the end point of deactivation with forces approximate the control group (1.398 ± 0.19 N / mm). The AFM and SEM, all thermoset wires showed
irregularities in its surface topography, and there were no major changes in surface pattern between the groups for the analyzed wire. The qualitative evaluation of surface roughness showed grooves and craters, influencing the surface of the wires smoothness, while the quantitative analyzes showed no statistically significant difference between the groups evaluated. The concluse is that sterilize the wires and use them clinically for 60 days did not alter the mechanical behavior and the surface roughness of the wires 0.018" NiTi Thermoset with addition of copper.
Este estudo avaliou os efeitos da esterilização e uso clínico nas propriedades mecânicas e rugosidade superficial de fios calibre 0,018” de níquel titânio termoativado com adição de cobre da marca: Ormco (Glendora, CA, USA). Vinte e quatro amostras foram submetidas à avaliação do comportamento mecânico no teste de carga e deflexão, à microscopia eletrônica de varredura e microscópio de força atômica para verificação da
rugosidade superficial. Os testes foram realizados em quatro situações distintas: 1- embalado pelo…
Advisors/Committee Members: Lenza, Marcos Augusto, Lenza, Marcos Augusto, Nery, Claudio de Gois, Jakob, Sergio Ricardo.
Subjects/Keywords: Fios ortodonticos; Rugosidade superficial; Propriedade mecanica; Orthodontic wires; Mechanical property; Surface roughness; CIENCIAS DA SAUDE::ODONTOLOGIA
Record Details
Similar Records
Cite
Share »
Record Details
Similar Records
Cite
« Share





❌
APA ·
Chicago ·
MLA ·
Vancouver ·
CSE |
Export
to Zotero / EndNote / Reference
Manager
APA (6th Edition):
Prado, M. d. M. (2015). Efeito da esterilização e uso clínico nas propriedades mecânicas e rugosidade superficial dos fios de níquel titânio. (Masters Thesis). Universidade Federal de Goiás; Programa de Pós-graduação em Odontologia (FO); UFG; Brasil; Faculdade de Odontologia – FO (RG). Retrieved from http://repositorio.bc.ufg.br/tede/handle/tede/4696
Chicago Manual of Style (16th Edition):
Prado, Murilo de Melo. “Efeito da esterilização e uso clínico nas propriedades mecânicas e rugosidade superficial dos fios de níquel titânio.” 2015. Masters Thesis, Universidade Federal de Goiás; Programa de Pós-graduação em Odontologia (FO); UFG; Brasil; Faculdade de Odontologia – FO (RG). Accessed April 19, 2021.
http://repositorio.bc.ufg.br/tede/handle/tede/4696.
MLA Handbook (7th Edition):
Prado, Murilo de Melo. “Efeito da esterilização e uso clínico nas propriedades mecânicas e rugosidade superficial dos fios de níquel titânio.” 2015. Web. 19 Apr 2021.
Vancouver:
Prado MdM. Efeito da esterilização e uso clínico nas propriedades mecânicas e rugosidade superficial dos fios de níquel titânio. [Internet] [Masters thesis]. Universidade Federal de Goiás; Programa de Pós-graduação em Odontologia (FO); UFG; Brasil; Faculdade de Odontologia – FO (RG); 2015. [cited 2021 Apr 19].
Available from: http://repositorio.bc.ufg.br/tede/handle/tede/4696.
Council of Science Editors:
Prado MdM. Efeito da esterilização e uso clínico nas propriedades mecânicas e rugosidade superficial dos fios de níquel titânio. [Masters Thesis]. Universidade Federal de Goiás; Programa de Pós-graduação em Odontologia (FO); UFG; Brasil; Faculdade de Odontologia – FO (RG); 2015. Available from: http://repositorio.bc.ufg.br/tede/handle/tede/4696
21.
Ferreira, Gaudyer Castro Di.
Propriedades mecânicas e avaliação microscópica de fios ortodônticos de niti revestidos por polímeros.
Degree: 2015, Universidade Federal de Goiás; Programa de Pós-graduação em Odontologia (FO); UFG; Brasil; Faculdade de Odontologia – FO (RG)
URL: http://repositorio.bc.ufg.br/tede/handle/tede/5263
► Submitted by Luciana Ferreira ([email protected]) on 2016-02-23T11:24:55Z No. of bitstreams: 2 Dissertação - Gaudyer Castro di Ferreira - 2015.pdf: 12501436 bytes, checksum: 06af9912db4067aacec6a4dec872f91a (MD5) license_rdf:…
(more)
▼ Submitted by Luciana Ferreira ([email protected]) on 2016-02-23T11:24:55Z No. of bitstreams: 2 Dissertação - Gaudyer Castro di Ferreira - 2015.pdf: 12501436 bytes, checksum: 06af9912db4067aacec6a4dec872f91a (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Approved for entry into archive by Luciana Ferreira ([email protected]) on 2016-02-23T11:27:08Z (GMT) No. of bitstreams: 2 Dissertação - Gaudyer Castro di Ferreira - 2015.pdf: 12501436 bytes, checksum: 06af9912db4067aacec6a4dec872f91a (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Made available in DSpace on 2016-02-23T11:27:08Z (GMT). No. of bitstreams: 2 Dissertação - Gaudyer Castro di Ferreira - 2015.pdf: 12501436 bytes, checksum: 06af9912db4067aacec6a4dec872f91a (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2015-03-24
The objective of the study was to analyze the
mechanical properties and analyze the surface of the wires coated polymers. Methods: We used the pre-contoured wires study with dimension of 0.014 "Nickel- Titanium (NiTi) brands: Tecident orthodontic equipment Ltda (São Carlos, São Paulo Brazil), TP Orthodontics (Indiana, USA), Trianeiro ( Rio Claro, São Paulo Brazil) and NiTi wire Morelli (Sorocaba, Sao Paulo Brazil) as a control group. The yarns were randomly divided into 11 groups (n = 6) .There were carried deflection test. The yarns were immersed in artificial saliva for a period of 30 to 60 days to corrode. After the wire corrosion were also submitted for the analysis of Scanning Electron Microscopy (SEM). Results: We used the ANOVA analysis of variance, which were statistically significant differences between the tested wire and the controle.Foram group observed imperfections on the surfaces of all the wire and the wire TP Orthodontics showed the greatest changes. Conclusions: The polymeric coating appears to be responsible
for the mechanical surface change and the NiTi wires.
O objetivo do estudo foi analisar as propriedades mecânicas e analisar a superfície, dos fios revestidos por polímeros. Materiais e métodos: Foram utilizados no estudo fios pré-contornados com dimensão de 0.014” de Niquel-Titânio (NiTi) das marcas: Tecident Equipamento Ortodonticos Ltda(São Carlos,São Paulo Brasil), TP Orthodontics (Indiana, EUA) , Trianeiro (Rio Claro, São Paulo Brasil) e fio NiTi Morelli ( Sorocaba, São Paulo Brasil) como grupo controle. Os fios foram divididos aleatoriamente em 11 grupos (n=6).Foram realizado o teste de deflexão. Os fios foram imersos em saliva artificial por um período de 30 e 60 dias,para sofrer corrosão. Após a corrosão os fio também foram submetidos para a análise de Microscopia Eletrônica de Varredura (MEV). Resultados:Foi utilizado o teste de variância ANOVA, onde foram observadas diferenças estatisticamente significantes entre os fios testados e os do grupo controle.Foram observadas
imperfeições nas superfícies de todos os fio sendo que o fio da TP Orthodontics…
Advisors/Committee Members: Lenza, Marcos Augusto, Lenza, Marcos Augusto, Monini, André, Lenza, Eduardo Beaton.
Subjects/Keywords: Fios ortodônticos; Propriedades superficiais; Microscopia eletrônica de varredura; Orthodontic wires; Surface properties; Microscopy; CIENCIAS DA SAUDE::ODONTOLOGIA
Record Details
Similar Records
Cite
Share »
Record Details
Similar Records
Cite
« Share





❌
APA ·
Chicago ·
MLA ·
Vancouver ·
CSE |
Export
to Zotero / EndNote / Reference
Manager
APA (6th Edition):
Ferreira, G. C. D. (2015). Propriedades mecânicas e avaliação microscópica de fios ortodônticos de niti revestidos por polímeros. (Masters Thesis). Universidade Federal de Goiás; Programa de Pós-graduação em Odontologia (FO); UFG; Brasil; Faculdade de Odontologia – FO (RG). Retrieved from http://repositorio.bc.ufg.br/tede/handle/tede/5263
Chicago Manual of Style (16th Edition):
Ferreira, Gaudyer Castro Di. “Propriedades mecânicas e avaliação microscópica de fios ortodônticos de niti revestidos por polímeros.” 2015. Masters Thesis, Universidade Federal de Goiás; Programa de Pós-graduação em Odontologia (FO); UFG; Brasil; Faculdade de Odontologia – FO (RG). Accessed April 19, 2021.
http://repositorio.bc.ufg.br/tede/handle/tede/5263.
MLA Handbook (7th Edition):
Ferreira, Gaudyer Castro Di. “Propriedades mecânicas e avaliação microscópica de fios ortodônticos de niti revestidos por polímeros.” 2015. Web. 19 Apr 2021.
Vancouver:
Ferreira GCD. Propriedades mecânicas e avaliação microscópica de fios ortodônticos de niti revestidos por polímeros. [Internet] [Masters thesis]. Universidade Federal de Goiás; Programa de Pós-graduação em Odontologia (FO); UFG; Brasil; Faculdade de Odontologia – FO (RG); 2015. [cited 2021 Apr 19].
Available from: http://repositorio.bc.ufg.br/tede/handle/tede/5263.
Council of Science Editors:
Ferreira GCD. Propriedades mecânicas e avaliação microscópica de fios ortodônticos de niti revestidos por polímeros. [Masters Thesis]. Universidade Federal de Goiás; Programa de Pós-graduação em Odontologia (FO); UFG; Brasil; Faculdade de Odontologia – FO (RG); 2015. Available from: http://repositorio.bc.ufg.br/tede/handle/tede/5263
22.
Mariana de Aguiar Bulhões Galvão.
Avaliação da resistência ao deslocamento na sobreposição de fios de níquel e titânio superelásticos termoativados em braquetes autoligáveis passivos.
Degree: 2014, University of São Paulo
URL: http://www.teses.usp.br/teses/disponiveis/23/23151/tde-19022015-151109/
► Objetivos: O objetivo desta pesquisa foi comparar a resistência ao deslocamento de fios de níquel e titânio superelásticos termoativados sobrepostos, em braquetes ortodônticos metálicos autoligáveis…
(more)
▼ Objetivos: O objetivo desta pesquisa foi comparar a resistência ao deslocamento de fios de níquel e titânio superelásticos termoativados sobrepostos, em braquetes ortodônticos metálicos autoligáveis passivos. Material e Métodos: Foram utilizadas três espessuras de fios de níquel e titânio superelásticos termoativados (NiTi-TA): 0,014 sobreposto ao 0,016 e 0,020 (FlexyNiTi Thermal - Orthometric, Marília, SP, BR), associados a dois tipos de braquetes metálicos autoligáveis passivos: SmartClip SL3® (3M Unitek, Monrovia, CA, EUA) e OrthoClip SLB® (Orthometric, Marília, SP, BR). Um dispositivo que continha 5 braquetes de cada tipo (do incisivo central superior direito ao 2º pré-molar superior direito) foi desenvolvido para realização dos testes. O braquete do canino foi colado em uma barra de aço inoxidável móvel que permitia alterar sua posição vertical, enquanto os demais braquetes foram colados a uma barra fixa de acrílico. As forças obtidas por meio
do deslocamento vertical do braquete do canino de 0mm para 1,5mm, 3,0 mm, 4,5mm e 6,0 mm foram registradas. O ambiente de teste foi seco com temperatura controlada de 36,5º C ± 1º C. Um total de 160 testes foi realizado na máquina de ensaios universal Instron. Os testes estatísticos de Shapiro-Wilk, teste t de Student não pareado e ANOVA com testes post-hoc de Tukey foram aplicados aos dados (p<0,05). Resultados: A distribuição normal da amostra foi confirmada, e os testes paramétricos demonstraram que houve diferenças estatisticamente significativas no braquete SmartClip SL3® quando associados aos fios de NiTi-TA 0,020 e 0,014 sobreposto ao 0,016 nas alturas de 1,5mm (p=0,003) e 6mm (p0,0001). Porém, não foram encontradas diferenças estatísticas nas alturas de 3mm (p=0,76) e 4,5mm (p=0,09). No braquete OrthoClip SLB® houve diferenças estatisticamente significativas entre os fios de NiTi-TA 0,020 e 0,014 sobreposto ao 0,016 em todas as alturas avaliadas (p0,0001). Na
comparação entre os braquetes, quando associados ao fio 0,020 de NiTi-TA houve diferenças estatisticamente significativas na altura de 1,5mm; 3mm e 6mm (p0,0001). No entanto, na altura de 4,5mm as diferenças não foram significativas estatisticamente (p=0,32). Quando associados aos fios de NiTi-TA 0,014 e 0,016 sobrepostos, as diferenças em todas as alturas avaliadas foram significativas estatisticamente (1,5mm - p=0,0006; nas demais alturas p0,0001). Conclusão: Nos braquetes SmartClip SL3®, em desnivelamentos de 1,5mm, os fios de NiTi-TA 0,014 e 0,016 sobrepostos apresentaram menor resistência ao deslocamento, enquanto que na altura de 6mm a menor resistência foi obtida com o fio de NiTi-TA 0,020. Nas demais alturas não houve diferenças estatísticas entre os fios. Para os braquetes OrthoClip SLB®, os fios de NiTi-TA 0,014 e 0,016 sobrepostos apresentaram menor resistência ao deslocamento em todas as alturas avaliadas. Na comparação entre os dois tipos de braquetes, associados ao fio
de NiTi-TA 0,020 na altura de 1,5mm, o braquete OrthoClip SLB® apresentou menor resistência ao deslocamento, ao passo que nas…
Advisors/Committee Members: Gladys Cristina Dominguez Morea, Ricardo Fidos Horliana, Igor Studart Medeiros, Dirceu Barnabé Raveli, André Tortamano.
Subjects/Keywords: Braquetes autoligáveis; Fios ortodônticos de níquel e titânio; Resistência friccional; Frictional resistance; Nickel titanium orthodontic wires; Self-ligating brackets
Record Details
Similar Records
Cite
Share »
Record Details
Similar Records
Cite
« Share





❌
APA ·
Chicago ·
MLA ·
Vancouver ·
CSE |
Export
to Zotero / EndNote / Reference
Manager
APA (6th Edition):
Galvão, M. d. A. B. (2014). Avaliação da resistência ao deslocamento na sobreposição de fios de níquel e titânio superelásticos termoativados em braquetes autoligáveis passivos. (Doctoral Dissertation). University of São Paulo. Retrieved from http://www.teses.usp.br/teses/disponiveis/23/23151/tde-19022015-151109/
Chicago Manual of Style (16th Edition):
Galvão, Mariana de Aguiar Bulhões. “Avaliação da resistência ao deslocamento na sobreposição de fios de níquel e titânio superelásticos termoativados em braquetes autoligáveis passivos.” 2014. Doctoral Dissertation, University of São Paulo. Accessed April 19, 2021.
http://www.teses.usp.br/teses/disponiveis/23/23151/tde-19022015-151109/.
MLA Handbook (7th Edition):
Galvão, Mariana de Aguiar Bulhões. “Avaliação da resistência ao deslocamento na sobreposição de fios de níquel e titânio superelásticos termoativados em braquetes autoligáveis passivos.” 2014. Web. 19 Apr 2021.
Vancouver:
Galvão MdAB. Avaliação da resistência ao deslocamento na sobreposição de fios de níquel e titânio superelásticos termoativados em braquetes autoligáveis passivos. [Internet] [Doctoral dissertation]. University of São Paulo; 2014. [cited 2021 Apr 19].
Available from: http://www.teses.usp.br/teses/disponiveis/23/23151/tde-19022015-151109/.
Council of Science Editors:
Galvão MdAB. Avaliação da resistência ao deslocamento na sobreposição de fios de níquel e titânio superelásticos termoativados em braquetes autoligáveis passivos. [Doctoral Dissertation]. University of São Paulo; 2014. Available from: http://www.teses.usp.br/teses/disponiveis/23/23151/tde-19022015-151109/
23.
Carlos Alberto Rodrigues de Gouvêa.
Desenvolvimento de laminador para confecção de fios ortodônticos retangulares e suas caracterizações.
Degree: 2008, University of São Paulo
URL: http://www.teses.usp.br/teses/disponiveis/88/88131/tde-14052010-172628/
► Nos tratamentos ortodônticos, fios de diferentes ligas metálicas são utilizados nas etapas de alinhamento, nivelamento, correção da posição molar, fechamento espacial, acabamento e retenção. Com…
(more)
▼ Nos tratamentos ortodônticos, fios de diferentes ligas metálicas são utilizados nas etapas de alinhamento, nivelamento, correção da posição molar, fechamento espacial, acabamento e retenção. Com relação às duas últimas, responsáveis pelo posicionamento adequado dos dentes superiores sobre os inferiores, a preparação requer um fio que favoreça o torque de incisão, ou seja, que apresente grande resistência e rigidez associadas à ativação de pequeno alcance. Para este fim, os fios de aços inoxidáveis austeníticos retangulares são os preferidos em razão do módulo de elasticidade elevado e boa resistência à corrosão no meio bucal. Quanto à geometria retangular, o processo de fabricação requer desenvolvimento tecnológico adequado para a produção em escala industrial de fios com as características geométricas e propriedades mecânicas para melhor adequação às necessidades de uso. Com o objetivo de se produzir fios com tais características, foi desenvolvido
um laminador para a fabricação de fios retangulares com a intuito de se dispor de uma alternativa de menor custo ao processo de produção por trefilação, de custo elevado, devido a complexidade das matrizes. Além da fabricação do laminador, foram avaliados os aspectos tecnológicos que envolveram os efeitos da deformação nas propriedades mecânicas dos fios, por meio de medidas de microdurezas e ensaios em tração e de flexão. Nos testes realizados, os fios apresentaram geometria, acabamento superficial e propriedades mecânicas adequadas à sua utilização em tratamentos ortodônticos.
In orthodontic treatments, wires of different metallic alloys are used for alignment, leveling, correction of the molar position, space closing, finish and retention. With respect to finish and retention, these wires are responsible for adequate positioning of the upper teeth on the lower teeth. Wires that are subjected to incisor torque require high resistance and stiffness. For this, wires of
rectangular austenitic stainless steel are used due to high modulus of elasticity and good corrosion resistance in the oral environment. Because of the rectangular geometry, wire production requires process development suitable for industrial scale manufacture with geometric characteristics and mechanical properties better adapted to the use conditions. To obtain wires with such characteristics, a rolling mill was developed for the production of rectangular wires by a rolling process with the objective of reducing cost of the cold drawing process that is currently used, which utilize complex and expensive wiredrawing dies. In addition to the rolling process itself, wire deformation, microhardness, tension and bend tests were also performed. In these tests, wire geometry, surface finish and mechanical properties were successfully adapted for use in orthodontic treatments.
Advisors/Committee Members: Luiz Carlos Casteletti, Maria Clara Filippini Ierardi, Tomaz Toshimi Ishikawa.
Subjects/Keywords: Fios retangulares; Laminador; Ortodontia; Orthodontic; Rectangular wires; Rolling mill
Record Details
Similar Records
Cite
Share »
Record Details
Similar Records
Cite
« Share





❌
APA ·
Chicago ·
MLA ·
Vancouver ·
CSE |
Export
to Zotero / EndNote / Reference
Manager
APA (6th Edition):
Gouvêa, C. A. R. d. (2008). Desenvolvimento de laminador para confecção de fios ortodônticos retangulares e suas caracterizações. (Masters Thesis). University of São Paulo. Retrieved from http://www.teses.usp.br/teses/disponiveis/88/88131/tde-14052010-172628/
Chicago Manual of Style (16th Edition):
Gouvêa, Carlos Alberto Rodrigues de. “Desenvolvimento de laminador para confecção de fios ortodônticos retangulares e suas caracterizações.” 2008. Masters Thesis, University of São Paulo. Accessed April 19, 2021.
http://www.teses.usp.br/teses/disponiveis/88/88131/tde-14052010-172628/.
MLA Handbook (7th Edition):
Gouvêa, Carlos Alberto Rodrigues de. “Desenvolvimento de laminador para confecção de fios ortodônticos retangulares e suas caracterizações.” 2008. Web. 19 Apr 2021.
Vancouver:
Gouvêa CARd. Desenvolvimento de laminador para confecção de fios ortodônticos retangulares e suas caracterizações. [Internet] [Masters thesis]. University of São Paulo; 2008. [cited 2021 Apr 19].
Available from: http://www.teses.usp.br/teses/disponiveis/88/88131/tde-14052010-172628/.
Council of Science Editors:
Gouvêa CARd. Desenvolvimento de laminador para confecção de fios ortodônticos retangulares e suas caracterizações. [Masters Thesis]. University of São Paulo; 2008. Available from: http://www.teses.usp.br/teses/disponiveis/88/88131/tde-14052010-172628/
24.
Quintão, Ana Paula Abdo.
Avaliação da quantidade de movimentação dentária com fios de níquel-titânio e aço multifilamentado na fase inicial de tratamento ortodôntico com aparelho fixo.
Degree: 2017, Universidade Federal de Juiz de Fora (UFJF); Programa de Pós-graduação em Saúde Brasileira; UFJF; Brasil; Faculdade de Medicina
URL: https://repositorio.ufjf.br/jspui/handle/ufjf/4497
► Este ensaio clínico retrospectivo randomizado longitudinal teve como objetivo comparar a eficácia clínica de duas ligas diferentes de fios ortodônticos (0,016 "de níquel-titânio e 0,0155"…
(more)
▼ Este ensaio clínico retrospectivo randomizado longitudinal teve como objetivo comparar a eficácia clínica de duas ligas diferentes de fios ortodônticos (0,016 "de níquel-titânio e 0,0155" coaxial multifilamentado, utilizados para o alinhamento e nivelamento dos dentes durante 6 semanas. Avaliou-se também a quantidade de movimentação tridimensional. A tecnologia digital tem sido amplamente utilizada em modelos de gesso tridimensionais. Entretanto, há um pequeno número de ensaios clínicos. Métodos: A amostra foi composta por dois grupos de modelos de gesso obtidos de 12 pacientes jovens cada, incluindo ambos os maxilares, superior e inferior, dos pacientes. Os moldes foram digitalizados, com o escâner Maestro 3D, em dois tempos diferentes de tratamento: T1, antes da colocação do fio; e T2, 8 semanas após a sua colocação, totalizando 96 imagens digitalizadas. O programa Geometric Qualify foi utilizado para superposição de maxilares superiores e
inferiores. Usando as rugas palatinas como ponto fixo para superposição das arcadas superiores, um método utilizando os modelos em oclusão foi criado pra transferir um ponto fixo das arcadas superiores para as arcadas inferiores, permitindo também, a superposição das mesmas. A quantidade precisa de movimento gerada por cada tipo de fio foi medida e visualizada através do programa CMF Application, usando linhas de contorno e mapas coloridos como ferramentas. Resultados: O fio 0,016" níquel-titânio promoveu maior quantidade de movimento dentário, que foi estatisticamente significativa, utilizando o teste de Mann-Whitney U (p <0,05). Conclusão: Os fios de níquel-titânio promoveram maior quantidade de movimentação dentária do que os fios de aço inoxidável multifilamentado.
This longitudinal retrospective randomized clinical trial aimed to compare the clinical effectiveness of two different orthodontic alloy wires (.016” nickel-titanium and .0155“ multistranded coaxial) used
for dental alignment and leveling during 6 weeks. The amount of tridimensional movement was also evaluated. Digital technology has been widely used in three-dimensional dental casts. Therefore, there are a short number of clinical trials. Methods: The sample was composed by two groups of 12 young patients’ casts of both upper and lower jaws. The casts were digitalized, with Maestro 3D scanner, in two different times of treatment: T1 was before the wire was placed and T2 was 8 weeks after its placement, in a total of 96 jaw digitalized images. Geometric Qualify Software was used to generate the superimposition of upper and lower jaws. Using the palatal ruggaes as a fixed point for superimposition of the upper jaw, a method using it and the models in occlusion was created to transfer a fixed point to the lower jaws, allowing its superimposition as well. The precise quantity of movement generated by each type of wire was measured and visualized through CMF Application software by using
isolines and color maps tools. Results: The .016" nickeltitanium wire promoted greater amount of tooth movement, which was…
Advisors/Committee Members: Vitral, Robert Willer Farinazzo, Carvalho, Felipe de Assis Ribeiro, Campos, Marcio José da Silva.
Subjects/Keywords: CNPQ::CIENCIAS DA SAUDE::MEDICINA; Modelos dentários digitais; Imagem tridimensional; Fios ortodônticos; Digital models; Three dimensional imaging; Orthodontic wires
Record Details
Similar Records
Cite
Share »
Record Details
Similar Records
Cite
« Share





❌
APA ·
Chicago ·
MLA ·
Vancouver ·
CSE |
Export
to Zotero / EndNote / Reference
Manager
APA (6th Edition):
Quintão, A. P. A. (2017). Avaliação da quantidade de movimentação dentária com fios de níquel-titânio e aço multifilamentado na fase inicial de tratamento ortodôntico com aparelho fixo. (Masters Thesis). Universidade Federal de Juiz de Fora (UFJF); Programa de Pós-graduação em Saúde Brasileira; UFJF; Brasil; Faculdade de Medicina. Retrieved from https://repositorio.ufjf.br/jspui/handle/ufjf/4497
Chicago Manual of Style (16th Edition):
Quintão, Ana Paula Abdo. “Avaliação da quantidade de movimentação dentária com fios de níquel-titânio e aço multifilamentado na fase inicial de tratamento ortodôntico com aparelho fixo.” 2017. Masters Thesis, Universidade Federal de Juiz de Fora (UFJF); Programa de Pós-graduação em Saúde Brasileira; UFJF; Brasil; Faculdade de Medicina. Accessed April 19, 2021.
https://repositorio.ufjf.br/jspui/handle/ufjf/4497.
MLA Handbook (7th Edition):
Quintão, Ana Paula Abdo. “Avaliação da quantidade de movimentação dentária com fios de níquel-titânio e aço multifilamentado na fase inicial de tratamento ortodôntico com aparelho fixo.” 2017. Web. 19 Apr 2021.
Vancouver:
Quintão APA. Avaliação da quantidade de movimentação dentária com fios de níquel-titânio e aço multifilamentado na fase inicial de tratamento ortodôntico com aparelho fixo. [Internet] [Masters thesis]. Universidade Federal de Juiz de Fora (UFJF); Programa de Pós-graduação em Saúde Brasileira; UFJF; Brasil; Faculdade de Medicina; 2017. [cited 2021 Apr 19].
Available from: https://repositorio.ufjf.br/jspui/handle/ufjf/4497.
Council of Science Editors:
Quintão APA. Avaliação da quantidade de movimentação dentária com fios de níquel-titânio e aço multifilamentado na fase inicial de tratamento ortodôntico com aparelho fixo. [Masters Thesis]. Universidade Federal de Juiz de Fora (UFJF); Programa de Pós-graduação em Saúde Brasileira; UFJF; Brasil; Faculdade de Medicina; 2017. Available from: https://repositorio.ufjf.br/jspui/handle/ufjf/4497
25.
Cox, Stan C.
A comparative study of extraction treatment efficiency using conventional edgewise brackets and self-ligating brackets.
Degree: MS, 2008, University of Alabama – Birmingham
URL: http://contentdm.mhsl.uab.edu/u?/etd,278
► The purpose of the present study was to assess treatment efficiency of one selfligating bracket system (In-Ovation, GAC International, Bohemia, NY) compared to a conventional…
(more)
▼ The purpose of the present study was to assess treatment efficiency of one selfligating bracket system (In-Ovation, GAC International, Bohemia, NY) compared to a conventional ligating bracket system (Ovation, GAC International, Bohemia, NY) in extraction cases used in the same practice. Treatment duration, number of appointments, and number of arch wires used per patient were compared within one private orthodontic practice. The total sample size was 155 patients, 83 consecutively finished with conventionally-ligated Ovation brackets and 72 consecutively finished with In-Ovation self-ligating brackets. After applying the exclusion criteria, there were 68 patients in the self-ligated (SL) group and 79 patients in the conventionally-ligated (CL) group. Overall, significantly fewer total appointments and scheduled appointments were necessary to finish the SL patients compared to the CL patients. However, significantly more arch wires were needed to finish the SL patients compared to the CL patients. Following adjustment for age and gender, the number of total appointments and scheduled appointments remained significantly less while the number of arch wires remained significantly more between the groups of patients treated with the SL and CL brackets, respectively. These results do show that some practice management benefits may result from the use of self-ligating brackets
M.S.
v, 47 p. : digital, PDF file
Orthodontics
Dentistry
Friction
Treatment Efficiency
Self-ligating Brackets
Orthodontic
Inovation R Brackets
Active vs. Passive Ligation
UNRESTRICTED
Advisors/Committee Members: Sadowsky, P. Lionel, Jacobson, Alex <br>, Rahemtulla, Firoz.
Subjects/Keywords: Analysis of Variance < br>
Friction < br>
Orthodontic Brackets < br>
Orthodontic Wires < br>
Orthodontics, Corrective – methods
Tooth Extraction
Record Details
Similar Records
Cite
Share »
Record Details
Similar Records
Cite
« Share





❌
APA ·
Chicago ·
MLA ·
Vancouver ·
CSE |
Export
to Zotero / EndNote / Reference
Manager
APA (6th Edition):
Cox, S. C. (2008). A comparative study of extraction treatment efficiency using conventional edgewise brackets and self-ligating brackets. (Masters Thesis). University of Alabama – Birmingham. Retrieved from http://contentdm.mhsl.uab.edu/u?/etd,278
Chicago Manual of Style (16th Edition):
Cox, Stan C. “A comparative study of extraction treatment efficiency using conventional edgewise brackets and self-ligating brackets.” 2008. Masters Thesis, University of Alabama – Birmingham. Accessed April 19, 2021.
http://contentdm.mhsl.uab.edu/u?/etd,278.
MLA Handbook (7th Edition):
Cox, Stan C. “A comparative study of extraction treatment efficiency using conventional edgewise brackets and self-ligating brackets.” 2008. Web. 19 Apr 2021.
Vancouver:
Cox SC. A comparative study of extraction treatment efficiency using conventional edgewise brackets and self-ligating brackets. [Internet] [Masters thesis]. University of Alabama – Birmingham; 2008. [cited 2021 Apr 19].
Available from: http://contentdm.mhsl.uab.edu/u?/etd,278.
Council of Science Editors:
Cox SC. A comparative study of extraction treatment efficiency using conventional edgewise brackets and self-ligating brackets. [Masters Thesis]. University of Alabama – Birmingham; 2008. Available from: http://contentdm.mhsl.uab.edu/u?/etd,278
26.
Reddick, Chad R. (Chad Russell).
A comparative study of nonextraction treatment efficiency using conventional edgewise brackets and self-ligating brackets.
Degree: MS, 2007, University of Alabama – Birmingham
URL: http://contentdm.mhsl.uab.edu/u?/etd,466
► Although there is a long history of self-ligating brackets in orthodontics, their popularity has peaked in recent years. Many private practice orthodontists have begun using…
(more)
▼ Although there is a long history of self-ligating brackets in orthodontics, their
popularity has peaked in recent years. Many private practice orthodontists have begun
using these brackets because of perceived advantages they may offer. It is widely
believed that the design features of most self-ligating brackets produce less friction
between wire and bracket, faster archwire removal and ligation, better bracket
engagement, and improved oral hygiene. If self-ligating brackets truly offer these
benefits, their use may lead to more efficient treatment. The purpose of this study was to
evaluate the nonextraction treatment efficiency of one self-ligating bracket system (In-
Ovation™, GAC International, Bohemia, NY) versus conventional twin edgewise
brackets (Ovation™, GAC International, Bohemia, NY) used in the same practice.
Treatment duration, number of appointments, and number of archwires used per patient
were compared within one private orthodontic practice. The total sample included 120
patients consecutively finished with each bracket type. After exclusions, there were 75
patients in the self-ligating (SL) group and 70 patients in the conventionally-ligated (CL)
group. Overall, significantly fewer total appointments, scheduled appointments, and
archwires were necessary to finish the SL patients compared to the CL patients.
Following adjustment for age, gender, and Angle classification, scheduled appointments
was the only parameter that remained significantly different between bracket groups.
When the bracket types were separated by Angle classification, Class I SL patients
required significantly fewer total appointments, scheduled appointments, and archwires
than Class I CL patients. No statistical differences were found for Class II or Class III
patients for any efficiency measure. These results indicate that there is promise for selfligation
leading to more efficient orthodontic treatment. This study also suggests that
Class I cases benefit more from the advantages of this bracket design.
M.S.
vii, 75 p. : ill., digital, PDF file
Orthodontics
Dentistry
Nonextraction Treatment Efficiency Self-ligation Self-ligating Brackets
UNRESTRICTED
Advisors/Committee Members: Sadowsky, P. Lionel, Jasobson, Alex<br>McNeal, Sandre.
Subjects/Keywords: Office Visits<; br>; Orthodontic Brackets<; br>; Orthodontics, Corrective – instrumentation<; br>; Orthodontic Wires<; br>; Time Factors
Record Details
Similar Records
Cite
Share »
Record Details
Similar Records
Cite
« Share





❌
APA ·
Chicago ·
MLA ·
Vancouver ·
CSE |
Export
to Zotero / EndNote / Reference
Manager
APA (6th Edition):
Reddick, C. R. (. R. (2007). A comparative study of nonextraction treatment efficiency using conventional edgewise brackets and self-ligating brackets. (Masters Thesis). University of Alabama – Birmingham. Retrieved from http://contentdm.mhsl.uab.edu/u?/etd,466
Chicago Manual of Style (16th Edition):
Reddick, Chad R (Chad Russell). “A comparative study of nonextraction treatment efficiency using conventional edgewise brackets and self-ligating brackets.” 2007. Masters Thesis, University of Alabama – Birmingham. Accessed April 19, 2021.
http://contentdm.mhsl.uab.edu/u?/etd,466.
MLA Handbook (7th Edition):
Reddick, Chad R (Chad Russell). “A comparative study of nonextraction treatment efficiency using conventional edgewise brackets and self-ligating brackets.” 2007. Web. 19 Apr 2021.
Vancouver:
Reddick CR(R. A comparative study of nonextraction treatment efficiency using conventional edgewise brackets and self-ligating brackets. [Internet] [Masters thesis]. University of Alabama – Birmingham; 2007. [cited 2021 Apr 19].
Available from: http://contentdm.mhsl.uab.edu/u?/etd,466.
Council of Science Editors:
Reddick CR(R. A comparative study of nonextraction treatment efficiency using conventional edgewise brackets and self-ligating brackets. [Masters Thesis]. University of Alabama – Birmingham; 2007. Available from: http://contentdm.mhsl.uab.edu/u?/etd,466
27.
Ricardo Cesar Moresca.
"Estudo dos efeitos dos lacebacks ativos e passivos na biomecânica da fase de nivelamento utilizando-se a técnica MBT".
Degree: 2006, University of São Paulo
URL: http://www.teses.usp.br/teses/disponiveis/23/23133/tde-30082006-151221/
► O objetivo deste trabalho foi estudar os efeitos dos lacebacks ativos e passivos na biomecânica da fase de nivelamento, utilizando-se a técnica MBT. A amostra…
(more)
▼ O objetivo deste trabalho foi estudar os efeitos dos lacebacks ativos e passivos na biomecânica da fase de nivelamento, utilizando-se a técnica MBT. A amostra foi constituída de 29 sujeitos de pesquisa (22 do gênero feminino e 7 do gênero masculino), brasileiros, leucodermas e pardos, portadores de má oclusão de Classe I e com idade média de 15 anos e 5 meses. O tratamento ortodôntico foi planejado com as extrações dos primeiros pré-molares e, durante a fase estudada, foram empregados apenas fios de aço inoxidável (0.014", 0.016", 0.018", 0.020" e 0.019" x 0.025"). Os recursos de ancoragem utilizados para os arcos dentários superior e inferior foram, respectivamente, o aparelho extrabucal tipo IHG e o arco lingual fixo. De acordo com a indicação dos lacebacks, a amostra foi dividida em quatro grupos: grupo I 14 sujeitos que utilizaram lacebacks ativos no arco dentário superior; grupo II 9 sujeitos que utilizaram lacebacks passivos no arco
dentário superior; grupo III 19 sujeitos que utilizaram lacebacks ativos no arco dentário inferior e grupo IV 10 sujeitos que utilizaram lacebacks passivos no arco dentário inferior. Para cada indivíduo da amostra foram tomadas duas telerradiografias laterais, uma ao início e outra ao término da fase de nivelamento, com um intervalo médio de 21 meses. Os dados foram coletados utilizando-se o método cefalométrico computadorizado. Para a análise de erros, o método cefalométrico foi repetido em todos os sujeitos da amostra, pelo mesmo operador, com um intervalo mínimo de 15 dias entre as medidas. Os resultados indicaram que as variações observadas foram compatíveis com as estimativas de erros operacionais em estudos cefalométricos. Após a análise estatística e a interpretação dos resultados, verificou-se que, no grupo I, apenas a coroa do primeiro molar superior sofreu um movimento mesial e que tanto a coroa como a raiz do incisivo central superior apresentaram um movimento em
direção lingual. No entanto, as inclinações destes dentes não foram alteradas. No grupo II, o primeiro molar superior se manteve estável e somente a coroa do incisivo central superior se movimentou em direção lingual, produzindo uma rotação horária deste dente. No grupo III, observou-se uma mesialização, tanto da coroa como da raiz, e extrusão do primeiro molar inferior, enquanto a posição do incisivo central inferior permaneceu inalterada. As inclinações destes dentes também não foram alteradas. No grupo IV, verificou-se que nem o primeiro molar inferior nem o incisivo central inferior apresentaram variações no sentido ântero-posterior. Verticalmente, houve extrusão apenas do primeiro molar inferior.
The purpose of this study was to evaluate the effects of active and passive lacebacks in the biomechanics of the leveling phase, using the MBT technique. The sample was composed of 29 Brazilian subjects (22 female and 7 male), Caucasian, with Class I malocclusion and mean age of 15
years and 5 months. The orthodontic treatment was planned with the extraction of the first premolars, and the…
Advisors/Committee Members: Julio Wilson Vigorito, Guilherme dos Reis Pereira Janson, Alexandre Moro, Gladys Cristina Dominguez Rodriguez, Marco Antonio Scanavini.
Subjects/Keywords: aparelhos ortodônticos; bráquetes ortodônticos; fechamento de espaço ortodôntico; fios ortodônticos; movimentação dentária; ortodontia corretiva; corrective; orthodontic appliances; orthodontic brackets; orthodontic space closure; orthodontic wires; orthodontics; tooth movement
Record Details
Similar Records
Cite
Share »
Record Details
Similar Records
Cite
« Share





❌
APA ·
Chicago ·
MLA ·
Vancouver ·
CSE |
Export
to Zotero / EndNote / Reference
Manager
APA (6th Edition):
Moresca, R. C. (2006). "Estudo dos efeitos dos lacebacks ativos e passivos na biomecânica da fase de nivelamento utilizando-se a técnica MBT". (Doctoral Dissertation). University of São Paulo. Retrieved from http://www.teses.usp.br/teses/disponiveis/23/23133/tde-30082006-151221/
Chicago Manual of Style (16th Edition):
Moresca, Ricardo Cesar. “"Estudo dos efeitos dos lacebacks ativos e passivos na biomecânica da fase de nivelamento utilizando-se a técnica MBT".” 2006. Doctoral Dissertation, University of São Paulo. Accessed April 19, 2021.
http://www.teses.usp.br/teses/disponiveis/23/23133/tde-30082006-151221/.
MLA Handbook (7th Edition):
Moresca, Ricardo Cesar. “"Estudo dos efeitos dos lacebacks ativos e passivos na biomecânica da fase de nivelamento utilizando-se a técnica MBT".” 2006. Web. 19 Apr 2021.
Vancouver:
Moresca RC. "Estudo dos efeitos dos lacebacks ativos e passivos na biomecânica da fase de nivelamento utilizando-se a técnica MBT". [Internet] [Doctoral dissertation]. University of São Paulo; 2006. [cited 2021 Apr 19].
Available from: http://www.teses.usp.br/teses/disponiveis/23/23133/tde-30082006-151221/.
Council of Science Editors:
Moresca RC. "Estudo dos efeitos dos lacebacks ativos e passivos na biomecânica da fase de nivelamento utilizando-se a técnica MBT". [Doctoral Dissertation]. University of São Paulo; 2006. Available from: http://www.teses.usp.br/teses/disponiveis/23/23133/tde-30082006-151221/
28.
Yamakawa, Rachel M.
White Pigmented Atomic Layer Deposition Coatings on Orthodontic Archwires : Resistance to Sliding, Durability, and Corrosion.
Degree: MS, 2013, Oregon Health Sciences University
URL: doi:10.6083/M4TH8K1Z
;
http://digitalcommons.ohsu.edu/etd/3462
Subjects/Keywords: Orthodontic Wires; Friction; Dental Esthetics; Corrosion; Dentistry; Medicine and Health Sciences
Record Details
Similar Records
Cite
Share »
Record Details
Similar Records
Cite
« Share





❌
APA ·
Chicago ·
MLA ·
Vancouver ·
CSE |
Export
to Zotero / EndNote / Reference
Manager
APA (6th Edition):
Yamakawa, R. M. (2013). White Pigmented Atomic Layer Deposition Coatings on Orthodontic Archwires : Resistance to Sliding, Durability, and Corrosion. (Thesis). Oregon Health Sciences University. Retrieved from doi:10.6083/M4TH8K1Z ; http://digitalcommons.ohsu.edu/etd/3462
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
Chicago Manual of Style (16th Edition):
Yamakawa, Rachel M. “White Pigmented Atomic Layer Deposition Coatings on Orthodontic Archwires : Resistance to Sliding, Durability, and Corrosion.” 2013. Thesis, Oregon Health Sciences University. Accessed April 19, 2021.
doi:10.6083/M4TH8K1Z ; http://digitalcommons.ohsu.edu/etd/3462.
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
MLA Handbook (7th Edition):
Yamakawa, Rachel M. “White Pigmented Atomic Layer Deposition Coatings on Orthodontic Archwires : Resistance to Sliding, Durability, and Corrosion.” 2013. Web. 19 Apr 2021.
Vancouver:
Yamakawa RM. White Pigmented Atomic Layer Deposition Coatings on Orthodontic Archwires : Resistance to Sliding, Durability, and Corrosion. [Internet] [Thesis]. Oregon Health Sciences University; 2013. [cited 2021 Apr 19].
Available from: doi:10.6083/M4TH8K1Z ; http://digitalcommons.ohsu.edu/etd/3462.
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
Council of Science Editors:
Yamakawa RM. White Pigmented Atomic Layer Deposition Coatings on Orthodontic Archwires : Resistance to Sliding, Durability, and Corrosion. [Thesis]. Oregon Health Sciences University; 2013. Available from: doi:10.6083/M4TH8K1Z ; http://digitalcommons.ohsu.edu/etd/3462
Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Universidade do Estado do Rio de Janeiro
29.
Cristiane Canavarro Rodrigues Martins.
Propriedades mecânicas de fios estéticos obtidas em ensaios de tração.
Degree: Master, 2007, Universidade do Estado do Rio de Janeiro
URL: http://www.bdtd.uerj.br/tde_busca/arquivo.php?codArquivo=746
;
► O desenvolvimento de fios ortodônticos que associem a vantagem estética com as necessidades biomecânicas tem sido um dos objetivos na Ortodontia. A maioria dos fios…
(more)
▼ O desenvolvimento de fios ortodônticos que associem a vantagem estética com as necessidades biomecânicas tem sido um dos objetivos na Ortodontia. A maioria dos fios comercializados com finalidade estética são compostos por níquel-titânio (NiTi) com cobertura a base de teflon ou resina epoxídica. O objetivo deste trabalho foi avaliar, através de ensaios de tração, propriedades mecânicas dos fios ortodônticos estéticos, em relação aos de NiTi superelásticos tradicionais. Foram utilizados 36 fios ortodônticos de NiTi superelásticos, sendo 18 estéticos e 18 sem cobertura estética, de calibre 0,018, das marcas TP Orthodontics, GAC e Masel. Os três exemplares de cada grupo foram alongados até a ruptura, com velocidade de ensaio de 1 milímetro de estiramento por minuto, a fim de se obter os patamares constantes de ativação dos fios. Os ensaios foram realizados a uma temperatura de 37C, utilizando-se a máquina universal de ensaios Emic DL 10000 de 10 toneladas de capacidade, sendo utilizada uma célula de carga de 50 N (50 quilogramas). Os dados foram analisados estatisticamente aplicando-se a análise de variância (ANOVA), seguido pelo teste de Bonferroni. Os resultados mostraram que, de maneira geral, os fios não recobertos possuem cargas máximas de ruptura e cargas para atingir o patamar de ativação mais elevadas que os estéticos (p≤ 0,01), com exceção dos fios não recobertos da marca Masel que apresentam semelhança estatística com os estéticos da TP. O mesmo acontece com as cargas no início, em 2% e 4% de deformação nos patamares de ativação e desativação. Os fios estéticos apresentaram, nos testes de ruptura, extensão de patamares de ativação maiores (p≤ 0,01), sendo o mesmo observado nos testes de ativação e desativação com extensão dos patamares de carregamento e descarregamento mais elevados. Em relação à área sob as curvas de ativação não foi observada diferença estatística significativa entre os fios avaliados com exceção dos fios da marca TP não recobertos, que apresentaram valores mais elevados. A área sob as curvas de desativação apresentaram valores maiores para os fios GAC não recobertos e TP estéticos e não recobertos (estatisticamente semelhantes) e valores mais baixos para os fios GAC estéticos e Masel estéticos e não recobertos. Conclui-se que em relação às características mecânicas os fios estéticos apresentaram bom desempenho, superando em grande parte das avaliações as características dos fios não recobertos.
The development of orthodontic wires that offer esthetic advantage with biomechanical necessities has been one of the aims of Orthodontics. Most of the wires with esthetic purpose are made of nickel-titanium (NiTi) with Teflon or epoxy-resin coating. This studys aims were to evaluate, through stress-strain tests, mechanical properties of the esthetic orthodontic wires, comparing them to the traditional NiTi superelastic ones. 36 superelastic NiTi orthodontic wires 18 esthetic and 18 with no esthetic coating with a 0,018 caliber, from the brands TP Orthodontics, GAC e Masel were…
Advisors/Committee Members: Marco Antonio de Oliveira Almeida, Jonas Capelli Júnior, Cátia Cardoso Abdo Quintão, Carlos Nelson Elias, Luciane Macedo de Menezes.
Subjects/Keywords: Ortodontia; Fios ortodônticos; Propriedades físicas; Tração; Estética; Orthodontics; Orthodontic wires; Physical properties; Traction; Esthetics; ORTODONTIA; Odontologia Aspectos estéticos; Fios ortodônticos - Propriedades mecânicas; Resistência à tração
Record Details
Similar Records
Cite
Share »
Record Details
Similar Records
Cite
« Share





❌
APA ·
Chicago ·
MLA ·
Vancouver ·
CSE |
Export
to Zotero / EndNote / Reference
Manager
APA (6th Edition):
Martins, C. C. R. (2007). Propriedades mecânicas de fios estéticos obtidas em ensaios de tração. (Masters Thesis). Universidade do Estado do Rio de Janeiro. Retrieved from http://www.bdtd.uerj.br/tde_busca/arquivo.php?codArquivo=746 ;
Chicago Manual of Style (16th Edition):
Martins, Cristiane Canavarro Rodrigues. “Propriedades mecânicas de fios estéticos obtidas em ensaios de tração.” 2007. Masters Thesis, Universidade do Estado do Rio de Janeiro. Accessed April 19, 2021.
http://www.bdtd.uerj.br/tde_busca/arquivo.php?codArquivo=746 ;.
MLA Handbook (7th Edition):
Martins, Cristiane Canavarro Rodrigues. “Propriedades mecânicas de fios estéticos obtidas em ensaios de tração.” 2007. Web. 19 Apr 2021.
Vancouver:
Martins CCR. Propriedades mecânicas de fios estéticos obtidas em ensaios de tração. [Internet] [Masters thesis]. Universidade do Estado do Rio de Janeiro; 2007. [cited 2021 Apr 19].
Available from: http://www.bdtd.uerj.br/tde_busca/arquivo.php?codArquivo=746 ;.
Council of Science Editors:
Martins CCR. Propriedades mecânicas de fios estéticos obtidas em ensaios de tração. [Masters Thesis]. Universidade do Estado do Rio de Janeiro; 2007. Available from: http://www.bdtd.uerj.br/tde_busca/arquivo.php?codArquivo=746 ;
30.
Renata Sathler-Zanda.
Avaliação da deflexão elástica de fios ortodônticos de níquel-titânio, calibre 0,014.
Degree: 2012, University of São Paulo
URL: http://www.teses.usp.br/teses/disponiveis/25/25144/tde-05112012-215337/
► PROPOSIÇÃO: O objetivo desta pesquisa foi apresentar a magnitude e a constância das forças liberadas por fios ortodônticos de níquel-titânio, usados para a correção dos…
(more)
▼ PROPOSIÇÃO: O objetivo desta pesquisa foi apresentar a magnitude e a constância das forças liberadas por fios ortodônticos de níquel-titânio, usados para a correção dos apinhamentos dentários. Outro objetivo foi comparar os dois meios mais utilizados de avaliação da deflexão elástica destes fios: o teste de 3 pontos e o dispositivo de simulação clínica. MATERIAL E MÉTODOS: Foram avaliados 11 grupos de fios de liga predominantemente de níquel-titânio, calibre 0,014, de 6 marcas diferentes (Abzil convencional e termoativado; GAC convencional e termoativado; Morelli convencional e termoativado; Ormco CuNiTi; Orthometric convencional e termoativado e Orthosource convencional e termoativado), em teste de deflexão elástica, nas deflexões de 0,5; 1; 2 e 3mm. Uma máquina de ensaio universal INSTRON 3342, com célula de carga de 10N foi utilizada e, como protocolo, foi seguida a norma ISO 15.841. Para a análise estatística dos resultados foram utilizados os
testes: Kolmogorov-Smirnov, para conferir se havia normalidade; teste t independente, para comparação dos resultados do teste de 3 pontos e dos resultados do dispositivo; e o teste ANOVA seguido do teste de Tukey, para comparações entre grupos. RESULTADOS: Houve diferença estatística entre os resultados gerados pelo teste de 3 pontos e os gerados pelo dispositivo. Por ser o teste indicado pela norma ISO citada, somente os resultados do teste de 3 pontos foram considerados. Todos os fios estudados apresentaram pseudoelasticidade em uma faixa de variação de força de até 40cN. Os grupos Abzil convencional, GAC convencional, Morelli termoativado, Ormco CuNiTi e Orthometric convencional apresentaram força dentro de uma faixa considerada ótima para a indução da movimentação dentária (50cN-100cN). Os fios termoativados liberaram forças mais leves que seus pares convencionais. CONCLUSÕES: Dentre os grupos estudados, aqueles que apresentaram pseudoelasticidade, forças dentro de uma faixa
considerada ótima e homogeneidade de amostra, foram os grupos Morelli termoativado e Ormco CuNiTi.
OBJECTIVE: The purpose of this study was to present the magnitude and the constancy of the forces released by nickel-titanium orthodontic wires, used to treat dental crowding. Another purpose was to compare the most usual types of bending tests used to evaluate these wires: 3-point test and clinical simulation device. MATERIAL AND METHODS: Eleven groups of orthodontic nickel-titanium wires, caliber 0.014, of 6 different brands (Abzil conventional and heat-activated; GAC conventional and heat-activated; Morelli conventional and heat-activated; Ormco CuNiTi; Orthometric conventional and heat-activated and Orthosource conventional and heat-activated) were tested by bending test, at deflections of 0.5; 1; 2 and 3mm. A universal testing machine INSTRON 3342 with a 10N load cell was used and, in order to standardize the tests, the ISO 15.841 regulation was followed. Statistical analysis
was performed using the subsequent tests: Kolmogorov-Smirnov to verify normality; independent t test to compare…
Advisors/Committee Members: Marcos Roberto de Freitas, Daniela Gamba Garib Carreira, Adilson Luiz Ramos, Carlos Alberto Soufen, Celia Regina Maio Pinzan Vercelino.
Subjects/Keywords: Cobre; Elasticidade; Estudo comparativo; Fenômenos mecânicos; Fios ortodônticos; Níquel; Ortodontia; Titânio; Comparative study; Copper NiTi [supplementary concept]; Elasticity; Mechanical; Mechanical phenomena; Orthodontic wires; Orthodontics; Stress; Titanium nickelide [supplementary concept]
Record Details
Similar Records
Cite
Share »
Record Details
Similar Records
Cite
« Share





❌
APA ·
Chicago ·
MLA ·
Vancouver ·
CSE |
Export
to Zotero / EndNote / Reference
Manager
APA (6th Edition):
Sathler-Zanda, R. (2012). Avaliação da deflexão elástica de fios ortodônticos de níquel-titânio, calibre 0,014. (Doctoral Dissertation). University of São Paulo. Retrieved from http://www.teses.usp.br/teses/disponiveis/25/25144/tde-05112012-215337/
Chicago Manual of Style (16th Edition):
Sathler-Zanda, Renata. “Avaliação da deflexão elástica de fios ortodônticos de níquel-titânio, calibre 0,014.” 2012. Doctoral Dissertation, University of São Paulo. Accessed April 19, 2021.
http://www.teses.usp.br/teses/disponiveis/25/25144/tde-05112012-215337/.
MLA Handbook (7th Edition):
Sathler-Zanda, Renata. “Avaliação da deflexão elástica de fios ortodônticos de níquel-titânio, calibre 0,014.” 2012. Web. 19 Apr 2021.
Vancouver:
Sathler-Zanda R. Avaliação da deflexão elástica de fios ortodônticos de níquel-titânio, calibre 0,014. [Internet] [Doctoral dissertation]. University of São Paulo; 2012. [cited 2021 Apr 19].
Available from: http://www.teses.usp.br/teses/disponiveis/25/25144/tde-05112012-215337/.
Council of Science Editors:
Sathler-Zanda R. Avaliação da deflexão elástica de fios ortodônticos de níquel-titânio, calibre 0,014. [Doctoral Dissertation]. University of São Paulo; 2012. Available from: http://www.teses.usp.br/teses/disponiveis/25/25144/tde-05112012-215337/
◁ [1] [2] ▶
.