You searched for subject:(Nitinol). Showing records 1 – 30 of 119 total matches.

[1] [2] [3] [4]

Search Limiters

Last 2 Years | English Only

Degrees

Levels

Languages

Country

▼ Search Limiters


Texas A&M University

1. Wells, Stephen Lee. Microdrilling of Nitinol.

Degree: MS, Mechanical Engineering, 2013, Texas A&M University

Nitinol, a shape memory alloy, has seen increased use in a variety of industries, especially the medical industry due to its biocompatibility. The growing demand… (more)

Subjects/Keywords: Micromachining; microdrilling; nitinol

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Wells, S. L. (2013). Microdrilling of Nitinol. (Masters Thesis). Texas A&M University. Retrieved from http://hdl.handle.net/1969.1/151761

Chicago Manual of Style (16th Edition):

Wells, Stephen Lee. “Microdrilling of Nitinol.” 2013. Masters Thesis, Texas A&M University. Accessed October 30, 2020. http://hdl.handle.net/1969.1/151761.

MLA Handbook (7th Edition):

Wells, Stephen Lee. “Microdrilling of Nitinol.” 2013. Web. 30 Oct 2020.

Vancouver:

Wells SL. Microdrilling of Nitinol. [Internet] [Masters thesis]. Texas A&M University; 2013. [cited 2020 Oct 30]. Available from: http://hdl.handle.net/1969.1/151761.

Council of Science Editors:

Wells SL. Microdrilling of Nitinol. [Masters Thesis]. Texas A&M University; 2013. Available from: http://hdl.handle.net/1969.1/151761


University of Waterloo

2. Khan, Mohammad Ibraheem. Pulsed Nd:YAG Laser Processing of Nitinol.

Degree: 2011, University of Waterloo

 The excellent pseudoelasticity, shape memory and biocompatibility of Nitinol have made it a leading candidate for applications in various fields, including aerospace, micro-electronics and medical… (more)

Subjects/Keywords: Nitinol; Laser Processing

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Khan, M. I. (2011). Pulsed Nd:YAG Laser Processing of Nitinol. (Thesis). University of Waterloo. Retrieved from http://hdl.handle.net/10012/5829

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Khan, Mohammad Ibraheem. “Pulsed Nd:YAG Laser Processing of Nitinol.” 2011. Thesis, University of Waterloo. Accessed October 30, 2020. http://hdl.handle.net/10012/5829.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Khan, Mohammad Ibraheem. “Pulsed Nd:YAG Laser Processing of Nitinol.” 2011. Web. 30 Oct 2020.

Vancouver:

Khan MI. Pulsed Nd:YAG Laser Processing of Nitinol. [Internet] [Thesis]. University of Waterloo; 2011. [cited 2020 Oct 30]. Available from: http://hdl.handle.net/10012/5829.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Khan MI. Pulsed Nd:YAG Laser Processing of Nitinol. [Thesis]. University of Waterloo; 2011. Available from: http://hdl.handle.net/10012/5829

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Delft University of Technology

3. Cuschieri, M. (author). Nitinol Drug Eluting Surfaces for Coronary Stents.

Degree: 2012, Delft University of Technology

Nowadays, drug eluting stents (DES) are the treatment of choice for de novo atherosclerotic lesions. Novel DES are shifting to polymer-free (PF) drug delivery in… (more)

Subjects/Keywords: Nitinol; Drug Elution; PEO

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Cuschieri, M. (. (2012). Nitinol Drug Eluting Surfaces for Coronary Stents. (Masters Thesis). Delft University of Technology. Retrieved from http://resolver.tudelft.nl/uuid:c2980ed5-fcfb-4c25-813f-99308e66b773

Chicago Manual of Style (16th Edition):

Cuschieri, M (author). “Nitinol Drug Eluting Surfaces for Coronary Stents.” 2012. Masters Thesis, Delft University of Technology. Accessed October 30, 2020. http://resolver.tudelft.nl/uuid:c2980ed5-fcfb-4c25-813f-99308e66b773.

MLA Handbook (7th Edition):

Cuschieri, M (author). “Nitinol Drug Eluting Surfaces for Coronary Stents.” 2012. Web. 30 Oct 2020.

Vancouver:

Cuschieri M(. Nitinol Drug Eluting Surfaces for Coronary Stents. [Internet] [Masters thesis]. Delft University of Technology; 2012. [cited 2020 Oct 30]. Available from: http://resolver.tudelft.nl/uuid:c2980ed5-fcfb-4c25-813f-99308e66b773.

Council of Science Editors:

Cuschieri M(. Nitinol Drug Eluting Surfaces for Coronary Stents. [Masters Thesis]. Delft University of Technology; 2012. Available from: http://resolver.tudelft.nl/uuid:c2980ed5-fcfb-4c25-813f-99308e66b773


Ruhr Universität Bochum

4. Habijan, Tim. Kultivierung von humanen mesenchymalen Stammzellen auf Nickel-Titan-Formgedächtnislegierungen.

Degree: 2009, Ruhr Universität Bochum

 Nickel-Titan-Formgedächtnislegierungen (NiTi-FGL) sind aufgrund ihrer mechanischen Eigenschaften viel versprechende Biomaterialien. Kritisch ist der hohe Nickelgehalt des Materials von 50 at%. Ziel dieser Arbeit war es,… (more)

Subjects/Keywords: Adulte Stammzelle; Biomaterial; Nickel / Kontaktallergie; Nitinol; Implantatwerkstoff

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Habijan, T. (2009). Kultivierung von humanen mesenchymalen Stammzellen auf Nickel-Titan-Formgedächtnislegierungen. (Thesis). Ruhr Universität Bochum. Retrieved from http://nbn-resolving.de/urn/resolver.pl?urn=urn:nbn:de:hbz:294-27207

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Habijan, Tim. “Kultivierung von humanen mesenchymalen Stammzellen auf Nickel-Titan-Formgedächtnislegierungen.” 2009. Thesis, Ruhr Universität Bochum. Accessed October 30, 2020. http://nbn-resolving.de/urn/resolver.pl?urn=urn:nbn:de:hbz:294-27207.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Habijan, Tim. “Kultivierung von humanen mesenchymalen Stammzellen auf Nickel-Titan-Formgedächtnislegierungen.” 2009. Web. 30 Oct 2020.

Vancouver:

Habijan T. Kultivierung von humanen mesenchymalen Stammzellen auf Nickel-Titan-Formgedächtnislegierungen. [Internet] [Thesis]. Ruhr Universität Bochum; 2009. [cited 2020 Oct 30]. Available from: http://nbn-resolving.de/urn/resolver.pl?urn=urn:nbn:de:hbz:294-27207.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Habijan T. Kultivierung von humanen mesenchymalen Stammzellen auf Nickel-Titan-Formgedächtnislegierungen. [Thesis]. Ruhr Universität Bochum; 2009. Available from: http://nbn-resolving.de/urn/resolver.pl?urn=urn:nbn:de:hbz:294-27207

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Mississippi State University

5. Stranburg, Tyler Nicholas. Assessment of Nitinol-based Arch Wedge Support through Finite Element Analysis.

Degree: MS, Mechanical Engineering, 2017, Mississippi State University

 This study proposes a nitinol-based thin-walled arch wedge support (AWS) and validated its performance in shock absorbing by using finite element analysis (FEA) method. Five… (more)

Subjects/Keywords: arch wedge support; nitinol; Additive manufacturing

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Stranburg, T. N. (2017). Assessment of Nitinol-based Arch Wedge Support through Finite Element Analysis. (Masters Thesis). Mississippi State University. Retrieved from http://sun.library.msstate.edu/ETD-db/theses/available/etd-10272017-103300/ ;

Chicago Manual of Style (16th Edition):

Stranburg, Tyler Nicholas. “Assessment of Nitinol-based Arch Wedge Support through Finite Element Analysis.” 2017. Masters Thesis, Mississippi State University. Accessed October 30, 2020. http://sun.library.msstate.edu/ETD-db/theses/available/etd-10272017-103300/ ;.

MLA Handbook (7th Edition):

Stranburg, Tyler Nicholas. “Assessment of Nitinol-based Arch Wedge Support through Finite Element Analysis.” 2017. Web. 30 Oct 2020.

Vancouver:

Stranburg TN. Assessment of Nitinol-based Arch Wedge Support through Finite Element Analysis. [Internet] [Masters thesis]. Mississippi State University; 2017. [cited 2020 Oct 30]. Available from: http://sun.library.msstate.edu/ETD-db/theses/available/etd-10272017-103300/ ;.

Council of Science Editors:

Stranburg TN. Assessment of Nitinol-based Arch Wedge Support through Finite Element Analysis. [Masters Thesis]. Mississippi State University; 2017. Available from: http://sun.library.msstate.edu/ETD-db/theses/available/etd-10272017-103300/ ;


San Jose State University

6. Bazochaharbakhsh, Edin. Surface Nitriding and Oxidation of Nitinol.

Degree: MS, Chemical and Materials Engineering, 2011, San Jose State University

Nitinol has been widely employed in biomedical devices due to its unique mechanical properties such as superelasticity, shape memory, and good biocompatibility. However, nickel… (more)

Subjects/Keywords: Nitinol; Nitriding; Oxidation; Surface Treatment; XPS

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Bazochaharbakhsh, E. (2011). Surface Nitriding and Oxidation of Nitinol. (Masters Thesis). San Jose State University. Retrieved from https://doi.org/10.31979/etd.qcdw-m2th ; https://scholarworks.sjsu.edu/etd_theses/4037

Chicago Manual of Style (16th Edition):

Bazochaharbakhsh, Edin. “Surface Nitriding and Oxidation of Nitinol.” 2011. Masters Thesis, San Jose State University. Accessed October 30, 2020. https://doi.org/10.31979/etd.qcdw-m2th ; https://scholarworks.sjsu.edu/etd_theses/4037.

MLA Handbook (7th Edition):

Bazochaharbakhsh, Edin. “Surface Nitriding and Oxidation of Nitinol.” 2011. Web. 30 Oct 2020.

Vancouver:

Bazochaharbakhsh E. Surface Nitriding and Oxidation of Nitinol. [Internet] [Masters thesis]. San Jose State University; 2011. [cited 2020 Oct 30]. Available from: https://doi.org/10.31979/etd.qcdw-m2th ; https://scholarworks.sjsu.edu/etd_theses/4037.

Council of Science Editors:

Bazochaharbakhsh E. Surface Nitriding and Oxidation of Nitinol. [Masters Thesis]. San Jose State University; 2011. Available from: https://doi.org/10.31979/etd.qcdw-m2th ; https://scholarworks.sjsu.edu/etd_theses/4037


University of Toronto

7. Brooks, Robert Joseph. Design of Novel Endoscopic Suction Grasping and Superelastic Surgical Clips Based on a Novel Model of Thin Collagenous Tissue.

Degree: PhD, 2016, University of Toronto

 Current endoscopic manipulation and sealing techniques are ineffective at large puncture repair, fistula closure, and anastomosis in tubular organs. For manipulation, the working channel of… (more)

Subjects/Keywords: Endoscopic; Medical Devices; Nitinol; Surgery; 0548

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Brooks, R. J. (2016). Design of Novel Endoscopic Suction Grasping and Superelastic Surgical Clips Based on a Novel Model of Thin Collagenous Tissue. (Doctoral Dissertation). University of Toronto. Retrieved from http://hdl.handle.net/1807/72932

Chicago Manual of Style (16th Edition):

Brooks, Robert Joseph. “Design of Novel Endoscopic Suction Grasping and Superelastic Surgical Clips Based on a Novel Model of Thin Collagenous Tissue.” 2016. Doctoral Dissertation, University of Toronto. Accessed October 30, 2020. http://hdl.handle.net/1807/72932.

MLA Handbook (7th Edition):

Brooks, Robert Joseph. “Design of Novel Endoscopic Suction Grasping and Superelastic Surgical Clips Based on a Novel Model of Thin Collagenous Tissue.” 2016. Web. 30 Oct 2020.

Vancouver:

Brooks RJ. Design of Novel Endoscopic Suction Grasping and Superelastic Surgical Clips Based on a Novel Model of Thin Collagenous Tissue. [Internet] [Doctoral dissertation]. University of Toronto; 2016. [cited 2020 Oct 30]. Available from: http://hdl.handle.net/1807/72932.

Council of Science Editors:

Brooks RJ. Design of Novel Endoscopic Suction Grasping and Superelastic Surgical Clips Based on a Novel Model of Thin Collagenous Tissue. [Doctoral Dissertation]. University of Toronto; 2016. Available from: http://hdl.handle.net/1807/72932


Ruhr Universität Bochum

8. Fechte-Heinen, Rainer. Mikromechanische Modellierung von Formgedächtnismaterialien.

Degree: 2007, Ruhr Universität Bochum

 Die vorliegende Arbeit beschäftigt sich mit der energetischen Modellierung von Formgedächtnislegierungen. Die in phasentransformierenden Materialien durch Mikrostrukturausbildung erreichbare Verringerung der Energiedichte ist für mehr als… (more)

Subjects/Keywords: Nitinol / Einkristall; Nitinol / Polykristall; Memory-Effekt; Memory-Legierung; Laminat

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Fechte-Heinen, R. (2007). Mikromechanische Modellierung von Formgedächtnismaterialien. (Thesis). Ruhr Universität Bochum. Retrieved from http://nbn-resolving.de/urn/resolver.pl?urn=urn:nbn:de:hbz:294-19416

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Fechte-Heinen, Rainer. “Mikromechanische Modellierung von Formgedächtnismaterialien.” 2007. Thesis, Ruhr Universität Bochum. Accessed October 30, 2020. http://nbn-resolving.de/urn/resolver.pl?urn=urn:nbn:de:hbz:294-19416.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Fechte-Heinen, Rainer. “Mikromechanische Modellierung von Formgedächtnismaterialien.” 2007. Web. 30 Oct 2020.

Vancouver:

Fechte-Heinen R. Mikromechanische Modellierung von Formgedächtnismaterialien. [Internet] [Thesis]. Ruhr Universität Bochum; 2007. [cited 2020 Oct 30]. Available from: http://nbn-resolving.de/urn/resolver.pl?urn=urn:nbn:de:hbz:294-19416.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Fechte-Heinen R. Mikromechanische Modellierung von Formgedächtnismaterialien. [Thesis]. Ruhr Universität Bochum; 2007. Available from: http://nbn-resolving.de/urn/resolver.pl?urn=urn:nbn:de:hbz:294-19416

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Université de Grenoble

9. Do, Thanh Dung. Etude des liaisons entre éléments Nickel-Titane en vue d'élaboration de matériaux architecturés : réalisation, caractérisation, métallurgique et mécanique : Study the bonds between elements Nickel-Titan to produce architectured materials : realization, mechanical metallurgy characterization.

Degree: Docteur es, Matériaux, mécanique, génie civil, électrochimie, 2014, Université de Grenoble

Le SMA Nitinol est largement utilisé dans de nombreux domaines de recherche récemment ( astronautes, biomédical ) et la combinaison de leurs propriétés dans la… (more)

Subjects/Keywords: Alliage à mémoire de forme; Nitinol; Matériaux architecturés; Frittage; Soudage; Tube; Shape memory alloy; Nitinol; Architectured material; Sintering; Welding; Tube; 620

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Do, T. D. (2014). Etude des liaisons entre éléments Nickel-Titane en vue d'élaboration de matériaux architecturés : réalisation, caractérisation, métallurgique et mécanique : Study the bonds between elements Nickel-Titan to produce architectured materials : realization, mechanical metallurgy characterization. (Doctoral Dissertation). Université de Grenoble. Retrieved from http://www.theses.fr/2014GRENI022

Chicago Manual of Style (16th Edition):

Do, Thanh Dung. “Etude des liaisons entre éléments Nickel-Titane en vue d'élaboration de matériaux architecturés : réalisation, caractérisation, métallurgique et mécanique : Study the bonds between elements Nickel-Titan to produce architectured materials : realization, mechanical metallurgy characterization.” 2014. Doctoral Dissertation, Université de Grenoble. Accessed October 30, 2020. http://www.theses.fr/2014GRENI022.

MLA Handbook (7th Edition):

Do, Thanh Dung. “Etude des liaisons entre éléments Nickel-Titane en vue d'élaboration de matériaux architecturés : réalisation, caractérisation, métallurgique et mécanique : Study the bonds between elements Nickel-Titan to produce architectured materials : realization, mechanical metallurgy characterization.” 2014. Web. 30 Oct 2020.

Vancouver:

Do TD. Etude des liaisons entre éléments Nickel-Titane en vue d'élaboration de matériaux architecturés : réalisation, caractérisation, métallurgique et mécanique : Study the bonds between elements Nickel-Titan to produce architectured materials : realization, mechanical metallurgy characterization. [Internet] [Doctoral dissertation]. Université de Grenoble; 2014. [cited 2020 Oct 30]. Available from: http://www.theses.fr/2014GRENI022.

Council of Science Editors:

Do TD. Etude des liaisons entre éléments Nickel-Titane en vue d'élaboration de matériaux architecturés : réalisation, caractérisation, métallurgique et mécanique : Study the bonds between elements Nickel-Titan to produce architectured materials : realization, mechanical metallurgy characterization. [Doctoral Dissertation]. Université de Grenoble; 2014. Available from: http://www.theses.fr/2014GRENI022


Brno University of Technology

10. Josiek, Robert. Paměťové materiály: Memory Materials.

Degree: 2019, Brno University of Technology

 Currently, shape memory materials are very popular, especially intermetallic compounds NiTi. This alloy is very stable and corrosion resistant, but its production is very difficult… (more)

Subjects/Keywords: Paměťové materiály; SMA; NiTi; Nitinol; martenzitická transformace; TiNi; superelasticita; Shape memory alloys; SMA; NiTi; Nitinol; martensite transformation; TiNi; superelasticity

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Josiek, R. (2019). Paměťové materiály: Memory Materials. (Thesis). Brno University of Technology. Retrieved from http://hdl.handle.net/11012/1674

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Josiek, Robert. “Paměťové materiály: Memory Materials.” 2019. Thesis, Brno University of Technology. Accessed October 30, 2020. http://hdl.handle.net/11012/1674.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Josiek, Robert. “Paměťové materiály: Memory Materials.” 2019. Web. 30 Oct 2020.

Vancouver:

Josiek R. Paměťové materiály: Memory Materials. [Internet] [Thesis]. Brno University of Technology; 2019. [cited 2020 Oct 30]. Available from: http://hdl.handle.net/11012/1674.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Josiek R. Paměťové materiály: Memory Materials. [Thesis]. Brno University of Technology; 2019. Available from: http://hdl.handle.net/11012/1674

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Brno University of Technology

11. Rašner, Martin. Analýza smart materiálů: Analysis of Smart Materials.

Degree: 2019, Brno University of Technology

 The bachelor's thesis "Smart Materials Analysis" deals with the description of intelligent materials in the way of usability in technical practice. At first, the research… (more)

Subjects/Keywords: smart materiály; superelasticita; martenzitická transformace; Nitinol; tlumení; nelineární kmitání; smart materials; superelasticity; martensitic transformation; Nitinol; damping; non-linear oscillation

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Rašner, M. (2019). Analýza smart materiálů: Analysis of Smart Materials. (Thesis). Brno University of Technology. Retrieved from http://hdl.handle.net/11012/66750

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Rašner, Martin. “Analýza smart materiálů: Analysis of Smart Materials.” 2019. Thesis, Brno University of Technology. Accessed October 30, 2020. http://hdl.handle.net/11012/66750.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Rašner, Martin. “Analýza smart materiálů: Analysis of Smart Materials.” 2019. Web. 30 Oct 2020.

Vancouver:

Rašner M. Analýza smart materiálů: Analysis of Smart Materials. [Internet] [Thesis]. Brno University of Technology; 2019. [cited 2020 Oct 30]. Available from: http://hdl.handle.net/11012/66750.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Rašner M. Analýza smart materiálů: Analysis of Smart Materials. [Thesis]. Brno University of Technology; 2019. Available from: http://hdl.handle.net/11012/66750

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Brno University of Technology

12. Faltýnek, František. Zpracování měření mechanických charakteristik materiálů s tvarovou pamětí na bázi NiTi při cyklickém zatěžování tahem: Evaluation of mechanical characteristics of shape memory alloys under cyclic loading in tension.

Degree: 2019, Brno University of Technology

 This bachelor thesis „Evaluation of mechanical characteristics of Shape Memory Alloys under cyclic loading in tension“ is focused on fatigue of metal materials, especially fatigue… (more)

Subjects/Keywords: Únava materiálu; Nitinol; austenit; martenzit; fázová transformace; superelasticita; Material fatigue; Nitinol; Austenite; Martensite; phase transformation; superelasticity

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Faltýnek, F. (2019). Zpracování měření mechanických charakteristik materiálů s tvarovou pamětí na bázi NiTi při cyklickém zatěžování tahem: Evaluation of mechanical characteristics of shape memory alloys under cyclic loading in tension. (Thesis). Brno University of Technology. Retrieved from http://hdl.handle.net/11012/60268

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Faltýnek, František. “Zpracování měření mechanických charakteristik materiálů s tvarovou pamětí na bázi NiTi při cyklickém zatěžování tahem: Evaluation of mechanical characteristics of shape memory alloys under cyclic loading in tension.” 2019. Thesis, Brno University of Technology. Accessed October 30, 2020. http://hdl.handle.net/11012/60268.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Faltýnek, František. “Zpracování měření mechanických charakteristik materiálů s tvarovou pamětí na bázi NiTi při cyklickém zatěžování tahem: Evaluation of mechanical characteristics of shape memory alloys under cyclic loading in tension.” 2019. Web. 30 Oct 2020.

Vancouver:

Faltýnek F. Zpracování měření mechanických charakteristik materiálů s tvarovou pamětí na bázi NiTi při cyklickém zatěžování tahem: Evaluation of mechanical characteristics of shape memory alloys under cyclic loading in tension. [Internet] [Thesis]. Brno University of Technology; 2019. [cited 2020 Oct 30]. Available from: http://hdl.handle.net/11012/60268.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Faltýnek F. Zpracování měření mechanických charakteristik materiálů s tvarovou pamětí na bázi NiTi při cyklickém zatěžování tahem: Evaluation of mechanical characteristics of shape memory alloys under cyclic loading in tension. [Thesis]. Brno University of Technology; 2019. Available from: http://hdl.handle.net/11012/60268

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Texas – Austin

13. -2591-8160. Blossoming - the application of using the Nitinol alloy, - the shape memory wire.

Degree: MFA, Theatre, 2019, University of Texas – Austin

 In the multiple and huge costume field, any idea will be possible. Costume technicians operate multiple skills to represent the design from the costume designer.… (more)

Subjects/Keywords: Nitinol; Shape memory wire; Shape memory alloy; Nitinol alloy; Costume design; Costume technology; Theatre costume; Theatre costume design

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

-2591-8160. (2019). Blossoming - the application of using the Nitinol alloy, - the shape memory wire. (Masters Thesis). University of Texas – Austin. Retrieved from http://dx.doi.org/10.26153/tsw/3103

Note: this citation may be lacking information needed for this citation format:
Author name may be incomplete

Chicago Manual of Style (16th Edition):

-2591-8160. “Blossoming - the application of using the Nitinol alloy, - the shape memory wire.” 2019. Masters Thesis, University of Texas – Austin. Accessed October 30, 2020. http://dx.doi.org/10.26153/tsw/3103.

Note: this citation may be lacking information needed for this citation format:
Author name may be incomplete

MLA Handbook (7th Edition):

-2591-8160. “Blossoming - the application of using the Nitinol alloy, - the shape memory wire.” 2019. Web. 30 Oct 2020.

Note: this citation may be lacking information needed for this citation format:
Author name may be incomplete

Vancouver:

-2591-8160. Blossoming - the application of using the Nitinol alloy, - the shape memory wire. [Internet] [Masters thesis]. University of Texas – Austin; 2019. [cited 2020 Oct 30]. Available from: http://dx.doi.org/10.26153/tsw/3103.

Note: this citation may be lacking information needed for this citation format:
Author name may be incomplete

Council of Science Editors:

-2591-8160. Blossoming - the application of using the Nitinol alloy, - the shape memory wire. [Masters Thesis]. University of Texas – Austin; 2019. Available from: http://dx.doi.org/10.26153/tsw/3103

Note: this citation may be lacking information needed for this citation format:
Author name may be incomplete


Ruhr Universität Bochum

14. Bogdanski, Denise. Untersuchungen zur Biokompatibilität und Biofunktionalität von Implantatmaterialien am Beispiel von Nickel-Titan- Formgedächtnislegierungen.

Degree: 2005, Ruhr Universität Bochum

 Formgedächtnislegierungen (FGL) auf der Basis von Nickel-Titan (NiTi) weisen interessante Eigenschaften auf, die zu mehreren Anwendungen in der klinischen Medizin geführt haben. Der Einsatz von… (more)

Subjects/Keywords: Nitinol; Biokompatibilität; Biomaterial; Leukozyt; Cytokine

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Bogdanski, D. (2005). Untersuchungen zur Biokompatibilität und Biofunktionalität von Implantatmaterialien am Beispiel von Nickel-Titan- Formgedächtnislegierungen. (Thesis). Ruhr Universität Bochum. Retrieved from http://nbn-resolving.de/urn/resolver.pl?urn=urn:nbn:de:hbz:294-15212

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Bogdanski, Denise. “Untersuchungen zur Biokompatibilität und Biofunktionalität von Implantatmaterialien am Beispiel von Nickel-Titan- Formgedächtnislegierungen.” 2005. Thesis, Ruhr Universität Bochum. Accessed October 30, 2020. http://nbn-resolving.de/urn/resolver.pl?urn=urn:nbn:de:hbz:294-15212.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Bogdanski, Denise. “Untersuchungen zur Biokompatibilität und Biofunktionalität von Implantatmaterialien am Beispiel von Nickel-Titan- Formgedächtnislegierungen.” 2005. Web. 30 Oct 2020.

Vancouver:

Bogdanski D. Untersuchungen zur Biokompatibilität und Biofunktionalität von Implantatmaterialien am Beispiel von Nickel-Titan- Formgedächtnislegierungen. [Internet] [Thesis]. Ruhr Universität Bochum; 2005. [cited 2020 Oct 30]. Available from: http://nbn-resolving.de/urn/resolver.pl?urn=urn:nbn:de:hbz:294-15212.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Bogdanski D. Untersuchungen zur Biokompatibilität und Biofunktionalität von Implantatmaterialien am Beispiel von Nickel-Titan- Formgedächtnislegierungen. [Thesis]. Ruhr Universität Bochum; 2005. Available from: http://nbn-resolving.de/urn/resolver.pl?urn=urn:nbn:de:hbz:294-15212

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Universidade do Rio Grande do Sul

15. Nogueira, Ana Paula Gomes. Desenvolvimento de método para medição da força radial em endopróteses aórticas.

Degree: 2011, Universidade do Rio Grande do Sul

O desempenho das endopróteses vasculares está relacionado diretamente à sua força radial. Esta é uma importante propriedade mecânica destes dispositivos médicos, influenciada por características da… (more)

Subjects/Keywords: Radial force; Ensaios mecânicos; Engenharia biomédica; Endoprostheses; Nitinol

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Nogueira, A. P. G. (2011). Desenvolvimento de método para medição da força radial em endopróteses aórticas. (Thesis). Universidade do Rio Grande do Sul. Retrieved from http://hdl.handle.net/10183/76176

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Nogueira, Ana Paula Gomes. “Desenvolvimento de método para medição da força radial em endopróteses aórticas.” 2011. Thesis, Universidade do Rio Grande do Sul. Accessed October 30, 2020. http://hdl.handle.net/10183/76176.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Nogueira, Ana Paula Gomes. “Desenvolvimento de método para medição da força radial em endopróteses aórticas.” 2011. Web. 30 Oct 2020.

Vancouver:

Nogueira APG. Desenvolvimento de método para medição da força radial em endopróteses aórticas. [Internet] [Thesis]. Universidade do Rio Grande do Sul; 2011. [cited 2020 Oct 30]. Available from: http://hdl.handle.net/10183/76176.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Nogueira APG. Desenvolvimento de método para medição da força radial em endopróteses aórticas. [Thesis]. Universidade do Rio Grande do Sul; 2011. Available from: http://hdl.handle.net/10183/76176

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Temple University

16. Honarvar, Mohammad. THERMOMECHANICAL CHARACTERIZATION OF ONE-WAY SHAPE MEMORY NITINOL AS AN ACTUATOR FOR ACTIVE SURGICAL NEEDLE.

Degree: PhD, 2014, Temple University

Mechanical Engineering

Needle-based intervention insertion is one of the common surgical techniques used in many diagnostic and therapeutic percutaneous procedures. The success of such procedures… (more)

Subjects/Keywords: Materials Science; Mechanical engineering;

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Honarvar, M. (2014). THERMOMECHANICAL CHARACTERIZATION OF ONE-WAY SHAPE MEMORY NITINOL AS AN ACTUATOR FOR ACTIVE SURGICAL NEEDLE. (Doctoral Dissertation). Temple University. Retrieved from http://digital.library.temple.edu/u?/p245801coll10,301891

Chicago Manual of Style (16th Edition):

Honarvar, Mohammad. “THERMOMECHANICAL CHARACTERIZATION OF ONE-WAY SHAPE MEMORY NITINOL AS AN ACTUATOR FOR ACTIVE SURGICAL NEEDLE.” 2014. Doctoral Dissertation, Temple University. Accessed October 30, 2020. http://digital.library.temple.edu/u?/p245801coll10,301891.

MLA Handbook (7th Edition):

Honarvar, Mohammad. “THERMOMECHANICAL CHARACTERIZATION OF ONE-WAY SHAPE MEMORY NITINOL AS AN ACTUATOR FOR ACTIVE SURGICAL NEEDLE.” 2014. Web. 30 Oct 2020.

Vancouver:

Honarvar M. THERMOMECHANICAL CHARACTERIZATION OF ONE-WAY SHAPE MEMORY NITINOL AS AN ACTUATOR FOR ACTIVE SURGICAL NEEDLE. [Internet] [Doctoral dissertation]. Temple University; 2014. [cited 2020 Oct 30]. Available from: http://digital.library.temple.edu/u?/p245801coll10,301891.

Council of Science Editors:

Honarvar M. THERMOMECHANICAL CHARACTERIZATION OF ONE-WAY SHAPE MEMORY NITINOL AS AN ACTUATOR FOR ACTIVE SURGICAL NEEDLE. [Doctoral Dissertation]. Temple University; 2014. Available from: http://digital.library.temple.edu/u?/p245801coll10,301891


Penn State University

17. Liu, Jiening. COMPLIANT MECHANISMS USING SUPERELASTIC NITINOL.

Degree: 2012, Penn State University

NiTiNOL which is a nickel and titanium alloy exhibits the superelastic effect at desired temperature so that it can provide large strain up to 10%… (more)

Subjects/Keywords: compliant mechanism; nitinol; superelastic modelling; NOTES; flapping wing

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Liu, J. (2012). COMPLIANT MECHANISMS USING SUPERELASTIC NITINOL. (Thesis). Penn State University. Retrieved from https://submit-etda.libraries.psu.edu/catalog/16139

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Liu, Jiening. “COMPLIANT MECHANISMS USING SUPERELASTIC NITINOL.” 2012. Thesis, Penn State University. Accessed October 30, 2020. https://submit-etda.libraries.psu.edu/catalog/16139.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Liu, Jiening. “COMPLIANT MECHANISMS USING SUPERELASTIC NITINOL.” 2012. Web. 30 Oct 2020.

Vancouver:

Liu J. COMPLIANT MECHANISMS USING SUPERELASTIC NITINOL. [Internet] [Thesis]. Penn State University; 2012. [cited 2020 Oct 30]. Available from: https://submit-etda.libraries.psu.edu/catalog/16139.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Liu J. COMPLIANT MECHANISMS USING SUPERELASTIC NITINOL. [Thesis]. Penn State University; 2012. Available from: https://submit-etda.libraries.psu.edu/catalog/16139

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Texas A&M University

18. Muschenborn, Andrea Denise. Shape Memory Neuroendovascular Medical Devices for the Treatment and Prevention of Stroke.

Degree: PhD, Biomedical Engineering, 2013, Texas A&M University

 Stroke is a cardiovascular disease that results in the abnormal blood supply to the brain either by the lack thereof (i.e., ischemia), or hemorrhage, both… (more)

Subjects/Keywords: Thrombectomy; Shape memory polymer (SMP) foam; Porous media properties; Nitinol

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Muschenborn, A. D. (2013). Shape Memory Neuroendovascular Medical Devices for the Treatment and Prevention of Stroke. (Doctoral Dissertation). Texas A&M University. Retrieved from http://hdl.handle.net/1969.1/156353

Chicago Manual of Style (16th Edition):

Muschenborn, Andrea Denise. “Shape Memory Neuroendovascular Medical Devices for the Treatment and Prevention of Stroke.” 2013. Doctoral Dissertation, Texas A&M University. Accessed October 30, 2020. http://hdl.handle.net/1969.1/156353.

MLA Handbook (7th Edition):

Muschenborn, Andrea Denise. “Shape Memory Neuroendovascular Medical Devices for the Treatment and Prevention of Stroke.” 2013. Web. 30 Oct 2020.

Vancouver:

Muschenborn AD. Shape Memory Neuroendovascular Medical Devices for the Treatment and Prevention of Stroke. [Internet] [Doctoral dissertation]. Texas A&M University; 2013. [cited 2020 Oct 30]. Available from: http://hdl.handle.net/1969.1/156353.

Council of Science Editors:

Muschenborn AD. Shape Memory Neuroendovascular Medical Devices for the Treatment and Prevention of Stroke. [Doctoral Dissertation]. Texas A&M University; 2013. Available from: http://hdl.handle.net/1969.1/156353


Brigham Young University

19. Dearden, Jason Lon. Design and Analysis of Two Compliant Mechanism Designs for Use in Minimally Invasive Surgical Instruments.

Degree: MA, 2016, Brigham Young University

 Minimally invasive surgery (MIS) has several advantages over traditional methods. Scaling MIS instruments to smaller sizes and increasing their performance will enable surgeons to offer… (more)

Subjects/Keywords: compliant mechanism; minimally invasive surgery; cross-axis flexural pivot; nitinol

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Dearden, J. L. (2016). Design and Analysis of Two Compliant Mechanism Designs for Use in Minimally Invasive Surgical Instruments. (Masters Thesis). Brigham Young University. Retrieved from https://scholarsarchive.byu.edu/cgi/viewcontent.cgi?article=8383&context=etd

Chicago Manual of Style (16th Edition):

Dearden, Jason Lon. “Design and Analysis of Two Compliant Mechanism Designs for Use in Minimally Invasive Surgical Instruments.” 2016. Masters Thesis, Brigham Young University. Accessed October 30, 2020. https://scholarsarchive.byu.edu/cgi/viewcontent.cgi?article=8383&context=etd.

MLA Handbook (7th Edition):

Dearden, Jason Lon. “Design and Analysis of Two Compliant Mechanism Designs for Use in Minimally Invasive Surgical Instruments.” 2016. Web. 30 Oct 2020.

Vancouver:

Dearden JL. Design and Analysis of Two Compliant Mechanism Designs for Use in Minimally Invasive Surgical Instruments. [Internet] [Masters thesis]. Brigham Young University; 2016. [cited 2020 Oct 30]. Available from: https://scholarsarchive.byu.edu/cgi/viewcontent.cgi?article=8383&context=etd.

Council of Science Editors:

Dearden JL. Design and Analysis of Two Compliant Mechanism Designs for Use in Minimally Invasive Surgical Instruments. [Masters Thesis]. Brigham Young University; 2016. Available from: https://scholarsarchive.byu.edu/cgi/viewcontent.cgi?article=8383&context=etd

20. MCEVOY, JAAKKO. Adaptive Liquid Cooling Methods in Microchannel Heat Sinks.

Degree: School of Engineering. Discipline of Mechanical & Manuf. Eng, 2020, Trinity College Dublin

 This work investigates the effect of implementing three varying cooling techniques for high heat flux electronics cooling. High heat fluxes are being experienced in data… (more)

Subjects/Keywords: pulsatile flow; adaptive cooling; nitinol; electronics cooling; micro-PIV; CFD

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

MCEVOY, J. (2020). Adaptive Liquid Cooling Methods in Microchannel Heat Sinks. (Thesis). Trinity College Dublin. Retrieved from http://hdl.handle.net/2262/92752

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

MCEVOY, JAAKKO. “Adaptive Liquid Cooling Methods in Microchannel Heat Sinks.” 2020. Thesis, Trinity College Dublin. Accessed October 30, 2020. http://hdl.handle.net/2262/92752.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

MCEVOY, JAAKKO. “Adaptive Liquid Cooling Methods in Microchannel Heat Sinks.” 2020. Web. 30 Oct 2020.

Vancouver:

MCEVOY J. Adaptive Liquid Cooling Methods in Microchannel Heat Sinks. [Internet] [Thesis]. Trinity College Dublin; 2020. [cited 2020 Oct 30]. Available from: http://hdl.handle.net/2262/92752.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

MCEVOY J. Adaptive Liquid Cooling Methods in Microchannel Heat Sinks. [Thesis]. Trinity College Dublin; 2020. Available from: http://hdl.handle.net/2262/92752

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

21. Al-abassi, Amatulraheem. FINITE ELEMENT ANALYSIS OF SHAPE MEMORY ALLOY NiTi STENT IN CORONARY ARTERY.

Degree: MS, School of Engineering, 2017, University of Guelph

 The coronary artery stent is a medical device that treats different coronary diseases. Though in the long run, there is a threat of restenosis, stent… (more)

Subjects/Keywords: Nitinol Stent; Coronary Artery

…13 Figure5: Stress vs. strain curve, representing the Nitinol phase transformation, Qiu… …x5B;40]. ............. 15 Figure6: The strain range for superelastic Nitinol compared… …30 Figure 11: The meshing sensitivity test plot for the stress of Nitinol stent in… …strain of Nitinol stent, 0.00152, at 36.5˚C and normal MAP. b) Presents the maximum strain… …of Nitinol stent, 0.00184, at 40.0˚C and normal MAP… 

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Al-abassi, A. (2017). FINITE ELEMENT ANALYSIS OF SHAPE MEMORY ALLOY NiTi STENT IN CORONARY ARTERY. (Masters Thesis). University of Guelph. Retrieved from https://atrium.lib.uoguelph.ca/xmlui/handle/10214/11923

Chicago Manual of Style (16th Edition):

Al-abassi, Amatulraheem. “FINITE ELEMENT ANALYSIS OF SHAPE MEMORY ALLOY NiTi STENT IN CORONARY ARTERY.” 2017. Masters Thesis, University of Guelph. Accessed October 30, 2020. https://atrium.lib.uoguelph.ca/xmlui/handle/10214/11923.

MLA Handbook (7th Edition):

Al-abassi, Amatulraheem. “FINITE ELEMENT ANALYSIS OF SHAPE MEMORY ALLOY NiTi STENT IN CORONARY ARTERY.” 2017. Web. 30 Oct 2020.

Vancouver:

Al-abassi A. FINITE ELEMENT ANALYSIS OF SHAPE MEMORY ALLOY NiTi STENT IN CORONARY ARTERY. [Internet] [Masters thesis]. University of Guelph; 2017. [cited 2020 Oct 30]. Available from: https://atrium.lib.uoguelph.ca/xmlui/handle/10214/11923.

Council of Science Editors:

Al-abassi A. FINITE ELEMENT ANALYSIS OF SHAPE MEMORY ALLOY NiTi STENT IN CORONARY ARTERY. [Masters Thesis]. University of Guelph; 2017. Available from: https://atrium.lib.uoguelph.ca/xmlui/handle/10214/11923

22. 김, 태희. Long-term patency of nitinol stent placement in dysfunctional hemodialysis.

Degree: 2012, Ajou University

Purpose: To evaluate the long-term patency of stents placement on dysfunctional hemodialysis shunt after failed balloon angioplasty and analysis the factors affecting the patency of… (more)

Subjects/Keywords: nitinol stent; patency; cubital vein; stent fracture; stent migration

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

김, . (2012). Long-term patency of nitinol stent placement in dysfunctional hemodialysis. (Thesis). Ajou University. Retrieved from http://repository.ajou.ac.kr/handle/201003/7581 ; http://dcoll.ajou.ac.kr:9080/dcollection/jsp/common/DcLoOrgPer.jsp?sItemId=000000012103

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

김, 태희. “Long-term patency of nitinol stent placement in dysfunctional hemodialysis.” 2012. Thesis, Ajou University. Accessed October 30, 2020. http://repository.ajou.ac.kr/handle/201003/7581 ; http://dcoll.ajou.ac.kr:9080/dcollection/jsp/common/DcLoOrgPer.jsp?sItemId=000000012103.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

김, 태희. “Long-term patency of nitinol stent placement in dysfunctional hemodialysis.” 2012. Web. 30 Oct 2020.

Vancouver:

김 . Long-term patency of nitinol stent placement in dysfunctional hemodialysis. [Internet] [Thesis]. Ajou University; 2012. [cited 2020 Oct 30]. Available from: http://repository.ajou.ac.kr/handle/201003/7581 ; http://dcoll.ajou.ac.kr:9080/dcollection/jsp/common/DcLoOrgPer.jsp?sItemId=000000012103.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

김 . Long-term patency of nitinol stent placement in dysfunctional hemodialysis. [Thesis]. Ajou University; 2012. Available from: http://repository.ajou.ac.kr/handle/201003/7581 ; http://dcoll.ajou.ac.kr:9080/dcollection/jsp/common/DcLoOrgPer.jsp?sItemId=000000012103

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Colorado State University

23. Morrone, Adam. Novel design methodology for osseointegrated implants and the effects of heat-treatment on shape setting nitinol foil, A.

Degree: MS(M.S.), Mechanical Engineering, 2020, Colorado State University

Nitinol, approximately equiatomic nickel and titanium and a popular shape memory alloy, has been used extensively in modern, implantable medical devices due to its natural… (more)

Subjects/Keywords: heat-treatment; nitinol; osseointegration; NiTi; bone implants; OIP

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Morrone, A. (2020). Novel design methodology for osseointegrated implants and the effects of heat-treatment on shape setting nitinol foil, A. (Masters Thesis). Colorado State University. Retrieved from http://hdl.handle.net/10217/208444

Chicago Manual of Style (16th Edition):

Morrone, Adam. “Novel design methodology for osseointegrated implants and the effects of heat-treatment on shape setting nitinol foil, A.” 2020. Masters Thesis, Colorado State University. Accessed October 30, 2020. http://hdl.handle.net/10217/208444.

MLA Handbook (7th Edition):

Morrone, Adam. “Novel design methodology for osseointegrated implants and the effects of heat-treatment on shape setting nitinol foil, A.” 2020. Web. 30 Oct 2020.

Vancouver:

Morrone A. Novel design methodology for osseointegrated implants and the effects of heat-treatment on shape setting nitinol foil, A. [Internet] [Masters thesis]. Colorado State University; 2020. [cited 2020 Oct 30]. Available from: http://hdl.handle.net/10217/208444.

Council of Science Editors:

Morrone A. Novel design methodology for osseointegrated implants and the effects of heat-treatment on shape setting nitinol foil, A. [Masters Thesis]. Colorado State University; 2020. Available from: http://hdl.handle.net/10217/208444


Florida International University

24. Pulletikurthi, Chandan. Biocompatibility Assessment of Biosorbable Polymer Coated Nitinol Alloys.

Degree: PhD, Materials Science and Engineering, 2014, Florida International University

  Owing to an increased risk of aging population and a higher incidence of coronary artery disease (CAD), there is a need for more reliable… (more)

Subjects/Keywords: Biocompatibility; Hemocompatibility; Nitinol; Stents; In-vitro corrosion; bio-sorbable polymer; coatings

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Pulletikurthi, C. (2014). Biocompatibility Assessment of Biosorbable Polymer Coated Nitinol Alloys. (Doctoral Dissertation). Florida International University. Retrieved from https://digitalcommons.fiu.edu/etd/1552 ; 10.25148/etd.FI14071184 ; FI14071184

Chicago Manual of Style (16th Edition):

Pulletikurthi, Chandan. “Biocompatibility Assessment of Biosorbable Polymer Coated Nitinol Alloys.” 2014. Doctoral Dissertation, Florida International University. Accessed October 30, 2020. https://digitalcommons.fiu.edu/etd/1552 ; 10.25148/etd.FI14071184 ; FI14071184.

MLA Handbook (7th Edition):

Pulletikurthi, Chandan. “Biocompatibility Assessment of Biosorbable Polymer Coated Nitinol Alloys.” 2014. Web. 30 Oct 2020.

Vancouver:

Pulletikurthi C. Biocompatibility Assessment of Biosorbable Polymer Coated Nitinol Alloys. [Internet] [Doctoral dissertation]. Florida International University; 2014. [cited 2020 Oct 30]. Available from: https://digitalcommons.fiu.edu/etd/1552 ; 10.25148/etd.FI14071184 ; FI14071184.

Council of Science Editors:

Pulletikurthi C. Biocompatibility Assessment of Biosorbable Polymer Coated Nitinol Alloys. [Doctoral Dissertation]. Florida International University; 2014. Available from: https://digitalcommons.fiu.edu/etd/1552 ; 10.25148/etd.FI14071184 ; FI14071184

25. McGrath, Donnacha John. A computational and experimental investigation of tracheobronchial stent performance .

Degree: 2017, National University of Ireland – Galway

 Tracheobronchial stents are used to relieve blockages in the respiratory tree, typically caused by lung cancer. However, multiple complications can be associated with stents for… (more)

Subjects/Keywords: Biomedical engineering; Finite element; Nitinol stent; Tracheobronchial; Biomechanics

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

McGrath, D. J. (2017). A computational and experimental investigation of tracheobronchial stent performance . (Thesis). National University of Ireland – Galway. Retrieved from http://hdl.handle.net/10379/6951

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

McGrath, Donnacha John. “A computational and experimental investigation of tracheobronchial stent performance .” 2017. Thesis, National University of Ireland – Galway. Accessed October 30, 2020. http://hdl.handle.net/10379/6951.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

McGrath, Donnacha John. “A computational and experimental investigation of tracheobronchial stent performance .” 2017. Web. 30 Oct 2020.

Vancouver:

McGrath DJ. A computational and experimental investigation of tracheobronchial stent performance . [Internet] [Thesis]. National University of Ireland – Galway; 2017. [cited 2020 Oct 30]. Available from: http://hdl.handle.net/10379/6951.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

McGrath DJ. A computational and experimental investigation of tracheobronchial stent performance . [Thesis]. National University of Ireland – Galway; 2017. Available from: http://hdl.handle.net/10379/6951

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Delft University of Technology

26. Ridderbos, Marlike (author). An Instrument for Matching Defect and Implant Size in Matrix-induced Autologous Chondrocyte Implantation.

Degree: 2017, Delft University of Technology

Cartilage defects in the knee lead to limitations in the daily life of a large group of people in the worldwide population. Research on the… (more)

Subjects/Keywords: matrix autologous chondrocyte implantation; arthroscopy; nitinol; knee; instrument; MACI

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Ridderbos, M. (. (2017). An Instrument for Matching Defect and Implant Size in Matrix-induced Autologous Chondrocyte Implantation. (Masters Thesis). Delft University of Technology. Retrieved from http://resolver.tudelft.nl/uuid:0abab6e9-48d7-4411-aea7-c7d258fe4658

Chicago Manual of Style (16th Edition):

Ridderbos, Marlike (author). “An Instrument for Matching Defect and Implant Size in Matrix-induced Autologous Chondrocyte Implantation.” 2017. Masters Thesis, Delft University of Technology. Accessed October 30, 2020. http://resolver.tudelft.nl/uuid:0abab6e9-48d7-4411-aea7-c7d258fe4658.

MLA Handbook (7th Edition):

Ridderbos, Marlike (author). “An Instrument for Matching Defect and Implant Size in Matrix-induced Autologous Chondrocyte Implantation.” 2017. Web. 30 Oct 2020.

Vancouver:

Ridderbos M(. An Instrument for Matching Defect and Implant Size in Matrix-induced Autologous Chondrocyte Implantation. [Internet] [Masters thesis]. Delft University of Technology; 2017. [cited 2020 Oct 30]. Available from: http://resolver.tudelft.nl/uuid:0abab6e9-48d7-4411-aea7-c7d258fe4658.

Council of Science Editors:

Ridderbos M(. An Instrument for Matching Defect and Implant Size in Matrix-induced Autologous Chondrocyte Implantation. [Masters Thesis]. Delft University of Technology; 2017. Available from: http://resolver.tudelft.nl/uuid:0abab6e9-48d7-4411-aea7-c7d258fe4658


Delft University of Technology

27. Wong, Yu Feng (author). Design and Computational Modelling for a Shape Memory Alloy-based Adaptronic Architecture.

Degree: 2018, Delft University of Technology

In the EU, the heating and cooling of buildings consumes 14% of all energy. This is a major consumer for one type of activity, and… (more)

Subjects/Keywords: adaptive; Shape memory Alloy; adaptronic; computational; Facade; nitinol

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Wong, Y. F. (. (2018). Design and Computational Modelling for a Shape Memory Alloy-based Adaptronic Architecture. (Masters Thesis). Delft University of Technology. Retrieved from http://resolver.tudelft.nl/uuid:720bffe6-a991-45e9-b5c2-c662a96b0040

Chicago Manual of Style (16th Edition):

Wong, Yu Feng (author). “Design and Computational Modelling for a Shape Memory Alloy-based Adaptronic Architecture.” 2018. Masters Thesis, Delft University of Technology. Accessed October 30, 2020. http://resolver.tudelft.nl/uuid:720bffe6-a991-45e9-b5c2-c662a96b0040.

MLA Handbook (7th Edition):

Wong, Yu Feng (author). “Design and Computational Modelling for a Shape Memory Alloy-based Adaptronic Architecture.” 2018. Web. 30 Oct 2020.

Vancouver:

Wong YF(. Design and Computational Modelling for a Shape Memory Alloy-based Adaptronic Architecture. [Internet] [Masters thesis]. Delft University of Technology; 2018. [cited 2020 Oct 30]. Available from: http://resolver.tudelft.nl/uuid:720bffe6-a991-45e9-b5c2-c662a96b0040.

Council of Science Editors:

Wong YF(. Design and Computational Modelling for a Shape Memory Alloy-based Adaptronic Architecture. [Masters Thesis]. Delft University of Technology; 2018. Available from: http://resolver.tudelft.nl/uuid:720bffe6-a991-45e9-b5c2-c662a96b0040


University of Hawaii – Manoa

28. Bhawuk, Atma Prakash. Experimental analysis and theoretical modeling of forced mechanical response of nitinol stent for popliteal segment of femoral region.

Degree: 2016, University of Hawaii – Manoa

M.S. University of Hawaii at Manoa 2012.

Stents are small, wire-mesh struts that are placed into arteries after an angioplasty procedure. The purpose of a… (more)

Subjects/Keywords: nitinol stent; femoral region; popliteal segment; forced mechanical response

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Bhawuk, A. P. (2016). Experimental analysis and theoretical modeling of forced mechanical response of nitinol stent for popliteal segment of femoral region. (Thesis). University of Hawaii – Manoa. Retrieved from http://hdl.handle.net/10125/100933

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Bhawuk, Atma Prakash. “Experimental analysis and theoretical modeling of forced mechanical response of nitinol stent for popliteal segment of femoral region.” 2016. Thesis, University of Hawaii – Manoa. Accessed October 30, 2020. http://hdl.handle.net/10125/100933.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Bhawuk, Atma Prakash. “Experimental analysis and theoretical modeling of forced mechanical response of nitinol stent for popliteal segment of femoral region.” 2016. Web. 30 Oct 2020.

Vancouver:

Bhawuk AP. Experimental analysis and theoretical modeling of forced mechanical response of nitinol stent for popliteal segment of femoral region. [Internet] [Thesis]. University of Hawaii – Manoa; 2016. [cited 2020 Oct 30]. Available from: http://hdl.handle.net/10125/100933.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Bhawuk AP. Experimental analysis and theoretical modeling of forced mechanical response of nitinol stent for popliteal segment of femoral region. [Thesis]. University of Hawaii – Manoa; 2016. Available from: http://hdl.handle.net/10125/100933

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Duke University

29. Jantzen, Alexandra Elizabeth. Seeding of Titanium Surfaces and Nitinol Stents with Blood-Derived Endothelial Cells .

Degree: 2014, Duke University

  Covering the metal surface of blood-contacting cardiovascular implants (stents, ventricular assist devices) with functional endothelium may reduce the incidence of clotting and restenosis complications… (more)

Subjects/Keywords: Biomedical engineering; cardiology; endothelium; nitinol; restenosis; stent; titanium

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Jantzen, A. E. (2014). Seeding of Titanium Surfaces and Nitinol Stents with Blood-Derived Endothelial Cells . (Thesis). Duke University. Retrieved from http://hdl.handle.net/10161/8725

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Jantzen, Alexandra Elizabeth. “Seeding of Titanium Surfaces and Nitinol Stents with Blood-Derived Endothelial Cells .” 2014. Thesis, Duke University. Accessed October 30, 2020. http://hdl.handle.net/10161/8725.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Jantzen, Alexandra Elizabeth. “Seeding of Titanium Surfaces and Nitinol Stents with Blood-Derived Endothelial Cells .” 2014. Web. 30 Oct 2020.

Vancouver:

Jantzen AE. Seeding of Titanium Surfaces and Nitinol Stents with Blood-Derived Endothelial Cells . [Internet] [Thesis]. Duke University; 2014. [cited 2020 Oct 30]. Available from: http://hdl.handle.net/10161/8725.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Jantzen AE. Seeding of Titanium Surfaces and Nitinol Stents with Blood-Derived Endothelial Cells . [Thesis]. Duke University; 2014. Available from: http://hdl.handle.net/10161/8725

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Cal Poly

30. rudow, matthew. Effect of Oxidation on Weld Strengthof Dissimilar Resistance Weld Interface Between 304 Stainless Steeland Near Equiatomic Austenitic Nitinol Guide Wire.

Degree: MS, Materials Engineering, 2012, Cal Poly

  Abbott Vascular encountered strength and variability issues when attempting to resistively weld 304 Stainless Steel to equiatomic Nitinol. Initial observations suggested that passivation layer… (more)

Subjects/Keywords: Nitinol; 304 Stainless Steel; Resistance; Weld; Precipitate; Metallurgy

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

rudow, m. (2012). Effect of Oxidation on Weld Strengthof Dissimilar Resistance Weld Interface Between 304 Stainless Steeland Near Equiatomic Austenitic Nitinol Guide Wire. (Masters Thesis). Cal Poly. Retrieved from https://digitalcommons.calpoly.edu/theses/855 ; 10.15368/theses.2012.144

Chicago Manual of Style (16th Edition):

rudow, matthew. “Effect of Oxidation on Weld Strengthof Dissimilar Resistance Weld Interface Between 304 Stainless Steeland Near Equiatomic Austenitic Nitinol Guide Wire.” 2012. Masters Thesis, Cal Poly. Accessed October 30, 2020. https://digitalcommons.calpoly.edu/theses/855 ; 10.15368/theses.2012.144.

MLA Handbook (7th Edition):

rudow, matthew. “Effect of Oxidation on Weld Strengthof Dissimilar Resistance Weld Interface Between 304 Stainless Steeland Near Equiatomic Austenitic Nitinol Guide Wire.” 2012. Web. 30 Oct 2020.

Vancouver:

rudow m. Effect of Oxidation on Weld Strengthof Dissimilar Resistance Weld Interface Between 304 Stainless Steeland Near Equiatomic Austenitic Nitinol Guide Wire. [Internet] [Masters thesis]. Cal Poly; 2012. [cited 2020 Oct 30]. Available from: https://digitalcommons.calpoly.edu/theses/855 ; 10.15368/theses.2012.144.

Council of Science Editors:

rudow m. Effect of Oxidation on Weld Strengthof Dissimilar Resistance Weld Interface Between 304 Stainless Steeland Near Equiatomic Austenitic Nitinol Guide Wire. [Masters Thesis]. Cal Poly; 2012. Available from: https://digitalcommons.calpoly.edu/theses/855 ; 10.15368/theses.2012.144

[1] [2] [3] [4]

.