You searched for subject:(Internal fixation in fractures). Showing records 1 – 30 of 84218 total matches.

[1] [2] [3] [4] [5] … [2808]

Search Limiters

Last 2 Years | English Only

Degrees

Levels

Languages

Country

▼ Search Limiters


University of Western Australia

1. Stoffel, Karl Kilian. Modern concepts in plate osteosynthesis.

Degree: PhD, 2007, University of Western Australia

[Truncated abstract] Renewed interest in the fixation of fractures using plates has been stimulated by an improved understanding of the biology of fracture healing and… (more)

Subjects/Keywords: Bone plates (Orthopedics); Fractures; Internal fixation in fractures; Fracture fixation; Plate osteosynthesis

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Stoffel, K. K. (2007). Modern concepts in plate osteosynthesis. (Doctoral Dissertation). University of Western Australia. Retrieved from http://repository.uwa.edu.au:80/R/?func=dbin-jump-full&object_id=8931&local_base=GEN01-INS01

Chicago Manual of Style (16th Edition):

Stoffel, Karl Kilian. “Modern concepts in plate osteosynthesis.” 2007. Doctoral Dissertation, University of Western Australia. Accessed August 17, 2018. http://repository.uwa.edu.au:80/R/?func=dbin-jump-full&object_id=8931&local_base=GEN01-INS01.

MLA Handbook (7th Edition):

Stoffel, Karl Kilian. “Modern concepts in plate osteosynthesis.” 2007. Web. 17 Aug 2018.

Vancouver:

Stoffel KK. Modern concepts in plate osteosynthesis. [Internet] [Doctoral dissertation]. University of Western Australia; 2007. [cited 2018 Aug 17]. Available from: http://repository.uwa.edu.au:80/R/?func=dbin-jump-full&object_id=8931&local_base=GEN01-INS01.

Council of Science Editors:

Stoffel KK. Modern concepts in plate osteosynthesis. [Doctoral Dissertation]. University of Western Australia; 2007. Available from: http://repository.uwa.edu.au:80/R/?func=dbin-jump-full&object_id=8931&local_base=GEN01-INS01


Ryerson University

2. Saeid Samiezadeh. Development of a composite intramedullary nail for treating femoral shaft fractures.

Degree: PhD, 2016, Ryerson University

 Intramedullary nails are the primary choice for treating long bone fractures. However, the high axial rigidity of conventional nails, can significantly reduce compression at the… (more)

Subjects/Keywords: Intramedullary fracture fixation; Fracture fixation; Internal fixation in fractures; Orthopedic surgery; Orthopedic implants

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Samiezadeh, S. (2016). Development of a composite intramedullary nail for treating femoral shaft fractures. (Doctoral Dissertation). Ryerson University. Retrieved from http://digital.library.ryerson.ca/islandora/object/RULA%3A4994 ;

Chicago Manual of Style (16th Edition):

Samiezadeh, Saeid. “Development of a composite intramedullary nail for treating femoral shaft fractures.” 2016. Doctoral Dissertation, Ryerson University. Accessed August 17, 2018. http://digital.library.ryerson.ca/islandora/object/RULA%3A4994 ;.

MLA Handbook (7th Edition):

Samiezadeh, Saeid. “Development of a composite intramedullary nail for treating femoral shaft fractures.” 2016. Web. 17 Aug 2018.

Vancouver:

Samiezadeh S. Development of a composite intramedullary nail for treating femoral shaft fractures. [Internet] [Doctoral dissertation]. Ryerson University; 2016. [cited 2018 Aug 17]. Available from: http://digital.library.ryerson.ca/islandora/object/RULA%3A4994 ;.

Council of Science Editors:

Samiezadeh S. Development of a composite intramedullary nail for treating femoral shaft fractures. [Doctoral Dissertation]. Ryerson University; 2016. Available from: http://digital.library.ryerson.ca/islandora/object/RULA%3A4994 ;


University of Hong Kong

3. Sia, Charles Pactol. Internal versus intermaxillary fixation in vertical subsigmoid osteotomy for mandibular setback: arandomized controlled trial.

Degree: Master of Dental Surgery, 2011, University of Hong Kong

published_or_final_version

Dental Surgery

Master

Master of Dental Surgery

Subjects/Keywords: Internal fixation in fractures.; Mandible - Surgery.

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Sia, C. P. (2011). Internal versus intermaxillary fixation in vertical subsigmoid osteotomy for mandibular setback: arandomized controlled trial. (Masters Thesis). University of Hong Kong. Retrieved from Sia, C. P. [謝漢明]. (2011). Internal versus intermaxillary fixation in vertical subsigmoid osteotomy for mandibular setback : a randomized controlled trial. (Thesis). University of Hong Kong, Pokfulam, Hong Kong SAR. Retrieved from http://dx.doi.org/10.5353/th_b4660009 ; http://dx.doi.org/10.5353/th_b4660009 ; http://hdl.handle.net/10722/143243

Chicago Manual of Style (16th Edition):

Sia, Charles Pactol. “Internal versus intermaxillary fixation in vertical subsigmoid osteotomy for mandibular setback: arandomized controlled trial.” 2011. Masters Thesis, University of Hong Kong. Accessed August 17, 2018. Sia, C. P. [謝漢明]. (2011). Internal versus intermaxillary fixation in vertical subsigmoid osteotomy for mandibular setback : a randomized controlled trial. (Thesis). University of Hong Kong, Pokfulam, Hong Kong SAR. Retrieved from http://dx.doi.org/10.5353/th_b4660009 ; http://dx.doi.org/10.5353/th_b4660009 ; http://hdl.handle.net/10722/143243.

MLA Handbook (7th Edition):

Sia, Charles Pactol. “Internal versus intermaxillary fixation in vertical subsigmoid osteotomy for mandibular setback: arandomized controlled trial.” 2011. Web. 17 Aug 2018.

Vancouver:

Sia CP. Internal versus intermaxillary fixation in vertical subsigmoid osteotomy for mandibular setback: arandomized controlled trial. [Internet] [Masters thesis]. University of Hong Kong; 2011. [cited 2018 Aug 17]. Available from: Sia, C. P. [謝漢明]. (2011). Internal versus intermaxillary fixation in vertical subsigmoid osteotomy for mandibular setback : a randomized controlled trial. (Thesis). University of Hong Kong, Pokfulam, Hong Kong SAR. Retrieved from http://dx.doi.org/10.5353/th_b4660009 ; http://dx.doi.org/10.5353/th_b4660009 ; http://hdl.handle.net/10722/143243.

Council of Science Editors:

Sia CP. Internal versus intermaxillary fixation in vertical subsigmoid osteotomy for mandibular setback: arandomized controlled trial. [Masters Thesis]. University of Hong Kong; 2011. Available from: Sia, C. P. [謝漢明]. (2011). Internal versus intermaxillary fixation in vertical subsigmoid osteotomy for mandibular setback : a randomized controlled trial. (Thesis). University of Hong Kong, Pokfulam, Hong Kong SAR. Retrieved from http://dx.doi.org/10.5353/th_b4660009 ; http://dx.doi.org/10.5353/th_b4660009 ; http://hdl.handle.net/10722/143243


University of Hong Kong

4. 周立強.; Chow, Lop-keung, Raymond. Clinical morbidity of resorbable plates and screws for internal fixation in orthognathic surgery.

Degree: Master of Dental Surgery, 2003, University of Hong Kong

published_or_final_version

Dentistry

Master

Master of Dental Surgery

Subjects/Keywords: Teeth - Surgery.; Internal fixation in fractures.; Bone plates (Orthopedics)

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

周立強.; Chow, Lop-keung, R. (2003). Clinical morbidity of resorbable plates and screws for internal fixation in orthognathic surgery. (Masters Thesis). University of Hong Kong. Retrieved from Chow, L. R. [周立強]. (2003). Clinical morbidity of resorbable plates and screws for internal fixation in orthognathic surgery. (Thesis). University of Hong Kong, Pokfulam, Hong Kong SAR. Retrieved from http://dx.doi.org/10.5353/th_b3195428 ; http://dx.doi.org/10.5353/th_b3195428 ; http://hdl.handle.net/10722/40694

Chicago Manual of Style (16th Edition):

周立強.; Chow, Lop-keung, Raymond. “Clinical morbidity of resorbable plates and screws for internal fixation in orthognathic surgery.” 2003. Masters Thesis, University of Hong Kong. Accessed August 17, 2018. Chow, L. R. [周立強]. (2003). Clinical morbidity of resorbable plates and screws for internal fixation in orthognathic surgery. (Thesis). University of Hong Kong, Pokfulam, Hong Kong SAR. Retrieved from http://dx.doi.org/10.5353/th_b3195428 ; http://dx.doi.org/10.5353/th_b3195428 ; http://hdl.handle.net/10722/40694.

MLA Handbook (7th Edition):

周立強.; Chow, Lop-keung, Raymond. “Clinical morbidity of resorbable plates and screws for internal fixation in orthognathic surgery.” 2003. Web. 17 Aug 2018.

Vancouver:

周立強.; Chow, Lop-keung R. Clinical morbidity of resorbable plates and screws for internal fixation in orthognathic surgery. [Internet] [Masters thesis]. University of Hong Kong; 2003. [cited 2018 Aug 17]. Available from: Chow, L. R. [周立強]. (2003). Clinical morbidity of resorbable plates and screws for internal fixation in orthognathic surgery. (Thesis). University of Hong Kong, Pokfulam, Hong Kong SAR. Retrieved from http://dx.doi.org/10.5353/th_b3195428 ; http://dx.doi.org/10.5353/th_b3195428 ; http://hdl.handle.net/10722/40694.

Council of Science Editors:

周立強.; Chow, Lop-keung R. Clinical morbidity of resorbable plates and screws for internal fixation in orthognathic surgery. [Masters Thesis]. University of Hong Kong; 2003. Available from: Chow, L. R. [周立強]. (2003). Clinical morbidity of resorbable plates and screws for internal fixation in orthognathic surgery. (Thesis). University of Hong Kong, Pokfulam, Hong Kong SAR. Retrieved from http://dx.doi.org/10.5353/th_b3195428 ; http://dx.doi.org/10.5353/th_b3195428 ; http://hdl.handle.net/10722/40694


McGill University

5. Bobyn, John Dennis. The strength of fixation of porous metal implants by the ingrowth of bone.

Degree: MS, Department of Mechanical Engineering, 1977, McGill University

Subjects/Keywords: Orthopedic implants.; Bone plates (Orthopedics); Internal fixation in fractures.

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Bobyn, J. D. (1977). The strength of fixation of porous metal implants by the ingrowth of bone. (Masters Thesis). McGill University. Retrieved from http://digitool.library.mcgill.ca/thesisfile54513.pdf

Chicago Manual of Style (16th Edition):

Bobyn, John Dennis. “The strength of fixation of porous metal implants by the ingrowth of bone.” 1977. Masters Thesis, McGill University. Accessed August 17, 2018. http://digitool.library.mcgill.ca/thesisfile54513.pdf.

MLA Handbook (7th Edition):

Bobyn, John Dennis. “The strength of fixation of porous metal implants by the ingrowth of bone.” 1977. Web. 17 Aug 2018.

Vancouver:

Bobyn JD. The strength of fixation of porous metal implants by the ingrowth of bone. [Internet] [Masters thesis]. McGill University; 1977. [cited 2018 Aug 17]. Available from: http://digitool.library.mcgill.ca/thesisfile54513.pdf.

Council of Science Editors:

Bobyn JD. The strength of fixation of porous metal implants by the ingrowth of bone. [Masters Thesis]. McGill University; 1977. Available from: http://digitool.library.mcgill.ca/thesisfile54513.pdf


University of Alberta

6. Evenson, Robert. A system for evaluating spinal fixation devices.

Degree: MS, Department of Mechanical Engineering, 1988, University of Alberta

Subjects/Keywords: Lumbar vertebrae – Fractures – Treatment.; Bone screws (Orthopedics) – Evaluation.; Internal fixation in fractures.

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Evenson, R. (1988). A system for evaluating spinal fixation devices. (Masters Thesis). University of Alberta. Retrieved from https://era.library.ualberta.ca/files/736666340

Chicago Manual of Style (16th Edition):

Evenson, Robert. “A system for evaluating spinal fixation devices.” 1988. Masters Thesis, University of Alberta. Accessed August 17, 2018. https://era.library.ualberta.ca/files/736666340.

MLA Handbook (7th Edition):

Evenson, Robert. “A system for evaluating spinal fixation devices.” 1988. Web. 17 Aug 2018.

Vancouver:

Evenson R. A system for evaluating spinal fixation devices. [Internet] [Masters thesis]. University of Alberta; 1988. [cited 2018 Aug 17]. Available from: https://era.library.ualberta.ca/files/736666340.

Council of Science Editors:

Evenson R. A system for evaluating spinal fixation devices. [Masters Thesis]. University of Alberta; 1988. Available from: https://era.library.ualberta.ca/files/736666340

7. Benegas, Eduardo. Estudo comparativo entre a haste intramedular bloqueada e a placa em ponte no tratamento cirúrgico das fraturas da diáfise do úmero.

Degree: PhD, Ortopedia e Traumatologia, 2008, University of São Paulo

O objetivo deste estudo é o de comparar os resultados clínicos e radiográficos do tratamento cirúrgico das fraturas da diáfise do úmero com haste intramedular… (more)

Subjects/Keywords: Dispositivos de fixação óssea; Ensaios clínicos controlados aleatórios como assunto; Estudos prospectivos; Fixação interna de fratura/reabilitação; Follow-up; Fraturas do úmero/cirurgia; Humerus fractures/surgery; Implants in orthopaedic fixation; Internal fixation of fractures/reabilitation; Prospective trials; RCT Randomized clinical trials as subject controlled; Seguimentos

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Benegas, E. (2008). Estudo comparativo entre a haste intramedular bloqueada e a placa em ponte no tratamento cirúrgico das fraturas da diáfise do úmero. (Doctoral Dissertation). University of São Paulo. Retrieved from http://www.teses.usp.br/teses/disponiveis/5/5140/tde-12022009-130247/ ;

Chicago Manual of Style (16th Edition):

Benegas, Eduardo. “Estudo comparativo entre a haste intramedular bloqueada e a placa em ponte no tratamento cirúrgico das fraturas da diáfise do úmero.” 2008. Doctoral Dissertation, University of São Paulo. Accessed August 17, 2018. http://www.teses.usp.br/teses/disponiveis/5/5140/tde-12022009-130247/ ;.

MLA Handbook (7th Edition):

Benegas, Eduardo. “Estudo comparativo entre a haste intramedular bloqueada e a placa em ponte no tratamento cirúrgico das fraturas da diáfise do úmero.” 2008. Web. 17 Aug 2018.

Vancouver:

Benegas E. Estudo comparativo entre a haste intramedular bloqueada e a placa em ponte no tratamento cirúrgico das fraturas da diáfise do úmero. [Internet] [Doctoral dissertation]. University of São Paulo; 2008. [cited 2018 Aug 17]. Available from: http://www.teses.usp.br/teses/disponiveis/5/5140/tde-12022009-130247/ ;.

Council of Science Editors:

Benegas E. Estudo comparativo entre a haste intramedular bloqueada e a placa em ponte no tratamento cirúrgico das fraturas da diáfise do úmero. [Doctoral Dissertation]. University of São Paulo; 2008. Available from: http://www.teses.usp.br/teses/disponiveis/5/5140/tde-12022009-130247/ ;


Texas A&M University

8. Nixon, Joseph Craig. Analysis of load redistribution in diaphyseal bone following staged screw removal from bone plates.

Degree: MS, bioengineering, 2012, Texas A&M University

Subjects/Keywords: bioengineering.; Major bioengineering.; Bone plates (Orthopedics); Internal fixation in fractures.; Osteopenia.

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Nixon, J. C. (2012). Analysis of load redistribution in diaphyseal bone following staged screw removal from bone plates. (Masters Thesis). Texas A&M University. Retrieved from http://hdl.handle.net/1969.1/ETD-TAMU-1987-THESIS-N736

Chicago Manual of Style (16th Edition):

Nixon, Joseph Craig. “Analysis of load redistribution in diaphyseal bone following staged screw removal from bone plates.” 2012. Masters Thesis, Texas A&M University. Accessed August 17, 2018. http://hdl.handle.net/1969.1/ETD-TAMU-1987-THESIS-N736.

MLA Handbook (7th Edition):

Nixon, Joseph Craig. “Analysis of load redistribution in diaphyseal bone following staged screw removal from bone plates.” 2012. Web. 17 Aug 2018.

Vancouver:

Nixon JC. Analysis of load redistribution in diaphyseal bone following staged screw removal from bone plates. [Internet] [Masters thesis]. Texas A&M University; 2012. [cited 2018 Aug 17]. Available from: http://hdl.handle.net/1969.1/ETD-TAMU-1987-THESIS-N736.

Council of Science Editors:

Nixon JC. Analysis of load redistribution in diaphyseal bone following staged screw removal from bone plates. [Masters Thesis]. Texas A&M University; 2012. Available from: http://hdl.handle.net/1969.1/ETD-TAMU-1987-THESIS-N736


University of Hong Kong

9. 葉永玉; Ip, Wing-yuk. Design and biomechanical study of internal fixation devices for difficult phalangeal fractures.

Degree: Master of Surgery, 2002, University of Hong Kong

published_or_final_version

Surgery

Master

Master of Surgery

Subjects/Keywords: Fingers - Wounds and injuries.; Internal fixation in fractures.; Fingers - Surgery.

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

葉永玉; Ip, W. (2002). Design and biomechanical study of internal fixation devices for difficult phalangeal fractures. (Masters Thesis). University of Hong Kong. Retrieved from Ip, W. [葉永玉]. (2002). Design and biomechanical study of internal fixation devices for difficult phalangeal fractures. (Thesis). University of Hong Kong, Pokfulam, Hong Kong SAR. Retrieved from http://dx.doi.org/10.5353/th_b3197966 ; http://dx.doi.org/10.5353/th_b3197966 ; http://hdl.handle.net/10722/30067

Chicago Manual of Style (16th Edition):

葉永玉; Ip, Wing-yuk. “Design and biomechanical study of internal fixation devices for difficult phalangeal fractures.” 2002. Masters Thesis, University of Hong Kong. Accessed August 17, 2018. Ip, W. [葉永玉]. (2002). Design and biomechanical study of internal fixation devices for difficult phalangeal fractures. (Thesis). University of Hong Kong, Pokfulam, Hong Kong SAR. Retrieved from http://dx.doi.org/10.5353/th_b3197966 ; http://dx.doi.org/10.5353/th_b3197966 ; http://hdl.handle.net/10722/30067.

MLA Handbook (7th Edition):

葉永玉; Ip, Wing-yuk. “Design and biomechanical study of internal fixation devices for difficult phalangeal fractures.” 2002. Web. 17 Aug 2018.

Vancouver:

葉永玉; Ip W. Design and biomechanical study of internal fixation devices for difficult phalangeal fractures. [Internet] [Masters thesis]. University of Hong Kong; 2002. [cited 2018 Aug 17]. Available from: Ip, W. [葉永玉]. (2002). Design and biomechanical study of internal fixation devices for difficult phalangeal fractures. (Thesis). University of Hong Kong, Pokfulam, Hong Kong SAR. Retrieved from http://dx.doi.org/10.5353/th_b3197966 ; http://dx.doi.org/10.5353/th_b3197966 ; http://hdl.handle.net/10722/30067.

Council of Science Editors:

葉永玉; Ip W. Design and biomechanical study of internal fixation devices for difficult phalangeal fractures. [Masters Thesis]. University of Hong Kong; 2002. Available from: Ip, W. [葉永玉]. (2002). Design and biomechanical study of internal fixation devices for difficult phalangeal fractures. (Thesis). University of Hong Kong, Pokfulam, Hong Kong SAR. Retrieved from http://dx.doi.org/10.5353/th_b3197966 ; http://dx.doi.org/10.5353/th_b3197966 ; http://hdl.handle.net/10722/30067


Universidade do Rio Grande do Norte

10. Oliveira, Kerlison Paulino de. Avaliação mecânica in vitro utilizando miniplacas quadradas e retangulares do sistema 2.0 mm em fraturas da região anterior de mandíbula .

Degree: 2012, Universidade do Rio Grande do Norte

 The aim of this study was to comparatively evaluate the mechanical strength of squared and rectangular 2.0 mm system miniplates comparing them to the standard… (more)

Subjects/Keywords: Fixação interna de fraturas. Fraturas mandibulares. Materiais biocompatíveis; Internal fixation of fractures. Mandibular fractures. Biocompatible materials

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Oliveira, K. P. d. (2012). Avaliação mecânica in vitro utilizando miniplacas quadradas e retangulares do sistema 2.0 mm em fraturas da região anterior de mandíbula . (Thesis). Universidade do Rio Grande do Norte. Retrieved from http://repositorio.ufrn.br/handle/123456789/17806

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Oliveira, Kerlison Paulino de. “Avaliação mecânica in vitro utilizando miniplacas quadradas e retangulares do sistema 2.0 mm em fraturas da região anterior de mandíbula .” 2012. Thesis, Universidade do Rio Grande do Norte. Accessed August 17, 2018. http://repositorio.ufrn.br/handle/123456789/17806.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Oliveira, Kerlison Paulino de. “Avaliação mecânica in vitro utilizando miniplacas quadradas e retangulares do sistema 2.0 mm em fraturas da região anterior de mandíbula .” 2012. Web. 17 Aug 2018.

Vancouver:

Oliveira KPd. Avaliação mecânica in vitro utilizando miniplacas quadradas e retangulares do sistema 2.0 mm em fraturas da região anterior de mandíbula . [Internet] [Thesis]. Universidade do Rio Grande do Norte; 2012. [cited 2018 Aug 17]. Available from: http://repositorio.ufrn.br/handle/123456789/17806.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Oliveira KPd. Avaliação mecânica in vitro utilizando miniplacas quadradas e retangulares do sistema 2.0 mm em fraturas da região anterior de mandíbula . [Thesis]. Universidade do Rio Grande do Norte; 2012. Available from: http://repositorio.ufrn.br/handle/123456789/17806

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Universidade do Rio Grande do Norte

11. Oliveira, Kerlison Paulino de. Avaliação mecânica in vitro utilizando miniplacas quadradas e retangulares do sistema 2.0 mm em fraturas da região anterior de mandíbula .

Degree: 2012, Universidade do Rio Grande do Norte

 The aim of this study was to comparatively evaluate the mechanical strength of squared and rectangular 2.0 mm system miniplates comparing them to the standard… (more)

Subjects/Keywords: Fixação interna de fraturas. Fraturas mandibulares. Materiais biocompatíveis; Internal fixation of fractures. Mandibular fractures. Biocompatible materials

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Oliveira, K. P. d. (2012). Avaliação mecânica in vitro utilizando miniplacas quadradas e retangulares do sistema 2.0 mm em fraturas da região anterior de mandíbula . (Masters Thesis). Universidade do Rio Grande do Norte. Retrieved from http://repositorio.ufrn.br/handle/123456789/17806

Chicago Manual of Style (16th Edition):

Oliveira, Kerlison Paulino de. “Avaliação mecânica in vitro utilizando miniplacas quadradas e retangulares do sistema 2.0 mm em fraturas da região anterior de mandíbula .” 2012. Masters Thesis, Universidade do Rio Grande do Norte. Accessed August 17, 2018. http://repositorio.ufrn.br/handle/123456789/17806.

MLA Handbook (7th Edition):

Oliveira, Kerlison Paulino de. “Avaliação mecânica in vitro utilizando miniplacas quadradas e retangulares do sistema 2.0 mm em fraturas da região anterior de mandíbula .” 2012. Web. 17 Aug 2018.

Vancouver:

Oliveira KPd. Avaliação mecânica in vitro utilizando miniplacas quadradas e retangulares do sistema 2.0 mm em fraturas da região anterior de mandíbula . [Internet] [Masters thesis]. Universidade do Rio Grande do Norte; 2012. [cited 2018 Aug 17]. Available from: http://repositorio.ufrn.br/handle/123456789/17806.

Council of Science Editors:

Oliveira KPd. Avaliação mecânica in vitro utilizando miniplacas quadradas e retangulares do sistema 2.0 mm em fraturas da região anterior de mandíbula . [Masters Thesis]. Universidade do Rio Grande do Norte; 2012. Available from: http://repositorio.ufrn.br/handle/123456789/17806


University of Missouri – Columbia

12. Janicek, John Charles. In vitro three dimensional biomechanical comparison of two internal fixation methods in equine adult radii.

Degree: 2007, University of Missouri – Columbia

 Radius fracture configurations conducive to internal fixation most often contain a spiral or oblique fracture of the distal diaphysis. The location and fracture configurations are… (more)

Subjects/Keywords: Horses  – Wounds and injuries; Internal fixation in fractures; Bones  – Mechanical properties; Biological models; Radius (Anatomy)  – Fractures  – Treatment

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Janicek, J. C. (2007). In vitro three dimensional biomechanical comparison of two internal fixation methods in equine adult radii. (Thesis). University of Missouri – Columbia. Retrieved from http://hdl.handle.net/10355/4927

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Janicek, John Charles. “In vitro three dimensional biomechanical comparison of two internal fixation methods in equine adult radii.” 2007. Thesis, University of Missouri – Columbia. Accessed August 17, 2018. http://hdl.handle.net/10355/4927.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Janicek, John Charles. “In vitro three dimensional biomechanical comparison of two internal fixation methods in equine adult radii.” 2007. Web. 17 Aug 2018.

Vancouver:

Janicek JC. In vitro three dimensional biomechanical comparison of two internal fixation methods in equine adult radii. [Internet] [Thesis]. University of Missouri – Columbia; 2007. [cited 2018 Aug 17]. Available from: http://hdl.handle.net/10355/4927.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Janicek JC. In vitro three dimensional biomechanical comparison of two internal fixation methods in equine adult radii. [Thesis]. University of Missouri – Columbia; 2007. Available from: http://hdl.handle.net/10355/4927

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Zambia

13. Phiri, Godfrey. A five year review of the outcomes of intramedullary nailing of diaphyseal femur fractures in Lusaka .

Degree: University of Zambia

 Trauma is increasing in Zambia and currently ranks 4th in causing morbidity and mortality (WHO, 2008). Head Injury (HI) and fractures of long bones are… (more)

Subjects/Keywords: Fracture fixation-Atlases; Fractures, Bone-Surgery; Fracture fixation, internal-Methods; Femoral fractures-Surgery; Femur-fractures; Hip fractures-Surgery

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Phiri, G. (n.d.). A five year review of the outcomes of intramedullary nailing of diaphyseal femur fractures in Lusaka . (Thesis). University of Zambia. Retrieved from http://dspace.unza.zm:8080/xmlui/handle/123456789/5112

Note: this citation may be lacking information needed for this citation format:
No year of publication.
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Phiri, Godfrey. “A five year review of the outcomes of intramedullary nailing of diaphyseal femur fractures in Lusaka .” Thesis, University of Zambia. Accessed August 17, 2018. http://dspace.unza.zm:8080/xmlui/handle/123456789/5112.

Note: this citation may be lacking information needed for this citation format:
No year of publication.
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Phiri, Godfrey. “A five year review of the outcomes of intramedullary nailing of diaphyseal femur fractures in Lusaka .” Web. 17 Aug 2018.

Note: this citation may be lacking information needed for this citation format:
No year of publication.

Vancouver:

Phiri G. A five year review of the outcomes of intramedullary nailing of diaphyseal femur fractures in Lusaka . [Internet] [Thesis]. University of Zambia; [cited 2018 Aug 17]. Available from: http://dspace.unza.zm:8080/xmlui/handle/123456789/5112.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
No year of publication.

Council of Science Editors:

Phiri G. A five year review of the outcomes of intramedullary nailing of diaphyseal femur fractures in Lusaka . [Thesis]. University of Zambia; Available from: http://dspace.unza.zm:8080/xmlui/handle/123456789/5112

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
No year of publication.

14. Warren, Paul B. Processing and evaluation of long fiber thermoplastic composite plates for internal fixation.

Degree: MS, 2012, University of Alabama – Birmingham

The metallic plates used in internal fracture fixation may have up to ten times the elastic modulus of normal bone tissue, causing stress shielding-induced osteopenia… (more)

Subjects/Keywords: Bone plates (Orthopedics) – Materials – Evaluation<; br>; Bone substitutes – Evaluation<; br>; Internal fixation in fractures<; br>; Thermoplastic composites – Mechanical properties<; br>; Reinforced thermoplastics – Mechanical properties<; br>; Metallic composites – Mechanical properties<; br>; Polymers in medicine

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Warren, P. B. (2012). Processing and evaluation of long fiber thermoplastic composite plates for internal fixation. (Masters Thesis). University of Alabama – Birmingham. Retrieved from http://contentdm.mhsl.uab.edu/u?/etd,1314

Chicago Manual of Style (16th Edition):

Warren, Paul B. “Processing and evaluation of long fiber thermoplastic composite plates for internal fixation.” 2012. Masters Thesis, University of Alabama – Birmingham. Accessed August 17, 2018. http://contentdm.mhsl.uab.edu/u?/etd,1314.

MLA Handbook (7th Edition):

Warren, Paul B. “Processing and evaluation of long fiber thermoplastic composite plates for internal fixation.” 2012. Web. 17 Aug 2018.

Vancouver:

Warren PB. Processing and evaluation of long fiber thermoplastic composite plates for internal fixation. [Internet] [Masters thesis]. University of Alabama – Birmingham; 2012. [cited 2018 Aug 17]. Available from: http://contentdm.mhsl.uab.edu/u?/etd,1314.

Council of Science Editors:

Warren PB. Processing and evaluation of long fiber thermoplastic composite plates for internal fixation. [Masters Thesis]. University of Alabama – Birmingham; 2012. Available from: http://contentdm.mhsl.uab.edu/u?/etd,1314

15. Yamamoto, Marcos Kazuo. Necessidade de reabordagem cirúrgica após tratamento de fraturas mandibulares por fixação interna rígida.

Degree: PhD, Cirurgia e Traumatologia Buco-Maxilo-Faciais, 2010, University of São Paulo

As fraturas de mandíbula são freqüentes e o seu tratamento é por meio de fixação interna rígida. Complicações podem ocorrer após o tratamento das fraturas… (more)

Subjects/Keywords: Complicações; Complications; Fixação interna rígida; Fraturas mandibulares; Infecção; Infection; Internal rigid fixation; Mandibular fractures; Nonunion; Osteomielite; Osteomyelitis; Pseudoartrose

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Yamamoto, M. K. (2010). Necessidade de reabordagem cirúrgica após tratamento de fraturas mandibulares por fixação interna rígida. (Doctoral Dissertation). University of São Paulo. Retrieved from http://www.teses.usp.br/teses/disponiveis/23/23149/tde-18112010-124009/ ;

Chicago Manual of Style (16th Edition):

Yamamoto, Marcos Kazuo. “Necessidade de reabordagem cirúrgica após tratamento de fraturas mandibulares por fixação interna rígida.” 2010. Doctoral Dissertation, University of São Paulo. Accessed August 17, 2018. http://www.teses.usp.br/teses/disponiveis/23/23149/tde-18112010-124009/ ;.

MLA Handbook (7th Edition):

Yamamoto, Marcos Kazuo. “Necessidade de reabordagem cirúrgica após tratamento de fraturas mandibulares por fixação interna rígida.” 2010. Web. 17 Aug 2018.

Vancouver:

Yamamoto MK. Necessidade de reabordagem cirúrgica após tratamento de fraturas mandibulares por fixação interna rígida. [Internet] [Doctoral dissertation]. University of São Paulo; 2010. [cited 2018 Aug 17]. Available from: http://www.teses.usp.br/teses/disponiveis/23/23149/tde-18112010-124009/ ;.

Council of Science Editors:

Yamamoto MK. Necessidade de reabordagem cirúrgica após tratamento de fraturas mandibulares por fixação interna rígida. [Doctoral Dissertation]. University of São Paulo; 2010. Available from: http://www.teses.usp.br/teses/disponiveis/23/23149/tde-18112010-124009/ ;

16. Gaiarsa, Guilherme Pelosini. Estudo comparativo entre as osteossínteses de tornozelo com implantes convencionais e bioabsorvíveis.

Degree: Mestrado, Ortopedia e Traumatologia, 2013, University of São Paulo

O padrão ouro no tratamento cirúrgico das fraturas de tornozelo são as sínteses metálicas, sejam de titânio ou aço. Os implantes bioabsorvíveis foram desenvolvidos para… (more)

Subjects/Keywords: Absorbable implants; Ankle; Comparative study; Estudo comparativo; Fixação interna de fraturas; Fracture fixation internal; Fractures bone; Fraturas ósseas; Implantes absorvíveis; Tornozelo

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Gaiarsa, G. P. (2013). Estudo comparativo entre as osteossínteses de tornozelo com implantes convencionais e bioabsorvíveis. (Masters Thesis). University of São Paulo. Retrieved from http://www.teses.usp.br/teses/disponiveis/5/5140/tde-26032013-111341/ ;

Chicago Manual of Style (16th Edition):

Gaiarsa, Guilherme Pelosini. “Estudo comparativo entre as osteossínteses de tornozelo com implantes convencionais e bioabsorvíveis.” 2013. Masters Thesis, University of São Paulo. Accessed August 17, 2018. http://www.teses.usp.br/teses/disponiveis/5/5140/tde-26032013-111341/ ;.

MLA Handbook (7th Edition):

Gaiarsa, Guilherme Pelosini. “Estudo comparativo entre as osteossínteses de tornozelo com implantes convencionais e bioabsorvíveis.” 2013. Web. 17 Aug 2018.

Vancouver:

Gaiarsa GP. Estudo comparativo entre as osteossínteses de tornozelo com implantes convencionais e bioabsorvíveis. [Internet] [Masters thesis]. University of São Paulo; 2013. [cited 2018 Aug 17]. Available from: http://www.teses.usp.br/teses/disponiveis/5/5140/tde-26032013-111341/ ;.

Council of Science Editors:

Gaiarsa GP. Estudo comparativo entre as osteossínteses de tornozelo com implantes convencionais e bioabsorvíveis. [Masters Thesis]. University of São Paulo; 2013. Available from: http://www.teses.usp.br/teses/disponiveis/5/5140/tde-26032013-111341/ ;

17. Ngo, Khai. Development of testing systems to analyze strength of hormonally treated ligaments and stability of fixation devices.

Degree: 2000, Texas Tech University

 This thesis presents the results of two distinct research projects. The first project involved an investigation into the causes of injuries to anterior cruciate ligaments… (more)

Subjects/Keywords: Internal fixation in fractures; Estrogen; Pelvic bones; Anterior cruciate ligament (ACL)

…devices used for internal fixation of fractures; hence, there is a need to quantify the… …reverse obliquity intertrochanteric hip fractures. The former usually occurs in sports or… …effectiveness of the fixation they provide in order to ensure successful recovery. 1.2 Methodology in… …shown in Figure 2.2. This method of mounting allowed for fixation of the specimen without… …mounting device is shown in Figure B.l in Appendix B. Figure 2.2 - ACL Specimen Fixation Device… 

Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Ngo, K. (2000). Development of testing systems to analyze strength of hormonally treated ligaments and stability of fixation devices. (Masters Thesis). Texas Tech University. Retrieved from http://hdl.handle.net/2346/10959

Chicago Manual of Style (16th Edition):

Ngo, Khai. “Development of testing systems to analyze strength of hormonally treated ligaments and stability of fixation devices.” 2000. Masters Thesis, Texas Tech University. Accessed August 17, 2018. http://hdl.handle.net/2346/10959.

MLA Handbook (7th Edition):

Ngo, Khai. “Development of testing systems to analyze strength of hormonally treated ligaments and stability of fixation devices.” 2000. Web. 17 Aug 2018.

Vancouver:

Ngo K. Development of testing systems to analyze strength of hormonally treated ligaments and stability of fixation devices. [Internet] [Masters thesis]. Texas Tech University; 2000. [cited 2018 Aug 17]. Available from: http://hdl.handle.net/2346/10959.

Council of Science Editors:

Ngo K. Development of testing systems to analyze strength of hormonally treated ligaments and stability of fixation devices. [Masters Thesis]. Texas Tech University; 2000. Available from: http://hdl.handle.net/2346/10959

18. Bastos, Endrigo Oliveira. Avaliação do tratamento cirúrgico das fraturas de côndilo mandibular pelo acesso retromandibular transparotídeo.

Degree: Mestrado, Cirurgia Plástica, 2010, University of São Paulo

 INTRODUÇÃO: A redução cirúrgica e fixação rígida por meio do acesso retromandibular transparotídeo vem se difundindo como uma das opções para o controverso tratamento das… (more)

Subjects/Keywords: Côndilo mandibular; Fixação interna de fraturas/métodos; Fracture fixation internal/methods; Fraturas mandibulares/cirurgia; Fraturas mandibulares/terapia; Imagem tridimensional; Imaging three-dimensional; Mandibular condyle; Mandibular fractures/surgery; Mandibular fractures/therapy

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Bastos, E. O. (2010). Avaliação do tratamento cirúrgico das fraturas de côndilo mandibular pelo acesso retromandibular transparotídeo. (Masters Thesis). University of São Paulo. Retrieved from http://www.teses.usp.br/teses/disponiveis/5/5158/tde-21122010-120024/ ;

Chicago Manual of Style (16th Edition):

Bastos, Endrigo Oliveira. “Avaliação do tratamento cirúrgico das fraturas de côndilo mandibular pelo acesso retromandibular transparotídeo.” 2010. Masters Thesis, University of São Paulo. Accessed August 17, 2018. http://www.teses.usp.br/teses/disponiveis/5/5158/tde-21122010-120024/ ;.

MLA Handbook (7th Edition):

Bastos, Endrigo Oliveira. “Avaliação do tratamento cirúrgico das fraturas de côndilo mandibular pelo acesso retromandibular transparotídeo.” 2010. Web. 17 Aug 2018.

Vancouver:

Bastos EO. Avaliação do tratamento cirúrgico das fraturas de côndilo mandibular pelo acesso retromandibular transparotídeo. [Internet] [Masters thesis]. University of São Paulo; 2010. [cited 2018 Aug 17]. Available from: http://www.teses.usp.br/teses/disponiveis/5/5158/tde-21122010-120024/ ;.

Council of Science Editors:

Bastos EO. Avaliação do tratamento cirúrgico das fraturas de côndilo mandibular pelo acesso retromandibular transparotídeo. [Masters Thesis]. University of São Paulo; 2010. Available from: http://www.teses.usp.br/teses/disponiveis/5/5158/tde-21122010-120024/ ;

19. Αγοραστάκης, Δημήτριος. Κατάγματα και οστικά ελλείμματα των μετακαρπίων και των φαλάγγων: σύγχρονες μέθοδοι οστεοσύνθεσης: ταξινόμηση, αλγόριθμος θεραπευτικής προσέγγισης, αξιολόγηση της έκβασης.

Degree: 2012, University of Thessaly (UTH); Πανεπιστήμιο Θεσσαλίας

In this prospective, non-randomised study, the aim was to assess the effectiveness of two state-of-the-art methods of osteosynthesis in a variety of different fracture patterns… (more)

Subjects/Keywords: Κατάγματα; Μετακάρπια; Φάλαγγες; Εξωτερική οστεοσύνθεση; Οστικά ελλείμματα; Εσωτερική οστεοσύνθεση; Πλάκες χαμηλού προφίλ; Χέρια; Fractures; Metacarpals; Phalanges; External fixation; Internal fixation; Low profile plates; Skeletal defects; Osteosynthesis

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Αγοραστάκης, . . (2012). Κατάγματα και οστικά ελλείμματα των μετακαρπίων και των φαλάγγων: σύγχρονες μέθοδοι οστεοσύνθεσης: ταξινόμηση, αλγόριθμος θεραπευτικής προσέγγισης, αξιολόγηση της έκβασης. (Thesis). University of Thessaly (UTH); Πανεπιστήμιο Θεσσαλίας. Retrieved from http://hdl.handle.net/10442/hedi/28610

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Αγοραστάκης, Δημήτριος. “Κατάγματα και οστικά ελλείμματα των μετακαρπίων και των φαλάγγων: σύγχρονες μέθοδοι οστεοσύνθεσης: ταξινόμηση, αλγόριθμος θεραπευτικής προσέγγισης, αξιολόγηση της έκβασης.” 2012. Thesis, University of Thessaly (UTH); Πανεπιστήμιο Θεσσαλίας. Accessed August 17, 2018. http://hdl.handle.net/10442/hedi/28610.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Αγοραστάκης, Δημήτριος. “Κατάγματα και οστικά ελλείμματα των μετακαρπίων και των φαλάγγων: σύγχρονες μέθοδοι οστεοσύνθεσης: ταξινόμηση, αλγόριθμος θεραπευτικής προσέγγισης, αξιολόγηση της έκβασης.” 2012. Web. 17 Aug 2018.

Vancouver:

Αγοραστάκης . Κατάγματα και οστικά ελλείμματα των μετακαρπίων και των φαλάγγων: σύγχρονες μέθοδοι οστεοσύνθεσης: ταξινόμηση, αλγόριθμος θεραπευτικής προσέγγισης, αξιολόγηση της έκβασης. [Internet] [Thesis]. University of Thessaly (UTH); Πανεπιστήμιο Θεσσαλίας; 2012. [cited 2018 Aug 17]. Available from: http://hdl.handle.net/10442/hedi/28610.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Αγοραστάκης . Κατάγματα και οστικά ελλείμματα των μετακαρπίων και των φαλάγγων: σύγχρονες μέθοδοι οστεοσύνθεσης: ταξινόμηση, αλγόριθμος θεραπευτικής προσέγγισης, αξιολόγηση της έκβασης. [Thesis]. University of Thessaly (UTH); Πανεπιστήμιο Θεσσαλίας; 2012. Available from: http://hdl.handle.net/10442/hedi/28610

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Zambia

20. Chibeza, Faith Tiza. A prospective study to determine the prevalence of deep vein thrombosis in patients with pelvic, femoral and tibia/fibular fractures at the University Teaching Hospital in Lusaka .

Degree: 2015, University of Zambia

 Deep vein thrombosis (DVT) is a known occurrence in patients who have suffered trauma, especially severe trauma. The complication of DVT that makes it a… (more)

Subjects/Keywords: Fractures – Treatment – Zambia; Fracsture fixation – Complications – Zambia

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Chibeza, F. T. (2015). A prospective study to determine the prevalence of deep vein thrombosis in patients with pelvic, femoral and tibia/fibular fractures at the University Teaching Hospital in Lusaka . (Thesis). University of Zambia. Retrieved from http://dspace.unza.zm:8080/xmlui/handle/123456789/4396

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Chibeza, Faith Tiza. “A prospective study to determine the prevalence of deep vein thrombosis in patients with pelvic, femoral and tibia/fibular fractures at the University Teaching Hospital in Lusaka .” 2015. Thesis, University of Zambia. Accessed August 17, 2018. http://dspace.unza.zm:8080/xmlui/handle/123456789/4396.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Chibeza, Faith Tiza. “A prospective study to determine the prevalence of deep vein thrombosis in patients with pelvic, femoral and tibia/fibular fractures at the University Teaching Hospital in Lusaka .” 2015. Web. 17 Aug 2018.

Vancouver:

Chibeza FT. A prospective study to determine the prevalence of deep vein thrombosis in patients with pelvic, femoral and tibia/fibular fractures at the University Teaching Hospital in Lusaka . [Internet] [Thesis]. University of Zambia; 2015. [cited 2018 Aug 17]. Available from: http://dspace.unza.zm:8080/xmlui/handle/123456789/4396.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Chibeza FT. A prospective study to determine the prevalence of deep vein thrombosis in patients with pelvic, femoral and tibia/fibular fractures at the University Teaching Hospital in Lusaka . [Thesis]. University of Zambia; 2015. Available from: http://dspace.unza.zm:8080/xmlui/handle/123456789/4396

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

21. ΠΑΚΟΣ, ΣΩΤΗΡΙΟΣ. ΑΝΤΙΜΕΤΩΠΙΣΗ ΚΑΤΑΓΜΑΤΩΝ ΔΙΑΦΥΣΗΣ ΚΝΗΜΗΣ ΜΕ ΕΣΩΤΕΡΙΚΗ ΟΣΤΕΟΣΥΝΘΕΣΗ.

Degree: 1997, Πανεπιστήμιο Ιωαννίνων; University of Ioannina

ΑΝΤΙΜΕΤΩΠΙΣΑΜΕ ΣΤΗΝ ΚΛΙΝΙΚΗ ΜΑΣ ΜΕ ΕΣΩΤΕΡΙΚΗ ΟΣΤΕΟΣΥΝΘΕΣΗ (ΠΛΑΚΑ - ACP) ΙΙΙ ΚΑΤΑΓΜΑΤΑ ΔΙΑΦΥΣΗΣ ΚΝΗΜΗΣ ΑΠΟ ΤΟ 1982 - 1994. ΕΠΑΝΕΞΕΤΑΣΘΗΚΑΝ 58 ΑΣΘΕΝΕΙΣ ΜΕ ΜΕΣΟ ΧΡΟΝΟ… (more)

Subjects/Keywords: Fractures; Internal fixation; SHAFT; Tibia; ΔΙΑΦΥΣΗ; ΕΣΩΤΕΡΙΚΗ ΟΣΤΕΟΣΥΝΘΕΣΗ; Κατάγματα; Κνήμη

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

ΠΑΚΟΣ, . (1997). ΑΝΤΙΜΕΤΩΠΙΣΗ ΚΑΤΑΓΜΑΤΩΝ ΔΙΑΦΥΣΗΣ ΚΝΗΜΗΣ ΜΕ ΕΣΩΤΕΡΙΚΗ ΟΣΤΕΟΣΥΝΘΕΣΗ. (Thesis). Πανεπιστήμιο Ιωαννίνων; University of Ioannina. Retrieved from http://hdl.handle.net/10442/hedi/8759

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

ΠΑΚΟΣ, ΣΩΤΗΡΙΟΣ. “ΑΝΤΙΜΕΤΩΠΙΣΗ ΚΑΤΑΓΜΑΤΩΝ ΔΙΑΦΥΣΗΣ ΚΝΗΜΗΣ ΜΕ ΕΣΩΤΕΡΙΚΗ ΟΣΤΕΟΣΥΝΘΕΣΗ.” 1997. Thesis, Πανεπιστήμιο Ιωαννίνων; University of Ioannina. Accessed August 17, 2018. http://hdl.handle.net/10442/hedi/8759.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

ΠΑΚΟΣ, ΣΩΤΗΡΙΟΣ. “ΑΝΤΙΜΕΤΩΠΙΣΗ ΚΑΤΑΓΜΑΤΩΝ ΔΙΑΦΥΣΗΣ ΚΝΗΜΗΣ ΜΕ ΕΣΩΤΕΡΙΚΗ ΟΣΤΕΟΣΥΝΘΕΣΗ.” 1997. Web. 17 Aug 2018.

Vancouver:

ΠΑΚΟΣ . ΑΝΤΙΜΕΤΩΠΙΣΗ ΚΑΤΑΓΜΑΤΩΝ ΔΙΑΦΥΣΗΣ ΚΝΗΜΗΣ ΜΕ ΕΣΩΤΕΡΙΚΗ ΟΣΤΕΟΣΥΝΘΕΣΗ. [Internet] [Thesis]. Πανεπιστήμιο Ιωαννίνων; University of Ioannina; 1997. [cited 2018 Aug 17]. Available from: http://hdl.handle.net/10442/hedi/8759.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

ΠΑΚΟΣ . ΑΝΤΙΜΕΤΩΠΙΣΗ ΚΑΤΑΓΜΑΤΩΝ ΔΙΑΦΥΣΗΣ ΚΝΗΜΗΣ ΜΕ ΕΣΩΤΕΡΙΚΗ ΟΣΤΕΟΣΥΝΘΕΣΗ. [Thesis]. Πανεπιστήμιο Ιωαννίνων; University of Ioannina; 1997. Available from: http://hdl.handle.net/10442/hedi/8759

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Edinburgh

22. Mackenzie, Samuel Peter. Bioabsorbable implants in paediatric supracondylar fractures of the elbow.

Degree: Thesis (M.D.), 2018, University of Edinburgh

 Background. Operative stabilisation of paediatric supracondylar elbow fractures is most commonly achieved through the use of percutaneous Kirschner wires. These implants are inert, cheap and… (more)

Subjects/Keywords: Kirschner wire; fractures fixation; bioabsorbable pin; Biotrak Helical Nail; elbow fractures

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Mackenzie, S. P. (2018). Bioabsorbable implants in paediatric supracondylar fractures of the elbow. (Doctoral Dissertation). University of Edinburgh. Retrieved from http://hdl.handle.net/1842/28963

Chicago Manual of Style (16th Edition):

Mackenzie, Samuel Peter. “Bioabsorbable implants in paediatric supracondylar fractures of the elbow.” 2018. Doctoral Dissertation, University of Edinburgh. Accessed August 17, 2018. http://hdl.handle.net/1842/28963.

MLA Handbook (7th Edition):

Mackenzie, Samuel Peter. “Bioabsorbable implants in paediatric supracondylar fractures of the elbow.” 2018. Web. 17 Aug 2018.

Vancouver:

Mackenzie SP. Bioabsorbable implants in paediatric supracondylar fractures of the elbow. [Internet] [Doctoral dissertation]. University of Edinburgh; 2018. [cited 2018 Aug 17]. Available from: http://hdl.handle.net/1842/28963.

Council of Science Editors:

Mackenzie SP. Bioabsorbable implants in paediatric supracondylar fractures of the elbow. [Doctoral Dissertation]. University of Edinburgh; 2018. Available from: http://hdl.handle.net/1842/28963


Universidade Federal da Bahia

23. Christiano Sampaio Queiroz. Estudo comparativo entre a fixação interna e a fixação in-termaxilar no reparo ósseo de fraturas mandibulares por meio de imagem radiográfica digital.

Degree: 2007, Universidade Federal da Bahia

Conventional radiographic evaluation of fracture healing is not a reliable method, because it depends on the examinators experience and the quality of the exam. Therefore,… (more)

Subjects/Keywords: jaw fixation techniques; fracture fixation; técnica de subtração; técnicas de fixação da mandíbula; fixação interna de fraturas; dental; ODONTOLOGIA; radiography; mandibular fractures; fraturas mandibulares; digital; subtraction technique; internal; radiografia dentária digital

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Queiroz, C. S. (2007). Estudo comparativo entre a fixação interna e a fixação in-termaxilar no reparo ósseo de fraturas mandibulares por meio de imagem radiográfica digital. (Thesis). Universidade Federal da Bahia. Retrieved from http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1420 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1425 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1418 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1421 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1423 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1417 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1419 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1424 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1422

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Queiroz, Christiano Sampaio. “Estudo comparativo entre a fixação interna e a fixação in-termaxilar no reparo ósseo de fraturas mandibulares por meio de imagem radiográfica digital.” 2007. Thesis, Universidade Federal da Bahia. Accessed August 17, 2018. http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1420 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1425 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1418 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1421 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1423 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1417 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1419 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1424 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1422.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Queiroz, Christiano Sampaio. “Estudo comparativo entre a fixação interna e a fixação in-termaxilar no reparo ósseo de fraturas mandibulares por meio de imagem radiográfica digital.” 2007. Web. 17 Aug 2018.

Vancouver:

Queiroz CS. Estudo comparativo entre a fixação interna e a fixação in-termaxilar no reparo ósseo de fraturas mandibulares por meio de imagem radiográfica digital. [Internet] [Thesis]. Universidade Federal da Bahia; 2007. [cited 2018 Aug 17]. Available from: http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1420 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1425 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1418 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1421 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1423 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1417 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1419 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1424 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1422.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Queiroz CS. Estudo comparativo entre a fixação interna e a fixação in-termaxilar no reparo ósseo de fraturas mandibulares por meio de imagem radiográfica digital. [Thesis]. Universidade Federal da Bahia; 2007. Available from: http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1420 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1425 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1418 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1421 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1423 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1417 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1419 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1424 ; http://www.bibliotecadigital.ufba.br/tde_busca/arquivo.php?codArquivo=1422

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

24. Μαλακάση, Αποστόλω. Συγκριτική μελέτη της υβριδικής εξωτερικής οστεοσύνθεσης και της συμβατικής εσωτερικής στη χειρουργική αντιμετώπιση των καταγμάτων των κνημιαίων κονδύλων.

Degree: 2012, National and Kapodistrian University of Athens; Εθνικό και Καποδιστριακό Πανεπιστήμιο Αθηνών (ΕΚΠΑ)

 The purpose of this study was the comparison, clinically and experimentally, of the adequacy of hybrid external fixation in relation to the internal in the… (more)

Subjects/Keywords: ΚΑΤΑΓΜΑΤΑ ΚΝΗΜΙΑΙΩΝ ΚΟΝΔΥΛΩΝ; Υβριδική εξωτερική οστεοσύνθεση; Ανοικτή ανάταξη και εσωτερική οστεοσύνθεση; Φόρτιση του σκέλους; Μέθοδος πεπερασμένων στοιχείων; TIBIAL CONDYLAR FRACTURES; Hybrid external fixation; Open reduction and internal fixation; Weight bearing; Finite element method

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Μαλακάση, . . (2012). Συγκριτική μελέτη της υβριδικής εξωτερικής οστεοσύνθεσης και της συμβατικής εσωτερικής στη χειρουργική αντιμετώπιση των καταγμάτων των κνημιαίων κονδύλων. (Thesis). National and Kapodistrian University of Athens; Εθνικό και Καποδιστριακό Πανεπιστήμιο Αθηνών (ΕΚΠΑ). Retrieved from http://hdl.handle.net/10442/hedi/29576

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Μαλακάση, Αποστόλω. “Συγκριτική μελέτη της υβριδικής εξωτερικής οστεοσύνθεσης και της συμβατικής εσωτερικής στη χειρουργική αντιμετώπιση των καταγμάτων των κνημιαίων κονδύλων.” 2012. Thesis, National and Kapodistrian University of Athens; Εθνικό και Καποδιστριακό Πανεπιστήμιο Αθηνών (ΕΚΠΑ). Accessed August 17, 2018. http://hdl.handle.net/10442/hedi/29576.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Μαλακάση, Αποστόλω. “Συγκριτική μελέτη της υβριδικής εξωτερικής οστεοσύνθεσης και της συμβατικής εσωτερικής στη χειρουργική αντιμετώπιση των καταγμάτων των κνημιαίων κονδύλων.” 2012. Web. 17 Aug 2018.

Vancouver:

Μαλακάση . Συγκριτική μελέτη της υβριδικής εξωτερικής οστεοσύνθεσης και της συμβατικής εσωτερικής στη χειρουργική αντιμετώπιση των καταγμάτων των κνημιαίων κονδύλων. [Internet] [Thesis]. National and Kapodistrian University of Athens; Εθνικό και Καποδιστριακό Πανεπιστήμιο Αθηνών (ΕΚΠΑ); 2012. [cited 2018 Aug 17]. Available from: http://hdl.handle.net/10442/hedi/29576.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Μαλακάση . Συγκριτική μελέτη της υβριδικής εξωτερικής οστεοσύνθεσης και της συμβατικής εσωτερικής στη χειρουργική αντιμετώπιση των καταγμάτων των κνημιαίων κονδύλων. [Thesis]. National and Kapodistrian University of Athens; Εθνικό και Καποδιστριακό Πανεπιστήμιο Αθηνών (ΕΚΠΑ); 2012. Available from: http://hdl.handle.net/10442/hedi/29576

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

25. Μάρης, Ιωάννης. Αντιμετώπιση των σηπτικών ψευδαρθρώσεων των μακρών αυλοειδών οστών.

Degree: 2001, National and Kapodistrian University of Athens; Εθνικό και Καποδιστριακό Πανεπιστήμιο Αθηνών (ΕΚΠΑ)

Subjects/Keywords: Ψευδάρθρωση; Οστική λοίμωξη; Οστεομυελίτιδα; Κατάγματα, Ανοικτά; Οστεοσύνθεση, Εξωτερική; Οστεοσύνθεση, Εσωτερική και λοίμωξη; Non union; Bones, Infection; Septic nonunion; Fractures, Open; Osteomyeliis, Post - traumatic; Fractures, Complications of open; Fractures, Internal fixation of; External fixation

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Μάρης, . . (2001). Αντιμετώπιση των σηπτικών ψευδαρθρώσεων των μακρών αυλοειδών οστών. (Thesis). National and Kapodistrian University of Athens; Εθνικό και Καποδιστριακό Πανεπιστήμιο Αθηνών (ΕΚΠΑ). Retrieved from http://hdl.handle.net/10442/hedi/20627

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Μάρης, Ιωάννης. “Αντιμετώπιση των σηπτικών ψευδαρθρώσεων των μακρών αυλοειδών οστών.” 2001. Thesis, National and Kapodistrian University of Athens; Εθνικό και Καποδιστριακό Πανεπιστήμιο Αθηνών (ΕΚΠΑ). Accessed August 17, 2018. http://hdl.handle.net/10442/hedi/20627.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Μάρης, Ιωάννης. “Αντιμετώπιση των σηπτικών ψευδαρθρώσεων των μακρών αυλοειδών οστών.” 2001. Web. 17 Aug 2018.

Vancouver:

Μάρης . Αντιμετώπιση των σηπτικών ψευδαρθρώσεων των μακρών αυλοειδών οστών. [Internet] [Thesis]. National and Kapodistrian University of Athens; Εθνικό και Καποδιστριακό Πανεπιστήμιο Αθηνών (ΕΚΠΑ); 2001. [cited 2018 Aug 17]. Available from: http://hdl.handle.net/10442/hedi/20627.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Μάρης . Αντιμετώπιση των σηπτικών ψευδαρθρώσεων των μακρών αυλοειδών οστών. [Thesis]. National and Kapodistrian University of Athens; Εθνικό και Καποδιστριακό Πανεπιστήμιο Αθηνών (ΕΚΠΑ); 2001. Available from: http://hdl.handle.net/10442/hedi/20627

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

26. Prem Raj. An evaluation of result of closed reduction and percutanceous kirschner wire fixation of fractures of lower and of radius; -.

Degree: Medicine, 1999, Bundelkhand University

None

Bibliography p.73-75

Advisors/Committee Members: Dabral, P K.

Subjects/Keywords: Surgery; fixation; fractures; radius fractures; lower fractures

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Raj, P. (1999). An evaluation of result of closed reduction and percutanceous kirschner wire fixation of fractures of lower and of radius; -. (Thesis). Bundelkhand University. Retrieved from http://shodhganga.inflibnet.ac.in/handle/10603/12455

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Raj, Prem. “An evaluation of result of closed reduction and percutanceous kirschner wire fixation of fractures of lower and of radius; -.” 1999. Thesis, Bundelkhand University. Accessed August 17, 2018. http://shodhganga.inflibnet.ac.in/handle/10603/12455.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Raj, Prem. “An evaluation of result of closed reduction and percutanceous kirschner wire fixation of fractures of lower and of radius; -.” 1999. Web. 17 Aug 2018.

Vancouver:

Raj P. An evaluation of result of closed reduction and percutanceous kirschner wire fixation of fractures of lower and of radius; -. [Internet] [Thesis]. Bundelkhand University; 1999. [cited 2018 Aug 17]. Available from: http://shodhganga.inflibnet.ac.in/handle/10603/12455.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Raj P. An evaluation of result of closed reduction and percutanceous kirschner wire fixation of fractures of lower and of radius; -. [Thesis]. Bundelkhand University; 1999. Available from: http://shodhganga.inflibnet.ac.in/handle/10603/12455

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Alberta

27. Begum, Farhana. Experimental and numerical analysis of augmented locking plate fixation repair for proximal humeral fractures.

Degree: MS, Department of Civil and Environmental Engineering, 2011, University of Alberta

 Failure of locking plate fixation due to varus collapse is a common problem for the elderly population who have osteoporotic bone with comminuted fractures. However,… (more)

Subjects/Keywords: Locking plate fixation; Proximal humeral fractures; Fibular graft

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Begum, F. (2011). Experimental and numerical analysis of augmented locking plate fixation repair for proximal humeral fractures. (Masters Thesis). University of Alberta. Retrieved from https://era.library.ualberta.ca/files/2n49t200k

Chicago Manual of Style (16th Edition):

Begum, Farhana. “Experimental and numerical analysis of augmented locking plate fixation repair for proximal humeral fractures.” 2011. Masters Thesis, University of Alberta. Accessed August 17, 2018. https://era.library.ualberta.ca/files/2n49t200k.

MLA Handbook (7th Edition):

Begum, Farhana. “Experimental and numerical analysis of augmented locking plate fixation repair for proximal humeral fractures.” 2011. Web. 17 Aug 2018.

Vancouver:

Begum F. Experimental and numerical analysis of augmented locking plate fixation repair for proximal humeral fractures. [Internet] [Masters thesis]. University of Alberta; 2011. [cited 2018 Aug 17]. Available from: https://era.library.ualberta.ca/files/2n49t200k.

Council of Science Editors:

Begum F. Experimental and numerical analysis of augmented locking plate fixation repair for proximal humeral fractures. [Masters Thesis]. University of Alberta; 2011. Available from: https://era.library.ualberta.ca/files/2n49t200k

28. Singh, Umesh. To evaluate the role of tension band wiring as a method of internal fixation in various fractures; -.

Degree: Orthopedic Surgery, 1991, Bundelkhand University

None

Bibliography p.115-119

Advisors/Committee Members: Anurag, M S.

Subjects/Keywords: fixation,; fractures,; tension; wiring

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Singh, U. (1991). To evaluate the role of tension band wiring as a method of internal fixation in various fractures; -. (Thesis). Bundelkhand University. Retrieved from http://shodhganga.inflibnet.ac.in/handle/10603/12518

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Singh, Umesh. “To evaluate the role of tension band wiring as a method of internal fixation in various fractures; -.” 1991. Thesis, Bundelkhand University. Accessed August 17, 2018. http://shodhganga.inflibnet.ac.in/handle/10603/12518.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Singh, Umesh. “To evaluate the role of tension band wiring as a method of internal fixation in various fractures; -.” 1991. Web. 17 Aug 2018.

Vancouver:

Singh U. To evaluate the role of tension band wiring as a method of internal fixation in various fractures; -. [Internet] [Thesis]. Bundelkhand University; 1991. [cited 2018 Aug 17]. Available from: http://shodhganga.inflibnet.ac.in/handle/10603/12518.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Singh U. To evaluate the role of tension band wiring as a method of internal fixation in various fractures; -. [Thesis]. Bundelkhand University; 1991. Available from: http://shodhganga.inflibnet.ac.in/handle/10603/12518

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Missouri – Columbia

29. Arnone, Joshua. A comprehensive simulation-based methodology for the design and optimization of orthopaedic internal fixation implants.

Degree: 2011, University of Missouri – Columbia

Internal fixation implants are widely used by orthopaedic surgeons to stabilize various types of fractures in injured patients. However, the irregular geometry of the human… (more)

Subjects/Keywords: biomechanics; internal fixation implant; structural integrity

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Arnone, J. (2011). A comprehensive simulation-based methodology for the design and optimization of orthopaedic internal fixation implants. (Thesis). University of Missouri – Columbia. Retrieved from http://hdl.handle.net/10355/15993

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Arnone, Joshua. “A comprehensive simulation-based methodology for the design and optimization of orthopaedic internal fixation implants.” 2011. Thesis, University of Missouri – Columbia. Accessed August 17, 2018. http://hdl.handle.net/10355/15993.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Arnone, Joshua. “A comprehensive simulation-based methodology for the design and optimization of orthopaedic internal fixation implants.” 2011. Web. 17 Aug 2018.

Vancouver:

Arnone J. A comprehensive simulation-based methodology for the design and optimization of orthopaedic internal fixation implants. [Internet] [Thesis]. University of Missouri – Columbia; 2011. [cited 2018 Aug 17]. Available from: http://hdl.handle.net/10355/15993.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Arnone J. A comprehensive simulation-based methodology for the design and optimization of orthopaedic internal fixation implants. [Thesis]. University of Missouri – Columbia; 2011. Available from: http://hdl.handle.net/10355/15993

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Texas A&M University

30. Perkins, Luke 1990-. Evaluation of Bone Fixation Implants.

Degree: 2012, Texas A&M University

 This research investigates the effects of the human body on the mechanical, chemical, and morphological properties of the surface of internal fixation devices. Stainless steel… (more)

Subjects/Keywords: Material Properties; Bone Implant Materials; Internal Fixation

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Perkins, L. 1. (2012). Evaluation of Bone Fixation Implants. (Thesis). Texas A&M University. Retrieved from http://hdl.handle.net/1969.1/148271

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Perkins, Luke 1990-. “Evaluation of Bone Fixation Implants.” 2012. Thesis, Texas A&M University. Accessed August 17, 2018. http://hdl.handle.net/1969.1/148271.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Perkins, Luke 1990-. “Evaluation of Bone Fixation Implants.” 2012. Web. 17 Aug 2018.

Vancouver:

Perkins L1. Evaluation of Bone Fixation Implants. [Internet] [Thesis]. Texas A&M University; 2012. [cited 2018 Aug 17]. Available from: http://hdl.handle.net/1969.1/148271.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Perkins L1. Evaluation of Bone Fixation Implants. [Thesis]. Texas A&M University; 2012. Available from: http://hdl.handle.net/1969.1/148271

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

[1] [2] [3] [4] [5] … [2808]

.