Advanced search options

Advanced Search Options 🞨

Browse by author name (“Author name starts with…”).

Find ETDs with:

in
/  
in
/  
in
/  
in

Written in Published in Earliest date Latest date

Sorted by

Results per page:

You searched for subject:(Frutos do mar). One record found.

Search Limiters

Last 2 Years | English Only

No search limiters apply to these results.

▼ Search Limiters

1. Adriana Alice de Oliveira. Determinação de iodo por espectrometria de emissão óptica com plasma acoplado indutivamente com configuração axial.

Degree: 2009, Universidade Federal de São Carlos

Neste trabalho avaliou-se um espectrômetro de emissão óptica com plasma acoplado indutivamente com configuração axial para a determinação de iodo em amostras de frutos do mar e sal de cozinha. As possíveis linhas de emissão de iodo foram avaliadas considerando-se parâmetros como razão sinal analítico / sinal de fundo (SBR), concentração equivalente ao sinal de fundo (BEC) e limite de detecção (LOD). As possíveis interferências dos cátions Na+ e K+ e de P nos sinais de emissão de iodo e a ocorrência de efeito de memória em meio de HNO3 e em solução de aminas terciárias solúveis em água (CFA-C) também foram estudados. Planejamento fatorial 23 + Ponto Central + Estrela foi realizado para a avaliação das condições operacionais do ICP OES com configuração axial e de outro equipamento com configuração radial na determinação de iodo, obtendo-se uma região ótima de trabalho para a configuração axial e duas condições ótimas para a configuração radial. A configuração axial mostrouse cinco vezes mais sensível do que a configuração radial. A possibilidade de utilização do ICP OES com configuração axial para determinação de iodo em sal de cozinha foi investigada. Empregou-se compatibilização de matriz e o método das adições de padrão para a quantificação de iodo. Para a maioria das amostras obteve-se boa concordância entre ambos as estratégias de quantificação. Recuperações na faixa de 104 a 114 % foram obtidas mesmo para amostras nas quais não houve concordância entre os resultados obtidos empregando quantificação por compatibilização de matriz ou o método das adições de padrão. A determinação de iodo em frutos do mar por ICP OES com configuração axial também foi investigada. Como estratégia para preparo de amostra, empregou-se extração alcalina (CFA-C 10% v v-1 pH 8) com banho de ultrassom durante 3 h a 80C. As recuperações obtid as para os materiais de referência certificados tecido de ostra (NIST 1566b) e leite em pó desnatado (NIST 1549) foram de 113 e 102 %, respectivamente.

In this work it was evaluated the performance of an inductively coupled plasma spectrometer with axial viewed configuration for determining iodine in seafood and table salts. The emission lines of iodine were evaluated based on parameters such as signalto-background ratio (SBR), background equivalent concentration (BEC) and limit of detection (LOD). Interference effects caused by Na+, K+, and P in the emission signals of iodine and the occurrence of memory effects in nitric acid and in water-soluble tertiaryamines (CFA-C) media were also evaluated. Factorial design 2 + Central Point + Star, was applied for evaluating the operational conditions of the ICP OES with axial configuration and also for an other equipment with radial configuration both applied for iodine determination. An optimum instrument operational condition was established for axial configuration and two optimum conditions for radial configuration. The axial configuration was five fold more sensitive than the radial configuration. The applicability of ICP OES with axial configuration…

Advisors/Committee Members: Joaquim de Araujo Nóbrega.

Subjects/Keywords: ICP-OES; Iodo; Sal; Frutos do mar; QUIMICA

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Oliveira, A. A. d. (2009). Determinação de iodo por espectrometria de emissão óptica com plasma acoplado indutivamente com configuração axial. (Thesis). Universidade Federal de São Carlos. Retrieved from http://www.bdtd.ufscar.br/htdocs/tedeSimplificado//tde_busca/arquivo.php?codArquivo=2506

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Oliveira, Adriana Alice de. “Determinação de iodo por espectrometria de emissão óptica com plasma acoplado indutivamente com configuração axial.” 2009. Thesis, Universidade Federal de São Carlos. Accessed July 09, 2020. http://www.bdtd.ufscar.br/htdocs/tedeSimplificado//tde_busca/arquivo.php?codArquivo=2506.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Oliveira, Adriana Alice de. “Determinação de iodo por espectrometria de emissão óptica com plasma acoplado indutivamente com configuração axial.” 2009. Web. 09 Jul 2020.

Vancouver:

Oliveira AAd. Determinação de iodo por espectrometria de emissão óptica com plasma acoplado indutivamente com configuração axial. [Internet] [Thesis]. Universidade Federal de São Carlos; 2009. [cited 2020 Jul 09]. Available from: http://www.bdtd.ufscar.br/htdocs/tedeSimplificado//tde_busca/arquivo.php?codArquivo=2506.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Oliveira AAd. Determinação de iodo por espectrometria de emissão óptica com plasma acoplado indutivamente com configuração axial. [Thesis]. Universidade Federal de São Carlos; 2009. Available from: http://www.bdtd.ufscar.br/htdocs/tedeSimplificado//tde_busca/arquivo.php?codArquivo=2506

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

.