Advanced search options

Advanced Search Options 🞨

Browse by author name (“Author name starts with…”).

Find ETDs with:

in
/  
in
/  
in
/  
in

Written in Published in Earliest date Latest date

Sorted by

Results per page:

Sorted by: relevance · author · university · dateNew search

You searched for subject:(Fricke Xylenol Gel dosimeter). Showing records 1 – 30 of 2374 total matches.

[1] [2] [3] [4] [5] … [80]

Search Limiters

Last 2 Years | English Only

Degrees

Levels

Languages

Country

▼ Search Limiters

1. Silva, Aldriano José da. Desenvolvimento de um leitor digital de absorbância microprocessado.

Degree: Mestrado, Física Aplicada à Medicina e Biologia, 2011, University of São Paulo

O espectrofotômetro, aparelho muito utilizado para realizar leituras de absorbância e/ou transmitância de amostras laboratoriais, pode ser aplicado para a realização de leituras do dosímetro… (more)

Subjects/Keywords: Dosimeter Fricke Xylenol Gel; Dosímetro Fricke Xilenol Ge; Instrumentação; Instrumentation; Microcontrolador; Microcontroller

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Silva, A. J. d. (2011). Desenvolvimento de um leitor digital de absorbância microprocessado. (Masters Thesis). University of São Paulo. Retrieved from http://www.teses.usp.br/teses/disponiveis/59/59135/tde-04052011-003401/ ;

Chicago Manual of Style (16th Edition):

Silva, Aldriano José da. “Desenvolvimento de um leitor digital de absorbância microprocessado.” 2011. Masters Thesis, University of São Paulo. Accessed January 24, 2020. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-04052011-003401/ ;.

MLA Handbook (7th Edition):

Silva, Aldriano José da. “Desenvolvimento de um leitor digital de absorbância microprocessado.” 2011. Web. 24 Jan 2020.

Vancouver:

Silva AJd. Desenvolvimento de um leitor digital de absorbância microprocessado. [Internet] [Masters thesis]. University of São Paulo; 2011. [cited 2020 Jan 24]. Available from: http://www.teses.usp.br/teses/disponiveis/59/59135/tde-04052011-003401/ ;.

Council of Science Editors:

Silva AJd. Desenvolvimento de um leitor digital de absorbância microprocessado. [Masters Thesis]. University of São Paulo; 2011. Available from: http://www.teses.usp.br/teses/disponiveis/59/59135/tde-04052011-003401/ ;

2. Oliveira, Lucas Nonato de. Parâmetros dosimétricos e coeficiente de difusão para elétrons em campos pequenos, através do dosímetro Fricke Xilenol Gel.

Degree: PhD, Física Aplicada à Medicina e Biologia, 2007, University of São Paulo

A qualidade para o tratamento radioterápico depende essencialmente da capacidade de realizar medidas de dose absorvida no volume de tratamento, minimizando aquela nos tecidos vizinhos,… (more)

Subjects/Keywords: Fricke Gel Dosimeter; Fricke Xilenol Gel

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Oliveira, L. N. d. (2007). Parâmetros dosimétricos e coeficiente de difusão para elétrons em campos pequenos, através do dosímetro Fricke Xilenol Gel. (Doctoral Dissertation). University of São Paulo. Retrieved from http://www.teses.usp.br/teses/disponiveis/59/59135/tde-06062008-173808/ ;

Chicago Manual of Style (16th Edition):

Oliveira, Lucas Nonato de. “Parâmetros dosimétricos e coeficiente de difusão para elétrons em campos pequenos, através do dosímetro Fricke Xilenol Gel.” 2007. Doctoral Dissertation, University of São Paulo. Accessed January 24, 2020. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-06062008-173808/ ;.

MLA Handbook (7th Edition):

Oliveira, Lucas Nonato de. “Parâmetros dosimétricos e coeficiente de difusão para elétrons em campos pequenos, através do dosímetro Fricke Xilenol Gel.” 2007. Web. 24 Jan 2020.

Vancouver:

Oliveira LNd. Parâmetros dosimétricos e coeficiente de difusão para elétrons em campos pequenos, através do dosímetro Fricke Xilenol Gel. [Internet] [Doctoral dissertation]. University of São Paulo; 2007. [cited 2020 Jan 24]. Available from: http://www.teses.usp.br/teses/disponiveis/59/59135/tde-06062008-173808/ ;.

Council of Science Editors:

Oliveira LNd. Parâmetros dosimétricos e coeficiente de difusão para elétrons em campos pequenos, através do dosímetro Fricke Xilenol Gel. [Doctoral Dissertation]. University of São Paulo; 2007. Available from: http://www.teses.usp.br/teses/disponiveis/59/59135/tde-06062008-173808/ ;

3. Oliveira, David Marçal Machado de. Verificação do uso do dosímetro Fricke benzóico xilenol gel em tomografia computadorizada.

Degree: Mestrado, Física Aplicada à Medicina e Biologia, 2011, University of São Paulo

A tomografia computadorizada (CT) representa a maior fonte de exposição aos raios X médicos e seu uso continua crescendo rapidamente, devido aos aparelhos de última… (more)

Subjects/Keywords: computed tomography; dosimetria; dosimetry; Fricke benzoic xylenol gel; Fricke benzóico xilenol gel; tomografia computadorizada

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Oliveira, D. M. M. d. (2011). Verificação do uso do dosímetro Fricke benzóico xilenol gel em tomografia computadorizada. (Masters Thesis). University of São Paulo. Retrieved from http://www.teses.usp.br/teses/disponiveis/59/59135/tde-08122011-154718/ ;

Chicago Manual of Style (16th Edition):

Oliveira, David Marçal Machado de. “Verificação do uso do dosímetro Fricke benzóico xilenol gel em tomografia computadorizada.” 2011. Masters Thesis, University of São Paulo. Accessed January 24, 2020. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-08122011-154718/ ;.

MLA Handbook (7th Edition):

Oliveira, David Marçal Machado de. “Verificação do uso do dosímetro Fricke benzóico xilenol gel em tomografia computadorizada.” 2011. Web. 24 Jan 2020.

Vancouver:

Oliveira DMMd. Verificação do uso do dosímetro Fricke benzóico xilenol gel em tomografia computadorizada. [Internet] [Masters thesis]. University of São Paulo; 2011. [cited 2020 Jan 24]. Available from: http://www.teses.usp.br/teses/disponiveis/59/59135/tde-08122011-154718/ ;.

Council of Science Editors:

Oliveira DMMd. Verificação do uso do dosímetro Fricke benzóico xilenol gel em tomografia computadorizada. [Masters Thesis]. University of São Paulo; 2011. Available from: http://www.teses.usp.br/teses/disponiveis/59/59135/tde-08122011-154718/ ;

4. Moreira, Marcos Vasques. Dosimetria Fricke Xilenol Gel na região de não-equilíbrio para radioterapia com feixes de fótons e elétrons.

Degree: PhD, Física Aplicada à Medicina e Biologia, 2012, University of São Paulo

Quando se utiliza feixes de radiação ionizante de fótons e elétrons com altas energias, a região mais perto da superfície do paciente, região de não-equilíbrio,… (more)

Subjects/Keywords: Fricke Xilenol Gel; Fricke Xylenol Gel; No-equilibrium region; Radioterapia; Radiotherapy; Região de Não-Equilíbrio.

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Moreira, M. V. (2012). Dosimetria Fricke Xilenol Gel na região de não-equilíbrio para radioterapia com feixes de fótons e elétrons. (Doctoral Dissertation). University of São Paulo. Retrieved from http://www.teses.usp.br/teses/disponiveis/59/59135/tde-22072013-102348/ ;

Chicago Manual of Style (16th Edition):

Moreira, Marcos Vasques. “Dosimetria Fricke Xilenol Gel na região de não-equilíbrio para radioterapia com feixes de fótons e elétrons.” 2012. Doctoral Dissertation, University of São Paulo. Accessed January 24, 2020. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-22072013-102348/ ;.

MLA Handbook (7th Edition):

Moreira, Marcos Vasques. “Dosimetria Fricke Xilenol Gel na região de não-equilíbrio para radioterapia com feixes de fótons e elétrons.” 2012. Web. 24 Jan 2020.

Vancouver:

Moreira MV. Dosimetria Fricke Xilenol Gel na região de não-equilíbrio para radioterapia com feixes de fótons e elétrons. [Internet] [Doctoral dissertation]. University of São Paulo; 2012. [cited 2020 Jan 24]. Available from: http://www.teses.usp.br/teses/disponiveis/59/59135/tde-22072013-102348/ ;.

Council of Science Editors:

Moreira MV. Dosimetria Fricke Xilenol Gel na região de não-equilíbrio para radioterapia com feixes de fótons e elétrons. [Doctoral Dissertation]. University of São Paulo; 2012. Available from: http://www.teses.usp.br/teses/disponiveis/59/59135/tde-22072013-102348/ ;

5. Del Lama, Lucas Sacchini. Caracterização e adaptação do dosímetro Fricke para dosimetria em irradiação de sangue.

Degree: PhD, Física Aplicada à Medicina e Biologia, 2013, University of São Paulo

A Doença Enxerto Contra Hospedeiro Associada à Transfusão (DECH-AT) é uma reação transfusional rara, porém fatal, que ocorre devido à presença de células T no… (more)

Subjects/Keywords: Blood irradiation; controle de qualidade; dosimetria e Doença Enxerto Contra Hospedeiro Associada à Transfusão (DECH-AT); dosímetro Fricke Xilenol Gel; Dosimetry; Fricke Xylenol Gel dosimeter; Irradiação de sangue; Quality assurance; Transfusion-Associated Graft versus Host Disease (TA-GvHD)

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Del Lama, L. S. (2013). Caracterização e adaptação do dosímetro Fricke para dosimetria em irradiação de sangue. (Doctoral Dissertation). University of São Paulo. Retrieved from http://www.teses.usp.br/teses/disponiveis/59/59135/tde-11112013-115906/ ;

Chicago Manual of Style (16th Edition):

Del Lama, Lucas Sacchini. “Caracterização e adaptação do dosímetro Fricke para dosimetria em irradiação de sangue.” 2013. Doctoral Dissertation, University of São Paulo. Accessed January 24, 2020. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-11112013-115906/ ;.

MLA Handbook (7th Edition):

Del Lama, Lucas Sacchini. “Caracterização e adaptação do dosímetro Fricke para dosimetria em irradiação de sangue.” 2013. Web. 24 Jan 2020.

Vancouver:

Del Lama LS. Caracterização e adaptação do dosímetro Fricke para dosimetria em irradiação de sangue. [Internet] [Doctoral dissertation]. University of São Paulo; 2013. [cited 2020 Jan 24]. Available from: http://www.teses.usp.br/teses/disponiveis/59/59135/tde-11112013-115906/ ;.

Council of Science Editors:

Del Lama LS. Caracterização e adaptação do dosímetro Fricke para dosimetria em irradiação de sangue. [Doctoral Dissertation]. University of São Paulo; 2013. Available from: http://www.teses.usp.br/teses/disponiveis/59/59135/tde-11112013-115906/ ;

6. Sampaio, Francisco Glaildo Almeida. Avaliação de gap em feixes de fótons e elétrons na radioterapia utilizando o dosímetro Fricke Xilenol Gel e sistema de leitura CCD.

Degree: PhD, Física Aplicada à Medicina e Biologia, 2014, University of São Paulo

Em radioterapia, dependendo do tamanho do volume alvo a ser irradiado, pode ser necessário mais de um feixe de radiação (fótons ou elétrons). Isto faz… (more)

Subjects/Keywords: Adjacent Fields; Campos Adjacentes; Fricke Xilenol Gel; Fricke Xylenol Gel; Gap; Gap; Método Monte Carlo.; Monte Carlo Method.

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Sampaio, F. G. A. (2014). Avaliação de gap em feixes de fótons e elétrons na radioterapia utilizando o dosímetro Fricke Xilenol Gel e sistema de leitura CCD. (Doctoral Dissertation). University of São Paulo. Retrieved from http://www.teses.usp.br/teses/disponiveis/59/59135/tde-23052014-104532/ ;

Chicago Manual of Style (16th Edition):

Sampaio, Francisco Glaildo Almeida. “Avaliação de gap em feixes de fótons e elétrons na radioterapia utilizando o dosímetro Fricke Xilenol Gel e sistema de leitura CCD.” 2014. Doctoral Dissertation, University of São Paulo. Accessed January 24, 2020. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-23052014-104532/ ;.

MLA Handbook (7th Edition):

Sampaio, Francisco Glaildo Almeida. “Avaliação de gap em feixes de fótons e elétrons na radioterapia utilizando o dosímetro Fricke Xilenol Gel e sistema de leitura CCD.” 2014. Web. 24 Jan 2020.

Vancouver:

Sampaio FGA. Avaliação de gap em feixes de fótons e elétrons na radioterapia utilizando o dosímetro Fricke Xilenol Gel e sistema de leitura CCD. [Internet] [Doctoral dissertation]. University of São Paulo; 2014. [cited 2020 Jan 24]. Available from: http://www.teses.usp.br/teses/disponiveis/59/59135/tde-23052014-104532/ ;.

Council of Science Editors:

Sampaio FGA. Avaliação de gap em feixes de fótons e elétrons na radioterapia utilizando o dosímetro Fricke Xilenol Gel e sistema de leitura CCD. [Doctoral Dissertation]. University of São Paulo; 2014. Available from: http://www.teses.usp.br/teses/disponiveis/59/59135/tde-23052014-104532/ ;

7. Petchevist, Paulo Cesar Dias. Comissionamento dos parâmetros físicos dosimétricos em aceleradores lineares clínicos usando o dosímetro FXG.

Degree: PhD, Física Aplicada à Medicina e Biologia, 2015, University of São Paulo

A International Comission on Radiation Units and Measurements (ICRU) recomenda que a incerteza total de um tratamento radioterápico não deva ultrapassar de 5%, ou seja,… (more)

Subjects/Keywords: Acelerador Linear Clínico; Clinical Linear Accelerator; Comissionamento; Commissioning; Dosímetro FXG.; Fricke Xylenol Gel; Parâmetros físicos dosimétricos; Physical Dosimetric Parameters

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Petchevist, P. C. D. (2015). Comissionamento dos parâmetros físicos dosimétricos em aceleradores lineares clínicos usando o dosímetro FXG. (Doctoral Dissertation). University of São Paulo. Retrieved from http://www.teses.usp.br/teses/disponiveis/59/59135/tde-21072015-101409/ ;

Chicago Manual of Style (16th Edition):

Petchevist, Paulo Cesar Dias. “Comissionamento dos parâmetros físicos dosimétricos em aceleradores lineares clínicos usando o dosímetro FXG.” 2015. Doctoral Dissertation, University of São Paulo. Accessed January 24, 2020. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-21072015-101409/ ;.

MLA Handbook (7th Edition):

Petchevist, Paulo Cesar Dias. “Comissionamento dos parâmetros físicos dosimétricos em aceleradores lineares clínicos usando o dosímetro FXG.” 2015. Web. 24 Jan 2020.

Vancouver:

Petchevist PCD. Comissionamento dos parâmetros físicos dosimétricos em aceleradores lineares clínicos usando o dosímetro FXG. [Internet] [Doctoral dissertation]. University of São Paulo; 2015. [cited 2020 Jan 24]. Available from: http://www.teses.usp.br/teses/disponiveis/59/59135/tde-21072015-101409/ ;.

Council of Science Editors:

Petchevist PCD. Comissionamento dos parâmetros físicos dosimétricos em aceleradores lineares clínicos usando o dosímetro FXG. [Doctoral Dissertation]. University of São Paulo; 2015. Available from: http://www.teses.usp.br/teses/disponiveis/59/59135/tde-21072015-101409/ ;

8. Oliveira, Paulo Marcio de. Avaliação de dose nos sistemas de irradiação de bolsas de sangue para esterilização.

Degree: Mestrado, Tecnologia Nuclear - Aplicações, 2014, University of São Paulo

O procedimento de esterilização do sangue é adotado para que sejam mínimas as condições necessárias de manifestação da doença do enxertoversus- hospedeiro associada à transfusão… (more)

Subjects/Keywords: chemical dosimetry; dosimetria química; dosímetro Fricke Gel; Fricke Gel dosimeter; irradiação de bolsas de sangue; irradiação de hemocomponentes do sangue; irradiation of blood bags; irradiation of blood components from the blood

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Oliveira, P. M. d. (2014). Avaliação de dose nos sistemas de irradiação de bolsas de sangue para esterilização. (Masters Thesis). University of São Paulo. Retrieved from http://www.teses.usp.br/teses/disponiveis/85/85131/tde-14112014-142426/ ;

Chicago Manual of Style (16th Edition):

Oliveira, Paulo Marcio de. “Avaliação de dose nos sistemas de irradiação de bolsas de sangue para esterilização.” 2014. Masters Thesis, University of São Paulo. Accessed January 24, 2020. http://www.teses.usp.br/teses/disponiveis/85/85131/tde-14112014-142426/ ;.

MLA Handbook (7th Edition):

Oliveira, Paulo Marcio de. “Avaliação de dose nos sistemas de irradiação de bolsas de sangue para esterilização.” 2014. Web. 24 Jan 2020.

Vancouver:

Oliveira PMd. Avaliação de dose nos sistemas de irradiação de bolsas de sangue para esterilização. [Internet] [Masters thesis]. University of São Paulo; 2014. [cited 2020 Jan 24]. Available from: http://www.teses.usp.br/teses/disponiveis/85/85131/tde-14112014-142426/ ;.

Council of Science Editors:

Oliveira PMd. Avaliação de dose nos sistemas de irradiação de bolsas de sangue para esterilização. [Masters Thesis]. University of São Paulo; 2014. Available from: http://www.teses.usp.br/teses/disponiveis/85/85131/tde-14112014-142426/ ;


Queen Mary, University of London

9. Poxon, J. E. Translating 3D gel dosimetry research into clinical routine use in radiotherapy.

Degree: PhD, 2019, Queen Mary, University of London

 Radiotherapy involves the treatment of tumours with ionising radiation. Technological advances have improved the ability to conform dose distributions to tumours in three dimensions (3D)… (more)

Subjects/Keywords: Radiation; dosimetry; Fricke gel detectors

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Poxon, J. E. (2019). Translating 3D gel dosimetry research into clinical routine use in radiotherapy. (Doctoral Dissertation). Queen Mary, University of London. Retrieved from http://qmro.qmul.ac.uk/xmlui/handle/123456789/55452 ; https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.786348

Chicago Manual of Style (16th Edition):

Poxon, J E. “Translating 3D gel dosimetry research into clinical routine use in radiotherapy.” 2019. Doctoral Dissertation, Queen Mary, University of London. Accessed January 24, 2020. http://qmro.qmul.ac.uk/xmlui/handle/123456789/55452 ; https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.786348.

MLA Handbook (7th Edition):

Poxon, J E. “Translating 3D gel dosimetry research into clinical routine use in radiotherapy.” 2019. Web. 24 Jan 2020.

Vancouver:

Poxon JE. Translating 3D gel dosimetry research into clinical routine use in radiotherapy. [Internet] [Doctoral dissertation]. Queen Mary, University of London; 2019. [cited 2020 Jan 24]. Available from: http://qmro.qmul.ac.uk/xmlui/handle/123456789/55452 ; https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.786348.

Council of Science Editors:

Poxon JE. Translating 3D gel dosimetry research into clinical routine use in radiotherapy. [Doctoral Dissertation]. Queen Mary, University of London; 2019. Available from: http://qmro.qmul.ac.uk/xmlui/handle/123456789/55452 ; https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.786348

10. Capeleti, Felipe Favaro. Dosimetria em tomografia computadorizada e avaliação do perfil de dose empregando dosímetro Fricke gel e a técnica de imageamento por ressonância magnética.

Degree: Mestrado, Tecnologia Nuclear - Aplicações, 2014, University of São Paulo

Neste trabalho foi desenvolvido um novo método para a determinação das doses absorvidas nos exames de tomografia computadorizada, utilizando a dosimetria com Fricke gel desenvolvido… (more)

Subjects/Keywords: dose profile; Fricke Gel; Fricke Gel; Magnetic resonance; perfil de dose; ressonância magnética; tomografia; tomography

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Capeleti, F. F. (2014). Dosimetria em tomografia computadorizada e avaliação do perfil de dose empregando dosímetro Fricke gel e a técnica de imageamento por ressonância magnética. (Masters Thesis). University of São Paulo. Retrieved from http://www.teses.usp.br/teses/disponiveis/85/85131/tde-15102014-105653/ ;

Chicago Manual of Style (16th Edition):

Capeleti, Felipe Favaro. “Dosimetria em tomografia computadorizada e avaliação do perfil de dose empregando dosímetro Fricke gel e a técnica de imageamento por ressonância magnética.” 2014. Masters Thesis, University of São Paulo. Accessed January 24, 2020. http://www.teses.usp.br/teses/disponiveis/85/85131/tde-15102014-105653/ ;.

MLA Handbook (7th Edition):

Capeleti, Felipe Favaro. “Dosimetria em tomografia computadorizada e avaliação do perfil de dose empregando dosímetro Fricke gel e a técnica de imageamento por ressonância magnética.” 2014. Web. 24 Jan 2020.

Vancouver:

Capeleti FF. Dosimetria em tomografia computadorizada e avaliação do perfil de dose empregando dosímetro Fricke gel e a técnica de imageamento por ressonância magnética. [Internet] [Masters thesis]. University of São Paulo; 2014. [cited 2020 Jan 24]. Available from: http://www.teses.usp.br/teses/disponiveis/85/85131/tde-15102014-105653/ ;.

Council of Science Editors:

Capeleti FF. Dosimetria em tomografia computadorizada e avaliação do perfil de dose empregando dosímetro Fricke gel e a técnica de imageamento por ressonância magnética. [Masters Thesis]. University of São Paulo; 2014. Available from: http://www.teses.usp.br/teses/disponiveis/85/85131/tde-15102014-105653/ ;

11. Silveira, Michely Cristina da. Distribuição da dose absorvida no tratamento da micose fungóide através da dosimetria Fricke Xilenol Gel.

Degree: Mestrado, Física Aplicada à Medicina e Biologia, 2010, University of São Paulo

A radioterapia utiliza a radiação ionizante para a destruição de células tumorais. O controle da dose absorvida de um tipo específico de radiação aplicada a… (more)

Subjects/Keywords: Dosimetria e Dosímetro Fricke Xilenol Gel; Dosimetry; Fricke Xilenol Gel Dosimete.; Radioterapia; Radioterapy

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Silveira, M. C. d. (2010). Distribuição da dose absorvida no tratamento da micose fungóide através da dosimetria Fricke Xilenol Gel. (Masters Thesis). University of São Paulo. Retrieved from http://www.teses.usp.br/teses/disponiveis/59/59135/tde-04032011-155301/ ;

Chicago Manual of Style (16th Edition):

Silveira, Michely Cristina da. “Distribuição da dose absorvida no tratamento da micose fungóide através da dosimetria Fricke Xilenol Gel.” 2010. Masters Thesis, University of São Paulo. Accessed January 24, 2020. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-04032011-155301/ ;.

MLA Handbook (7th Edition):

Silveira, Michely Cristina da. “Distribuição da dose absorvida no tratamento da micose fungóide através da dosimetria Fricke Xilenol Gel.” 2010. Web. 24 Jan 2020.

Vancouver:

Silveira MCd. Distribuição da dose absorvida no tratamento da micose fungóide através da dosimetria Fricke Xilenol Gel. [Internet] [Masters thesis]. University of São Paulo; 2010. [cited 2020 Jan 24]. Available from: http://www.teses.usp.br/teses/disponiveis/59/59135/tde-04032011-155301/ ;.

Council of Science Editors:

Silveira MCd. Distribuição da dose absorvida no tratamento da micose fungóide através da dosimetria Fricke Xilenol Gel. [Masters Thesis]. University of São Paulo; 2010. Available from: http://www.teses.usp.br/teses/disponiveis/59/59135/tde-04032011-155301/ ;


Université de Sherbrooke

12. Plante, Ianik. Développement de codes de simulation Monte-Carlo de la radiolyse de l'eau par des électrons, ions lourds, photons et neutrons applications à divers sujets d'intérêt expérimental .

Degree: 2008, Université de Sherbrooke

 Water is a major component of living organisms, which can be 70-85% of the weight of cells. For this reason, water is a main target… (more)

Subjects/Keywords: Chemical evolution; Dose-rate; Ceric dosimeter; Fricke dosimeter; Non-homogeneous chemistry; Radiation transport codes; Monte-Carlo simulations; Water radiolysis

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Plante, I. (2008). Développement de codes de simulation Monte-Carlo de la radiolyse de l'eau par des électrons, ions lourds, photons et neutrons applications à divers sujets d'intérêt expérimental . (Doctoral Dissertation). Université de Sherbrooke. Retrieved from http://savoirs.usherbrooke.ca/handle/11143/4292

Chicago Manual of Style (16th Edition):

Plante, Ianik. “Développement de codes de simulation Monte-Carlo de la radiolyse de l'eau par des électrons, ions lourds, photons et neutrons applications à divers sujets d'intérêt expérimental .” 2008. Doctoral Dissertation, Université de Sherbrooke. Accessed January 24, 2020. http://savoirs.usherbrooke.ca/handle/11143/4292.

MLA Handbook (7th Edition):

Plante, Ianik. “Développement de codes de simulation Monte-Carlo de la radiolyse de l'eau par des électrons, ions lourds, photons et neutrons applications à divers sujets d'intérêt expérimental .” 2008. Web. 24 Jan 2020.

Vancouver:

Plante I. Développement de codes de simulation Monte-Carlo de la radiolyse de l'eau par des électrons, ions lourds, photons et neutrons applications à divers sujets d'intérêt expérimental . [Internet] [Doctoral dissertation]. Université de Sherbrooke; 2008. [cited 2020 Jan 24]. Available from: http://savoirs.usherbrooke.ca/handle/11143/4292.

Council of Science Editors:

Plante I. Développement de codes de simulation Monte-Carlo de la radiolyse de l'eau par des électrons, ions lourds, photons et neutrons applications à divers sujets d'intérêt expérimental . [Doctoral Dissertation]. Université de Sherbrooke; 2008. Available from: http://savoirs.usherbrooke.ca/handle/11143/4292


RMIT University

13. W Abd Rahman, W. Gold nanoparticles: novel radiobiological dose enhancement studies for radiation therapy, synchrotron based microbeam and stereotactic radiotherapy.

Degree: 2010, RMIT University

 High atomic number (Z) materials such as iodine and gadolinium have been successfully used as dose enhancers in preclinical radiotherapy. A competing high Z dose… (more)

Subjects/Keywords: Fields of Research; Gold Nanoparticles; Radiotherapy; Polymer Gel Dosimeter; Synchrotron Radiation

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

W Abd Rahman, W. (2010). Gold nanoparticles: novel radiobiological dose enhancement studies for radiation therapy, synchrotron based microbeam and stereotactic radiotherapy. (Thesis). RMIT University. Retrieved from http://researchbank.rmit.edu.au/view/rmit:11218

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

W Abd Rahman, W. “Gold nanoparticles: novel radiobiological dose enhancement studies for radiation therapy, synchrotron based microbeam and stereotactic radiotherapy.” 2010. Thesis, RMIT University. Accessed January 24, 2020. http://researchbank.rmit.edu.au/view/rmit:11218.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

W Abd Rahman, W. “Gold nanoparticles: novel radiobiological dose enhancement studies for radiation therapy, synchrotron based microbeam and stereotactic radiotherapy.” 2010. Web. 24 Jan 2020.

Vancouver:

W Abd Rahman W. Gold nanoparticles: novel radiobiological dose enhancement studies for radiation therapy, synchrotron based microbeam and stereotactic radiotherapy. [Internet] [Thesis]. RMIT University; 2010. [cited 2020 Jan 24]. Available from: http://researchbank.rmit.edu.au/view/rmit:11218.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

W Abd Rahman W. Gold nanoparticles: novel radiobiological dose enhancement studies for radiation therapy, synchrotron based microbeam and stereotactic radiotherapy. [Thesis]. RMIT University; 2010. Available from: http://researchbank.rmit.edu.au/view/rmit:11218

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

14. Cavinato, Christianne Cobello. Padronização do método de dosimetria Fricke gel e avaliação tridimensional de dose empregando a técnica de imageamento por ressonância magnética.

Degree: Mestrado, Tecnologia Nuclear - Aplicações, 2009, University of São Paulo

Neste trabalho foi padronizado o método de obtenção da solução Fricke gel desenvolvida no IPEN. Foram comparados os resultados obtidos para diferentes qualidades do gel(more)

Subjects/Keywords: Dosimetria Fricke gel; Dosimetria Fricke gel; gelatina 270 Bloom; gelatina 270 Bloom; Imageamento por Ressonância Magnética (IRM).; Imageamento por ressonância magnética (IRM).

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Cavinato, C. C. (2009). Padronização do método de dosimetria Fricke gel e avaliação tridimensional de dose empregando a técnica de imageamento por ressonância magnética. (Masters Thesis). University of São Paulo. Retrieved from http://www.teses.usp.br/teses/disponiveis/85/85131/tde-05112009-102509/ ;

Chicago Manual of Style (16th Edition):

Cavinato, Christianne Cobello. “Padronização do método de dosimetria Fricke gel e avaliação tridimensional de dose empregando a técnica de imageamento por ressonância magnética.” 2009. Masters Thesis, University of São Paulo. Accessed January 24, 2020. http://www.teses.usp.br/teses/disponiveis/85/85131/tde-05112009-102509/ ;.

MLA Handbook (7th Edition):

Cavinato, Christianne Cobello. “Padronização do método de dosimetria Fricke gel e avaliação tridimensional de dose empregando a técnica de imageamento por ressonância magnética.” 2009. Web. 24 Jan 2020.

Vancouver:

Cavinato CC. Padronização do método de dosimetria Fricke gel e avaliação tridimensional de dose empregando a técnica de imageamento por ressonância magnética. [Internet] [Masters thesis]. University of São Paulo; 2009. [cited 2020 Jan 24]. Available from: http://www.teses.usp.br/teses/disponiveis/85/85131/tde-05112009-102509/ ;.

Council of Science Editors:

Cavinato CC. Padronização do método de dosimetria Fricke gel e avaliação tridimensional de dose empregando a técnica de imageamento por ressonância magnética. [Masters Thesis]. University of São Paulo; 2009. Available from: http://www.teses.usp.br/teses/disponiveis/85/85131/tde-05112009-102509/ ;


Wright State University

15. Courter, Erik Joseph-Leonard. Use of ClearView Gel Dosimeter for Quality Assurance and Testing of Stereotactic Radiosurgery.

Degree: MS, Physics, 2016, Wright State University

 There exists a lack of accurate, reproducible three-dimensional dosimetry techniques for stereotactic radiosurgery (SRS) commissioning and quality assurance. This experiment evaluates the use of ClearView… (more)

Subjects/Keywords: Physics; ClearView; gel dosimeter; stereotactic radiosurgery; SRS; quality assurance; small field dosimetry

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Courter, E. J. (2016). Use of ClearView Gel Dosimeter for Quality Assurance and Testing of Stereotactic Radiosurgery. (Masters Thesis). Wright State University. Retrieved from http://rave.ohiolink.edu/etdc/view?acc_num=wright1466417256

Chicago Manual of Style (16th Edition):

Courter, Erik Joseph-Leonard. “Use of ClearView Gel Dosimeter for Quality Assurance and Testing of Stereotactic Radiosurgery.” 2016. Masters Thesis, Wright State University. Accessed January 24, 2020. http://rave.ohiolink.edu/etdc/view?acc_num=wright1466417256.

MLA Handbook (7th Edition):

Courter, Erik Joseph-Leonard. “Use of ClearView Gel Dosimeter for Quality Assurance and Testing of Stereotactic Radiosurgery.” 2016. Web. 24 Jan 2020.

Vancouver:

Courter EJ. Use of ClearView Gel Dosimeter for Quality Assurance and Testing of Stereotactic Radiosurgery. [Internet] [Masters thesis]. Wright State University; 2016. [cited 2020 Jan 24]. Available from: http://rave.ohiolink.edu/etdc/view?acc_num=wright1466417256.

Council of Science Editors:

Courter EJ. Use of ClearView Gel Dosimeter for Quality Assurance and Testing of Stereotactic Radiosurgery. [Masters Thesis]. Wright State University; 2016. Available from: http://rave.ohiolink.edu/etdc/view?acc_num=wright1466417256


McMaster University

16. Eyadeh, Molham. The Development of a Transparent Poly(vinyl alcohol) Radiochromic Cryogel Dosimeter and Optical Detection Methods.

Degree: PhD, 2015, McMaster University

In radiation therapy, gel dosimetry is used to measure radiation doses for treatment verification. Gel dosimeters have the ability to record dose information in three… (more)

Subjects/Keywords: Gel Dosimetry; Radiation Dosimetry; Radiochromic Dosimeter; Radiotherapy; Poly(vinyl Alcohol)PVA; Cryogel

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Eyadeh, M. (2015). The Development of a Transparent Poly(vinyl alcohol) Radiochromic Cryogel Dosimeter and Optical Detection Methods. (Doctoral Dissertation). McMaster University. Retrieved from http://hdl.handle.net/11375/18634

Chicago Manual of Style (16th Edition):

Eyadeh, Molham. “The Development of a Transparent Poly(vinyl alcohol) Radiochromic Cryogel Dosimeter and Optical Detection Methods.” 2015. Doctoral Dissertation, McMaster University. Accessed January 24, 2020. http://hdl.handle.net/11375/18634.

MLA Handbook (7th Edition):

Eyadeh, Molham. “The Development of a Transparent Poly(vinyl alcohol) Radiochromic Cryogel Dosimeter and Optical Detection Methods.” 2015. Web. 24 Jan 2020.

Vancouver:

Eyadeh M. The Development of a Transparent Poly(vinyl alcohol) Radiochromic Cryogel Dosimeter and Optical Detection Methods. [Internet] [Doctoral dissertation]. McMaster University; 2015. [cited 2020 Jan 24]. Available from: http://hdl.handle.net/11375/18634.

Council of Science Editors:

Eyadeh M. The Development of a Transparent Poly(vinyl alcohol) Radiochromic Cryogel Dosimeter and Optical Detection Methods. [Doctoral Dissertation]. McMaster University; 2015. Available from: http://hdl.handle.net/11375/18634


McMaster University

17. Al Rashed, Hailah. THE DEVELOPMENT OF A LOW DENSITY RADIOCHROMIC GEL DOSIMETER.

Degree: MSc, 2019, McMaster University

This research aims to develop a tissue-mimicking material and produce a 3D gelatin that has density of approximately a human lung, which is in the… (more)

Subjects/Keywords: Gel Dosimetry; Radiation Dosimetry; Radiochromic Dosimeter; Radiotherapy; Quality Assurance (QA); Gelatin; Two dimensional; Three dimensional

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Al Rashed, H. (2019). THE DEVELOPMENT OF A LOW DENSITY RADIOCHROMIC GEL DOSIMETER. (Masters Thesis). McMaster University. Retrieved from http://hdl.handle.net/11375/24092

Chicago Manual of Style (16th Edition):

Al Rashed, Hailah. “THE DEVELOPMENT OF A LOW DENSITY RADIOCHROMIC GEL DOSIMETER.” 2019. Masters Thesis, McMaster University. Accessed January 24, 2020. http://hdl.handle.net/11375/24092.

MLA Handbook (7th Edition):

Al Rashed, Hailah. “THE DEVELOPMENT OF A LOW DENSITY RADIOCHROMIC GEL DOSIMETER.” 2019. Web. 24 Jan 2020.

Vancouver:

Al Rashed H. THE DEVELOPMENT OF A LOW DENSITY RADIOCHROMIC GEL DOSIMETER. [Internet] [Masters thesis]. McMaster University; 2019. [cited 2020 Jan 24]. Available from: http://hdl.handle.net/11375/24092.

Council of Science Editors:

Al Rashed H. THE DEVELOPMENT OF A LOW DENSITY RADIOCHROMIC GEL DOSIMETER. [Masters Thesis]. McMaster University; 2019. Available from: http://hdl.handle.net/11375/24092

18. Mirsaleh Kohan, Leila. Comparison of the Effects of Cobalt-60 [gamma]-Rays and Tritium [beta][superscript -]Particles on Water Radiolysis and Aqueous Solutions and Radiolysis of the Ceric-Cerous Sulfate Dosimeter at Elevated Temperature.

Degree: M. Sc., Sciences des radiations et imagerie biomédicale, 2014, Université de Sherbrooke

 Abstract : Monte Carlo simulations have proven to be very powerful techniques to study the radiolysis of water and the mechanisms underlying this radiolysis. Monte… (more)

Subjects/Keywords: Radiolysis of water; Monte Carlo simulation; Tritiated water; G-values; Free radical and molecular yields; LET; Fricke dosimeter; Ceric-cerous sulfate dosimeter; Track structure; [superscript 3]H [béta Minuscule][superscript -] rays; [superscript 60]Co [gamma Minuscule]-rays; Radiolyse de l'eau; Simulation Monte-Carlo; Eau tritiée; Particules [béta Minuscule][indice supérieur -] de [indice supérieur 3]H; Rayons [gamma Minuscule] de [indice supérieur 60]Co; Radicaux libres et produits moléculaires; Dosimètre de Fricke; Dosimètre au sulfate cérique-céreux; Structure de trajectoires

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Mirsaleh Kohan, L. (2014). Comparison of the Effects of Cobalt-60 [gamma]-Rays and Tritium [beta][superscript -]Particles on Water Radiolysis and Aqueous Solutions and Radiolysis of the Ceric-Cerous Sulfate Dosimeter at Elevated Temperature. (Masters Thesis). Université de Sherbrooke. Retrieved from http://www.collectionscanada.gc.ca/obj/thesescanada/vol2/QSHERU/TC-QSHERU-11143_168.pdf ; http://savoirs.usherbrooke.ca/bitstream/11143/168/1/Mirsaleh_Kohan_Leila_MSc_2014.pdf

Chicago Manual of Style (16th Edition):

Mirsaleh Kohan, Leila. “Comparison of the Effects of Cobalt-60 [gamma]-Rays and Tritium [beta][superscript -]Particles on Water Radiolysis and Aqueous Solutions and Radiolysis of the Ceric-Cerous Sulfate Dosimeter at Elevated Temperature.” 2014. Masters Thesis, Université de Sherbrooke. Accessed January 24, 2020. http://www.collectionscanada.gc.ca/obj/thesescanada/vol2/QSHERU/TC-QSHERU-11143_168.pdf ; http://savoirs.usherbrooke.ca/bitstream/11143/168/1/Mirsaleh_Kohan_Leila_MSc_2014.pdf.

MLA Handbook (7th Edition):

Mirsaleh Kohan, Leila. “Comparison of the Effects of Cobalt-60 [gamma]-Rays and Tritium [beta][superscript -]Particles on Water Radiolysis and Aqueous Solutions and Radiolysis of the Ceric-Cerous Sulfate Dosimeter at Elevated Temperature.” 2014. Web. 24 Jan 2020.

Vancouver:

Mirsaleh Kohan L. Comparison of the Effects of Cobalt-60 [gamma]-Rays and Tritium [beta][superscript -]Particles on Water Radiolysis and Aqueous Solutions and Radiolysis of the Ceric-Cerous Sulfate Dosimeter at Elevated Temperature. [Internet] [Masters thesis]. Université de Sherbrooke; 2014. [cited 2020 Jan 24]. Available from: http://www.collectionscanada.gc.ca/obj/thesescanada/vol2/QSHERU/TC-QSHERU-11143_168.pdf ; http://savoirs.usherbrooke.ca/bitstream/11143/168/1/Mirsaleh_Kohan_Leila_MSc_2014.pdf.

Council of Science Editors:

Mirsaleh Kohan L. Comparison of the Effects of Cobalt-60 [gamma]-Rays and Tritium [beta][superscript -]Particles on Water Radiolysis and Aqueous Solutions and Radiolysis of the Ceric-Cerous Sulfate Dosimeter at Elevated Temperature. [Masters Thesis]. Université de Sherbrooke; 2014. Available from: http://www.collectionscanada.gc.ca/obj/thesescanada/vol2/QSHERU/TC-QSHERU-11143_168.pdf ; http://savoirs.usherbrooke.ca/bitstream/11143/168/1/Mirsaleh_Kohan_Leila_MSc_2014.pdf


Université de Sherbrooke

19. Mirsaleh Kohan, Leila. Comparison of the Effects of Cobalt-60 [gamma]-Rays and Tritium [beta][superscript -]Particles on Water Radiolysis and Aqueous Solutions and Radiolysis of the Ceric-Cerous Sulfate Dosimeter at Elevated Temperature .

Degree: 2014, Université de Sherbrooke

 Abstract : Monte Carlo simulations have proven to be very powerful techniques to study the radiolysis of water and the mechanisms underlying this radiolysis. Monte… (more)

Subjects/Keywords: Radiolysis of water; Monte Carlo simulation; Tritiated water; G-values; Free radical and molecular yields; LET; Fricke dosimeter; Ceric-cerous sulfate dosimeter; Track structure; [superscript 3]H [béta Minuscule][superscript -] rays; [superscript 60]Co [gamma Minuscule]-rays; Radiolyse de l'eau; Simulation Monte-Carlo; Eau tritiée; Particules [béta Minuscule][indice supérieur -] de [indice supérieur 3]H; Rayons [gamma Minuscule] de [indice supérieur 60]Co; Radicaux libres et produits moléculaires; Dosimètre de Fricke; Dosimètre au sulfate cérique-céreux; Structure de trajectoires

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Mirsaleh Kohan, L. (2014). Comparison of the Effects of Cobalt-60 [gamma]-Rays and Tritium [beta][superscript -]Particles on Water Radiolysis and Aqueous Solutions and Radiolysis of the Ceric-Cerous Sulfate Dosimeter at Elevated Temperature . (Masters Thesis). Université de Sherbrooke. Retrieved from http://savoirs.usherbrooke.ca/handle/11143/168

Chicago Manual of Style (16th Edition):

Mirsaleh Kohan, Leila. “Comparison of the Effects of Cobalt-60 [gamma]-Rays and Tritium [beta][superscript -]Particles on Water Radiolysis and Aqueous Solutions and Radiolysis of the Ceric-Cerous Sulfate Dosimeter at Elevated Temperature .” 2014. Masters Thesis, Université de Sherbrooke. Accessed January 24, 2020. http://savoirs.usherbrooke.ca/handle/11143/168.

MLA Handbook (7th Edition):

Mirsaleh Kohan, Leila. “Comparison of the Effects of Cobalt-60 [gamma]-Rays and Tritium [beta][superscript -]Particles on Water Radiolysis and Aqueous Solutions and Radiolysis of the Ceric-Cerous Sulfate Dosimeter at Elevated Temperature .” 2014. Web. 24 Jan 2020.

Vancouver:

Mirsaleh Kohan L. Comparison of the Effects of Cobalt-60 [gamma]-Rays and Tritium [beta][superscript -]Particles on Water Radiolysis and Aqueous Solutions and Radiolysis of the Ceric-Cerous Sulfate Dosimeter at Elevated Temperature . [Internet] [Masters thesis]. Université de Sherbrooke; 2014. [cited 2020 Jan 24]. Available from: http://savoirs.usherbrooke.ca/handle/11143/168.

Council of Science Editors:

Mirsaleh Kohan L. Comparison of the Effects of Cobalt-60 [gamma]-Rays and Tritium [beta][superscript -]Particles on Water Radiolysis and Aqueous Solutions and Radiolysis of the Ceric-Cerous Sulfate Dosimeter at Elevated Temperature . [Masters Thesis]. Université de Sherbrooke; 2014. Available from: http://savoirs.usherbrooke.ca/handle/11143/168


Queensland University of Technology

20. Zahmatkesh, Mohammed. Dosimetry of ionising radiation with ferrous and xylenol orange infused gels.

Degree: 1998, Queensland University of Technology

Subjects/Keywords: Chemical dosimetry; Radiation dosimetry; Ionizing radiation Measurement; chemical dosimetry; ionising radiation; optical density measurement; agarose; gelatin; xylenol orange dye; Fricke dosimetry; radiation dosimetry; thesis; doctoral

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Zahmatkesh, M. (1998). Dosimetry of ionising radiation with ferrous and xylenol orange infused gels. (Thesis). Queensland University of Technology. Retrieved from http://eprints.qut.edu.au/36980/

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Zahmatkesh, Mohammed. “Dosimetry of ionising radiation with ferrous and xylenol orange infused gels.” 1998. Thesis, Queensland University of Technology. Accessed January 24, 2020. http://eprints.qut.edu.au/36980/.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Zahmatkesh, Mohammed. “Dosimetry of ionising radiation with ferrous and xylenol orange infused gels.” 1998. Web. 24 Jan 2020.

Vancouver:

Zahmatkesh M. Dosimetry of ionising radiation with ferrous and xylenol orange infused gels. [Internet] [Thesis]. Queensland University of Technology; 1998. [cited 2020 Jan 24]. Available from: http://eprints.qut.edu.au/36980/.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Zahmatkesh M. Dosimetry of ionising radiation with ferrous and xylenol orange infused gels. [Thesis]. Queensland University of Technology; 1998. Available from: http://eprints.qut.edu.au/36980/

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

21. Alva Sánchez, Mirko Salomón. Verificação 3D da distribuição da dose em radiocirurgia estereotáxica através de simulação Monte Carlo e dosimetria por ressonância magnética nuclear.

Degree: PhD, Física Aplicada à Medicina e Biologia, 2012, University of São Paulo

A radiocirugia estereotáxica é uma técnica que fornece altas doses de radiação utilizando campos pequenos para conformação da dose no volume alvo do tratamento. Devido… (more)

Subjects/Keywords: Dosimetria 3D; dosimetro MAGIC-f gel; Dosimetry in 3D; Filme Radiocrômico; MAGIC-f gel dosimeter; PENELOPE-Monte Carlo; PENELOPE-Monte Carlo; Radiochromic film.; Radiocirurgia Estereotáxica; Stereotactic Radiosurgery

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Alva Sánchez, M. S. (2012). Verificação 3D da distribuição da dose em radiocirurgia estereotáxica através de simulação Monte Carlo e dosimetria por ressonância magnética nuclear. (Doctoral Dissertation). University of São Paulo. Retrieved from http://www.teses.usp.br/teses/disponiveis/59/59135/tde-15052013-193530/ ;

Chicago Manual of Style (16th Edition):

Alva Sánchez, Mirko Salomón. “Verificação 3D da distribuição da dose em radiocirurgia estereotáxica através de simulação Monte Carlo e dosimetria por ressonância magnética nuclear.” 2012. Doctoral Dissertation, University of São Paulo. Accessed January 24, 2020. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-15052013-193530/ ;.

MLA Handbook (7th Edition):

Alva Sánchez, Mirko Salomón. “Verificação 3D da distribuição da dose em radiocirurgia estereotáxica através de simulação Monte Carlo e dosimetria por ressonância magnética nuclear.” 2012. Web. 24 Jan 2020.

Vancouver:

Alva Sánchez MS. Verificação 3D da distribuição da dose em radiocirurgia estereotáxica através de simulação Monte Carlo e dosimetria por ressonância magnética nuclear. [Internet] [Doctoral dissertation]. University of São Paulo; 2012. [cited 2020 Jan 24]. Available from: http://www.teses.usp.br/teses/disponiveis/59/59135/tde-15052013-193530/ ;.

Council of Science Editors:

Alva Sánchez MS. Verificação 3D da distribuição da dose em radiocirurgia estereotáxica através de simulação Monte Carlo e dosimetria por ressonância magnética nuclear. [Doctoral Dissertation]. University of São Paulo; 2012. Available from: http://www.teses.usp.br/teses/disponiveis/59/59135/tde-15052013-193530/ ;


Université de Sherbrooke

22. Tippayamontri, Thititip. Simulation Monte-Carlo de la radiolyse du dosimètre de Fricke par des neutrons rapides .

Degree: 2009, Université de Sherbrooke

 Monte-Carlo calculations are used to simulate the stochastic effects of fast neutron-induced chemical changes in the radiolysis of the ferrous sulfate (Fricke) dosimeter. To study… (more)

Subjects/Keywords: Monte-Carlo simulations; Temperature; Time scale for spur expansion; Kinetics of formation and yield of Fe[superscript 3+] ions; Fricke (ferrous sulfate) dosimeter; Free-radical and molecular yields; Linear energy transfer (LET); Recoil jons (protons and oxygen ions); Fast neutrons; Radiolysis; Aerated sulfuric acid aqueous solutions; Liquid water

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Tippayamontri, T. (2009). Simulation Monte-Carlo de la radiolyse du dosimètre de Fricke par des neutrons rapides . (Masters Thesis). Université de Sherbrooke. Retrieved from http://savoirs.usherbrooke.ca/handle/11143/4013

Chicago Manual of Style (16th Edition):

Tippayamontri, Thititip. “Simulation Monte-Carlo de la radiolyse du dosimètre de Fricke par des neutrons rapides .” 2009. Masters Thesis, Université de Sherbrooke. Accessed January 24, 2020. http://savoirs.usherbrooke.ca/handle/11143/4013.

MLA Handbook (7th Edition):

Tippayamontri, Thititip. “Simulation Monte-Carlo de la radiolyse du dosimètre de Fricke par des neutrons rapides .” 2009. Web. 24 Jan 2020.

Vancouver:

Tippayamontri T. Simulation Monte-Carlo de la radiolyse du dosimètre de Fricke par des neutrons rapides . [Internet] [Masters thesis]. Université de Sherbrooke; 2009. [cited 2020 Jan 24]. Available from: http://savoirs.usherbrooke.ca/handle/11143/4013.

Council of Science Editors:

Tippayamontri T. Simulation Monte-Carlo de la radiolyse du dosimètre de Fricke par des neutrons rapides . [Masters Thesis]. Université de Sherbrooke; 2009. Available from: http://savoirs.usherbrooke.ca/handle/11143/4013


McMaster University

23. Ataei, Pouria. DEVELOPMENT OF A TRANSPARENT AND DEFORMABLE TWO DIMENSIONAL RADIOCHROMIC GEL DOSIMETER.

Degree: MSc, 2012, McMaster University

  Radiotherapy is used in many clinics to deliver a sufficient and uniform dose to the cancerous tumours while the dose to normal tissues is… (more)

Subjects/Keywords: Gel Dosimetry; Radiochromic Dosimeter; Radiotherapy; Quality Assurance (QA) Leucomalachite Green (LMG); Poly(vinyl Alcohol) PVA; Gelatin; Micelle; Two dimensional; Medicine and Health Sciences; Physics; Medicine and Health Sciences

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Ataei, P. (2012). DEVELOPMENT OF A TRANSPARENT AND DEFORMABLE TWO DIMENSIONAL RADIOCHROMIC GEL DOSIMETER. (Masters Thesis). McMaster University. Retrieved from http://hdl.handle.net/11375/11790

Chicago Manual of Style (16th Edition):

Ataei, Pouria. “DEVELOPMENT OF A TRANSPARENT AND DEFORMABLE TWO DIMENSIONAL RADIOCHROMIC GEL DOSIMETER.” 2012. Masters Thesis, McMaster University. Accessed January 24, 2020. http://hdl.handle.net/11375/11790.

MLA Handbook (7th Edition):

Ataei, Pouria. “DEVELOPMENT OF A TRANSPARENT AND DEFORMABLE TWO DIMENSIONAL RADIOCHROMIC GEL DOSIMETER.” 2012. Web. 24 Jan 2020.

Vancouver:

Ataei P. DEVELOPMENT OF A TRANSPARENT AND DEFORMABLE TWO DIMENSIONAL RADIOCHROMIC GEL DOSIMETER. [Internet] [Masters thesis]. McMaster University; 2012. [cited 2020 Jan 24]. Available from: http://hdl.handle.net/11375/11790.

Council of Science Editors:

Ataei P. DEVELOPMENT OF A TRANSPARENT AND DEFORMABLE TWO DIMENSIONAL RADIOCHROMIC GEL DOSIMETER. [Masters Thesis]. McMaster University; 2012. Available from: http://hdl.handle.net/11375/11790


Queens University

24. Smith, Mandy. Improved recipes for leuco-crystal violet micelle gel dosimeters .

Degree: Chemical Engineering, Queens University

 An optimized recipe for a radiochromic micelle (RM) leuco-crystal violet (LCV) gel dosimeter was proposed using full-factorial designed experiments and model-based optimization. Linear regression models… (more)

Subjects/Keywords: Micelle Gel Dosimeter; Radiation Therapy; Design of Experiments; Leuco Crystal Violet

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Smith, M. (n.d.). Improved recipes for leuco-crystal violet micelle gel dosimeters . (Thesis). Queens University. Retrieved from http://hdl.handle.net/1974/26409

Note: this citation may be lacking information needed for this citation format:
No year of publication.
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Smith, Mandy. “Improved recipes for leuco-crystal violet micelle gel dosimeters .” Thesis, Queens University. Accessed January 24, 2020. http://hdl.handle.net/1974/26409.

Note: this citation may be lacking information needed for this citation format:
No year of publication.
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Smith, Mandy. “Improved recipes for leuco-crystal violet micelle gel dosimeters .” Web. 24 Jan 2020.

Note: this citation may be lacking information needed for this citation format:
No year of publication.

Vancouver:

Smith M. Improved recipes for leuco-crystal violet micelle gel dosimeters . [Internet] [Thesis]. Queens University; [cited 2020 Jan 24]. Available from: http://hdl.handle.net/1974/26409.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
No year of publication.

Council of Science Editors:

Smith M. Improved recipes for leuco-crystal violet micelle gel dosimeters . [Thesis]. Queens University; Available from: http://hdl.handle.net/1974/26409

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation
No year of publication.


Victoria University of Wellington

25. Gädtke, Christin. Advanced Materials for Radiation Dosimetry.

Degree: 2014, Victoria University of Wellington

 The motivation for this work was to find materials that have the following characteristics: good optical transparency, rapid read-out, automation of read-out, good fading characteristic,… (more)

Subjects/Keywords: Fluoroperovskites; Luminescence; Dosimeter

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Gädtke, C. (2014). Advanced Materials for Radiation Dosimetry. (Doctoral Dissertation). Victoria University of Wellington. Retrieved from http://hdl.handle.net/10063/3298

Chicago Manual of Style (16th Edition):

Gädtke, Christin. “Advanced Materials for Radiation Dosimetry.” 2014. Doctoral Dissertation, Victoria University of Wellington. Accessed January 24, 2020. http://hdl.handle.net/10063/3298.

MLA Handbook (7th Edition):

Gädtke, Christin. “Advanced Materials for Radiation Dosimetry.” 2014. Web. 24 Jan 2020.

Vancouver:

Gädtke C. Advanced Materials for Radiation Dosimetry. [Internet] [Doctoral dissertation]. Victoria University of Wellington; 2014. [cited 2020 Jan 24]. Available from: http://hdl.handle.net/10063/3298.

Council of Science Editors:

Gädtke C. Advanced Materials for Radiation Dosimetry. [Doctoral Dissertation]. Victoria University of Wellington; 2014. Available from: http://hdl.handle.net/10063/3298

26. PEDROSA, Guilherme Andrade Campos. Utilização do dosímetro Fricke para dosimetria de máquinas teleterapêuticas, irradiadores gammacel e aparelhos de raios-X superficiais .

Degree: 2006, Universidade Federal de Pernambuco

 A dosimetria química tem sido utilizada como referência na medida da dose absorvida, com o dosimetro Fricke, em laboratórios de padronização. Este dosímetro é considerado… (more)

Subjects/Keywords: Dosimetria Fricke

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

PEDROSA, G. A. C. (2006). Utilização do dosímetro Fricke para dosimetria de máquinas teleterapêuticas, irradiadores gammacel e aparelhos de raios-X superficiais . (Thesis). Universidade Federal de Pernambuco. Retrieved from http://repositorio.ufpe.br/handle/123456789/9942

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

PEDROSA, Guilherme Andrade Campos. “Utilização do dosímetro Fricke para dosimetria de máquinas teleterapêuticas, irradiadores gammacel e aparelhos de raios-X superficiais .” 2006. Thesis, Universidade Federal de Pernambuco. Accessed January 24, 2020. http://repositorio.ufpe.br/handle/123456789/9942.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

PEDROSA, Guilherme Andrade Campos. “Utilização do dosímetro Fricke para dosimetria de máquinas teleterapêuticas, irradiadores gammacel e aparelhos de raios-X superficiais .” 2006. Web. 24 Jan 2020.

Vancouver:

PEDROSA GAC. Utilização do dosímetro Fricke para dosimetria de máquinas teleterapêuticas, irradiadores gammacel e aparelhos de raios-X superficiais . [Internet] [Thesis]. Universidade Federal de Pernambuco; 2006. [cited 2020 Jan 24]. Available from: http://repositorio.ufpe.br/handle/123456789/9942.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

PEDROSA GAC. Utilização do dosímetro Fricke para dosimetria de máquinas teleterapêuticas, irradiadores gammacel e aparelhos de raios-X superficiais . [Thesis]. Universidade Federal de Pernambuco; 2006. Available from: http://repositorio.ufpe.br/handle/123456789/9942

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

27. Vieira, Silvio Leão. Imagens das propriedades viscoelásticas por ressonância magnética e ultrassom.

Degree: PhD, Física Aplicada à Medicina e Biologia, 2009, University of São Paulo

Em tecidos biológicos lesados, a viscoelasticidade é a propriedade física que mais se modifica em relação ao tecido normal. Palpação manual é geralmente usada para… (more)

Subjects/Keywords: Distribuição de Dose; Dose Distribution; Dosimeter Gel; Elastografia por Ressonância Magnética; Gel Dosimétrico; Magnetic Resonance Elastography; Shearwave Dispertion Ultrasound Vibrometry; Simulação de Imagem por Ultrassom.; Simulation of Ultrasound imaging.; Vibro-acustography; Vibroacustografia; Vibrometria por Força de Radiação Ultrassônica; Viscoelasticidade; Viscoelasticity

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Vieira, S. L. (2009). Imagens das propriedades viscoelásticas por ressonância magnética e ultrassom. (Doctoral Dissertation). University of São Paulo. Retrieved from http://www.teses.usp.br/teses/disponiveis/59/59135/tde-22042010-093544/ ;

Chicago Manual of Style (16th Edition):

Vieira, Silvio Leão. “Imagens das propriedades viscoelásticas por ressonância magnética e ultrassom.” 2009. Doctoral Dissertation, University of São Paulo. Accessed January 24, 2020. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-22042010-093544/ ;.

MLA Handbook (7th Edition):

Vieira, Silvio Leão. “Imagens das propriedades viscoelásticas por ressonância magnética e ultrassom.” 2009. Web. 24 Jan 2020.

Vancouver:

Vieira SL. Imagens das propriedades viscoelásticas por ressonância magnética e ultrassom. [Internet] [Doctoral dissertation]. University of São Paulo; 2009. [cited 2020 Jan 24]. Available from: http://www.teses.usp.br/teses/disponiveis/59/59135/tde-22042010-093544/ ;.

Council of Science Editors:

Vieira SL. Imagens das propriedades viscoelásticas por ressonância magnética e ultrassom. [Doctoral Dissertation]. University of São Paulo; 2009. Available from: http://www.teses.usp.br/teses/disponiveis/59/59135/tde-22042010-093544/ ;

28. Pereira, Joana Sofia Nogueira Caseiro. PPO Reaction Scale-up.

Degree: 2008, Instituto Politécnico do Porto

O óxido de polifenileno com a marca comercial PPO® é uma das resinas principais produzidas na SABIC IP e o ingrediente principal do plástico de… (more)

Subjects/Keywords: Scale-up; PPO; 2,6-xylenol; IV drop

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Pereira, J. S. N. C. (2008). PPO Reaction Scale-up. (Thesis). Instituto Politécnico do Porto. Retrieved from http://www.rcaap.pt/detail.jsp?id=oai:recipp.ipp.pt:10400.22/2535

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Pereira, Joana Sofia Nogueira Caseiro. “PPO Reaction Scale-up.” 2008. Thesis, Instituto Politécnico do Porto. Accessed January 24, 2020. http://www.rcaap.pt/detail.jsp?id=oai:recipp.ipp.pt:10400.22/2535.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Pereira, Joana Sofia Nogueira Caseiro. “PPO Reaction Scale-up.” 2008. Web. 24 Jan 2020.

Vancouver:

Pereira JSNC. PPO Reaction Scale-up. [Internet] [Thesis]. Instituto Politécnico do Porto; 2008. [cited 2020 Jan 24]. Available from: http://www.rcaap.pt/detail.jsp?id=oai:recipp.ipp.pt:10400.22/2535.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Pereira JSNC. PPO Reaction Scale-up. [Thesis]. Instituto Politécnico do Porto; 2008. Available from: http://www.rcaap.pt/detail.jsp?id=oai:recipp.ipp.pt:10400.22/2535

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Texas A&M University

29. Hernandez, Pete Jevon. Response comparison of an optically stimulated luminescent dosimeter, a direct-ion storage dosimeter, and a thermoluminescence dosimeter.

Degree: 2009, Texas A&M University

 This study was undertaken to compare the response of three dosimeters to different environments. Comanche Peak Nuclear Power Plant wants to replace the current badge… (more)

Subjects/Keywords: dosimeter; OSL; TLD; DIS

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Hernandez, P. J. (2009). Response comparison of an optically stimulated luminescent dosimeter, a direct-ion storage dosimeter, and a thermoluminescence dosimeter. (Thesis). Texas A&M University. Retrieved from http://hdl.handle.net/1969.1/ETD-TAMU-2979

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Hernandez, Pete Jevon. “Response comparison of an optically stimulated luminescent dosimeter, a direct-ion storage dosimeter, and a thermoluminescence dosimeter.” 2009. Thesis, Texas A&M University. Accessed January 24, 2020. http://hdl.handle.net/1969.1/ETD-TAMU-2979.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Hernandez, Pete Jevon. “Response comparison of an optically stimulated luminescent dosimeter, a direct-ion storage dosimeter, and a thermoluminescence dosimeter.” 2009. Web. 24 Jan 2020.

Vancouver:

Hernandez PJ. Response comparison of an optically stimulated luminescent dosimeter, a direct-ion storage dosimeter, and a thermoluminescence dosimeter. [Internet] [Thesis]. Texas A&M University; 2009. [cited 2020 Jan 24]. Available from: http://hdl.handle.net/1969.1/ETD-TAMU-2979.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Hernandez PJ. Response comparison of an optically stimulated luminescent dosimeter, a direct-ion storage dosimeter, and a thermoluminescence dosimeter. [Thesis]. Texas A&M University; 2009. Available from: http://hdl.handle.net/1969.1/ETD-TAMU-2979

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Universidade Nova

30. Bação, Milene Cristina dos Santos. Avaliação de um biodosímetro de radiação ionizante - Comparação Dosimétrica.

Degree: 2011, Universidade Nova

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade de Nova de Lisboa para complementar os requerimentos para a obtenção do grau de Mestre em Engenharia Biomédica Advisors/Committee Members: Verde, Sandra, Cruz, João.

Subjects/Keywords: Inactivação bacteriana; Biodosímetro; Fricke; Radiação gama; PENELOPE

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Bação, M. C. d. S. (2011). Avaliação de um biodosímetro de radiação ionizante - Comparação Dosimétrica. (Thesis). Universidade Nova. Retrieved from http://www.rcaap.pt/detail.jsp?id=oai:run.unl.pt:10362/7019

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Bação, Milene Cristina dos Santos. “Avaliação de um biodosímetro de radiação ionizante - Comparação Dosimétrica.” 2011. Thesis, Universidade Nova. Accessed January 24, 2020. http://www.rcaap.pt/detail.jsp?id=oai:run.unl.pt:10362/7019.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Bação, Milene Cristina dos Santos. “Avaliação de um biodosímetro de radiação ionizante - Comparação Dosimétrica.” 2011. Web. 24 Jan 2020.

Vancouver:

Bação MCdS. Avaliação de um biodosímetro de radiação ionizante - Comparação Dosimétrica. [Internet] [Thesis]. Universidade Nova; 2011. [cited 2020 Jan 24]. Available from: http://www.rcaap.pt/detail.jsp?id=oai:run.unl.pt:10362/7019.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Bação MCdS. Avaliação de um biodosímetro de radiação ionizante - Comparação Dosimétrica. [Thesis]. Universidade Nova; 2011. Available from: http://www.rcaap.pt/detail.jsp?id=oai:run.unl.pt:10362/7019

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

[1] [2] [3] [4] [5] … [80]

.