Advanced search options

Advanced Search Options 🞨

Browse by author name (“Author name starts with…”).

Find ETDs with:

in
/  
in
/  
in
/  
in

Written in Published in Earliest date Latest date

Sorted by

Results per page:

Sorted by: relevance · author · university · dateNew search

You searched for subject:(CMUT Capacitive micromachined ultrasonic transducers). Showing records 1 – 30 of 2470 total matches.

[1] [2] [3] [4] [5] … [83]

Search Limiters

Last 2 Years | English Only

Degrees

Levels

Languages

Country

▼ Search Limiters


Indian Institute of Science

1. Ahmad, Babar. Design and Development of Capacitive Micromachined Ultrasonic Transducers.

Degree: PhD, Faculty of Engineering, 2018, Indian Institute of Science

 This thesis presents the design and analysis for development of a Capacitive Micromachined Ultrasonic Transducer (CMUT), a novel sensor and actuator, aimed at replacing the… (more)

Subjects/Keywords: Ultrasonic Transducers; Electromechanical Devices; Capacitive Micromachined Ultrasonic Transducer (CMUT); Ultrasonic Imaging; Squeeze-Film Forces; Capacitive Micromachined Ultrasonic Transducers (CMUTs); Piezoelectric Transducer; Squeeze Film Forces; Ultrasound Transducers; Mechanical Engineering

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Ahmad, B. (2018). Design and Development of Capacitive Micromachined Ultrasonic Transducers. (Doctoral Dissertation). Indian Institute of Science. Retrieved from http://etd.iisc.ac.in/handle/2005/3164

Chicago Manual of Style (16th Edition):

Ahmad, Babar. “Design and Development of Capacitive Micromachined Ultrasonic Transducers.” 2018. Doctoral Dissertation, Indian Institute of Science. Accessed March 03, 2021. http://etd.iisc.ac.in/handle/2005/3164.

MLA Handbook (7th Edition):

Ahmad, Babar. “Design and Development of Capacitive Micromachined Ultrasonic Transducers.” 2018. Web. 03 Mar 2021.

Vancouver:

Ahmad B. Design and Development of Capacitive Micromachined Ultrasonic Transducers. [Internet] [Doctoral dissertation]. Indian Institute of Science; 2018. [cited 2021 Mar 03]. Available from: http://etd.iisc.ac.in/handle/2005/3164.

Council of Science Editors:

Ahmad B. Design and Development of Capacitive Micromachined Ultrasonic Transducers. [Doctoral Dissertation]. Indian Institute of Science; 2018. Available from: http://etd.iisc.ac.in/handle/2005/3164

2. Vallet, Maëva. Développement d’un système d’imagerie photoacoustique : Validation sur fantômes et application à l’athérosclérose : Development of a photoacoustic imaging system : Phantom validation and application to atherosclerosis.

Degree: Docteur es, Physique, 2015, INSA Lyon

L’imagerie photoacoustique est une nouvelle modalité couplant imagerie optique et échographie. Non invasive, elle permet d’imager des absorbeurs optiques à quelques centimètres de profondeur et… (more)

Subjects/Keywords: Imagerie médicale; Imagerie photoacoustique; Imagerie optique; Echographie; CMUT - Capacitive micromachined ultrasonic transducers; Athérosclérose; Photoacoustic imaging; CMUT - Capacitive micromachined ultrasonic transducers; Atherosclerosis; 616.075 450 72

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Vallet, M. (2015). Développement d’un système d’imagerie photoacoustique : Validation sur fantômes et application à l’athérosclérose : Development of a photoacoustic imaging system : Phantom validation and application to atherosclerosis. (Doctoral Dissertation). INSA Lyon. Retrieved from http://www.theses.fr/2015ISAL0086

Chicago Manual of Style (16th Edition):

Vallet, Maëva. “Développement d’un système d’imagerie photoacoustique : Validation sur fantômes et application à l’athérosclérose : Development of a photoacoustic imaging system : Phantom validation and application to atherosclerosis.” 2015. Doctoral Dissertation, INSA Lyon. Accessed March 03, 2021. http://www.theses.fr/2015ISAL0086.

MLA Handbook (7th Edition):

Vallet, Maëva. “Développement d’un système d’imagerie photoacoustique : Validation sur fantômes et application à l’athérosclérose : Development of a photoacoustic imaging system : Phantom validation and application to atherosclerosis.” 2015. Web. 03 Mar 2021.

Vancouver:

Vallet M. Développement d’un système d’imagerie photoacoustique : Validation sur fantômes et application à l’athérosclérose : Development of a photoacoustic imaging system : Phantom validation and application to atherosclerosis. [Internet] [Doctoral dissertation]. INSA Lyon; 2015. [cited 2021 Mar 03]. Available from: http://www.theses.fr/2015ISAL0086.

Council of Science Editors:

Vallet M. Développement d’un système d’imagerie photoacoustique : Validation sur fantômes et application à l’athérosclérose : Development of a photoacoustic imaging system : Phantom validation and application to atherosclerosis. [Doctoral Dissertation]. INSA Lyon; 2015. Available from: http://www.theses.fr/2015ISAL0086


University of Waterloo

3. Cui, Yaning. A Feasibility Study of Micromachined Ultrasonic Transducers Functionalized for Ethanol Dectection.

Degree: 2017, University of Waterloo

 The chemical sensing system plays an important role in medical and environmental monitoring. Gases exhaled by humans include nitrogen, oxygen, water vapor, carbon dioxide and… (more)

Subjects/Keywords: Micromachined Ultrasonic Transducers; Capacitive Micromachined Ultrasonic Transducers; mass-loading effect; Piezoelectric Micromachined Ultrasonic Transducers

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Cui, Y. (2017). A Feasibility Study of Micromachined Ultrasonic Transducers Functionalized for Ethanol Dectection. (Thesis). University of Waterloo. Retrieved from http://hdl.handle.net/10012/12105

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Cui, Yaning. “A Feasibility Study of Micromachined Ultrasonic Transducers Functionalized for Ethanol Dectection.” 2017. Thesis, University of Waterloo. Accessed March 03, 2021. http://hdl.handle.net/10012/12105.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Cui, Yaning. “A Feasibility Study of Micromachined Ultrasonic Transducers Functionalized for Ethanol Dectection.” 2017. Web. 03 Mar 2021.

Vancouver:

Cui Y. A Feasibility Study of Micromachined Ultrasonic Transducers Functionalized for Ethanol Dectection. [Internet] [Thesis]. University of Waterloo; 2017. [cited 2021 Mar 03]. Available from: http://hdl.handle.net/10012/12105.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Cui Y. A Feasibility Study of Micromachined Ultrasonic Transducers Functionalized for Ethanol Dectection. [Thesis]. University of Waterloo; 2017. Available from: http://hdl.handle.net/10012/12105

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Manitoba

4. Islam, Md. Iftekharul. Characterization of multiple moving membrane capacitive micromachined ultrasonic transducer.

Degree: Electrical and Computer Engineering, 2019, University of Manitoba

 A newly developed multiple moving membrane capacitive micromachined ultrasonic transducer (M3-CMUT) is fabricated and characterized in this thesis. Unlike the single vibrating membrane in the… (more)

Subjects/Keywords: Microelectromechanical System (MEMS); Capacitive Micromachined Ultrasonic Transducer (CMUT); Multiple Moving Membrane Capacitive Micromachined Ultrasonic Transducer (M3-CMUT)

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Islam, M. I. (2019). Characterization of multiple moving membrane capacitive micromachined ultrasonic transducer. (Masters Thesis). University of Manitoba. Retrieved from http://hdl.handle.net/1993/34075

Chicago Manual of Style (16th Edition):

Islam, Md Iftekharul. “Characterization of multiple moving membrane capacitive micromachined ultrasonic transducer.” 2019. Masters Thesis, University of Manitoba. Accessed March 03, 2021. http://hdl.handle.net/1993/34075.

MLA Handbook (7th Edition):

Islam, Md Iftekharul. “Characterization of multiple moving membrane capacitive micromachined ultrasonic transducer.” 2019. Web. 03 Mar 2021.

Vancouver:

Islam MI. Characterization of multiple moving membrane capacitive micromachined ultrasonic transducer. [Internet] [Masters thesis]. University of Manitoba; 2019. [cited 2021 Mar 03]. Available from: http://hdl.handle.net/1993/34075.

Council of Science Editors:

Islam MI. Characterization of multiple moving membrane capacitive micromachined ultrasonic transducer. [Masters Thesis]. University of Manitoba; 2019. Available from: http://hdl.handle.net/1993/34075


Georgia Tech

5. Lim, Jaemyung. Reduced-wire readout systems-on-chip for high-frequency intravascular ultrasound imaging.

Degree: PhD, Electrical and Computer Engineering, 2017, Georgia Tech

 The objective of the proposed research is to minimize and integrate intravascular ultrasound imaging (IVUS) system on a guidewire and to develop wireless data communication… (more)

Subjects/Keywords: IVUS; Ultrasound imaging; Intravascular; Capacitive micromachined ultrasonic transducer; CMUT

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Lim, J. (2017). Reduced-wire readout systems-on-chip for high-frequency intravascular ultrasound imaging. (Doctoral Dissertation). Georgia Tech. Retrieved from http://hdl.handle.net/1853/59800

Chicago Manual of Style (16th Edition):

Lim, Jaemyung. “Reduced-wire readout systems-on-chip for high-frequency intravascular ultrasound imaging.” 2017. Doctoral Dissertation, Georgia Tech. Accessed March 03, 2021. http://hdl.handle.net/1853/59800.

MLA Handbook (7th Edition):

Lim, Jaemyung. “Reduced-wire readout systems-on-chip for high-frequency intravascular ultrasound imaging.” 2017. Web. 03 Mar 2021.

Vancouver:

Lim J. Reduced-wire readout systems-on-chip for high-frequency intravascular ultrasound imaging. [Internet] [Doctoral dissertation]. Georgia Tech; 2017. [cited 2021 Mar 03]. Available from: http://hdl.handle.net/1853/59800.

Council of Science Editors:

Lim J. Reduced-wire readout systems-on-chip for high-frequency intravascular ultrasound imaging. [Doctoral Dissertation]. Georgia Tech; 2017. Available from: http://hdl.handle.net/1853/59800


University of Waterloo

6. Li, Zhenhao. Fabrication of Capacitive Micromachined Ultrasonic Transducers based on Adhesive Wafer Bonding.

Degree: 2017, University of Waterloo

Capacitive micromachined ultrasonic transducers (CMUTs) can be used for medical imaging, non-destructive testing or medical treatment applications. It can also be used as gravimetric sensors… (more)

Subjects/Keywords: Capacitive Micromachined Ultrasonic Transducers; Benzocyclobutene; Photosensitive Adhesive; Adhesive Wafer Bonding

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Li, Z. (2017). Fabrication of Capacitive Micromachined Ultrasonic Transducers based on Adhesive Wafer Bonding. (Thesis). University of Waterloo. Retrieved from http://hdl.handle.net/10012/11167

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Li, Zhenhao. “Fabrication of Capacitive Micromachined Ultrasonic Transducers based on Adhesive Wafer Bonding.” 2017. Thesis, University of Waterloo. Accessed March 03, 2021. http://hdl.handle.net/10012/11167.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Li, Zhenhao. “Fabrication of Capacitive Micromachined Ultrasonic Transducers based on Adhesive Wafer Bonding.” 2017. Web. 03 Mar 2021.

Vancouver:

Li Z. Fabrication of Capacitive Micromachined Ultrasonic Transducers based on Adhesive Wafer Bonding. [Internet] [Thesis]. University of Waterloo; 2017. [cited 2021 Mar 03]. Available from: http://hdl.handle.net/10012/11167.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Li Z. Fabrication of Capacitive Micromachined Ultrasonic Transducers based on Adhesive Wafer Bonding. [Thesis]. University of Waterloo; 2017. Available from: http://hdl.handle.net/10012/11167

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Texas State University – San Marcos

7. Nguyen, Duy. Analytical Modeling and Simulation of Capacitive Micromachined Ultrasonic Transducer.

Degree: MS, Engineering, 2020, Texas State University – San Marcos

 Ultrasound technology has been studied, developed and widely used in medical imaging. Ultrasonic imaging was invented to substitute the high cost ionizing radiation in magnetic… (more)

Subjects/Keywords: Capacitive Micromachined Ultrasonic Transducer; Medical imaging; Ultrasonic transducers; Ultrasonic imaging; Nanostructured materials

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Nguyen, D. (2020). Analytical Modeling and Simulation of Capacitive Micromachined Ultrasonic Transducer. (Masters Thesis). Texas State University – San Marcos. Retrieved from https://digital.library.txstate.edu/handle/10877/9864

Chicago Manual of Style (16th Edition):

Nguyen, Duy. “Analytical Modeling and Simulation of Capacitive Micromachined Ultrasonic Transducer.” 2020. Masters Thesis, Texas State University – San Marcos. Accessed March 03, 2021. https://digital.library.txstate.edu/handle/10877/9864.

MLA Handbook (7th Edition):

Nguyen, Duy. “Analytical Modeling and Simulation of Capacitive Micromachined Ultrasonic Transducer.” 2020. Web. 03 Mar 2021.

Vancouver:

Nguyen D. Analytical Modeling and Simulation of Capacitive Micromachined Ultrasonic Transducer. [Internet] [Masters thesis]. Texas State University – San Marcos; 2020. [cited 2021 Mar 03]. Available from: https://digital.library.txstate.edu/handle/10877/9864.

Council of Science Editors:

Nguyen D. Analytical Modeling and Simulation of Capacitive Micromachined Ultrasonic Transducer. [Masters Thesis]. Texas State University – San Marcos; 2020. Available from: https://digital.library.txstate.edu/handle/10877/9864


University of Windsor

8. Nazemi, Haleh. A Miniaturized Chemical Vapor Detector Using MEMS Flexible Platform.

Degree: MA, Electrical and Computer Engineering, 2019, University of Windsor

 According to the Canadian Cancer Society, lung cancer is the one of the leading causes of cancer death. It has been shown that cancer survival… (more)

Subjects/Keywords: Analytical Modeling; Bi-Layer CMUT; Capacitive Micromachined Ultrasonic Transducer; MEMS; Microelectromechanical Systems; VOC Sensor

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Nazemi, H. (2019). A Miniaturized Chemical Vapor Detector Using MEMS Flexible Platform. (Masters Thesis). University of Windsor. Retrieved from https://scholar.uwindsor.ca/etd/8174

Chicago Manual of Style (16th Edition):

Nazemi, Haleh. “A Miniaturized Chemical Vapor Detector Using MEMS Flexible Platform.” 2019. Masters Thesis, University of Windsor. Accessed March 03, 2021. https://scholar.uwindsor.ca/etd/8174.

MLA Handbook (7th Edition):

Nazemi, Haleh. “A Miniaturized Chemical Vapor Detector Using MEMS Flexible Platform.” 2019. Web. 03 Mar 2021.

Vancouver:

Nazemi H. A Miniaturized Chemical Vapor Detector Using MEMS Flexible Platform. [Internet] [Masters thesis]. University of Windsor; 2019. [cited 2021 Mar 03]. Available from: https://scholar.uwindsor.ca/etd/8174.

Council of Science Editors:

Nazemi H. A Miniaturized Chemical Vapor Detector Using MEMS Flexible Platform. [Masters Thesis]. University of Windsor; 2019. Available from: https://scholar.uwindsor.ca/etd/8174


Georgia Tech

9. Zahorian, Jaime S. Fabrication technology and design for CMUTS on CMOS for IVUS catheters.

Degree: PhD, Electrical and Computer Engineering, 2013, Georgia Tech

 The objective of this research is to develop novel capacitive micromachined ultrasonic transducer (CMUT) arrays for intravascular ultrasonic (IVUS) imaging along with the fabrication processes… (more)

Subjects/Keywords: Intravascular ultrasonic (IVUS); Capacitive micromachined ultrasonic transducer (CMUT); Complementary metal oxide semiconductor (CMOS); Metal oxide semiconductors, Complementary; Ultrasonic transducer; Diagnostic ultrasonic imaging; Intravascular ultrasonography

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Zahorian, J. S. (2013). Fabrication technology and design for CMUTS on CMOS for IVUS catheters. (Doctoral Dissertation). Georgia Tech. Retrieved from http://hdl.handle.net/1853/51730

Chicago Manual of Style (16th Edition):

Zahorian, Jaime S. “Fabrication technology and design for CMUTS on CMOS for IVUS catheters.” 2013. Doctoral Dissertation, Georgia Tech. Accessed March 03, 2021. http://hdl.handle.net/1853/51730.

MLA Handbook (7th Edition):

Zahorian, Jaime S. “Fabrication technology and design for CMUTS on CMOS for IVUS catheters.” 2013. Web. 03 Mar 2021.

Vancouver:

Zahorian JS. Fabrication technology and design for CMUTS on CMOS for IVUS catheters. [Internet] [Doctoral dissertation]. Georgia Tech; 2013. [cited 2021 Mar 03]. Available from: http://hdl.handle.net/1853/51730.

Council of Science Editors:

Zahorian JS. Fabrication technology and design for CMUTS on CMOS for IVUS catheters. [Doctoral Dissertation]. Georgia Tech; 2013. Available from: http://hdl.handle.net/1853/51730


Delft University of Technology

10. Westhoek, Youri (author). Ultrasound Energy Transfer using Charged CMUTs.

Degree: 2020, Delft University of Technology

 Implantable medical devices (IMDs) such as cardiac pacemakers, cochlear implants, and neurostimulators improve millions of people’s lives every day. Over the years, IMDs have significantly… (more)

Subjects/Keywords: Ultrasound Energy Transfer; Ultrasound Power Transfer; CMUT; Ultrasound Transducer; Wireless Energy Transfer; Wireless Power Transfer; Medical Devices; Ultrasound Imaging; Ultrasound Probe; Ultrasound; Capacitive Micromachined Ultrasound Transducers; Implantable Medical Devices (IMDs)

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Westhoek, Y. (. (2020). Ultrasound Energy Transfer using Charged CMUTs. (Masters Thesis). Delft University of Technology. Retrieved from http://resolver.tudelft.nl/uuid:74a07486-73c2-4457-8261-7161acb46c60

Chicago Manual of Style (16th Edition):

Westhoek, Youri (author). “Ultrasound Energy Transfer using Charged CMUTs.” 2020. Masters Thesis, Delft University of Technology. Accessed March 03, 2021. http://resolver.tudelft.nl/uuid:74a07486-73c2-4457-8261-7161acb46c60.

MLA Handbook (7th Edition):

Westhoek, Youri (author). “Ultrasound Energy Transfer using Charged CMUTs.” 2020. Web. 03 Mar 2021.

Vancouver:

Westhoek Y(. Ultrasound Energy Transfer using Charged CMUTs. [Internet] [Masters thesis]. Delft University of Technology; 2020. [cited 2021 Mar 03]. Available from: http://resolver.tudelft.nl/uuid:74a07486-73c2-4457-8261-7161acb46c60.

Council of Science Editors:

Westhoek Y(. Ultrasound Energy Transfer using Charged CMUTs. [Masters Thesis]. Delft University of Technology; 2020. Available from: http://resolver.tudelft.nl/uuid:74a07486-73c2-4457-8261-7161acb46c60


Georgia Tech

11. Shieh, Bernard D. Fluid-structure simulation of large micromachined ultrasonic transducer arrays.

Degree: PhD, Mechanical Engineering, 2017, Georgia Tech

 Acoustic transducer arrays composed of a large number of flexural membranes are found in a diversity of applications such as underwater acoustics, medical therapeutics, and… (more)

Subjects/Keywords: Micromachined Ultrasonic Transducers; Fast Multipole Algorithm

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Shieh, B. D. (2017). Fluid-structure simulation of large micromachined ultrasonic transducer arrays. (Doctoral Dissertation). Georgia Tech. Retrieved from http://hdl.handle.net/1853/59186

Chicago Manual of Style (16th Edition):

Shieh, Bernard D. “Fluid-structure simulation of large micromachined ultrasonic transducer arrays.” 2017. Doctoral Dissertation, Georgia Tech. Accessed March 03, 2021. http://hdl.handle.net/1853/59186.

MLA Handbook (7th Edition):

Shieh, Bernard D. “Fluid-structure simulation of large micromachined ultrasonic transducer arrays.” 2017. Web. 03 Mar 2021.

Vancouver:

Shieh BD. Fluid-structure simulation of large micromachined ultrasonic transducer arrays. [Internet] [Doctoral dissertation]. Georgia Tech; 2017. [cited 2021 Mar 03]. Available from: http://hdl.handle.net/1853/59186.

Council of Science Editors:

Shieh BD. Fluid-structure simulation of large micromachined ultrasonic transducer arrays. [Doctoral Dissertation]. Georgia Tech; 2017. Available from: http://hdl.handle.net/1853/59186


University of Texas – Austin

12. Hord, Samuel Kay. A novel fabrication process for CMUTs in air.

Degree: MSin Engineering, Mechanical Engineering, 2018, University of Texas – Austin

 A novel fabrication method for producing capacitive micromachined ultrasonic transducers (CMUTs) is presented. The process uses conductive silicon on insulator (SOI) substrates to produce an… (more)

Subjects/Keywords: CMUT; Ultrasonic transducers; Transducers; Semiconductor fabrication; Acoustics; Acoustical MEMS; MEMS

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Hord, S. K. (2018). A novel fabrication process for CMUTs in air. (Masters Thesis). University of Texas – Austin. Retrieved from http://hdl.handle.net/2152/69092

Chicago Manual of Style (16th Edition):

Hord, Samuel Kay. “A novel fabrication process for CMUTs in air.” 2018. Masters Thesis, University of Texas – Austin. Accessed March 03, 2021. http://hdl.handle.net/2152/69092.

MLA Handbook (7th Edition):

Hord, Samuel Kay. “A novel fabrication process for CMUTs in air.” 2018. Web. 03 Mar 2021.

Vancouver:

Hord SK. A novel fabrication process for CMUTs in air. [Internet] [Masters thesis]. University of Texas – Austin; 2018. [cited 2021 Mar 03]. Available from: http://hdl.handle.net/2152/69092.

Council of Science Editors:

Hord SK. A novel fabrication process for CMUTs in air. [Masters Thesis]. University of Texas – Austin; 2018. Available from: http://hdl.handle.net/2152/69092

13. Na, Shuai. Air-coupled Capacitive Micromachined Ultrasonic Transducers based on Annular Cell Geometry.

Degree: 2017, University of Waterloo

 Air-coupled ultrasound is gaining increasing industry momentum due to the demands and development of non-destructive evaluation (NDE) of aerospace composite materials. Currently, the micromachining technology… (more)

Subjects/Keywords: Acoustics; Capacitive Micromachined Ultrasonic Transducers; Air-coupled ultrasound; Annular Geometry

…11 2.4 Capacitive Micromachined Ultrasonic Transducers… …Using micro-fabrication technology, transducers called capacitive micromachined ultrasonic… …2.4 Capacitive Micromachined Ultrasonic Transducers Capacitive micromachined ultrasonic… …background of ultrasound, basics of piezoelectric ultrasonic transducers, transducer arrays, CMUT… …further promote the development of air-coupled ultrasonic transducers. In general, designing an… 

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Na, S. (2017). Air-coupled Capacitive Micromachined Ultrasonic Transducers based on Annular Cell Geometry. (Thesis). University of Waterloo. Retrieved from http://hdl.handle.net/10012/12142

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Na, Shuai. “Air-coupled Capacitive Micromachined Ultrasonic Transducers based on Annular Cell Geometry.” 2017. Thesis, University of Waterloo. Accessed March 03, 2021. http://hdl.handle.net/10012/12142.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Na, Shuai. “Air-coupled Capacitive Micromachined Ultrasonic Transducers based on Annular Cell Geometry.” 2017. Web. 03 Mar 2021.

Vancouver:

Na S. Air-coupled Capacitive Micromachined Ultrasonic Transducers based on Annular Cell Geometry. [Internet] [Thesis]. University of Waterloo; 2017. [cited 2021 Mar 03]. Available from: http://hdl.handle.net/10012/12142.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Na S. Air-coupled Capacitive Micromachined Ultrasonic Transducers based on Annular Cell Geometry. [Thesis]. University of Waterloo; 2017. Available from: http://hdl.handle.net/10012/12142

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Aristotle University Of Thessaloniki (AUTH); Αριστοτέλειο Πανεπιστήμιο Θεσσαλονίκης (ΑΠΘ)

14. Chouvardas, Vasilios. Σχεδιασμός και προσομοίωση δομικών μονάδων απτικών οθονών.

Degree: 2014, Aristotle University Of Thessaloniki (AUTH); Αριστοτέλειο Πανεπιστήμιο Θεσσαλονίκης (ΑΠΘ)

The sense of touch creates tactile feelings in the brain, using the sensors and the nerves of the skin that can be stimulated by mechanical,… (more)

Subjects/Keywords: Απτική επικονωνία; Απτικές Οθόνες; Μίκρο ηλεκτρομηχανολογικά συστήματα; Ανάλυση πεπερασμένων στοιχείων; Μικροηλεκτρονική; Φασικές συστοιχίες; Ισοδύναμο ηλεκτρικό κύκλωμα; Tactile Displays; Capacitive Micromachined Ultrasonic Transducers; Finite element analysis; Phased Arrays; Equivalent circuit

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Chouvardas, V. (2014). Σχεδιασμός και προσομοίωση δομικών μονάδων απτικών οθονών. (Thesis). Aristotle University Of Thessaloniki (AUTH); Αριστοτέλειο Πανεπιστήμιο Θεσσαλονίκης (ΑΠΘ). Retrieved from http://hdl.handle.net/10442/hedi/34635

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Chouvardas, Vasilios. “Σχεδιασμός και προσομοίωση δομικών μονάδων απτικών οθονών.” 2014. Thesis, Aristotle University Of Thessaloniki (AUTH); Αριστοτέλειο Πανεπιστήμιο Θεσσαλονίκης (ΑΠΘ). Accessed March 03, 2021. http://hdl.handle.net/10442/hedi/34635.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Chouvardas, Vasilios. “Σχεδιασμός και προσομοίωση δομικών μονάδων απτικών οθονών.” 2014. Web. 03 Mar 2021.

Vancouver:

Chouvardas V. Σχεδιασμός και προσομοίωση δομικών μονάδων απτικών οθονών. [Internet] [Thesis]. Aristotle University Of Thessaloniki (AUTH); Αριστοτέλειο Πανεπιστήμιο Θεσσαλονίκης (ΑΠΘ); 2014. [cited 2021 Mar 03]. Available from: http://hdl.handle.net/10442/hedi/34635.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Chouvardas V. Σχεδιασμός και προσομοίωση δομικών μονάδων απτικών οθονών. [Thesis]. Aristotle University Of Thessaloniki (AUTH); Αριστοτέλειο Πανεπιστήμιο Θεσσαλονίκης (ΑΠΘ); 2014. Available from: http://hdl.handle.net/10442/hedi/34635

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Waterloo

15. Chan, Jasmine Yi Jie. Study of Various Detection Mechanisms for Photoacoustic Imaging.

Degree: 2020, University of Waterloo

 Photoacoustic imaging (PAI) is a developing imaging technique that has been researched for several clinical applications including oncology, neurology, dermatology and ophthalmology. PAI combines the… (more)

Subjects/Keywords: capacitive micromachined ultrasound transducers; photoacoustic; photoacoustic remote sensing

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Chan, J. Y. J. (2020). Study of Various Detection Mechanisms for Photoacoustic Imaging. (Thesis). University of Waterloo. Retrieved from http://hdl.handle.net/10012/16212

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Chan, Jasmine Yi Jie. “Study of Various Detection Mechanisms for Photoacoustic Imaging.” 2020. Thesis, University of Waterloo. Accessed March 03, 2021. http://hdl.handle.net/10012/16212.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Chan, Jasmine Yi Jie. “Study of Various Detection Mechanisms for Photoacoustic Imaging.” 2020. Web. 03 Mar 2021.

Vancouver:

Chan JYJ. Study of Various Detection Mechanisms for Photoacoustic Imaging. [Internet] [Thesis]. University of Waterloo; 2020. [cited 2021 Mar 03]. Available from: http://hdl.handle.net/10012/16212.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Chan JYJ. Study of Various Detection Mechanisms for Photoacoustic Imaging. [Thesis]. University of Waterloo; 2020. Available from: http://hdl.handle.net/10012/16212

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

16. Boulmé, Audren. Conception et caractérisation de sondes cMUT large bande pour l'imagerie conventionnelle et l'évaluation du tissu osseux : Design and characterization of broadband cMUT probe for conventional imaging and assessment of bone tissue.

Degree: Docteur es, Sciences de la Vie et de la Santé, 2013, Université François-Rabelais de Tours

Les transducteurs ultrasonores capacitifs micro-usinés (cMUT : capacitive Micromachined Ultrasound Transducers) apparaissent, au vu de leur maturité croissante, comme une alternative de plus en plus… (more)

Subjects/Keywords: Transducteurs ultrasonores capacitifs micro-usinés; CMUT; Fonction de Green; Condition de périodicité; Effets de baffle; Couplage inter-éléments; Caractérisation de sonde ultrasonore; Caractérisation de l'os cortical; Mesure en transmission axiale; Capacitive Micromachined Ultrasound Transducers; CMUT; Green function; Periodic conditions; Baffle effects; Inter-elements crosstalk; Characterization of ultrasound probes; Cortical bone assessment; Axial transmission measurement

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Boulmé, A. (2013). Conception et caractérisation de sondes cMUT large bande pour l'imagerie conventionnelle et l'évaluation du tissu osseux : Design and characterization of broadband cMUT probe for conventional imaging and assessment of bone tissue. (Doctoral Dissertation). Université François-Rabelais de Tours. Retrieved from http://www.theses.fr/2013TOUR3319

Chicago Manual of Style (16th Edition):

Boulmé, Audren. “Conception et caractérisation de sondes cMUT large bande pour l'imagerie conventionnelle et l'évaluation du tissu osseux : Design and characterization of broadband cMUT probe for conventional imaging and assessment of bone tissue.” 2013. Doctoral Dissertation, Université François-Rabelais de Tours. Accessed March 03, 2021. http://www.theses.fr/2013TOUR3319.

MLA Handbook (7th Edition):

Boulmé, Audren. “Conception et caractérisation de sondes cMUT large bande pour l'imagerie conventionnelle et l'évaluation du tissu osseux : Design and characterization of broadband cMUT probe for conventional imaging and assessment of bone tissue.” 2013. Web. 03 Mar 2021.

Vancouver:

Boulmé A. Conception et caractérisation de sondes cMUT large bande pour l'imagerie conventionnelle et l'évaluation du tissu osseux : Design and characterization of broadband cMUT probe for conventional imaging and assessment of bone tissue. [Internet] [Doctoral dissertation]. Université François-Rabelais de Tours; 2013. [cited 2021 Mar 03]. Available from: http://www.theses.fr/2013TOUR3319.

Council of Science Editors:

Boulmé A. Conception et caractérisation de sondes cMUT large bande pour l'imagerie conventionnelle et l'évaluation du tissu osseux : Design and characterization of broadband cMUT probe for conventional imaging and assessment of bone tissue. [Doctoral Dissertation]. Université François-Rabelais de Tours; 2013. Available from: http://www.theses.fr/2013TOUR3319

17. Jeba, Dilruba Zaman. Capacitive Micromachined Ultrasonic Transducers: Design, Fabrication and Characterization.

Degree: Electrical and Computer Engineering, 2014, University of Manitoba

Capacitive micromachined ultrasonic transducers (CMUTs) have been developed as an alternative to piezoelectric transducers for ultrasonic imaging in non-destructive testing applications. These CMUTs offer substantial… (more)

Subjects/Keywords: CMUT; Transducers; MEMS; Ultrasonic

…principle of a capacitive micromachined ultrasonic transducer (CMUT) is described in… …the capacitive micromachined ultrasonic transducer (CMUT). The capacitive… …a CMUT: The cross sectional schematic view of a capacitive micromachined ultrasonic… …fabrication techniques. Capacitive micromachined ultrasonic transducers have overcome some of the… …dynamics of a capacitive micromachined ultrasonic transducer (CMUT) is similar to a… 

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Jeba, D. Z. (2014). Capacitive Micromachined Ultrasonic Transducers: Design, Fabrication and Characterization. (Masters Thesis). University of Manitoba. Retrieved from http://hdl.handle.net/1993/23928

Chicago Manual of Style (16th Edition):

Jeba, Dilruba Zaman. “Capacitive Micromachined Ultrasonic Transducers: Design, Fabrication and Characterization.” 2014. Masters Thesis, University of Manitoba. Accessed March 03, 2021. http://hdl.handle.net/1993/23928.

MLA Handbook (7th Edition):

Jeba, Dilruba Zaman. “Capacitive Micromachined Ultrasonic Transducers: Design, Fabrication and Characterization.” 2014. Web. 03 Mar 2021.

Vancouver:

Jeba DZ. Capacitive Micromachined Ultrasonic Transducers: Design, Fabrication and Characterization. [Internet] [Masters thesis]. University of Manitoba; 2014. [cited 2021 Mar 03]. Available from: http://hdl.handle.net/1993/23928.

Council of Science Editors:

Jeba DZ. Capacitive Micromachined Ultrasonic Transducers: Design, Fabrication and Characterization. [Masters Thesis]. University of Manitoba; 2014. Available from: http://hdl.handle.net/1993/23928


Georgia Tech

18. Hochman, Michael. Investigation of acoustic crosstalk effects in CMUT arrays.

Degree: MS, Mechanical Engineering, 2011, Georgia Tech

Capacitive Micromachined Ultrasonic Transducers (CMUTs) have demonstrated significant potential to advance the state of medical ultrasound imaging beyond the capabilities of the currently employed piezoelectric… (more)

Subjects/Keywords: Analytical model; Acoustic crosstalk; CMUT; Ultrasonic transducers; Crosstalk; Finite element method; Computer simulation

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Hochman, M. (2011). Investigation of acoustic crosstalk effects in CMUT arrays. (Masters Thesis). Georgia Tech. Retrieved from http://hdl.handle.net/1853/42782

Chicago Manual of Style (16th Edition):

Hochman, Michael. “Investigation of acoustic crosstalk effects in CMUT arrays.” 2011. Masters Thesis, Georgia Tech. Accessed March 03, 2021. http://hdl.handle.net/1853/42782.

MLA Handbook (7th Edition):

Hochman, Michael. “Investigation of acoustic crosstalk effects in CMUT arrays.” 2011. Web. 03 Mar 2021.

Vancouver:

Hochman M. Investigation of acoustic crosstalk effects in CMUT arrays. [Internet] [Masters thesis]. Georgia Tech; 2011. [cited 2021 Mar 03]. Available from: http://hdl.handle.net/1853/42782.

Council of Science Editors:

Hochman M. Investigation of acoustic crosstalk effects in CMUT arrays. [Masters Thesis]. Georgia Tech; 2011. Available from: http://hdl.handle.net/1853/42782

19. Lascaud, Julie. Elaboration de couches minces atténuantes en silicium poreux : Application aux transducteurs ultrasonores capacitifs micro-usinés : Development of thin attenuating porous silicon layers : application to the capacitive micromachine ultrasonic.

Degree: Docteur es, Electronique, 2017, Université François-Rabelais de Tours

Les transducteurs ultrasonores capacitifs micro-usinés (CMUT) représentent aujourd’hui une réelle alternative aux technologies piézoélectriques dans le domaine de l’imagerie échographique médicale. Au cours des années,… (more)

Subjects/Keywords: Couche atténuante; Silicium poreux; Transducteurs ultrasonores; Gravure électrochimique; Caractérisations acoustiques; CMUT; Backing layer; Porous silicon; Ultrasonic transducers; Electrochemical etching; Acoustic characterizations; CMUT

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Lascaud, J. (2017). Elaboration de couches minces atténuantes en silicium poreux : Application aux transducteurs ultrasonores capacitifs micro-usinés : Development of thin attenuating porous silicon layers : application to the capacitive micromachine ultrasonic. (Doctoral Dissertation). Université François-Rabelais de Tours. Retrieved from http://www.theses.fr/2017TOUR4026

Chicago Manual of Style (16th Edition):

Lascaud, Julie. “Elaboration de couches minces atténuantes en silicium poreux : Application aux transducteurs ultrasonores capacitifs micro-usinés : Development of thin attenuating porous silicon layers : application to the capacitive micromachine ultrasonic.” 2017. Doctoral Dissertation, Université François-Rabelais de Tours. Accessed March 03, 2021. http://www.theses.fr/2017TOUR4026.

MLA Handbook (7th Edition):

Lascaud, Julie. “Elaboration de couches minces atténuantes en silicium poreux : Application aux transducteurs ultrasonores capacitifs micro-usinés : Development of thin attenuating porous silicon layers : application to the capacitive micromachine ultrasonic.” 2017. Web. 03 Mar 2021.

Vancouver:

Lascaud J. Elaboration de couches minces atténuantes en silicium poreux : Application aux transducteurs ultrasonores capacitifs micro-usinés : Development of thin attenuating porous silicon layers : application to the capacitive micromachine ultrasonic. [Internet] [Doctoral dissertation]. Université François-Rabelais de Tours; 2017. [cited 2021 Mar 03]. Available from: http://www.theses.fr/2017TOUR4026.

Council of Science Editors:

Lascaud J. Elaboration de couches minces atténuantes en silicium poreux : Application aux transducteurs ultrasonores capacitifs micro-usinés : Development of thin attenuating porous silicon layers : application to the capacitive micromachine ultrasonic. [Doctoral Dissertation]. Université François-Rabelais de Tours; 2017. Available from: http://www.theses.fr/2017TOUR4026


University of California – Berkeley

20. Akhbari, Sina. Curved and bimorph piezoelectric micromachined ultrasonic transducers (PMUT).

Degree: Mechanical Engineering, 2016, University of California – Berkeley

Ultrasonic transducers have been realized as nondestructive tools for a variety of applications, such as medical imaging, diagnosis, therapy, nondestructive testing, range finding, and gesture… (more)

Subjects/Keywords: Mechanical engineering; Acoustics; Electrical engineering; Bimorph PMUT; Curved PMUT; Medical Devices; MEMS; Piezoelectric Micromachined Ultrasonic Transducers (PMUT); Ultrasonics

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Akhbari, S. (2016). Curved and bimorph piezoelectric micromachined ultrasonic transducers (PMUT). (Thesis). University of California – Berkeley. Retrieved from http://www.escholarship.org/uc/item/7zn4p2vt

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Akhbari, Sina. “Curved and bimorph piezoelectric micromachined ultrasonic transducers (PMUT).” 2016. Thesis, University of California – Berkeley. Accessed March 03, 2021. http://www.escholarship.org/uc/item/7zn4p2vt.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Akhbari, Sina. “Curved and bimorph piezoelectric micromachined ultrasonic transducers (PMUT).” 2016. Web. 03 Mar 2021.

Vancouver:

Akhbari S. Curved and bimorph piezoelectric micromachined ultrasonic transducers (PMUT). [Internet] [Thesis]. University of California – Berkeley; 2016. [cited 2021 Mar 03]. Available from: http://www.escholarship.org/uc/item/7zn4p2vt.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Akhbari S. Curved and bimorph piezoelectric micromachined ultrasonic transducers (PMUT). [Thesis]. University of California – Berkeley; 2016. Available from: http://www.escholarship.org/uc/item/7zn4p2vt

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

21. Gurun, Gokce. Integrated electronics design for high-frequency intravascular ultrasound imaging.

Degree: PhD, Electrical and Computer Engineering, 2011, Georgia Tech

 Close integration of front-end electronics and the transducer array within the catheter is critical for successful implementation of CMUT-based intravascular ultrasound (IVUS) imaging catheters to… (more)

Subjects/Keywords: TIA; CMUT; IVUS; CMUT electronics; CMUT-on-CMOS; Intravascular ultrasonography; Endoscopic ultrasonography; Diagnostic ultrasonic imaging; Transducers

…an IC compatible capacitive micromachined ultrasound transducer (CMUT) technology… …32 1.4.5. IVUS Probe Using Annular CMUT Arrays… …44 CHAPTER 2 INTEGRATED FRONT-END ELECTRONICS FOR CMUT INTERFACING… …53 2.3. Overview of Various Preamplifier Configurations for CMUT Sensing .............55… …67 2.3.4. Capacitive-Feedback Transimpedance Amplifier… 

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Gurun, G. (2011). Integrated electronics design for high-frequency intravascular ultrasound imaging. (Doctoral Dissertation). Georgia Tech. Retrieved from http://hdl.handle.net/1853/45860

Chicago Manual of Style (16th Edition):

Gurun, Gokce. “Integrated electronics design for high-frequency intravascular ultrasound imaging.” 2011. Doctoral Dissertation, Georgia Tech. Accessed March 03, 2021. http://hdl.handle.net/1853/45860.

MLA Handbook (7th Edition):

Gurun, Gokce. “Integrated electronics design for high-frequency intravascular ultrasound imaging.” 2011. Web. 03 Mar 2021.

Vancouver:

Gurun G. Integrated electronics design for high-frequency intravascular ultrasound imaging. [Internet] [Doctoral dissertation]. Georgia Tech; 2011. [cited 2021 Mar 03]. Available from: http://hdl.handle.net/1853/45860.

Council of Science Editors:

Gurun G. Integrated electronics design for high-frequency intravascular ultrasound imaging. [Doctoral Dissertation]. Georgia Tech; 2011. Available from: http://hdl.handle.net/1853/45860

22. Bahette, Emilie. Réalisation et caractérisation de CMUT basse température pour applications d'imagerie médicale : Realization and characterization of low temperature CMUT for medical imaging applications.

Degree: Docteur es, Electronique, 2014, Université François-Rabelais de Tours

Les cMUT sont des microsystèmes principalement utilisés pour de l’imagerie médicale. Afin de développer de nouvelles architectures de sondes, intégrer l’électronique de commande devient impératif.… (more)

Subjects/Keywords: Transducteur ultrasonore capacitif micro-usiné; "cMUT"; Application médicale; Basse température; Capacitive micro-machined ultrasonic transducer; "cMUTn"; High frequency medical imaging application; Low temperature

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Bahette, E. (2014). Réalisation et caractérisation de CMUT basse température pour applications d'imagerie médicale : Realization and characterization of low temperature CMUT for medical imaging applications. (Doctoral Dissertation). Université François-Rabelais de Tours. Retrieved from http://www.theses.fr/2014TOUR4011

Chicago Manual of Style (16th Edition):

Bahette, Emilie. “Réalisation et caractérisation de CMUT basse température pour applications d'imagerie médicale : Realization and characterization of low temperature CMUT for medical imaging applications.” 2014. Doctoral Dissertation, Université François-Rabelais de Tours. Accessed March 03, 2021. http://www.theses.fr/2014TOUR4011.

MLA Handbook (7th Edition):

Bahette, Emilie. “Réalisation et caractérisation de CMUT basse température pour applications d'imagerie médicale : Realization and characterization of low temperature CMUT for medical imaging applications.” 2014. Web. 03 Mar 2021.

Vancouver:

Bahette E. Réalisation et caractérisation de CMUT basse température pour applications d'imagerie médicale : Realization and characterization of low temperature CMUT for medical imaging applications. [Internet] [Doctoral dissertation]. Université François-Rabelais de Tours; 2014. [cited 2021 Mar 03]. Available from: http://www.theses.fr/2014TOUR4011.

Council of Science Editors:

Bahette E. Réalisation et caractérisation de CMUT basse température pour applications d'imagerie médicale : Realization and characterization of low temperature CMUT for medical imaging applications. [Doctoral Dissertation]. Université François-Rabelais de Tours; 2014. Available from: http://www.theses.fr/2014TOUR4011


Indian Institute of Science

23. Dangi, Ajay. Piezoelectric Micromachined Ultrasound Transducers : From Design to Applications.

Degree: PhD, Faculty of Engineering, 2018, Indian Institute of Science

Ultrasonic sensors are well known for various applications such as NDT, ultrasound imaging, and proximity sensing. Conventional ultrasound transducers are bulky, work at notoriously high… (more)

Subjects/Keywords: Ultrasound Transducers PMUT; PMUT Fabrication; MEMS; FEM Validation; Piezoelectric Characteristics; System Level Modelling; Piezoelectric Micromachined Ultrasonic Transducer; Piezo-MEMS Devices; PMUTs; PMUT-Fluid Interactions; Mechanical Engineering

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Dangi, A. (2018). Piezoelectric Micromachined Ultrasound Transducers : From Design to Applications. (Doctoral Dissertation). Indian Institute of Science. Retrieved from http://etd.iisc.ac.in/handle/2005/3737

Chicago Manual of Style (16th Edition):

Dangi, Ajay. “Piezoelectric Micromachined Ultrasound Transducers : From Design to Applications.” 2018. Doctoral Dissertation, Indian Institute of Science. Accessed March 03, 2021. http://etd.iisc.ac.in/handle/2005/3737.

MLA Handbook (7th Edition):

Dangi, Ajay. “Piezoelectric Micromachined Ultrasound Transducers : From Design to Applications.” 2018. Web. 03 Mar 2021.

Vancouver:

Dangi A. Piezoelectric Micromachined Ultrasound Transducers : From Design to Applications. [Internet] [Doctoral dissertation]. Indian Institute of Science; 2018. [cited 2021 Mar 03]. Available from: http://etd.iisc.ac.in/handle/2005/3737.

Council of Science Editors:

Dangi A. Piezoelectric Micromachined Ultrasound Transducers : From Design to Applications. [Doctoral Dissertation]. Indian Institute of Science; 2018. Available from: http://etd.iisc.ac.in/handle/2005/3737

24. Guldiken, Rasim Oytun. Dual-electrode capacitive micromachined ultrasonic transducers for medical ultrasound applications.

Degree: PhD, Mechanical Engineering, 2008, Georgia Tech

Capacitive Micromachined Ultrasonic Transducers (CMUTs) have been introduced as a viable alternative to piezoelectric transducers in medical ultrasound imaging in the last decade. CMUTs are… (more)

Subjects/Keywords: CMUT; High bandwidth transducers; High efficieny transducers; Ultrasonics in medicine; Ultrasonic transducers; Finite element method

…1.2.2 Capacitive Micromachined Ultrasonic Transducers (CMUTs) Some of the problems… …as Capacitive Micromachined Ultrasonic Transducer (CMUT). As illustrated in… …CMUT for charging experiments ................ 154 xiii SUMMARY Capacitive Micromachined… …Ultrasonic Transducers (CMUTs) have been introduced as a viable alternative to… …capacitive actuation to generate ultrasonic waves. The main advantage of this alternative is the… 

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Guldiken, R. O. (2008). Dual-electrode capacitive micromachined ultrasonic transducers for medical ultrasound applications. (Doctoral Dissertation). Georgia Tech. Retrieved from http://hdl.handle.net/1853/31806

Chicago Manual of Style (16th Edition):

Guldiken, Rasim Oytun. “Dual-electrode capacitive micromachined ultrasonic transducers for medical ultrasound applications.” 2008. Doctoral Dissertation, Georgia Tech. Accessed March 03, 2021. http://hdl.handle.net/1853/31806.

MLA Handbook (7th Edition):

Guldiken, Rasim Oytun. “Dual-electrode capacitive micromachined ultrasonic transducers for medical ultrasound applications.” 2008. Web. 03 Mar 2021.

Vancouver:

Guldiken RO. Dual-electrode capacitive micromachined ultrasonic transducers for medical ultrasound applications. [Internet] [Doctoral dissertation]. Georgia Tech; 2008. [cited 2021 Mar 03]. Available from: http://hdl.handle.net/1853/31806.

Council of Science Editors:

Guldiken RO. Dual-electrode capacitive micromachined ultrasonic transducers for medical ultrasound applications. [Doctoral Dissertation]. Georgia Tech; 2008. Available from: http://hdl.handle.net/1853/31806

25. Ngo, Sophie. Dispositf acoustique pour l'isolation galvanique : le CMUT, une voie innovante : Galvanic isolation by acoustic device : the CMUT, an innovative solution.

Degree: Docteur es, Electronique, 2013, Université François-Rabelais de Tours

Les dispositifs d’isolation galvanique intégrés au sein des systèmes de commande d’interrupteurs de puissance doivent répondre à une demande accrue en performance, facilité d’intégration et… (more)

Subjects/Keywords: Isolation galvanique; Transducteur ultrasonore capacitif micro-usiné; CMUT; Ultrasons; Onde acoustique de volume; Micro-usinage de surface; Vibrométrie laser Doppler; Transformateur acoustique; Galvanic isolation; Capacitive micro-machined ultrasonic transducer; CMUT; Bulk acoustic wave; Surface micro-machining; Vibrometer laser Doppler; Power switch; Acoustic transformer

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Ngo, S. (2013). Dispositf acoustique pour l'isolation galvanique : le CMUT, une voie innovante : Galvanic isolation by acoustic device : the CMUT, an innovative solution. (Doctoral Dissertation). Université François-Rabelais de Tours. Retrieved from http://www.theses.fr/2013TOUR4027

Chicago Manual of Style (16th Edition):

Ngo, Sophie. “Dispositf acoustique pour l'isolation galvanique : le CMUT, une voie innovante : Galvanic isolation by acoustic device : the CMUT, an innovative solution.” 2013. Doctoral Dissertation, Université François-Rabelais de Tours. Accessed March 03, 2021. http://www.theses.fr/2013TOUR4027.

MLA Handbook (7th Edition):

Ngo, Sophie. “Dispositf acoustique pour l'isolation galvanique : le CMUT, une voie innovante : Galvanic isolation by acoustic device : the CMUT, an innovative solution.” 2013. Web. 03 Mar 2021.

Vancouver:

Ngo S. Dispositf acoustique pour l'isolation galvanique : le CMUT, une voie innovante : Galvanic isolation by acoustic device : the CMUT, an innovative solution. [Internet] [Doctoral dissertation]. Université François-Rabelais de Tours; 2013. [cited 2021 Mar 03]. Available from: http://www.theses.fr/2013TOUR4027.

Council of Science Editors:

Ngo S. Dispositf acoustique pour l'isolation galvanique : le CMUT, une voie innovante : Galvanic isolation by acoustic device : the CMUT, an innovative solution. [Doctoral Dissertation]. Université François-Rabelais de Tours; 2013. Available from: http://www.theses.fr/2013TOUR4027


Delft University of Technology

26. Bonse, M.H.W. Capacitive Position Transducers: Theoretical Aspects and Practical Applications.

Degree: 1995, Delft University of Technology

Subjects/Keywords: capacitive position transducers

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Bonse, M. H. W. (1995). Capacitive Position Transducers: Theoretical Aspects and Practical Applications. (Doctoral Dissertation). Delft University of Technology. Retrieved from http://resolver.tudelft.nl/uuid:f0a81df4-4e2b-42b7-8ac9-46b1c8c5111a ; urn:NBN:nl:ui:24-uuid:f0a81df4-4e2b-42b7-8ac9-46b1c8c5111a ; urn:NBN:nl:ui:24-uuid:f0a81df4-4e2b-42b7-8ac9-46b1c8c5111a ; http://resolver.tudelft.nl/uuid:f0a81df4-4e2b-42b7-8ac9-46b1c8c5111a

Chicago Manual of Style (16th Edition):

Bonse, M H W. “Capacitive Position Transducers: Theoretical Aspects and Practical Applications.” 1995. Doctoral Dissertation, Delft University of Technology. Accessed March 03, 2021. http://resolver.tudelft.nl/uuid:f0a81df4-4e2b-42b7-8ac9-46b1c8c5111a ; urn:NBN:nl:ui:24-uuid:f0a81df4-4e2b-42b7-8ac9-46b1c8c5111a ; urn:NBN:nl:ui:24-uuid:f0a81df4-4e2b-42b7-8ac9-46b1c8c5111a ; http://resolver.tudelft.nl/uuid:f0a81df4-4e2b-42b7-8ac9-46b1c8c5111a.

MLA Handbook (7th Edition):

Bonse, M H W. “Capacitive Position Transducers: Theoretical Aspects and Practical Applications.” 1995. Web. 03 Mar 2021.

Vancouver:

Bonse MHW. Capacitive Position Transducers: Theoretical Aspects and Practical Applications. [Internet] [Doctoral dissertation]. Delft University of Technology; 1995. [cited 2021 Mar 03]. Available from: http://resolver.tudelft.nl/uuid:f0a81df4-4e2b-42b7-8ac9-46b1c8c5111a ; urn:NBN:nl:ui:24-uuid:f0a81df4-4e2b-42b7-8ac9-46b1c8c5111a ; urn:NBN:nl:ui:24-uuid:f0a81df4-4e2b-42b7-8ac9-46b1c8c5111a ; http://resolver.tudelft.nl/uuid:f0a81df4-4e2b-42b7-8ac9-46b1c8c5111a.

Council of Science Editors:

Bonse MHW. Capacitive Position Transducers: Theoretical Aspects and Practical Applications. [Doctoral Dissertation]. Delft University of Technology; 1995. Available from: http://resolver.tudelft.nl/uuid:f0a81df4-4e2b-42b7-8ac9-46b1c8c5111a ; urn:NBN:nl:ui:24-uuid:f0a81df4-4e2b-42b7-8ac9-46b1c8c5111a ; urn:NBN:nl:ui:24-uuid:f0a81df4-4e2b-42b7-8ac9-46b1c8c5111a ; http://resolver.tudelft.nl/uuid:f0a81df4-4e2b-42b7-8ac9-46b1c8c5111a


University of Waterloo

27. CHEN, ALBERT I-HSIANG. Row-Column Capacitive Micromachined Ultrasonic Transducers for Medical Imaging.

Degree: 2016, University of Waterloo

 Ultrasound imaging plays an important role in modern medical diagnosis. Recent progress in real-time 3-D ultrasound imaging can offer critical information such as the accurate… (more)

Subjects/Keywords: mems; cmut; flexible ultrasonic transducer array; row-column addressing ultrasound

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

CHEN, A. I. (2016). Row-Column Capacitive Micromachined Ultrasonic Transducers for Medical Imaging. (Thesis). University of Waterloo. Retrieved from http://hdl.handle.net/10012/11105

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

CHEN, ALBERT I-HSIANG. “Row-Column Capacitive Micromachined Ultrasonic Transducers for Medical Imaging.” 2016. Thesis, University of Waterloo. Accessed March 03, 2021. http://hdl.handle.net/10012/11105.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

CHEN, ALBERT I-HSIANG. “Row-Column Capacitive Micromachined Ultrasonic Transducers for Medical Imaging.” 2016. Web. 03 Mar 2021.

Vancouver:

CHEN AI. Row-Column Capacitive Micromachined Ultrasonic Transducers for Medical Imaging. [Internet] [Thesis]. University of Waterloo; 2016. [cited 2021 Mar 03]. Available from: http://hdl.handle.net/10012/11105.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

CHEN AI. Row-Column Capacitive Micromachined Ultrasonic Transducers for Medical Imaging. [Thesis]. University of Waterloo; 2016. Available from: http://hdl.handle.net/10012/11105

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


The Ohio State University

28. Shieh, Long-Chin. A study of frequency variation in ultrasonic transducers.

Degree: PhD, Graduate School, 1974, The Ohio State University

Subjects/Keywords: Education; Ultrasonic transducers

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Shieh, L. (1974). A study of frequency variation in ultrasonic transducers. (Doctoral Dissertation). The Ohio State University. Retrieved from http://rave.ohiolink.edu/etdc/view?acc_num=osu1486979835070119

Chicago Manual of Style (16th Edition):

Shieh, Long-Chin. “A study of frequency variation in ultrasonic transducers.” 1974. Doctoral Dissertation, The Ohio State University. Accessed March 03, 2021. http://rave.ohiolink.edu/etdc/view?acc_num=osu1486979835070119.

MLA Handbook (7th Edition):

Shieh, Long-Chin. “A study of frequency variation in ultrasonic transducers.” 1974. Web. 03 Mar 2021.

Vancouver:

Shieh L. A study of frequency variation in ultrasonic transducers. [Internet] [Doctoral dissertation]. The Ohio State University; 1974. [cited 2021 Mar 03]. Available from: http://rave.ohiolink.edu/etdc/view?acc_num=osu1486979835070119.

Council of Science Editors:

Shieh L. A study of frequency variation in ultrasonic transducers. [Doctoral Dissertation]. The Ohio State University; 1974. Available from: http://rave.ohiolink.edu/etdc/view?acc_num=osu1486979835070119


University College Cork

29. Jiang, Wentao. Airborne ultrasonic communications using multiple parallel channels.

Degree: 2016, University College Cork

 Concerns still exist over the safety of prolonged exposure to radio frequency (RF) wireless transmissions and there are also potential data security issues due to… (more)

Subjects/Keywords: Airborne ultrasonic communication; Orthogonal frequency division multiplexing; Capacitive ultrasonic transducer

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Jiang, W. (2016). Airborne ultrasonic communications using multiple parallel channels. (Thesis). University College Cork. Retrieved from http://hdl.handle.net/10468/3913

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Jiang, Wentao. “Airborne ultrasonic communications using multiple parallel channels.” 2016. Thesis, University College Cork. Accessed March 03, 2021. http://hdl.handle.net/10468/3913.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Jiang, Wentao. “Airborne ultrasonic communications using multiple parallel channels.” 2016. Web. 03 Mar 2021.

Vancouver:

Jiang W. Airborne ultrasonic communications using multiple parallel channels. [Internet] [Thesis]. University College Cork; 2016. [cited 2021 Mar 03]. Available from: http://hdl.handle.net/10468/3913.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Jiang W. Airborne ultrasonic communications using multiple parallel channels. [Thesis]. University College Cork; 2016. Available from: http://hdl.handle.net/10468/3913

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of New Mexico

30. Cheng, Xiaoyang. Minimally invasive capacitive micromachined ultrasonic transducers array For biomedical applications.

Degree: Electrical and Computer Engineering, 2008, University of New Mexico

 Ultrasound covers a broad range of applications from underwater exploration and nondestructive evaluation of materials to medical diagnosis and treatment. The ultrasonic transducer plays an… (more)

Subjects/Keywords: Transducers; Biomedical; Ultrasonic transducers; Microelectromechanical systems

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Cheng, X. (2008). Minimally invasive capacitive micromachined ultrasonic transducers array For biomedical applications. (Doctoral Dissertation). University of New Mexico. Retrieved from http://hdl.handle.net/1928/6916

Chicago Manual of Style (16th Edition):

Cheng, Xiaoyang. “Minimally invasive capacitive micromachined ultrasonic transducers array For biomedical applications.” 2008. Doctoral Dissertation, University of New Mexico. Accessed March 03, 2021. http://hdl.handle.net/1928/6916.

MLA Handbook (7th Edition):

Cheng, Xiaoyang. “Minimally invasive capacitive micromachined ultrasonic transducers array For biomedical applications.” 2008. Web. 03 Mar 2021.

Vancouver:

Cheng X. Minimally invasive capacitive micromachined ultrasonic transducers array For biomedical applications. [Internet] [Doctoral dissertation]. University of New Mexico; 2008. [cited 2021 Mar 03]. Available from: http://hdl.handle.net/1928/6916.

Council of Science Editors:

Cheng X. Minimally invasive capacitive micromachined ultrasonic transducers array For biomedical applications. [Doctoral Dissertation]. University of New Mexico; 2008. Available from: http://hdl.handle.net/1928/6916

[1] [2] [3] [4] [5] … [83]

.