Advanced search options

Advanced Search Options 🞨

Browse by author name (“Author name starts with…”).

Find ETDs with:

in
/  
in
/  
in
/  
in

Written in Published in Earliest date Latest date

Sorted by

Results per page:

Sorted by: relevance · author · university · date | New search

You searched for subject:(CAD CAM Denture). Showing records 1 – 11 of 11 total matches.

Search Limiters

Last 2 Years | English Only

No search limiters apply to these results.

▼ Search Limiters


Texas A&M University

1. Buie, John Morgan. Dimensional Change of Denture PMMA Processed to CAD/CAM Produced Denture Bases.

Degree: MS, Prosthodontics, 2019, Texas A&M University

 Purpose: The purpose of this study was to carry out a three-dimensional analysis of the processing distortion that occurs when acrylic resin and teeth are… (more)

Subjects/Keywords: denture base; processing changes; CAD/CAM denture

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Buie, J. M. (2019). Dimensional Change of Denture PMMA Processed to CAD/CAM Produced Denture Bases. (Masters Thesis). Texas A&M University. Retrieved from http://hdl.handle.net/1969.1/187948

Chicago Manual of Style (16th Edition):

Buie, John Morgan. “Dimensional Change of Denture PMMA Processed to CAD/CAM Produced Denture Bases.” 2019. Masters Thesis, Texas A&M University. Accessed May 10, 2021. http://hdl.handle.net/1969.1/187948.

MLA Handbook (7th Edition):

Buie, John Morgan. “Dimensional Change of Denture PMMA Processed to CAD/CAM Produced Denture Bases.” 2019. Web. 10 May 2021.

Vancouver:

Buie JM. Dimensional Change of Denture PMMA Processed to CAD/CAM Produced Denture Bases. [Internet] [Masters thesis]. Texas A&M University; 2019. [cited 2021 May 10]. Available from: http://hdl.handle.net/1969.1/187948.

Council of Science Editors:

Buie JM. Dimensional Change of Denture PMMA Processed to CAD/CAM Produced Denture Bases. [Masters Thesis]. Texas A&M University; 2019. Available from: http://hdl.handle.net/1969.1/187948


Texas A&M University

2. Rawas, Mohammed. Evaluation of Fit of CAD/CAM Record Bases Produced by Milled and Printed Methods.

Degree: MS, Oral Biology, 2019, Texas A&M University

 Purpose: The purpose of the study was to evaluate the fit of two CAD/CAM record bases produced by milling and printing technology. Material and Methods:… (more)

Subjects/Keywords: fit; CAD/CAM record bases; milled record bases; printed record bases; denture

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Rawas, M. (2019). Evaluation of Fit of CAD/CAM Record Bases Produced by Milled and Printed Methods. (Masters Thesis). Texas A&M University. Retrieved from http://hdl.handle.net/1969.1/185070

Chicago Manual of Style (16th Edition):

Rawas, Mohammed. “Evaluation of Fit of CAD/CAM Record Bases Produced by Milled and Printed Methods.” 2019. Masters Thesis, Texas A&M University. Accessed May 10, 2021. http://hdl.handle.net/1969.1/185070.

MLA Handbook (7th Edition):

Rawas, Mohammed. “Evaluation of Fit of CAD/CAM Record Bases Produced by Milled and Printed Methods.” 2019. Web. 10 May 2021.

Vancouver:

Rawas M. Evaluation of Fit of CAD/CAM Record Bases Produced by Milled and Printed Methods. [Internet] [Masters thesis]. Texas A&M University; 2019. [cited 2021 May 10]. Available from: http://hdl.handle.net/1969.1/185070.

Council of Science Editors:

Rawas M. Evaluation of Fit of CAD/CAM Record Bases Produced by Milled and Printed Methods. [Masters Thesis]. Texas A&M University; 2019. Available from: http://hdl.handle.net/1969.1/185070

3. Ahmad, Hogir Ismail. Fracture strength of three-unit fixed partial denture in lithium disilicate, press versus milled, in-vitro study.

Degree: Faculty of Odontology, 2019, Malmö University

Syfte: Syftet med denna studie är att jämföra fraktur styrkan och frakturmönster hos tre-leds broar utförda i litiumdisilikat när broarna tillverkas genom pressteknik jämfört… (more)

Subjects/Keywords: Fracture strength; Three-unit fixed partial denture; FPD; Lithium disilicate; Conventional Manufacturing; CAD/CAM; In vitro; Fracture mode; Medical and Health Sciences; Medicin och hälsovetenskap

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Ahmad, H. I. (2019). Fracture strength of three-unit fixed partial denture in lithium disilicate, press versus milled, in-vitro study. (Thesis). Malmö University. Retrieved from http://urn.kb.se/resolve?urn=urn:nbn:se:mau:diva-19698

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Ahmad, Hogir Ismail. “Fracture strength of three-unit fixed partial denture in lithium disilicate, press versus milled, in-vitro study.” 2019. Thesis, Malmö University. Accessed May 10, 2021. http://urn.kb.se/resolve?urn=urn:nbn:se:mau:diva-19698.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Ahmad, Hogir Ismail. “Fracture strength of three-unit fixed partial denture in lithium disilicate, press versus milled, in-vitro study.” 2019. Web. 10 May 2021.

Vancouver:

Ahmad HI. Fracture strength of three-unit fixed partial denture in lithium disilicate, press versus milled, in-vitro study. [Internet] [Thesis]. Malmö University; 2019. [cited 2021 May 10]. Available from: http://urn.kb.se/resolve?urn=urn:nbn:se:mau:diva-19698.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Ahmad HI. Fracture strength of three-unit fixed partial denture in lithium disilicate, press versus milled, in-vitro study. [Thesis]. Malmö University; 2019. Available from: http://urn.kb.se/resolve?urn=urn:nbn:se:mau:diva-19698

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Illinois – Chicago

4. Christopher William Coffey (7950377). Differences Between Conventionally and CAD/CAM Complete Removable Dental Prosthesis - Subjective Analysis.

Degree: 2018, University of Illinois – Chicago

 The longer life span of human beings has resulted in a high percentage of the population that is in need for maxillary and mandibular prosthetic… (more)

Subjects/Keywords: Uncategorized; Digital Denture, Dental, Digital, CAD/CAM, CAD/CAM Denture

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

(7950377), C. W. C. (2018). Differences Between Conventionally and CAD/CAM Complete Removable Dental Prosthesis - Subjective Analysis. (Thesis). University of Illinois – Chicago. Retrieved from http://hdl.handle.net/10027/22714

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

(7950377), Christopher William Coffey. “Differences Between Conventionally and CAD/CAM Complete Removable Dental Prosthesis - Subjective Analysis.” 2018. Thesis, University of Illinois – Chicago. Accessed May 10, 2021. http://hdl.handle.net/10027/22714.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

(7950377), Christopher William Coffey. “Differences Between Conventionally and CAD/CAM Complete Removable Dental Prosthesis - Subjective Analysis.” 2018. Web. 10 May 2021.

Vancouver:

(7950377) CWC. Differences Between Conventionally and CAD/CAM Complete Removable Dental Prosthesis - Subjective Analysis. [Internet] [Thesis]. University of Illinois – Chicago; 2018. [cited 2021 May 10]. Available from: http://hdl.handle.net/10027/22714.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

(7950377) CWC. Differences Between Conventionally and CAD/CAM Complete Removable Dental Prosthesis - Subjective Analysis. [Thesis]. University of Illinois – Chicago; 2018. Available from: http://hdl.handle.net/10027/22714

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

5. Aguirre, Brian C. Flexural Strength of Denture Base Acrylic Resins Processed by Conventional and CAD/CAM Methods.

Degree: MS, Oral Biology, 2017, Texas A&M University

 High flexural strength is a desirable property for denture base resins. Currently there is a lack of published studies evaluating the physical properties of newer… (more)

Subjects/Keywords: Denture; acrylic; flexural strength; CAD/CAM; mill

…by the method in which it is processed. Pre-polymerized CAD/CAM milled denture resin… …CAD/CAM (Computer-Aided Design/Computer Aided Manufacturing) was introduced in the… …CAD/CAM. (6) Several developments in CAD/CAM technology for dentistry occured in… …them, Dr. Moermann and Dr. Andersson, went on to develop two modern CAD/CAM systems CEREC… …processed CAD/CAM milling. The null hypothesis was that there is no significant difference in the… 

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Aguirre, B. C. (2017). Flexural Strength of Denture Base Acrylic Resins Processed by Conventional and CAD/CAM Methods. (Masters Thesis). Texas A&M University. Retrieved from http://hdl.handle.net/1969.1/161547

Chicago Manual of Style (16th Edition):

Aguirre, Brian C. “Flexural Strength of Denture Base Acrylic Resins Processed by Conventional and CAD/CAM Methods.” 2017. Masters Thesis, Texas A&M University. Accessed May 10, 2021. http://hdl.handle.net/1969.1/161547.

MLA Handbook (7th Edition):

Aguirre, Brian C. “Flexural Strength of Denture Base Acrylic Resins Processed by Conventional and CAD/CAM Methods.” 2017. Web. 10 May 2021.

Vancouver:

Aguirre BC. Flexural Strength of Denture Base Acrylic Resins Processed by Conventional and CAD/CAM Methods. [Internet] [Masters thesis]. Texas A&M University; 2017. [cited 2021 May 10]. Available from: http://hdl.handle.net/1969.1/161547.

Council of Science Editors:

Aguirre BC. Flexural Strength of Denture Base Acrylic Resins Processed by Conventional and CAD/CAM Methods. [Masters Thesis]. Texas A&M University; 2017. Available from: http://hdl.handle.net/1969.1/161547

6. Jia-mahasap, Wissanee. Comparative assessment of conventional vs. CAD/CAM complete denture fabrication techniques on patient satisfaction, quality of life and prosthesis biofilm.

Degree: MS, Oral Science, 2017, University of Iowa

  Objectives: The primary objective was to assess the impact of two denture fabrication techniques, conventional and CAD/CAM, on oral health-related quality of life (OHRQoL)… (more)

Subjects/Keywords: CAD/CAM; CAD/CAM complete denture; Complete denture; digital complete denture; Oral health-related quality of life; Patient satisfaction; Oral Biology and Oral Pathology

…45 Figure 11 CAD/CAM complete denture… …acrylic denture from CAD/CAM technology. This study indicated that it is possible to fabricate a… …complete denture using a CAD/CAM system. Goodacre et al. Described clinical procedure used to… …procedures of two available CAD/CAM complete (2013)(53) denture systems… …x28;66) claimed by manufacturer for CAD/CAM complete denture. The author found some… 

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Jia-mahasap, W. (2017). Comparative assessment of conventional vs. CAD/CAM complete denture fabrication techniques on patient satisfaction, quality of life and prosthesis biofilm. (Masters Thesis). University of Iowa. Retrieved from https://ir.uiowa.edu/etd/5526

Chicago Manual of Style (16th Edition):

Jia-mahasap, Wissanee. “Comparative assessment of conventional vs. CAD/CAM complete denture fabrication techniques on patient satisfaction, quality of life and prosthesis biofilm.” 2017. Masters Thesis, University of Iowa. Accessed May 10, 2021. https://ir.uiowa.edu/etd/5526.

MLA Handbook (7th Edition):

Jia-mahasap, Wissanee. “Comparative assessment of conventional vs. CAD/CAM complete denture fabrication techniques on patient satisfaction, quality of life and prosthesis biofilm.” 2017. Web. 10 May 2021.

Vancouver:

Jia-mahasap W. Comparative assessment of conventional vs. CAD/CAM complete denture fabrication techniques on patient satisfaction, quality of life and prosthesis biofilm. [Internet] [Masters thesis]. University of Iowa; 2017. [cited 2021 May 10]. Available from: https://ir.uiowa.edu/etd/5526.

Council of Science Editors:

Jia-mahasap W. Comparative assessment of conventional vs. CAD/CAM complete denture fabrication techniques on patient satisfaction, quality of life and prosthesis biofilm. [Masters Thesis]. University of Iowa; 2017. Available from: https://ir.uiowa.edu/etd/5526


Loma Linda University

7. AlHelal, Abdulaziz Abdullah. Comparison of Retention between Milled and Conventional Denture Bases: A Clinical Study.

Degree: MS, Prosthodontics, 2016, Loma Linda University

  The advancement in dental material technology led to the improvement in the fabrication method of PMMA denture bases. Denture base adaptation can be influenced… (more)

Subjects/Keywords: Dentistry; Medicine and Health Sciences; Prosthodontics and Prosthodontology; Denture Bases; Dental Prosthesis Retention; Dental Stress Analysis; Dental Materials  – Analysis; CAD/CAM dentures; Pre-polymerized PMMA acrylic resin; Polymerization shrinkage; Dental Material Technology; Fabrication methods

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

AlHelal, A. A. (2016). Comparison of Retention between Milled and Conventional Denture Bases: A Clinical Study. (Thesis). Loma Linda University. Retrieved from https://scholarsrepository.llu.edu/etd/323

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

AlHelal, Abdulaziz Abdullah. “Comparison of Retention between Milled and Conventional Denture Bases: A Clinical Study.” 2016. Thesis, Loma Linda University. Accessed May 10, 2021. https://scholarsrepository.llu.edu/etd/323.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

AlHelal, Abdulaziz Abdullah. “Comparison of Retention between Milled and Conventional Denture Bases: A Clinical Study.” 2016. Web. 10 May 2021.

Vancouver:

AlHelal AA. Comparison of Retention between Milled and Conventional Denture Bases: A Clinical Study. [Internet] [Thesis]. Loma Linda University; 2016. [cited 2021 May 10]. Available from: https://scholarsrepository.llu.edu/etd/323.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

AlHelal AA. Comparison of Retention between Milled and Conventional Denture Bases: A Clinical Study. [Thesis]. Loma Linda University; 2016. Available from: https://scholarsrepository.llu.edu/etd/323

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

8. Al-Haddad, Ala'A. Characterisation and Performance of Fibre-Reinforced Composite Restorations.

Degree: 2015, University of Manchester

 In the modern era of metal-free minimally-invasive dentistry, there is a growing tendency toward using metal-free restorative alternatives that provide not only excellent aesthetics but… (more)

Subjects/Keywords: Fibre-reinforced composite; Oral scanner; Tooth wear; microhardness; edge strength; Shear bond strength; fatigue; load bearing capacity; crown; Fixed partial denture; CAD/CAM; digital dentistry

…indirect PRC (Sinfony), were compared with those made of two CAD/CAM alternatives… …verses CAD/CAM alternatives).  ADR/AADR/CADR General Session & Exhibition in Boston… …fracture FMax Maximum force FPD Fixed partial denture FRC Fibre-reinforced composite FRC-S… …concept has been examined with a number of polymeric dental materials, such as denture base PMMA… …restricted to denture bases due to the problems in aesthetics and handling [45, 75, 83]… 

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Al-Haddad, A. (2015). Characterisation and Performance of Fibre-Reinforced Composite Restorations. (Doctoral Dissertation). University of Manchester. Retrieved from http://www.manchester.ac.uk/escholar/uk-ac-man-scw:283118

Chicago Manual of Style (16th Edition):

Al-Haddad, Ala'A. “Characterisation and Performance of Fibre-Reinforced Composite Restorations.” 2015. Doctoral Dissertation, University of Manchester. Accessed May 10, 2021. http://www.manchester.ac.uk/escholar/uk-ac-man-scw:283118.

MLA Handbook (7th Edition):

Al-Haddad, Ala'A. “Characterisation and Performance of Fibre-Reinforced Composite Restorations.” 2015. Web. 10 May 2021.

Vancouver:

Al-Haddad A. Characterisation and Performance of Fibre-Reinforced Composite Restorations. [Internet] [Doctoral dissertation]. University of Manchester; 2015. [cited 2021 May 10]. Available from: http://www.manchester.ac.uk/escholar/uk-ac-man-scw:283118.

Council of Science Editors:

Al-Haddad A. Characterisation and Performance of Fibre-Reinforced Composite Restorations. [Doctoral Dissertation]. University of Manchester; 2015. Available from: http://www.manchester.ac.uk/escholar/uk-ac-man-scw:283118


University of Manchester

9. Al-Haddad, Ala'A. Characterisation and performance of fibre-reinforced composite restorations.

Degree: PhD, 2015, University of Manchester

 In the modern era of metal-free minimally-invasive dentistry, there is a growing tendency toward using metal-free restorative alternatives that provide not only excellent aesthetics but… (more)

Subjects/Keywords: 617.6; Fibre-reinforced composite; Oral scanner; Tooth wear; microhardness; edge strength; Shear bond strength; fatigue; load bearing capacity; crown; Fixed partial denture; CAD/CAM; digital dentistry

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Al-Haddad, A. (2015). Characterisation and performance of fibre-reinforced composite restorations. (Doctoral Dissertation). University of Manchester. Retrieved from https://www.research.manchester.ac.uk/portal/en/theses/characterisation-and-performance-of-fibrereinforced-composite-restorations(bdcc1685-a341-4b8a-9e4a-542467f4b321).html ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.677794

Chicago Manual of Style (16th Edition):

Al-Haddad, Ala'A. “Characterisation and performance of fibre-reinforced composite restorations.” 2015. Doctoral Dissertation, University of Manchester. Accessed May 10, 2021. https://www.research.manchester.ac.uk/portal/en/theses/characterisation-and-performance-of-fibrereinforced-composite-restorations(bdcc1685-a341-4b8a-9e4a-542467f4b321).html ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.677794.

MLA Handbook (7th Edition):

Al-Haddad, Ala'A. “Characterisation and performance of fibre-reinforced composite restorations.” 2015. Web. 10 May 2021.

Vancouver:

Al-Haddad A. Characterisation and performance of fibre-reinforced composite restorations. [Internet] [Doctoral dissertation]. University of Manchester; 2015. [cited 2021 May 10]. Available from: https://www.research.manchester.ac.uk/portal/en/theses/characterisation-and-performance-of-fibrereinforced-composite-restorations(bdcc1685-a341-4b8a-9e4a-542467f4b321).html ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.677794.

Council of Science Editors:

Al-Haddad A. Characterisation and performance of fibre-reinforced composite restorations. [Doctoral Dissertation]. University of Manchester; 2015. Available from: https://www.research.manchester.ac.uk/portal/en/theses/characterisation-and-performance-of-fibrereinforced-composite-restorations(bdcc1685-a341-4b8a-9e4a-542467f4b321).html ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.677794

10. Moreira, Marlene Tavares. Avaliação dos tipos de reabilitações fixas dento-suportadas em dentes anteriores.

Degree: 2013, Universidade Fernando Pessoa

Projeto de Pós-Graduação/Dissertação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Medicina Dentária

Introdução: O conhecimento das… (more)

Subjects/Keywords: Cerâmic crowns; Metalceramic crowns; CAD-CAM; Fixed partial denture; Dental techonology; Dental materials; Prótese parcial fixa; Cerâmica dentária; Procera; IPS Empress; In-Ceram; Coroas dentárias

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Moreira, M. T. (2013). Avaliação dos tipos de reabilitações fixas dento-suportadas em dentes anteriores. (Thesis). Universidade Fernando Pessoa. Retrieved from http://www.rcaap.pt/detail.jsp?id=oai:bdigital.ufp.pt:10284/4449

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Moreira, Marlene Tavares. “Avaliação dos tipos de reabilitações fixas dento-suportadas em dentes anteriores.” 2013. Thesis, Universidade Fernando Pessoa. Accessed May 10, 2021. http://www.rcaap.pt/detail.jsp?id=oai:bdigital.ufp.pt:10284/4449.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Moreira, Marlene Tavares. “Avaliação dos tipos de reabilitações fixas dento-suportadas em dentes anteriores.” 2013. Web. 10 May 2021.

Vancouver:

Moreira MT. Avaliação dos tipos de reabilitações fixas dento-suportadas em dentes anteriores. [Internet] [Thesis]. Universidade Fernando Pessoa; 2013. [cited 2021 May 10]. Available from: http://www.rcaap.pt/detail.jsp?id=oai:bdigital.ufp.pt:10284/4449.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Moreira MT. Avaliação dos tipos de reabilitações fixas dento-suportadas em dentes anteriores. [Thesis]. Universidade Fernando Pessoa; 2013. Available from: http://www.rcaap.pt/detail.jsp?id=oai:bdigital.ufp.pt:10284/4449

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

11. Alvaro Luis Ichi. Análise da viabilidade da aplicação da tecnologia CAD-CAM por prototipagem rápida na confecção de estrutura metálica da prótese parcial removível comparando-a ao método convencional.

Degree: 2010, University of São Paulo

A tecnologia CAD-CAM vem sendo aplicada há mais de uma década para a confecção de trabalhos protéticos odontológicos e bucomaxilofaciais. A tecnologia de prototipagem rápida… (more)

Subjects/Keywords: CAD-CAM; Informática Odontológica; Odontologia Geriátrica; Prótese Parcial Removível; CAD-CAM; Dental Informatics; Geriatric Dentistry; Removable Partial Denture

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Ichi, A. L. (2010). Análise da viabilidade da aplicação da tecnologia CAD-CAM por prototipagem rápida na confecção de estrutura metálica da prótese parcial removível comparando-a ao método convencional. (Masters Thesis). University of São Paulo. Retrieved from http://www.teses.usp.br/teses/disponiveis/23/23150/tde-22122010-120126/

Chicago Manual of Style (16th Edition):

Ichi, Alvaro Luis. “Análise da viabilidade da aplicação da tecnologia CAD-CAM por prototipagem rápida na confecção de estrutura metálica da prótese parcial removível comparando-a ao método convencional.” 2010. Masters Thesis, University of São Paulo. Accessed May 10, 2021. http://www.teses.usp.br/teses/disponiveis/23/23150/tde-22122010-120126/.

MLA Handbook (7th Edition):

Ichi, Alvaro Luis. “Análise da viabilidade da aplicação da tecnologia CAD-CAM por prototipagem rápida na confecção de estrutura metálica da prótese parcial removível comparando-a ao método convencional.” 2010. Web. 10 May 2021.

Vancouver:

Ichi AL. Análise da viabilidade da aplicação da tecnologia CAD-CAM por prototipagem rápida na confecção de estrutura metálica da prótese parcial removível comparando-a ao método convencional. [Internet] [Masters thesis]. University of São Paulo; 2010. [cited 2021 May 10]. Available from: http://www.teses.usp.br/teses/disponiveis/23/23150/tde-22122010-120126/.

Council of Science Editors:

Ichi AL. Análise da viabilidade da aplicação da tecnologia CAD-CAM por prototipagem rápida na confecção de estrutura metálica da prótese parcial removível comparando-a ao método convencional. [Masters Thesis]. University of São Paulo; 2010. Available from: http://www.teses.usp.br/teses/disponiveis/23/23150/tde-22122010-120126/

.