Advanced search options

Advanced Search Options 🞨

Browse by author name (“Author name starts with…”).

Find ETDs with:

in
/  
in
/  
in
/  
in

Written in Published in Earliest date Latest date

Sorted by

Results per page:

Sorted by: relevance · author · university · dateNew search

You searched for subject:(Air Leakage). Showing records 1 – 25 of 25 total matches.

Search Limiters

Last 2 Years | English Only

No search limiters apply to these results.

▼ Search Limiters


North-West University

1. Van Tonder, Adriaan Jacobus Marthinus. Sustaining compressed air DSM project savings using an air leakage management system / A.J.M. van Tonder .

Degree: 2010, North-West University

 Unreliable and unsustainable electricity supply has been experienced in South Africa since 2007. Eskom implemented Demand Side Management (DSM) as a short-term solution to alleviate… (more)

Subjects/Keywords: Compressed air; DSM; Leakage detection; Sustainability; Project savings; Reporting; Energy efficiency

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Van Tonder, A. J. M. (2010). Sustaining compressed air DSM project savings using an air leakage management system / A.J.M. van Tonder . (Thesis). North-West University. Retrieved from http://hdl.handle.net/10394/4458

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Van Tonder, Adriaan Jacobus Marthinus. “Sustaining compressed air DSM project savings using an air leakage management system / A.J.M. van Tonder .” 2010. Thesis, North-West University. Accessed January 17, 2020. http://hdl.handle.net/10394/4458.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Van Tonder, Adriaan Jacobus Marthinus. “Sustaining compressed air DSM project savings using an air leakage management system / A.J.M. van Tonder .” 2010. Web. 17 Jan 2020.

Vancouver:

Van Tonder AJM. Sustaining compressed air DSM project savings using an air leakage management system / A.J.M. van Tonder . [Internet] [Thesis]. North-West University; 2010. [cited 2020 Jan 17]. Available from: http://hdl.handle.net/10394/4458.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Van Tonder AJM. Sustaining compressed air DSM project savings using an air leakage management system / A.J.M. van Tonder . [Thesis]. North-West University; 2010. Available from: http://hdl.handle.net/10394/4458

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Toronto

2. Stanton, David. Using Component Air Leakage Models to Predict the Post-Retrofit Airtightness of a High Rise Residential Building: A Case Study.

Degree: 2018, University of Toronto

In this study, CONTAM 3.2, a modeling software that uses component air leakage rates, was used to estimate post-retrofit improvements in airtightness. A 12 storey… (more)

Subjects/Keywords: Air Leakage; Airtightness; CONTAM; Factorial Analysis; Modelling; Monte Carlo; 0543

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Stanton, D. (2018). Using Component Air Leakage Models to Predict the Post-Retrofit Airtightness of a High Rise Residential Building: A Case Study. (Masters Thesis). University of Toronto. Retrieved from http://hdl.handle.net/1807/89559

Chicago Manual of Style (16th Edition):

Stanton, David. “Using Component Air Leakage Models to Predict the Post-Retrofit Airtightness of a High Rise Residential Building: A Case Study.” 2018. Masters Thesis, University of Toronto. Accessed January 17, 2020. http://hdl.handle.net/1807/89559.

MLA Handbook (7th Edition):

Stanton, David. “Using Component Air Leakage Models to Predict the Post-Retrofit Airtightness of a High Rise Residential Building: A Case Study.” 2018. Web. 17 Jan 2020.

Vancouver:

Stanton D. Using Component Air Leakage Models to Predict the Post-Retrofit Airtightness of a High Rise Residential Building: A Case Study. [Internet] [Masters thesis]. University of Toronto; 2018. [cited 2020 Jan 17]. Available from: http://hdl.handle.net/1807/89559.

Council of Science Editors:

Stanton D. Using Component Air Leakage Models to Predict the Post-Retrofit Airtightness of a High Rise Residential Building: A Case Study. [Masters Thesis]. University of Toronto; 2018. Available from: http://hdl.handle.net/1807/89559


Linköping University

3. Martin, Kågebjer. Diagnosis of a compressed air system in a heavy vehicle.

Degree: Vehicular Systems, 2011, Linköping University

Compressed air has in the past been considered as a free resource in heavy vehicles.The recent years work to minimize fuel consumption has however… (more)

Subjects/Keywords: Air leakage detection; Parameter estimation; System modelling; TECHNOLOGY; TEKNIKVETENSKAP

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Martin, K. (2011). Diagnosis of a compressed air system in a heavy vehicle. (Thesis). Linköping University. Retrieved from http://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-71357

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Martin, Kågebjer. “Diagnosis of a compressed air system in a heavy vehicle.” 2011. Thesis, Linköping University. Accessed January 17, 2020. http://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-71357.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Martin, Kågebjer. “Diagnosis of a compressed air system in a heavy vehicle.” 2011. Web. 17 Jan 2020.

Vancouver:

Martin K. Diagnosis of a compressed air system in a heavy vehicle. [Internet] [Thesis]. Linköping University; 2011. [cited 2020 Jan 17]. Available from: http://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-71357.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Martin K. Diagnosis of a compressed air system in a heavy vehicle. [Thesis]. Linköping University; 2011. Available from: http://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-71357

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

4. Shoai Naini, Shervin. EXPERIMENTAL INVESTIGATION OF HEAT LEAKAGE AND AIR LEAKAGE IN DOMESTIC REFRIGERATORS.

Degree: MS, Mechanical Engineering, 2015, Clemson University

 The optimization of the energy consumption in household refrigerators should consider the influence of the gasket which determines the heat transfer and air infiltration rate.… (more)

Subjects/Keywords: Air Infiltration; Air Leakage; Gasket; Heat Leakage; Refrigerators; Mechanical Engineering

…44 3 EXPERIMENTAL INVESTIGATION ON AIR LEAKAGE FOR DOMESTIC REFRIGERATOR… …compared the air leakage through one new and one old gasket installed at a time on a sample… …Evaluation of the “gasket heat leakage” and the “refrigerator air infiltration” are the primary… …methodology to evaluate the gasket heat leakage, estimate the air infiltration rate and its… …leakage, measure air exchange rate and its corresponding energy heat loss in the sample… 

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Shoai Naini, S. (2015). EXPERIMENTAL INVESTIGATION OF HEAT LEAKAGE AND AIR LEAKAGE IN DOMESTIC REFRIGERATORS. (Masters Thesis). Clemson University. Retrieved from https://tigerprints.clemson.edu/all_theses/2246

Chicago Manual of Style (16th Edition):

Shoai Naini, Shervin. “EXPERIMENTAL INVESTIGATION OF HEAT LEAKAGE AND AIR LEAKAGE IN DOMESTIC REFRIGERATORS.” 2015. Masters Thesis, Clemson University. Accessed January 17, 2020. https://tigerprints.clemson.edu/all_theses/2246.

MLA Handbook (7th Edition):

Shoai Naini, Shervin. “EXPERIMENTAL INVESTIGATION OF HEAT LEAKAGE AND AIR LEAKAGE IN DOMESTIC REFRIGERATORS.” 2015. Web. 17 Jan 2020.

Vancouver:

Shoai Naini S. EXPERIMENTAL INVESTIGATION OF HEAT LEAKAGE AND AIR LEAKAGE IN DOMESTIC REFRIGERATORS. [Internet] [Masters thesis]. Clemson University; 2015. [cited 2020 Jan 17]. Available from: https://tigerprints.clemson.edu/all_theses/2246.

Council of Science Editors:

Shoai Naini S. EXPERIMENTAL INVESTIGATION OF HEAT LEAKAGE AND AIR LEAKAGE IN DOMESTIC REFRIGERATORS. [Masters Thesis]. Clemson University; 2015. Available from: https://tigerprints.clemson.edu/all_theses/2246


Texas A&M University

5. Honang, Hanniel Jouvain. Reactor Physics Analysis of Air-Cooled Nuclear System.

Degree: MS, Nuclear Engineering, 2016, Texas A&M University

 The design of SACR? (Small Air-Cooled Reactor) fixated on evaluations of air as a potential coolant. The assessment offered in this thesis focused on reactor… (more)

Subjects/Keywords: air; gas; reactor; modular; MCNP; Argon; oxidation; reflector; burnup; leakage; Uranium; cycle; fuel; assembly

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Honang, H. J. (2016). Reactor Physics Analysis of Air-Cooled Nuclear System. (Masters Thesis). Texas A&M University. Retrieved from http://hdl.handle.net/1969.1/156990

Chicago Manual of Style (16th Edition):

Honang, Hanniel Jouvain. “Reactor Physics Analysis of Air-Cooled Nuclear System.” 2016. Masters Thesis, Texas A&M University. Accessed January 17, 2020. http://hdl.handle.net/1969.1/156990.

MLA Handbook (7th Edition):

Honang, Hanniel Jouvain. “Reactor Physics Analysis of Air-Cooled Nuclear System.” 2016. Web. 17 Jan 2020.

Vancouver:

Honang HJ. Reactor Physics Analysis of Air-Cooled Nuclear System. [Internet] [Masters thesis]. Texas A&M University; 2016. [cited 2020 Jan 17]. Available from: http://hdl.handle.net/1969.1/156990.

Council of Science Editors:

Honang HJ. Reactor Physics Analysis of Air-Cooled Nuclear System. [Masters Thesis]. Texas A&M University; 2016. Available from: http://hdl.handle.net/1969.1/156990


University of Toronto

6. Gray, Jason. A Field Study of Exterior Airtightness Testing in Five Multi-Unit Residential Buildings.

Degree: 2018, University of Toronto

The airtightness of a multi-unit residential building (MURB) enclosure is an important factor when considering energy consumption. There is limited data available on the airtightness… (more)

Subjects/Keywords: Air Leakage; Airtightness; Blower Door; Exterior Airtightness; Multi-Unit Residential Buildings; MURB; 0543

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Gray, J. (2018). A Field Study of Exterior Airtightness Testing in Five Multi-Unit Residential Buildings. (Masters Thesis). University of Toronto. Retrieved from http://hdl.handle.net/1807/91731

Chicago Manual of Style (16th Edition):

Gray, Jason. “A Field Study of Exterior Airtightness Testing in Five Multi-Unit Residential Buildings.” 2018. Masters Thesis, University of Toronto. Accessed January 17, 2020. http://hdl.handle.net/1807/91731.

MLA Handbook (7th Edition):

Gray, Jason. “A Field Study of Exterior Airtightness Testing in Five Multi-Unit Residential Buildings.” 2018. Web. 17 Jan 2020.

Vancouver:

Gray J. A Field Study of Exterior Airtightness Testing in Five Multi-Unit Residential Buildings. [Internet] [Masters thesis]. University of Toronto; 2018. [cited 2020 Jan 17]. Available from: http://hdl.handle.net/1807/91731.

Council of Science Editors:

Gray J. A Field Study of Exterior Airtightness Testing in Five Multi-Unit Residential Buildings. [Masters Thesis]. University of Toronto; 2018. Available from: http://hdl.handle.net/1807/91731


Texas A&M University

7. Young, James Tirtowijoyo. A Compressed Air System Model for Analysis and Design.

Degree: MS, Mechanical Engineering, 2016, Texas A&M University

 The typical efficiency of a compressed air system ranges from 5% to 20%, making it one of the most expensive utilities in industrial plants, hence… (more)

Subjects/Keywords: Compressed air; system; compressor; intercooler; aftercooler; receiver; accumulator; dryer; regulator; piping; leakage; pneumatic; pressure; humidity; matlab; mechanical engineering; hvac

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Young, J. T. (2016). A Compressed Air System Model for Analysis and Design. (Masters Thesis). Texas A&M University. Retrieved from http://hdl.handle.net/1969.1/158119

Chicago Manual of Style (16th Edition):

Young, James Tirtowijoyo. “A Compressed Air System Model for Analysis and Design.” 2016. Masters Thesis, Texas A&M University. Accessed January 17, 2020. http://hdl.handle.net/1969.1/158119.

MLA Handbook (7th Edition):

Young, James Tirtowijoyo. “A Compressed Air System Model for Analysis and Design.” 2016. Web. 17 Jan 2020.

Vancouver:

Young JT. A Compressed Air System Model for Analysis and Design. [Internet] [Masters thesis]. Texas A&M University; 2016. [cited 2020 Jan 17]. Available from: http://hdl.handle.net/1969.1/158119.

Council of Science Editors:

Young JT. A Compressed Air System Model for Analysis and Design. [Masters Thesis]. Texas A&M University; 2016. Available from: http://hdl.handle.net/1969.1/158119


Brno University of Technology

8. Babický, Jan. Využití vzduchu jakožto měřicího media pro detekci netěsností v automobilovém průmyslu .

Degree: 2015, Brno University of Technology

 Bakalářská práce se zabývá vlastnostmi a využitím vzduchu, jakožto měřicího média při detekci a ověřování míry netěsnosti měřené soustavy. Cílem práce je se všeobecně seznámit… (more)

Subjects/Keywords: Tlak; vzduch; míra netěsnosti; hřídelový těsnící kroužek; detekce netěsnosti; Pressure; air; leak; shaft sealing ring; leakage test

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Babický, J. (2015). Využití vzduchu jakožto měřicího media pro detekci netěsností v automobilovém průmyslu . (Thesis). Brno University of Technology. Retrieved from http://hdl.handle.net/11012/39848

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Babický, Jan. “Využití vzduchu jakožto měřicího media pro detekci netěsností v automobilovém průmyslu .” 2015. Thesis, Brno University of Technology. Accessed January 17, 2020. http://hdl.handle.net/11012/39848.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Babický, Jan. “Využití vzduchu jakožto měřicího media pro detekci netěsností v automobilovém průmyslu .” 2015. Web. 17 Jan 2020.

Vancouver:

Babický J. Využití vzduchu jakožto měřicího media pro detekci netěsností v automobilovém průmyslu . [Internet] [Thesis]. Brno University of Technology; 2015. [cited 2020 Jan 17]. Available from: http://hdl.handle.net/11012/39848.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Babický J. Využití vzduchu jakožto měřicího media pro detekci netěsností v automobilovém průmyslu . [Thesis]. Brno University of Technology; 2015. Available from: http://hdl.handle.net/11012/39848

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

9. Matos, Carlos Hugo Caseiro Tavares de Freitas. Aplicação do Ensaio de Porta Ventiladora ao Regulamento das Características de Comportamento Térmico dos Edifícios.

Degree: 2013, Instituto Politécnico do Porto

Com a crescente sensibilização mundial relativa ao aquecimento global, provocado pela alta quantidade de emissão de gases com efeito de estufa, torna-se imperativa a redução… (more)

Subjects/Keywords: Permeabilidade ao ar; Porta ventiladora; Renovações por Hora; Conforto térmico; Air Leakage; Blower Door; Air Changes per Hour; Thermal Comfort; Energy Conservation; Construções

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Matos, C. H. C. T. d. F. (2013). Aplicação do Ensaio de Porta Ventiladora ao Regulamento das Características de Comportamento Térmico dos Edifícios. (Thesis). Instituto Politécnico do Porto. Retrieved from https://www.rcaap.pt/detail.jsp?id=oai:recipp.ipp.pt:10400.22/7588

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Matos, Carlos Hugo Caseiro Tavares de Freitas. “Aplicação do Ensaio de Porta Ventiladora ao Regulamento das Características de Comportamento Térmico dos Edifícios.” 2013. Thesis, Instituto Politécnico do Porto. Accessed January 17, 2020. https://www.rcaap.pt/detail.jsp?id=oai:recipp.ipp.pt:10400.22/7588.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Matos, Carlos Hugo Caseiro Tavares de Freitas. “Aplicação do Ensaio de Porta Ventiladora ao Regulamento das Características de Comportamento Térmico dos Edifícios.” 2013. Web. 17 Jan 2020.

Vancouver:

Matos CHCTdF. Aplicação do Ensaio de Porta Ventiladora ao Regulamento das Características de Comportamento Térmico dos Edifícios. [Internet] [Thesis]. Instituto Politécnico do Porto; 2013. [cited 2020 Jan 17]. Available from: https://www.rcaap.pt/detail.jsp?id=oai:recipp.ipp.pt:10400.22/7588.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Matos CHCTdF. Aplicação do Ensaio de Porta Ventiladora ao Regulamento das Características de Comportamento Térmico dos Edifícios. [Thesis]. Instituto Politécnico do Porto; 2013. Available from: https://www.rcaap.pt/detail.jsp?id=oai:recipp.ipp.pt:10400.22/7588

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Universidade do Rio Grande do Sul

10. Clebsch, Claudia Cristina. Potencial bioindicador de cultivares de feijão (Phaseolus vulgaris L.) para o monitoramento do ozônio troposférico.

Degree: 2008, Universidade do Rio Grande do Sul

 O ozônio troposférico (O3) é um dos poluentes mais importantes da atualidade, sendo formado pela interação de óxidos de nitrogênio, hidrocarbonetos e radiação ultravioleta. Ele… (more)

Subjects/Keywords: Ozônio; Tropospheric ozone; Bioindicadores; Bioindicator air quality; Phaseolus vulgaris; Qualidade do ar; Bhotosynthesis; Phaseolus vulgaris; Câmara de topo-aberto; Relative leakage of electrolytes; Foliar abscission; Biomass; Open-top chambers

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Clebsch, C. C. (2008). Potencial bioindicador de cultivares de feijão (Phaseolus vulgaris L.) para o monitoramento do ozônio troposférico. (Thesis). Universidade do Rio Grande do Sul. Retrieved from http://hdl.handle.net/10183/14357

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Clebsch, Claudia Cristina. “Potencial bioindicador de cultivares de feijão (Phaseolus vulgaris L.) para o monitoramento do ozônio troposférico.” 2008. Thesis, Universidade do Rio Grande do Sul. Accessed January 17, 2020. http://hdl.handle.net/10183/14357.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Clebsch, Claudia Cristina. “Potencial bioindicador de cultivares de feijão (Phaseolus vulgaris L.) para o monitoramento do ozônio troposférico.” 2008. Web. 17 Jan 2020.

Vancouver:

Clebsch CC. Potencial bioindicador de cultivares de feijão (Phaseolus vulgaris L.) para o monitoramento do ozônio troposférico. [Internet] [Thesis]. Universidade do Rio Grande do Sul; 2008. [cited 2020 Jan 17]. Available from: http://hdl.handle.net/10183/14357.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Clebsch CC. Potencial bioindicador de cultivares de feijão (Phaseolus vulgaris L.) para o monitoramento do ozônio troposférico. [Thesis]. Universidade do Rio Grande do Sul; 2008. Available from: http://hdl.handle.net/10183/14357

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

11. Azzam, Tarik. Aérodynamique et contrôle de l'écoulement de jeu dans un ventilateur axial obtenu par rotomoulage. : Aerodynamic and tip clearance flow control of an axial fan obtained with rotational molding.

Degree: Docteur es, Mécanique-matériaux, 2018, Paris, ENSAM; École Militaire Polytechnique (Alger)

Aujourd’hui, la fabrication des turbomachines est conditionnée par des normes de plus en plus restrictives. L'enjeu industriel pour les chercheurs est d'envisager des solutions optimales… (more)

Subjects/Keywords: Ventilateur axial rotomoulé; Contrôle du débit de fuite; Soufflage rotatif; Autorotation; Rotomoleded Axial fan; Leakage flow control; Rotary steady air injection; Autorotation

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Azzam, T. (2018). Aérodynamique et contrôle de l'écoulement de jeu dans un ventilateur axial obtenu par rotomoulage. : Aerodynamic and tip clearance flow control of an axial fan obtained with rotational molding. (Doctoral Dissertation). Paris, ENSAM; École Militaire Polytechnique (Alger). Retrieved from http://www.theses.fr/2018ENAM0080

Chicago Manual of Style (16th Edition):

Azzam, Tarik. “Aérodynamique et contrôle de l'écoulement de jeu dans un ventilateur axial obtenu par rotomoulage. : Aerodynamic and tip clearance flow control of an axial fan obtained with rotational molding.” 2018. Doctoral Dissertation, Paris, ENSAM; École Militaire Polytechnique (Alger). Accessed January 17, 2020. http://www.theses.fr/2018ENAM0080.

MLA Handbook (7th Edition):

Azzam, Tarik. “Aérodynamique et contrôle de l'écoulement de jeu dans un ventilateur axial obtenu par rotomoulage. : Aerodynamic and tip clearance flow control of an axial fan obtained with rotational molding.” 2018. Web. 17 Jan 2020.

Vancouver:

Azzam T. Aérodynamique et contrôle de l'écoulement de jeu dans un ventilateur axial obtenu par rotomoulage. : Aerodynamic and tip clearance flow control of an axial fan obtained with rotational molding. [Internet] [Doctoral dissertation]. Paris, ENSAM; École Militaire Polytechnique (Alger); 2018. [cited 2020 Jan 17]. Available from: http://www.theses.fr/2018ENAM0080.

Council of Science Editors:

Azzam T. Aérodynamique et contrôle de l'écoulement de jeu dans un ventilateur axial obtenu par rotomoulage. : Aerodynamic and tip clearance flow control of an axial fan obtained with rotational molding. [Doctoral Dissertation]. Paris, ENSAM; École Militaire Polytechnique (Alger); 2018. Available from: http://www.theses.fr/2018ENAM0080

12. Pech, Thibault. Etude expérimentale et modélisation d'emballages de produits de santé utilisant des matériaux à changement de phase : Experimental study and modeling of health goods packaging using phase change materials.

Degree: Docteur es, Thermique énergétique, 2016, Lyon

Les emballages thermiques, fabriqués à partir de matériaux isolants et associés à des matériaux à changement de phase, constituent une solution à la problématique de… (more)

Subjects/Keywords: Modélisation; Energétique; Energie; Matériaux; Température; Perméabilité; Chaine du froid; Fuite d'air; Emballage; Modelling; Energetic; Energy; Materials; Temperature; Permeability; Cold chaine; Air leakage; Packing; 536.072

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Pech, T. (2016). Etude expérimentale et modélisation d'emballages de produits de santé utilisant des matériaux à changement de phase : Experimental study and modeling of health goods packaging using phase change materials. (Doctoral Dissertation). Lyon. Retrieved from http://www.theses.fr/2016LYSEI039

Chicago Manual of Style (16th Edition):

Pech, Thibault. “Etude expérimentale et modélisation d'emballages de produits de santé utilisant des matériaux à changement de phase : Experimental study and modeling of health goods packaging using phase change materials.” 2016. Doctoral Dissertation, Lyon. Accessed January 17, 2020. http://www.theses.fr/2016LYSEI039.

MLA Handbook (7th Edition):

Pech, Thibault. “Etude expérimentale et modélisation d'emballages de produits de santé utilisant des matériaux à changement de phase : Experimental study and modeling of health goods packaging using phase change materials.” 2016. Web. 17 Jan 2020.

Vancouver:

Pech T. Etude expérimentale et modélisation d'emballages de produits de santé utilisant des matériaux à changement de phase : Experimental study and modeling of health goods packaging using phase change materials. [Internet] [Doctoral dissertation]. Lyon; 2016. [cited 2020 Jan 17]. Available from: http://www.theses.fr/2016LYSEI039.

Council of Science Editors:

Pech T. Etude expérimentale et modélisation d'emballages de produits de santé utilisant des matériaux à changement de phase : Experimental study and modeling of health goods packaging using phase change materials. [Doctoral Dissertation]. Lyon; 2016. Available from: http://www.theses.fr/2016LYSEI039


Brno University of Technology

13. Kurillová, Katarína. Návrh testovacího zařízení pneumatických aktuátorů .

Degree: 2019, Brno University of Technology

 Táto práca je zameraná na zisťovanie úniku vzduchu v sériovej výrobe pneumatických lineárnych aktuátorov. Testovanie úniku vzduchu je podstatnou kontrolnou časťou výrobného procesu pneumatických valcov,… (more)

Subjects/Keywords: pneumatické aktuátory; únik vzduchu; metódy testovania; prietokomer; pneumatická logika; Bronkhorst; TwinCAT; pneumatic actuators; air leakage; testing methods; flowmeter; pneumatic circuit; Bronkhorst; TwinCAT

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Kurillová, K. (2019). Návrh testovacího zařízení pneumatických aktuátorů . (Thesis). Brno University of Technology. Retrieved from http://hdl.handle.net/11012/179379

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Kurillová, Katarína. “Návrh testovacího zařízení pneumatických aktuátorů .” 2019. Thesis, Brno University of Technology. Accessed January 17, 2020. http://hdl.handle.net/11012/179379.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Kurillová, Katarína. “Návrh testovacího zařízení pneumatických aktuátorů .” 2019. Web. 17 Jan 2020.

Vancouver:

Kurillová K. Návrh testovacího zařízení pneumatických aktuátorů . [Internet] [Thesis]. Brno University of Technology; 2019. [cited 2020 Jan 17]. Available from: http://hdl.handle.net/11012/179379.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Kurillová K. Návrh testovacího zařízení pneumatických aktuátorů . [Thesis]. Brno University of Technology; 2019. Available from: http://hdl.handle.net/11012/179379

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

14. Andersson, Robin. Energibalansberäkning för flerbostadshus : projekterad energianvändning jämfört med beräknad energianvändning med uppmätta värden för Gävle Strand Etapp 1.

Degree: Energy and Environmental Engineering, 2011, University of Gävle

Den beräknad mängd energi en byggnad gör av med på ett år visar huruvida den bidrar till ett hållbart samhälle eller inte. AB Gavlegårdarna… (more)

Subjects/Keywords: BV2; energy; air leakage; apartment buildings; kWh/m2; years; temperature efficiency; Sveby; FTX system; BV2; energianvändning; luftläckage; flerbostadshus; kWh/m2; år; temperaturverkningsgrad; Sveby; FTX-system

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Andersson, R. (2011). Energibalansberäkning för flerbostadshus : projekterad energianvändning jämfört med beräknad energianvändning med uppmätta värden för Gävle Strand Etapp 1. (Thesis). University of Gävle. Retrieved from http://urn.kb.se/resolve?urn=urn:nbn:se:hig:diva-11571

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Andersson, Robin. “Energibalansberäkning för flerbostadshus : projekterad energianvändning jämfört med beräknad energianvändning med uppmätta värden för Gävle Strand Etapp 1.” 2011. Thesis, University of Gävle. Accessed January 17, 2020. http://urn.kb.se/resolve?urn=urn:nbn:se:hig:diva-11571.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Andersson, Robin. “Energibalansberäkning för flerbostadshus : projekterad energianvändning jämfört med beräknad energianvändning med uppmätta värden för Gävle Strand Etapp 1.” 2011. Web. 17 Jan 2020.

Vancouver:

Andersson R. Energibalansberäkning för flerbostadshus : projekterad energianvändning jämfört med beräknad energianvändning med uppmätta värden för Gävle Strand Etapp 1. [Internet] [Thesis]. University of Gävle; 2011. [cited 2020 Jan 17]. Available from: http://urn.kb.se/resolve?urn=urn:nbn:se:hig:diva-11571.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Andersson R. Energibalansberäkning för flerbostadshus : projekterad energianvändning jämfört med beräknad energianvändning med uppmätta värden för Gävle Strand Etapp 1. [Thesis]. University of Gävle; 2011. Available from: http://urn.kb.se/resolve?urn=urn:nbn:se:hig:diva-11571

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

15. Dagson, Josef. Air Leakage Diagnosis in Heavy Duty Truck Engines with EGR and VGT.

Degree: The Institute of Technology, 2009, Linköping UniversityLinköping University

Scania CV AB is a leading company within development and production of buses, trucks as well as industrial and marine engines. New environmental and… (more)

Subjects/Keywords: Diagnosis; model based; structural methods; residual generation; gas; air leakage

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Dagson, J. (2009). Air Leakage Diagnosis in Heavy Duty Truck Engines with EGR and VGT. (Thesis). Linköping UniversityLinköping University. Retrieved from http://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-88183

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Dagson, Josef. “Air Leakage Diagnosis in Heavy Duty Truck Engines with EGR and VGT.” 2009. Thesis, Linköping UniversityLinköping University. Accessed January 17, 2020. http://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-88183.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Dagson, Josef. “Air Leakage Diagnosis in Heavy Duty Truck Engines with EGR and VGT.” 2009. Web. 17 Jan 2020.

Vancouver:

Dagson J. Air Leakage Diagnosis in Heavy Duty Truck Engines with EGR and VGT. [Internet] [Thesis]. Linköping UniversityLinköping University; 2009. [cited 2020 Jan 17]. Available from: http://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-88183.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Dagson J. Air Leakage Diagnosis in Heavy Duty Truck Engines with EGR and VGT. [Thesis]. Linköping UniversityLinköping University; 2009. Available from: http://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-88183

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


KTH

16. Pourfeiz, Hani. Undersökning av TRP tak med PIR isolering utan plastfolie.

Degree: Civil and Architectural Engineering, 2015, KTH

Idag ligger fokus på energieffektivisering av byggnader. I och med detta ligger tung vikt på fuktsäkerhetsprojektering i konstruktioner som i sin tur måste vara… (more)

Subjects/Keywords: WUFI; plastfolie; luftläckage; konvektion; diffusion; PIR- isolering; inomhusluft; ångspärr; lufttäta; fuktsäker.; WUFI; plastic foil; air leakage; diffusion; convection PIR- insulation; indoors; vapor; barrier; airproof; moisture-proof

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Pourfeiz, H. (2015). Undersökning av TRP tak med PIR isolering utan plastfolie. (Thesis). KTH. Retrieved from http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-174353

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Pourfeiz, Hani. “Undersökning av TRP tak med PIR isolering utan plastfolie.” 2015. Thesis, KTH. Accessed January 17, 2020. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-174353.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Pourfeiz, Hani. “Undersökning av TRP tak med PIR isolering utan plastfolie.” 2015. Web. 17 Jan 2020.

Vancouver:

Pourfeiz H. Undersökning av TRP tak med PIR isolering utan plastfolie. [Internet] [Thesis]. KTH; 2015. [cited 2020 Jan 17]. Available from: http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-174353.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Pourfeiz H. Undersökning av TRP tak med PIR isolering utan plastfolie. [Thesis]. KTH; 2015. Available from: http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-174353

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Lund

17. Kronvall, Johnny. Air flows in building components.

Degree: 1980, University of Lund

 This work deals with different aspects of air movements in building components . The investigation shows to what degree the concept of fluid mechanics can… (more)

Subjects/Keywords: Husbyggnad; air flow; air movement; building component; fluctuating pressure; leakage; pressurization; permeability; porosity; surface roughness; entrance; bend; exit pressure loss; pressure drop; infiltration; convection

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Kronvall, J. (1980). Air flows in building components. (Doctoral Dissertation). University of Lund. Retrieved from http://lup.lub.lu.se/record/8056051 ; http://portal.research.lu.se/ws/files/4543703/8056052.pdf

Chicago Manual of Style (16th Edition):

Kronvall, Johnny. “Air flows in building components.” 1980. Doctoral Dissertation, University of Lund. Accessed January 17, 2020. http://lup.lub.lu.se/record/8056051 ; http://portal.research.lu.se/ws/files/4543703/8056052.pdf.

MLA Handbook (7th Edition):

Kronvall, Johnny. “Air flows in building components.” 1980. Web. 17 Jan 2020.

Vancouver:

Kronvall J. Air flows in building components. [Internet] [Doctoral dissertation]. University of Lund; 1980. [cited 2020 Jan 17]. Available from: http://lup.lub.lu.se/record/8056051 ; http://portal.research.lu.se/ws/files/4543703/8056052.pdf.

Council of Science Editors:

Kronvall J. Air flows in building components. [Doctoral Dissertation]. University of Lund; 1980. Available from: http://lup.lub.lu.se/record/8056051 ; http://portal.research.lu.se/ws/files/4543703/8056052.pdf

18. Guðjónsdóttir, Auður. Investigation of leakage contribution from different air seal components.

Degree: Machine Design (Div.), 2019, KTH

Mountain biking is a sport where riders bike on trails, varying in slope and difficulty. Mountain bikes are generally equipped with suspension on the… (more)

Subjects/Keywords: Mountain bike; air spring; air leakage; robust design; seal wear; Terrängcykel; luftfjäder; luftläckage; robust konstruktion; tätningsslitage; Mechanical Engineering; Maskinteknik

…x5B;28].......... 38 Figure 22. An Ishikawa diagram for an MTB rear shock’s air leakage… …minor leakage of air from extended use is considered acceptable and it is a part of standard… …maintenance to pump the shock with air to regain appropriate air pressure. If the air leakage… …Öhlins air shock mounted on a mountain bike. [7] 1.2 Purpose Excessive leakage from… …investigation of the causes of air leakage in MTB air shocks. A shock’s sealing system is studied to… 

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Guðjónsdóttir, A. (2019). Investigation of leakage contribution from different air seal components. (Thesis). KTH. Retrieved from http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-259670

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Guðjónsdóttir, Auður. “Investigation of leakage contribution from different air seal components.” 2019. Thesis, KTH. Accessed January 17, 2020. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-259670.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Guðjónsdóttir, Auður. “Investigation of leakage contribution from different air seal components.” 2019. Web. 17 Jan 2020.

Vancouver:

Guðjónsdóttir A. Investigation of leakage contribution from different air seal components. [Internet] [Thesis]. KTH; 2019. [cited 2020 Jan 17]. Available from: http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-259670.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Guðjónsdóttir A. Investigation of leakage contribution from different air seal components. [Thesis]. KTH; 2019. Available from: http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-259670

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Penn State University

19. McWhirter, Dylan Montgomery. Impact of Return Air System on Indoor Air Quality and Building Security.

Degree: MS, Architectural Engineering, 2011, Penn State University

 The impacts of ducted air distribution system design and performance on buildings, particularly residential structures in which ducts are frequently outside condition space, has received… (more)

Subjects/Keywords: CONTAM; building security; Iowa Energy Center Energy Resource Station; multizone model; fan powered box; plenum return; ducted return; tracer gas test; Indoor air quality; interzonal contaminant transfer; occupant exposure; energy model; duct leakage; contaminant dispersion resistance

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

McWhirter, D. M. (2011). Impact of Return Air System on Indoor Air Quality and Building Security. (Masters Thesis). Penn State University. Retrieved from https://etda.libraries.psu.edu/catalog/11908

Chicago Manual of Style (16th Edition):

McWhirter, Dylan Montgomery. “Impact of Return Air System on Indoor Air Quality and Building Security.” 2011. Masters Thesis, Penn State University. Accessed January 17, 2020. https://etda.libraries.psu.edu/catalog/11908.

MLA Handbook (7th Edition):

McWhirter, Dylan Montgomery. “Impact of Return Air System on Indoor Air Quality and Building Security.” 2011. Web. 17 Jan 2020.

Vancouver:

McWhirter DM. Impact of Return Air System on Indoor Air Quality and Building Security. [Internet] [Masters thesis]. Penn State University; 2011. [cited 2020 Jan 17]. Available from: https://etda.libraries.psu.edu/catalog/11908.

Council of Science Editors:

McWhirter DM. Impact of Return Air System on Indoor Air Quality and Building Security. [Masters Thesis]. Penn State University; 2011. Available from: https://etda.libraries.psu.edu/catalog/11908


North-West University

20. Peens, Gert Petrus. Evaluation of upstream and downstream process parameters on electrostatic precipitator performance / Gert Petrus Peens .

Degree: 2013, North-West University

 New emission legislation regarding air pollution control, as instructed by the Department of Environmental Affairs (DEA) to Eskom Generation Power Stations, implies a particulate emission… (more)

Subjects/Keywords: Air heater leakage; Ash fineness distribution; Coal quality; Deutsch equation; Dust burden; Efficiency; Electrostatic precipitator; Matts-Ohnfeldt equation; Migration velocity; Optimisation; Particulate emission prediction; Performance; Power supply; Simulation model; Volume flow distribution

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Peens, G. P. (2013). Evaluation of upstream and downstream process parameters on electrostatic precipitator performance / Gert Petrus Peens . (Thesis). North-West University. Retrieved from http://hdl.handle.net/10394/11932

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Peens, Gert Petrus. “Evaluation of upstream and downstream process parameters on electrostatic precipitator performance / Gert Petrus Peens .” 2013. Thesis, North-West University. Accessed January 17, 2020. http://hdl.handle.net/10394/11932.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Peens, Gert Petrus. “Evaluation of upstream and downstream process parameters on electrostatic precipitator performance / Gert Petrus Peens .” 2013. Web. 17 Jan 2020.

Vancouver:

Peens GP. Evaluation of upstream and downstream process parameters on electrostatic precipitator performance / Gert Petrus Peens . [Internet] [Thesis]. North-West University; 2013. [cited 2020 Jan 17]. Available from: http://hdl.handle.net/10394/11932.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Peens GP. Evaluation of upstream and downstream process parameters on electrostatic precipitator performance / Gert Petrus Peens . [Thesis]. North-West University; 2013. Available from: http://hdl.handle.net/10394/11932

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Brno University of Technology

21. Jirásek, Tomáš. Výpočet přídavných ztrát asynchronního stroje .

Degree: 2010, Brno University of Technology

 Hlavním cílem práce je určení přídavných ztrát naprázdno v elektrických točivých strojích a výpočet těchto ztrát pro zadaný asynchronní motor. Přídavné ztráty jsou způsobeny především… (more)

Subjects/Keywords: Diferenční rozptyl; magnetická vodivost; magnetické pole; magnetický tok; povrchové ztráty; pulzační ztráty; přídavné ztráty; vzduchová mezera; ztráty klecové kotvy.; Differential leakage; permeance; magnetic field; magnetic flux; surface losses; impulse losses; additional losses; air-gap; cage rotor losses.

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Jirásek, T. (2010). Výpočet přídavných ztrát asynchronního stroje . (Thesis). Brno University of Technology. Retrieved from http://hdl.handle.net/11012/8317

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Jirásek, Tomáš. “Výpočet přídavných ztrát asynchronního stroje .” 2010. Thesis, Brno University of Technology. Accessed January 17, 2020. http://hdl.handle.net/11012/8317.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Jirásek, Tomáš. “Výpočet přídavných ztrát asynchronního stroje .” 2010. Web. 17 Jan 2020.

Vancouver:

Jirásek T. Výpočet přídavných ztrát asynchronního stroje . [Internet] [Thesis]. Brno University of Technology; 2010. [cited 2020 Jan 17]. Available from: http://hdl.handle.net/11012/8317.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Jirásek T. Výpočet přídavných ztrát asynchronního stroje . [Thesis]. Brno University of Technology; 2010. Available from: http://hdl.handle.net/11012/8317

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

22. Trainor, Trevor. The Hygrothermal Performance of Exterior Insulated Wall Systems.

Degree: 2014, University of Waterloo

 As energy certification programs and mandatory governmental building codes demand better building energy performance, the development of durable, highly insulated wall systems has become a… (more)

Subjects/Keywords: Hygrothermal; Wall System; Exterior Insulated; Building Science; Drying Capacity; Wetting Potential; Air Leakage; Condensation

…Percentage of total hours with potential for condensation - air leakage phase… …increased potential for air leakage condensation at the sheathing and 2) decreased ability of… …for most of the winter and air leakage condensation potential will be greatly reduced. By… …with respect to air leakage condensation potential and drying capacity will be discussed… …of the study will be on air leakage condensation potential and the ability of the wall… 

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Trainor, T. (2014). The Hygrothermal Performance of Exterior Insulated Wall Systems. (Thesis). University of Waterloo. Retrieved from http://hdl.handle.net/10012/8550

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Trainor, Trevor. “The Hygrothermal Performance of Exterior Insulated Wall Systems.” 2014. Thesis, University of Waterloo. Accessed January 17, 2020. http://hdl.handle.net/10012/8550.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Trainor, Trevor. “The Hygrothermal Performance of Exterior Insulated Wall Systems.” 2014. Web. 17 Jan 2020.

Vancouver:

Trainor T. The Hygrothermal Performance of Exterior Insulated Wall Systems. [Internet] [Thesis]. University of Waterloo; 2014. [cited 2020 Jan 17]. Available from: http://hdl.handle.net/10012/8550.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Trainor T. The Hygrothermal Performance of Exterior Insulated Wall Systems. [Thesis]. University of Waterloo; 2014. Available from: http://hdl.handle.net/10012/8550

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

23. Younes, Chadi. Developing an Enhanced Model for Combined Heat and Air Infiltration Energy Simulation.

Degree: PhD, Civil Engineering, 2012, Florida International University

  The need for efficient, sustainable, and planned utilization of resources is ever more critical. In the U.S. alone, buildings consume 34.8 Quadrillion (1015) BTU… (more)

Subjects/Keywords: Infiltration; CFD; Multiphysics; Hygrothermal; DOE-2; Building Energy; Air Leakage; HVAC; Sustainability

…132 Air Leakage Cracks & Paths… …113 Figure 3-10: Effective air leakage are, ASHRAE Handbook Chapter 25 Table 1 (… …142 Figure 3-20: Air Leakage By County (Sherman and McWilliams, 2007)… …203 Figure 5-7: Vortex Plot Revealing Air Leakage Across In-wall Caracks (1)… …134 xvii LIST OF CHARTS CHART PAGE Chart 2-1: Air Leakage Rates of Elevator Shaft Walls… 

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Younes, C. (2012). Developing an Enhanced Model for Combined Heat and Air Infiltration Energy Simulation. (Doctoral Dissertation). Florida International University. Retrieved from https://digitalcommons.fiu.edu/etd/743 ; 10.25148/etd.FI12112705 ; FI12112705

Chicago Manual of Style (16th Edition):

Younes, Chadi. “Developing an Enhanced Model for Combined Heat and Air Infiltration Energy Simulation.” 2012. Doctoral Dissertation, Florida International University. Accessed January 17, 2020. https://digitalcommons.fiu.edu/etd/743 ; 10.25148/etd.FI12112705 ; FI12112705.

MLA Handbook (7th Edition):

Younes, Chadi. “Developing an Enhanced Model for Combined Heat and Air Infiltration Energy Simulation.” 2012. Web. 17 Jan 2020.

Vancouver:

Younes C. Developing an Enhanced Model for Combined Heat and Air Infiltration Energy Simulation. [Internet] [Doctoral dissertation]. Florida International University; 2012. [cited 2020 Jan 17]. Available from: https://digitalcommons.fiu.edu/etd/743 ; 10.25148/etd.FI12112705 ; FI12112705.

Council of Science Editors:

Younes C. Developing an Enhanced Model for Combined Heat and Air Infiltration Energy Simulation. [Doctoral Dissertation]. Florida International University; 2012. Available from: https://digitalcommons.fiu.edu/etd/743 ; 10.25148/etd.FI12112705 ; FI12112705


University of Queensland

24. Zheng, Chun-shan. Effects of coal mining on multi-seam gas drainage borehole layout and sealing: implementation of the coupled permeability model.

Degree: School of Mechanical and Mining Engineering, 2018, University of Queensland

Subjects/Keywords: Multi-seam gas drainage; Coal seam interaction; Coupled permeability model; Underground to inseam borehole; Ventilation air leakage; Mechanics-flow coupling; Weibull statistical distribution; FEM numerical modelling; Borehole layout; 0403 Geology; 0914 Resources Engineering and Extractive Metallurgy

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Zheng, C. (2018). Effects of coal mining on multi-seam gas drainage borehole layout and sealing: implementation of the coupled permeability model. (Thesis). University of Queensland. Retrieved from https://espace.library.uq.edu.au/view/UQ:ab93a4a/s4360140_final_thesis.pdf ; https://espace.library.uq.edu.au/view/UQ:ab93a4a

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Zheng, Chun-shan. “Effects of coal mining on multi-seam gas drainage borehole layout and sealing: implementation of the coupled permeability model.” 2018. Thesis, University of Queensland. Accessed January 17, 2020. https://espace.library.uq.edu.au/view/UQ:ab93a4a/s4360140_final_thesis.pdf ; https://espace.library.uq.edu.au/view/UQ:ab93a4a.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Zheng, Chun-shan. “Effects of coal mining on multi-seam gas drainage borehole layout and sealing: implementation of the coupled permeability model.” 2018. Web. 17 Jan 2020.

Vancouver:

Zheng C. Effects of coal mining on multi-seam gas drainage borehole layout and sealing: implementation of the coupled permeability model. [Internet] [Thesis]. University of Queensland; 2018. [cited 2020 Jan 17]. Available from: https://espace.library.uq.edu.au/view/UQ:ab93a4a/s4360140_final_thesis.pdf ; https://espace.library.uq.edu.au/view/UQ:ab93a4a.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Zheng C. Effects of coal mining on multi-seam gas drainage borehole layout and sealing: implementation of the coupled permeability model. [Thesis]. University of Queensland; 2018. Available from: https://espace.library.uq.edu.au/view/UQ:ab93a4a/s4360140_final_thesis.pdf ; https://espace.library.uq.edu.au/view/UQ:ab93a4a

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

25. ΚΟΚΚΙΝΑΚΗΣ, ΕΜΜΑΝΟΥΗΛ. INTERACTION BETWEEN GEL STRENGTH AND YEAST CELLS IMMOBILIZED IN CALCIUM ALGINATE GEL.

Degree: 1994, Ιδρύματα Εξωτερικού; Institutes outside Greece

ΣΚΟΠΟΣ ΤΗΣ ΕΡΓΑΣΙΑΣ ΕΙΝΑΙ Η ΒΕΛΤΙΩΣΗ ΤΗΣ ΑΝΘΕΚΤΙΚΟΤΗΤΑΣ ΤΗΣ ΓΕΛΗΣ (ΚΟΛΛΟΕΙΔΟΥΣ ΠΗΓΜΑΤΟΣ) CALCIUM ALGINATE GEL ΩΣ ΜΙΑΣ ΑΚΙΝΗΤΟΠΟΙΟΥΣΑΣ ΡΙΖΑΣ ΤΗΣ ΖΥΜΗΣ ΣΕ ΑΕΡΟΒΙΟ ΚΑΛΛΙΕΡΓΕΙΑ, ΔΙΑ… (more)

Subjects/Keywords: AIR LIFT BIOREACTOR - BATCH FERMENTER; CELL MASS LEAKAGE RATE FROM THE GEL; CHEMICALLY DEFINED LIQUID CULTURE MEDIUM; DIFFUSIVITY OF GLUCOSE IN THE GEL MATRIX SOLID PHASE; GLUCOSE UPTAKE BY ACTIVE TRANSPORT IN THE YEAST; IMMOBILIZATION OF YEAST CELLS IN CALCIUM ALGINATE GEL; INTERACTION BETWEEN GEL MATRIX AND IMMOBILIZED CELLS; KINETIC STATE OF IMMOBILIZED CELLS - BIOMASS HOLDUP; ΑΕΡΟΑΝΥΨΩΤΙΚΟΣ ΒΙΟΑΝΤΙΔΡΑΣΤΗΡΑΣ; ΑΚΙΝΗΤΟΠΟΙΗΣΗ ΖΥΜΟΚΥΤΤΑΡΩΝ ΣΕ CALCIUM ALGINATE GEL; ΑΛΛΗΛΕΠΙΔΡΑΣΗ ΓΕΛΟΜΗΤΡΑΣ ΚΑΙΑΚΙΝΗΤΟΠΟΙΟΥΜΕΝΩΝ ΚΥΤΤΑΡΩΝ; ΑΠΟΡΡΟΦΗΣΗΓΛΥΚΟΖΗΣ ΜΕ ΕΝΕΡΓΟΜΕΤΑΦΟΡΑ ΣΤΗ ΖΥΜΗ; ΔΙΑΧΥΤΙΚΟΤΗΤΑ ΓΛΥΚΟΖΗΣ ΣΤΗ ΣΤΕΡΕΑ ΦΑΣΗ ΓΕΛΟΜΗΤΡΑΣ; ΚΙΝΗΤΙΚΗ ΚΑΤΑΣΤΑΣΗ ΑΚΙΝΗΤΟΠΟΙΗΜΕΝΩΝ ΚΥΤΤΑΡΩΝ; ΡΥΘΜΟΣ ΔΙΑΡΡΟΗΣ ΚΥΤΤΑΡΟΜΑΖΑΣ ΑΠΟ ΤΗ ΓΕΛΗ; ΧΗΜΙΚΩΣ ΚΑΘΟΡΙΖΟΜΕΝΟ ΜΕΣΟ ΥΓΡΟΚΑΛΛΙΕΡΓΕΙΑΣ

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

ΚΟΚΚΙΝΑΚΗΣ, . (1994). INTERACTION BETWEEN GEL STRENGTH AND YEAST CELLS IMMOBILIZED IN CALCIUM ALGINATE GEL. (Thesis). Ιδρύματα Εξωτερικού; Institutes outside Greece. Retrieved from http://hdl.handle.net/10442/hedi/7908

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

ΚΟΚΚΙΝΑΚΗΣ, ΕΜΜΑΝΟΥΗΛ. “INTERACTION BETWEEN GEL STRENGTH AND YEAST CELLS IMMOBILIZED IN CALCIUM ALGINATE GEL.” 1994. Thesis, Ιδρύματα Εξωτερικού; Institutes outside Greece. Accessed January 17, 2020. http://hdl.handle.net/10442/hedi/7908.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

ΚΟΚΚΙΝΑΚΗΣ, ΕΜΜΑΝΟΥΗΛ. “INTERACTION BETWEEN GEL STRENGTH AND YEAST CELLS IMMOBILIZED IN CALCIUM ALGINATE GEL.” 1994. Web. 17 Jan 2020.

Vancouver:

ΚΟΚΚΙΝΑΚΗΣ . INTERACTION BETWEEN GEL STRENGTH AND YEAST CELLS IMMOBILIZED IN CALCIUM ALGINATE GEL. [Internet] [Thesis]. Ιδρύματα Εξωτερικού; Institutes outside Greece; 1994. [cited 2020 Jan 17]. Available from: http://hdl.handle.net/10442/hedi/7908.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

ΚΟΚΚΙΝΑΚΗΣ . INTERACTION BETWEEN GEL STRENGTH AND YEAST CELLS IMMOBILIZED IN CALCIUM ALGINATE GEL. [Thesis]. Ιδρύματα Εξωτερικού; Institutes outside Greece; 1994. Available from: http://hdl.handle.net/10442/hedi/7908

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

.