Advanced search options

Advanced Search Options 🞨

Browse by author name (“Author name starts with…”).

Find ETDs with:

in
/  
in
/  
in
/  
in

Written in Published in Earliest date Latest date

Sorted by

Results per page:

Sorted by: relevance · author · university · dateNew search

Dates: 2010 – 2014

You searched for subject:( heat pumps). Showing records 1 – 30 of 92 total matches.

[1] [2] [3] [4]

Search Limiters

Last 2 Years | English Only

Levels

Languages

Country

▼ Search Limiters


University of Johannesburg

1. De Swardt, Christiaan Alexander. A performance comparison between an air-source and a ground-source reversible heat pump.

Degree: 2011, University of Johannesburg

M.Ing.

In this study the performance of a reversible ground-source heat pump, coupled to a municipal water reticulation system, is compared experimentally and with simulations… (more)

Subjects/Keywords: Heat pumps

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

De Swardt, C. A. (2011). A performance comparison between an air-source and a ground-source reversible heat pump. (Thesis). University of Johannesburg. Retrieved from http://hdl.handle.net/10210/4072

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

De Swardt, Christiaan Alexander. “A performance comparison between an air-source and a ground-source reversible heat pump.” 2011. Thesis, University of Johannesburg. Accessed July 17, 2019. http://hdl.handle.net/10210/4072.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

De Swardt, Christiaan Alexander. “A performance comparison between an air-source and a ground-source reversible heat pump.” 2011. Web. 17 Jul 2019.

Vancouver:

De Swardt CA. A performance comparison between an air-source and a ground-source reversible heat pump. [Internet] [Thesis]. University of Johannesburg; 2011. [cited 2019 Jul 17]. Available from: http://hdl.handle.net/10210/4072.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

De Swardt CA. A performance comparison between an air-source and a ground-source reversible heat pump. [Thesis]. University of Johannesburg; 2011. Available from: http://hdl.handle.net/10210/4072

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Hong Kong University of Science and Technology

2. Guan, Xiwen. Formulation and performance of refrigerants for moderately high temperature heat pump.

Degree: 2014, Hong Kong University of Science and Technology

 From household refrigerators and air conditioners to cooling chambers and heat pumps, refrigerants are widely used in both domestic and industrial equipments. Most of the… (more)

Subjects/Keywords: Refrigerants; Heat pumps

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Guan, X. (2014). Formulation and performance of refrigerants for moderately high temperature heat pump. (Thesis). Hong Kong University of Science and Technology. Retrieved from https://doi.org/10.14711/thesis-b1333516 ; http://repository.ust.hk/ir/bitstream/1783.1-70832/1/th_redirect.html

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Guan, Xiwen. “Formulation and performance of refrigerants for moderately high temperature heat pump.” 2014. Thesis, Hong Kong University of Science and Technology. Accessed July 17, 2019. https://doi.org/10.14711/thesis-b1333516 ; http://repository.ust.hk/ir/bitstream/1783.1-70832/1/th_redirect.html.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Guan, Xiwen. “Formulation and performance of refrigerants for moderately high temperature heat pump.” 2014. Web. 17 Jul 2019.

Vancouver:

Guan X. Formulation and performance of refrigerants for moderately high temperature heat pump. [Internet] [Thesis]. Hong Kong University of Science and Technology; 2014. [cited 2019 Jul 17]. Available from: https://doi.org/10.14711/thesis-b1333516 ; http://repository.ust.hk/ir/bitstream/1783.1-70832/1/th_redirect.html.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Guan X. Formulation and performance of refrigerants for moderately high temperature heat pump. [Thesis]. Hong Kong University of Science and Technology; 2014. Available from: https://doi.org/10.14711/thesis-b1333516 ; http://repository.ust.hk/ir/bitstream/1783.1-70832/1/th_redirect.html

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Johannesburg

3. Vorster, Paul Philip Jacobus. Wet compression versus dry compression in heat pumps working with pure refrigerants or non-azeotropic mixtures for different heating applications.

Degree: 2012, University of Johannesburg

M.Ing.

Wet compression versus dry compression in heat pumps working with pure refrigerants or nonazeotropic mixtures is investigated in this paper. In total 34 pure… (more)

Subjects/Keywords: Heat pumps; Refrigerants

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Vorster, P. P. J. (2012). Wet compression versus dry compression in heat pumps working with pure refrigerants or non-azeotropic mixtures for different heating applications. (Thesis). University of Johannesburg. Retrieved from http://hdl.handle.net/10210/7627

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Vorster, Paul Philip Jacobus. “Wet compression versus dry compression in heat pumps working with pure refrigerants or non-azeotropic mixtures for different heating applications.” 2012. Thesis, University of Johannesburg. Accessed July 17, 2019. http://hdl.handle.net/10210/7627.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Vorster, Paul Philip Jacobus. “Wet compression versus dry compression in heat pumps working with pure refrigerants or non-azeotropic mixtures for different heating applications.” 2012. Web. 17 Jul 2019.

Vancouver:

Vorster PPJ. Wet compression versus dry compression in heat pumps working with pure refrigerants or non-azeotropic mixtures for different heating applications. [Internet] [Thesis]. University of Johannesburg; 2012. [cited 2019 Jul 17]. Available from: http://hdl.handle.net/10210/7627.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Vorster PPJ. Wet compression versus dry compression in heat pumps working with pure refrigerants or non-azeotropic mixtures for different heating applications. [Thesis]. University of Johannesburg; 2012. Available from: http://hdl.handle.net/10210/7627

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Johannesburg

4. Oerder, Stacy-Ann. The performance of a municipality water reticulation ground-coupled reversible heat pump.

Degree: 2014, University of Johannesburg

M.Ing. (Mechanical Engineering)

A reversible ground source heat pump, coupled to a municipality water reticulation system, is investigated as an alternative to conventional air source… (more)

Subjects/Keywords: Heat pumps; Air conditioning; Heat exchangers

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Oerder, S. (2014). The performance of a municipality water reticulation ground-coupled reversible heat pump. (Thesis). University of Johannesburg. Retrieved from http://hdl.handle.net/10210/9108

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Oerder, Stacy-Ann. “The performance of a municipality water reticulation ground-coupled reversible heat pump.” 2014. Thesis, University of Johannesburg. Accessed July 17, 2019. http://hdl.handle.net/10210/9108.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Oerder, Stacy-Ann. “The performance of a municipality water reticulation ground-coupled reversible heat pump.” 2014. Web. 17 Jul 2019.

Vancouver:

Oerder S. The performance of a municipality water reticulation ground-coupled reversible heat pump. [Internet] [Thesis]. University of Johannesburg; 2014. [cited 2019 Jul 17]. Available from: http://hdl.handle.net/10210/9108.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Oerder S. The performance of a municipality water reticulation ground-coupled reversible heat pump. [Thesis]. University of Johannesburg; 2014. Available from: http://hdl.handle.net/10210/9108

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Johannesburg

5. Smit, Floris Jakobus. The influence of a non-azeotropic refrigerant mixture on the performance of a hot water heat pump.

Degree: 2012, University of Johannesburg

M.Ing.

The refrigerant R22, which is currently used in hot water heat pumps, delivers a maximum hot water temperature of 60 to 65 °C. This… (more)

Subjects/Keywords: Refrigerants.; Heat pumps.; Hot-water supply.

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Smit, F. J. (2012). The influence of a non-azeotropic refrigerant mixture on the performance of a hot water heat pump. (Thesis). University of Johannesburg. Retrieved from http://hdl.handle.net/10210/6802

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Smit, Floris Jakobus. “The influence of a non-azeotropic refrigerant mixture on the performance of a hot water heat pump.” 2012. Thesis, University of Johannesburg. Accessed July 17, 2019. http://hdl.handle.net/10210/6802.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Smit, Floris Jakobus. “The influence of a non-azeotropic refrigerant mixture on the performance of a hot water heat pump.” 2012. Web. 17 Jul 2019.

Vancouver:

Smit FJ. The influence of a non-azeotropic refrigerant mixture on the performance of a hot water heat pump. [Internet] [Thesis]. University of Johannesburg; 2012. [cited 2019 Jul 17]. Available from: http://hdl.handle.net/10210/6802.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Smit FJ. The influence of a non-azeotropic refrigerant mixture on the performance of a hot water heat pump. [Thesis]. University of Johannesburg; 2012. Available from: http://hdl.handle.net/10210/6802

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Ryerson University

6. Alzahrani, Waleed, S. Experimental study of the performance of a vertical and a horizontal ground loops coupled to a ground source heat pump system:.

Degree: 2014, Ryerson University

 The performance of vertical and horizontal ground loops coupled to a Ground-Source Heat Pump (GSHP) was investigated under four different scenarios. For this purpose, an… (more)

Subjects/Keywords: Heat pumps  – Efficiency; Heat pumps  – Efficiency – -; Ground source heat pump systems; Ground source heat pump systems – -

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Alzahrani, Waleed, S. (2014). Experimental study of the performance of a vertical and a horizontal ground loops coupled to a ground source heat pump system:. (Thesis). Ryerson University. Retrieved from https://digital.library.ryerson.ca/islandora/object/RULA%3A2613

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Alzahrani, Waleed, S. “Experimental study of the performance of a vertical and a horizontal ground loops coupled to a ground source heat pump system:.” 2014. Thesis, Ryerson University. Accessed July 17, 2019. https://digital.library.ryerson.ca/islandora/object/RULA%3A2613.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Alzahrani, Waleed, S. “Experimental study of the performance of a vertical and a horizontal ground loops coupled to a ground source heat pump system:.” 2014. Web. 17 Jul 2019.

Vancouver:

Alzahrani, Waleed S. Experimental study of the performance of a vertical and a horizontal ground loops coupled to a ground source heat pump system:. [Internet] [Thesis]. Ryerson University; 2014. [cited 2019 Jul 17]. Available from: https://digital.library.ryerson.ca/islandora/object/RULA%3A2613.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Alzahrani, Waleed S. Experimental study of the performance of a vertical and a horizontal ground loops coupled to a ground source heat pump system:. [Thesis]. Ryerson University; 2014. Available from: https://digital.library.ryerson.ca/islandora/object/RULA%3A2613

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Brunel University

7. Pouloupatis, Panayiotis. Determination of the thermal characteristic of the ground in Cyprus and their effect on ground heat exchangers.

Degree: PhD, 2014, Brunel University

 Since the ancient years, human beings were using holes and caves to protect themselves from weather conditions making it the first known form of exploiting… (more)

Subjects/Keywords: 621.402; Geothermal; Ground coupled heat pumps; Borehole heat exchangers

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Pouloupatis, P. (2014). Determination of the thermal characteristic of the ground in Cyprus and their effect on ground heat exchangers. (Doctoral Dissertation). Brunel University. Retrieved from http://bura.brunel.ac.uk/handle/2438/10982 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.649394

Chicago Manual of Style (16th Edition):

Pouloupatis, Panayiotis. “Determination of the thermal characteristic of the ground in Cyprus and their effect on ground heat exchangers.” 2014. Doctoral Dissertation, Brunel University. Accessed July 17, 2019. http://bura.brunel.ac.uk/handle/2438/10982 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.649394.

MLA Handbook (7th Edition):

Pouloupatis, Panayiotis. “Determination of the thermal characteristic of the ground in Cyprus and their effect on ground heat exchangers.” 2014. Web. 17 Jul 2019.

Vancouver:

Pouloupatis P. Determination of the thermal characteristic of the ground in Cyprus and their effect on ground heat exchangers. [Internet] [Doctoral dissertation]. Brunel University; 2014. [cited 2019 Jul 17]. Available from: http://bura.brunel.ac.uk/handle/2438/10982 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.649394.

Council of Science Editors:

Pouloupatis P. Determination of the thermal characteristic of the ground in Cyprus and their effect on ground heat exchangers. [Doctoral Dissertation]. Brunel University; 2014. Available from: http://bura.brunel.ac.uk/handle/2438/10982 ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.649394


Ryerson University

8. Safa, Amir Alizadeh. Performance analysis of a two-stage variable capacity air source heat pump and a horizontal loop coupled ground source heat pump system.

Degree: 2012, Ryerson University

 The thermal performance of a new two-stage variable capacity air source heat pump (ASHP) and a horizontal ground loop ground source heat pump (GSHP) was… (more)

Subjects/Keywords: Heat pumps; Ground source heat pump systems; Dwellings  – Heating and ventilation

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Safa, A. A. (2012). Performance analysis of a two-stage variable capacity air source heat pump and a horizontal loop coupled ground source heat pump system. (Thesis). Ryerson University. Retrieved from https://digital.library.ryerson.ca/islandora/object/RULA%3A1281

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Safa, Amir Alizadeh. “Performance analysis of a two-stage variable capacity air source heat pump and a horizontal loop coupled ground source heat pump system.” 2012. Thesis, Ryerson University. Accessed July 17, 2019. https://digital.library.ryerson.ca/islandora/object/RULA%3A1281.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Safa, Amir Alizadeh. “Performance analysis of a two-stage variable capacity air source heat pump and a horizontal loop coupled ground source heat pump system.” 2012. Web. 17 Jul 2019.

Vancouver:

Safa AA. Performance analysis of a two-stage variable capacity air source heat pump and a horizontal loop coupled ground source heat pump system. [Internet] [Thesis]. Ryerson University; 2012. [cited 2019 Jul 17]. Available from: https://digital.library.ryerson.ca/islandora/object/RULA%3A1281.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Safa AA. Performance analysis of a two-stage variable capacity air source heat pump and a horizontal loop coupled ground source heat pump system. [Thesis]. Ryerson University; 2012. Available from: https://digital.library.ryerson.ca/islandora/object/RULA%3A1281

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Massey University

9. Arunwattana, Weerawoot. A model for improvement of water heating heat exchanger designs for residential heat pump water heaters.

Degree: M. Eng., 2010, Massey University

Heat pump water heaters are a promising technology to reduce energy use and greenhouse gas emissions. A key component is the water heating heat exchanger.… (more)

Subjects/Keywords: Heat exchanger design; Heat pumps; Water heaters; Energy consumption

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Arunwattana, W. (2010). A model for improvement of water heating heat exchanger designs for residential heat pump water heaters. (Masters Thesis). Massey University. Retrieved from http://hdl.handle.net/10179/2787

Chicago Manual of Style (16th Edition):

Arunwattana, Weerawoot. “A model for improvement of water heating heat exchanger designs for residential heat pump water heaters.” 2010. Masters Thesis, Massey University. Accessed July 17, 2019. http://hdl.handle.net/10179/2787.

MLA Handbook (7th Edition):

Arunwattana, Weerawoot. “A model for improvement of water heating heat exchanger designs for residential heat pump water heaters.” 2010. Web. 17 Jul 2019.

Vancouver:

Arunwattana W. A model for improvement of water heating heat exchanger designs for residential heat pump water heaters. [Internet] [Masters thesis]. Massey University; 2010. [cited 2019 Jul 17]. Available from: http://hdl.handle.net/10179/2787.

Council of Science Editors:

Arunwattana W. A model for improvement of water heating heat exchanger designs for residential heat pump water heaters. [Masters Thesis]. Massey University; 2010. Available from: http://hdl.handle.net/10179/2787


KTH

10. Gonzalez, Jesus Angel Perez. Understanding numerically generated g-functions: A study case for a 6x6 borehole field.

Degree: Applied Thermodynamics and Refrigeration, 2013, KTH

  The Ground Source Heat Pump systems (GSHP) are an emerging technology used to exchange heat with the ground through the use of some buried… (more)

Subjects/Keywords: borehole; heat exchangers; g-function; ground source heat pumps

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Gonzalez, J. A. P. (2013). Understanding numerically generated g-functions: A study case for a 6x6 borehole field. (Thesis). KTH. Retrieved from http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-126017

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Gonzalez, Jesus Angel Perez. “Understanding numerically generated g-functions: A study case for a 6x6 borehole field.” 2013. Thesis, KTH. Accessed July 17, 2019. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-126017.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Gonzalez, Jesus Angel Perez. “Understanding numerically generated g-functions: A study case for a 6x6 borehole field.” 2013. Web. 17 Jul 2019.

Vancouver:

Gonzalez JAP. Understanding numerically generated g-functions: A study case for a 6x6 borehole field. [Internet] [Thesis]. KTH; 2013. [cited 2019 Jul 17]. Available from: http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-126017.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Gonzalez JAP. Understanding numerically generated g-functions: A study case for a 6x6 borehole field. [Thesis]. KTH; 2013. Available from: http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-126017

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Oklahoma State University

11. Hansen, Garrett Michael. Experimental Measurement and Analysis of Surface Water Heat Exchangers.

Degree: Mechanical & Aerospace Engineering, 2011, Oklahoma State University

 When looking at the heat exchanger of a surface water heat pump (SWHP) system the material of choice these days is high density polyethylene (HDPE).… (more)

Subjects/Keywords: heat exchangers; heat pumps; swhp systems; thermal systems

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Hansen, G. M. (2011). Experimental Measurement and Analysis of Surface Water Heat Exchangers. (Thesis). Oklahoma State University. Retrieved from http://hdl.handle.net/11244/9941

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Hansen, Garrett Michael. “Experimental Measurement and Analysis of Surface Water Heat Exchangers.” 2011. Thesis, Oklahoma State University. Accessed July 17, 2019. http://hdl.handle.net/11244/9941.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Hansen, Garrett Michael. “Experimental Measurement and Analysis of Surface Water Heat Exchangers.” 2011. Web. 17 Jul 2019.

Vancouver:

Hansen GM. Experimental Measurement and Analysis of Surface Water Heat Exchangers. [Internet] [Thesis]. Oklahoma State University; 2011. [cited 2019 Jul 17]. Available from: http://hdl.handle.net/11244/9941.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Hansen GM. Experimental Measurement and Analysis of Surface Water Heat Exchangers. [Thesis]. Oklahoma State University; 2011. Available from: http://hdl.handle.net/11244/9941

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Waterloo

12. Haslam, Simon R. Informing the practice of ground heat exchanger design through numerical simulations.

Degree: 2013, University of Waterloo

 Closed-loop ground source heat pumps (GSHPs) are used to transfer thermal energy between the subsurface and conditioned spaces for heating and cooling applications. A basic… (more)

Subjects/Keywords: geothermal; heat exhanger; finite difference; ground source heat pumps; numerical model

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Haslam, S. R. (2013). Informing the practice of ground heat exchanger design through numerical simulations. (Thesis). University of Waterloo. Retrieved from http://hdl.handle.net/10012/7368

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Haslam, Simon R. “Informing the practice of ground heat exchanger design through numerical simulations.” 2013. Thesis, University of Waterloo. Accessed July 17, 2019. http://hdl.handle.net/10012/7368.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Haslam, Simon R. “Informing the practice of ground heat exchanger design through numerical simulations.” 2013. Web. 17 Jul 2019.

Vancouver:

Haslam SR. Informing the practice of ground heat exchanger design through numerical simulations. [Internet] [Thesis]. University of Waterloo; 2013. [cited 2019 Jul 17]. Available from: http://hdl.handle.net/10012/7368.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Haslam SR. Informing the practice of ground heat exchanger design through numerical simulations. [Thesis]. University of Waterloo; 2013. Available from: http://hdl.handle.net/10012/7368

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Johannesburg

13. Van der Hoek, Leon. Data acquisition system for determining heat transfer coefficients in a heat pump.

Degree: 2012, University of Johannesburg

M.Ing.

Heat pump water heaters (HPWHs) have been identified as a viable replacement for electrical resistance heaters due to their high efficiency and reliability. Heat(more)

Subjects/Keywords: Heat - Transmission - Data processing.; Nusselt number.; Heat pumps.

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Van der Hoek, L. (2012). Data acquisition system for determining heat transfer coefficients in a heat pump. (Thesis). University of Johannesburg. Retrieved from http://hdl.handle.net/10210/6216

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Van der Hoek, Leon. “Data acquisition system for determining heat transfer coefficients in a heat pump.” 2012. Thesis, University of Johannesburg. Accessed July 17, 2019. http://hdl.handle.net/10210/6216.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Van der Hoek, Leon. “Data acquisition system for determining heat transfer coefficients in a heat pump.” 2012. Web. 17 Jul 2019.

Vancouver:

Van der Hoek L. Data acquisition system for determining heat transfer coefficients in a heat pump. [Internet] [Thesis]. University of Johannesburg; 2012. [cited 2019 Jul 17]. Available from: http://hdl.handle.net/10210/6216.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Van der Hoek L. Data acquisition system for determining heat transfer coefficients in a heat pump. [Thesis]. University of Johannesburg; 2012. Available from: http://hdl.handle.net/10210/6216

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Brno University of Technology

14. Lančarič, Vít. Tepelná čerpadla pro rodinný dům .

Degree: 2011, Brno University of Technology

 V tejto bakalárskej práci som sa venoval opisu princípu tepelných čerpadiel a ich rozdeleniu z hľadiska využívania nízkopotencionálneho tepla. Ďalej som si vybral konkrétny daný… (more)

Subjects/Keywords: Tepelné čerpadlá; nízkopotencionálne teplo; Heat pumps; low-potencional´s heat

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Lančarič, V. (2011). Tepelná čerpadla pro rodinný dům . (Thesis). Brno University of Technology. Retrieved from http://hdl.handle.net/11012/5407

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Lančarič, Vít. “Tepelná čerpadla pro rodinný dům .” 2011. Thesis, Brno University of Technology. Accessed July 17, 2019. http://hdl.handle.net/11012/5407.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Lančarič, Vít. “Tepelná čerpadla pro rodinný dům .” 2011. Web. 17 Jul 2019.

Vancouver:

Lančarič V. Tepelná čerpadla pro rodinný dům . [Internet] [Thesis]. Brno University of Technology; 2011. [cited 2019 Jul 17]. Available from: http://hdl.handle.net/11012/5407.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Lančarič V. Tepelná čerpadla pro rodinný dům . [Thesis]. Brno University of Technology; 2011. Available from: http://hdl.handle.net/11012/5407

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Georgia Tech

15. Kim, Sarah Sungeun. An absorption refrigeration system using ionic liquid and hydrofluorocarbon working fluids.

Degree: PhD, Chemical and Biomolecular Engineering, 2013, Georgia Tech

 Efficient heat management in energy intensive applications such as server and data centers has become a national concern due to the magnitude of the energy… (more)

Subjects/Keywords: Absorption refrigeration; Ionic liquid; Heat pump; Heat pumps; Absorption; Waste heat; Ionic solutions

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Kim, S. S. (2013). An absorption refrigeration system using ionic liquid and hydrofluorocarbon working fluids. (Doctoral Dissertation). Georgia Tech. Retrieved from http://hdl.handle.net/1853/51783

Chicago Manual of Style (16th Edition):

Kim, Sarah Sungeun. “An absorption refrigeration system using ionic liquid and hydrofluorocarbon working fluids.” 2013. Doctoral Dissertation, Georgia Tech. Accessed July 17, 2019. http://hdl.handle.net/1853/51783.

MLA Handbook (7th Edition):

Kim, Sarah Sungeun. “An absorption refrigeration system using ionic liquid and hydrofluorocarbon working fluids.” 2013. Web. 17 Jul 2019.

Vancouver:

Kim SS. An absorption refrigeration system using ionic liquid and hydrofluorocarbon working fluids. [Internet] [Doctoral dissertation]. Georgia Tech; 2013. [cited 2019 Jul 17]. Available from: http://hdl.handle.net/1853/51783.

Council of Science Editors:

Kim SS. An absorption refrigeration system using ionic liquid and hydrofluorocarbon working fluids. [Doctoral Dissertation]. Georgia Tech; 2013. Available from: http://hdl.handle.net/1853/51783


University of Minnesota

16. Meester, Jennifer. Optimizing borehole Heat exchanger spacing to maximize advective heat transfer.

Degree: MS, Water Resources Science, 2013, University of Minnesota

 This generalized study provides first order insights into the effect of heat advection on ground source heat pump (GSHP) system operation and the optimization of… (more)

Subjects/Keywords: Computer Simulations; Geothermal; Ground Source Heat Pumps; Heat Exchangers; Heat Transfer; Hydrogeology

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Meester, J. (2013). Optimizing borehole Heat exchanger spacing to maximize advective heat transfer. (Masters Thesis). University of Minnesota. Retrieved from http://hdl.handle.net/11299/162371

Chicago Manual of Style (16th Edition):

Meester, Jennifer. “Optimizing borehole Heat exchanger spacing to maximize advective heat transfer.” 2013. Masters Thesis, University of Minnesota. Accessed July 17, 2019. http://hdl.handle.net/11299/162371.

MLA Handbook (7th Edition):

Meester, Jennifer. “Optimizing borehole Heat exchanger spacing to maximize advective heat transfer.” 2013. Web. 17 Jul 2019.

Vancouver:

Meester J. Optimizing borehole Heat exchanger spacing to maximize advective heat transfer. [Internet] [Masters thesis]. University of Minnesota; 2013. [cited 2019 Jul 17]. Available from: http://hdl.handle.net/11299/162371.

Council of Science Editors:

Meester J. Optimizing borehole Heat exchanger spacing to maximize advective heat transfer. [Masters Thesis]. University of Minnesota; 2013. Available from: http://hdl.handle.net/11299/162371


University of Ontario Institute of Technology

17. Lipchitz, Adam. Electrohydrodynamic enhancement of extraterrestrial capilliary pumped loops for nuclear applications.

Degree: 2010, University of Ontario Institute of Technology

 This work examines electrohydrodynamic enhancement of capillary pump loops (CPL) for use in extraterrestrial nuclear applications. A capillary pump uses capillary action through a porous… (more)

Subjects/Keywords: Heat transfer; Electrohydrodynamics; Capillary pump loops; EHD gas pumps; Extraterrestrial

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Lipchitz, A. (2010). Electrohydrodynamic enhancement of extraterrestrial capilliary pumped loops for nuclear applications. (Thesis). University of Ontario Institute of Technology. Retrieved from http://hdl.handle.net/10155/137

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Lipchitz, Adam. “Electrohydrodynamic enhancement of extraterrestrial capilliary pumped loops for nuclear applications.” 2010. Thesis, University of Ontario Institute of Technology. Accessed July 17, 2019. http://hdl.handle.net/10155/137.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Lipchitz, Adam. “Electrohydrodynamic enhancement of extraterrestrial capilliary pumped loops for nuclear applications.” 2010. Web. 17 Jul 2019.

Vancouver:

Lipchitz A. Electrohydrodynamic enhancement of extraterrestrial capilliary pumped loops for nuclear applications. [Internet] [Thesis]. University of Ontario Institute of Technology; 2010. [cited 2019 Jul 17]. Available from: http://hdl.handle.net/10155/137.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Lipchitz A. Electrohydrodynamic enhancement of extraterrestrial capilliary pumped loops for nuclear applications. [Thesis]. University of Ontario Institute of Technology; 2010. Available from: http://hdl.handle.net/10155/137

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Colorado

18. Cutler, Dylan Spencer. Improved Modeling of Residential Air Conditioners and Heat Pumps for Energy Calculations.

Degree: MS, 2013, University of Colorado

  This thesis provides the capability for improved predictions of the annual energy use of residential air conditioners and heat pumps.The annual simulation engine -… (more)

Subjects/Keywords: air conditioners; energy; heat pumps; modeling; Architectural Engineering; Civil Engineering

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Cutler, D. S. (2013). Improved Modeling of Residential Air Conditioners and Heat Pumps for Energy Calculations. (Masters Thesis). University of Colorado. Retrieved from https://scholar.colorado.edu/cven_gradetds/272

Chicago Manual of Style (16th Edition):

Cutler, Dylan Spencer. “Improved Modeling of Residential Air Conditioners and Heat Pumps for Energy Calculations.” 2013. Masters Thesis, University of Colorado. Accessed July 17, 2019. https://scholar.colorado.edu/cven_gradetds/272.

MLA Handbook (7th Edition):

Cutler, Dylan Spencer. “Improved Modeling of Residential Air Conditioners and Heat Pumps for Energy Calculations.” 2013. Web. 17 Jul 2019.

Vancouver:

Cutler DS. Improved Modeling of Residential Air Conditioners and Heat Pumps for Energy Calculations. [Internet] [Masters thesis]. University of Colorado; 2013. [cited 2019 Jul 17]. Available from: https://scholar.colorado.edu/cven_gradetds/272.

Council of Science Editors:

Cutler DS. Improved Modeling of Residential Air Conditioners and Heat Pumps for Energy Calculations. [Masters Thesis]. University of Colorado; 2013. Available from: https://scholar.colorado.edu/cven_gradetds/272


Delft University of Technology

19. Laumans, C.J. Flexibilty of future energy scenarios:.

Degree: 2011, Delft University of Technology

 If the Netherlands wishes to achieve an 80% CO2 reduction by the year 2050, technologies such as heat pumps and electric vehicles will be required… (more)

Subjects/Keywords: flexibility; electricity grid; electricity network; heat pumps; electric vehicles

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Laumans, C. J. (2011). Flexibilty of future energy scenarios:. (Masters Thesis). Delft University of Technology. Retrieved from http://resolver.tudelft.nl/uuid:79801e1e-ef19-4136-963d-c149f11bf56b

Chicago Manual of Style (16th Edition):

Laumans, C J. “Flexibilty of future energy scenarios:.” 2011. Masters Thesis, Delft University of Technology. Accessed July 17, 2019. http://resolver.tudelft.nl/uuid:79801e1e-ef19-4136-963d-c149f11bf56b.

MLA Handbook (7th Edition):

Laumans, C J. “Flexibilty of future energy scenarios:.” 2011. Web. 17 Jul 2019.

Vancouver:

Laumans CJ. Flexibilty of future energy scenarios:. [Internet] [Masters thesis]. Delft University of Technology; 2011. [cited 2019 Jul 17]. Available from: http://resolver.tudelft.nl/uuid:79801e1e-ef19-4136-963d-c149f11bf56b.

Council of Science Editors:

Laumans CJ. Flexibilty of future energy scenarios:. [Masters Thesis]. Delft University of Technology; 2011. Available from: http://resolver.tudelft.nl/uuid:79801e1e-ef19-4136-963d-c149f11bf56b


University of Bath

20. Cooper, Samuel J. G. Thermodynamic analysis of air source heat pumps and micro combined heat and power units participating in a distributed energy future.

Degree: PhD, 2013, University of Bath

 Achieving the reductions in carbon dioxide emissions which are necessary will require improvements in the way in which domestic space heating is supplied. Air Source… (more)

Subjects/Keywords: 621.4025; air source heat pumps; micro combined heat and power; energy analysis; efficiency; carbon emissions

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Cooper, S. J. G. (2013). Thermodynamic analysis of air source heat pumps and micro combined heat and power units participating in a distributed energy future. (Doctoral Dissertation). University of Bath. Retrieved from https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.577742

Chicago Manual of Style (16th Edition):

Cooper, Samuel J G. “Thermodynamic analysis of air source heat pumps and micro combined heat and power units participating in a distributed energy future.” 2013. Doctoral Dissertation, University of Bath. Accessed July 17, 2019. https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.577742.

MLA Handbook (7th Edition):

Cooper, Samuel J G. “Thermodynamic analysis of air source heat pumps and micro combined heat and power units participating in a distributed energy future.” 2013. Web. 17 Jul 2019.

Vancouver:

Cooper SJG. Thermodynamic analysis of air source heat pumps and micro combined heat and power units participating in a distributed energy future. [Internet] [Doctoral dissertation]. University of Bath; 2013. [cited 2019 Jul 17]. Available from: https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.577742.

Council of Science Editors:

Cooper SJG. Thermodynamic analysis of air source heat pumps and micro combined heat and power units participating in a distributed energy future. [Doctoral Dissertation]. University of Bath; 2013. Available from: https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.577742

21. Wajman, Michal. Technical and Economical Analysis of Ground Source Heat Pump Systems with BHE in Poland.

Degree: Applied Thermodynamics and Refrigeration, 2011, KTHKTH

  Nowadays, Ground Source Heat Pumps (GSHPs) are more frequently acting as a main or the only device covering the building heat/cool demand. The most… (more)

Subjects/Keywords: Ground Source Heat Pumps; Borehole Heat Exchanger; Mechanical engineering; Maskinteknik; Environmental engineering; Miljöteknik

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Wajman, M. (2011). Technical and Economical Analysis of Ground Source Heat Pump Systems with BHE in Poland. (Thesis). KTHKTH. Retrieved from http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-33642

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Wajman, Michal. “Technical and Economical Analysis of Ground Source Heat Pump Systems with BHE in Poland.” 2011. Thesis, KTHKTH. Accessed July 17, 2019. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-33642.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Wajman, Michal. “Technical and Economical Analysis of Ground Source Heat Pump Systems with BHE in Poland.” 2011. Web. 17 Jul 2019.

Vancouver:

Wajman M. Technical and Economical Analysis of Ground Source Heat Pump Systems with BHE in Poland. [Internet] [Thesis]. KTHKTH; 2011. [cited 2019 Jul 17]. Available from: http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-33642.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Wajman M. Technical and Economical Analysis of Ground Source Heat Pump Systems with BHE in Poland. [Thesis]. KTHKTH; 2011. Available from: http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-33642

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Oklahoma State University

22. Xing, Lu. Analytical and Numerical Modeling of Foundation Heat Exchangers.

Degree: Mechanical & Aerospace Engineering, 2010, Oklahoma State University

 Foundation heat exchangers (FHX) are an alternative to more costly ground heat exchangers utilized in ground-source heat pump (GSHP) systems serving detached or semi-detached houses.… (more)

Subjects/Keywords: analytical model; foundation heat exchangers; ground source heat pumps; numerical model; soil temperature

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Xing, L. (2010). Analytical and Numerical Modeling of Foundation Heat Exchangers. (Thesis). Oklahoma State University. Retrieved from http://hdl.handle.net/11244/10092

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Xing, Lu. “Analytical and Numerical Modeling of Foundation Heat Exchangers.” 2010. Thesis, Oklahoma State University. Accessed July 17, 2019. http://hdl.handle.net/11244/10092.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Xing, Lu. “Analytical and Numerical Modeling of Foundation Heat Exchangers.” 2010. Web. 17 Jul 2019.

Vancouver:

Xing L. Analytical and Numerical Modeling of Foundation Heat Exchangers. [Internet] [Thesis]. Oklahoma State University; 2010. [cited 2019 Jul 17]. Available from: http://hdl.handle.net/11244/10092.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Xing L. Analytical and Numerical Modeling of Foundation Heat Exchangers. [Thesis]. Oklahoma State University; 2010. Available from: http://hdl.handle.net/11244/10092

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Texas – Austin

23. Balasubramanian, Siddharth. Supplemental heat rejection in ground source heat pumps for residential houses in Texas and other semi-arid regions.

Degree: Mechanical Engineering, 2011, University of Texas – Austin

 Ground source heat pumps (GSHP) are efficient alternatives to air source heat pumps to provide heating and cooling for conditioned buildings. GSHPs are widely deployed… (more)

Subjects/Keywords: Supplemental heat rejection; Hybrid ground source heat pumps; Expanded desuperheater; Vapor compression cycle optimization

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Balasubramanian, S. (2011). Supplemental heat rejection in ground source heat pumps for residential houses in Texas and other semi-arid regions. (Thesis). University of Texas – Austin. Retrieved from http://hdl.handle.net/2152/ETD-UT-2011-12-4881

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Balasubramanian, Siddharth. “Supplemental heat rejection in ground source heat pumps for residential houses in Texas and other semi-arid regions.” 2011. Thesis, University of Texas – Austin. Accessed July 17, 2019. http://hdl.handle.net/2152/ETD-UT-2011-12-4881.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Balasubramanian, Siddharth. “Supplemental heat rejection in ground source heat pumps for residential houses in Texas and other semi-arid regions.” 2011. Web. 17 Jul 2019.

Vancouver:

Balasubramanian S. Supplemental heat rejection in ground source heat pumps for residential houses in Texas and other semi-arid regions. [Internet] [Thesis]. University of Texas – Austin; 2011. [cited 2019 Jul 17]. Available from: http://hdl.handle.net/2152/ETD-UT-2011-12-4881.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Balasubramanian S. Supplemental heat rejection in ground source heat pumps for residential houses in Texas and other semi-arid regions. [Thesis]. University of Texas – Austin; 2011. Available from: http://hdl.handle.net/2152/ETD-UT-2011-12-4881

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

24. Marmaras, Justin M. Measurement and Verification - Retro-Commissioning of a LEED Gold Rated Building Through Means of an Energy Model: Are Aggressive Energy Simulation Models Reliable?.

Degree: 2014, University of Massachusetts

  During the construction of the new 3 story, 25,000+ square foot police station, a decision was made to participate in the LEED program to… (more)

Subjects/Keywords: Energy; Heat Pumps; Energy Model; M&V; Metering; Retro-commsiioning; Energy Systems; Heat Transfer, Combustion

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Marmaras, J. M. (2014). Measurement and Verification - Retro-Commissioning of a LEED Gold Rated Building Through Means of an Energy Model: Are Aggressive Energy Simulation Models Reliable?. (Thesis). University of Massachusetts. Retrieved from https://scholarworks.umass.edu/masters_theses_2/31

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Marmaras, Justin M. “Measurement and Verification - Retro-Commissioning of a LEED Gold Rated Building Through Means of an Energy Model: Are Aggressive Energy Simulation Models Reliable?.” 2014. Thesis, University of Massachusetts. Accessed July 17, 2019. https://scholarworks.umass.edu/masters_theses_2/31.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Marmaras, Justin M. “Measurement and Verification - Retro-Commissioning of a LEED Gold Rated Building Through Means of an Energy Model: Are Aggressive Energy Simulation Models Reliable?.” 2014. Web. 17 Jul 2019.

Vancouver:

Marmaras JM. Measurement and Verification - Retro-Commissioning of a LEED Gold Rated Building Through Means of an Energy Model: Are Aggressive Energy Simulation Models Reliable?. [Internet] [Thesis]. University of Massachusetts; 2014. [cited 2019 Jul 17]. Available from: https://scholarworks.umass.edu/masters_theses_2/31.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Marmaras JM. Measurement and Verification - Retro-Commissioning of a LEED Gold Rated Building Through Means of an Energy Model: Are Aggressive Energy Simulation Models Reliable?. [Thesis]. University of Massachusetts; 2014. Available from: https://scholarworks.umass.edu/masters_theses_2/31

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Windsor

25. Cvetkovski, Christopher G. Modelling of flow and heat transport in vertical loop ground heat exchangers.

Degree: MA, Civil and Environmental Engineering, 2014, University of Windsor

  The performance of ground source heat pumps relies greatly on the heat transfer efficiency throughout the ground loop configuration. Vertical ground loops can employ… (more)

Subjects/Keywords: Applied sciences; Coaxial; Computational fluid dynamics; Fluent; Geothermal enegry; Ground source heat pumps; U-bend

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Cvetkovski, C. G. (2014). Modelling of flow and heat transport in vertical loop ground heat exchangers. (Masters Thesis). University of Windsor. Retrieved from http://scholar.uwindsor.ca/etd/5158

Chicago Manual of Style (16th Edition):

Cvetkovski, Christopher G. “Modelling of flow and heat transport in vertical loop ground heat exchangers.” 2014. Masters Thesis, University of Windsor. Accessed July 17, 2019. http://scholar.uwindsor.ca/etd/5158.

MLA Handbook (7th Edition):

Cvetkovski, Christopher G. “Modelling of flow and heat transport in vertical loop ground heat exchangers.” 2014. Web. 17 Jul 2019.

Vancouver:

Cvetkovski CG. Modelling of flow and heat transport in vertical loop ground heat exchangers. [Internet] [Masters thesis]. University of Windsor; 2014. [cited 2019 Jul 17]. Available from: http://scholar.uwindsor.ca/etd/5158.

Council of Science Editors:

Cvetkovski CG. Modelling of flow and heat transport in vertical loop ground heat exchangers. [Masters Thesis]. University of Windsor; 2014. Available from: http://scholar.uwindsor.ca/etd/5158


University of Edinburgh

26. Grabowiecki, Piotr. Combined permeable pavement and ground source heat pump systems.

Degree: PhD, 2010, University of Edinburgh

 The PhD thesis focuses on the performance assessment of permeable pavement systems incorporating ground source heat pumps (GSHP). The relatively high variability of temperature in… (more)

Subjects/Keywords: ground source heat pumps; permeable pavement systems; temperature fluctuations; influent-effluent relationships

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Grabowiecki, P. (2010). Combined permeable pavement and ground source heat pump systems. (Doctoral Dissertation). University of Edinburgh. Retrieved from http://hdl.handle.net/1842/4649

Chicago Manual of Style (16th Edition):

Grabowiecki, Piotr. “Combined permeable pavement and ground source heat pump systems.” 2010. Doctoral Dissertation, University of Edinburgh. Accessed July 17, 2019. http://hdl.handle.net/1842/4649.

MLA Handbook (7th Edition):

Grabowiecki, Piotr. “Combined permeable pavement and ground source heat pump systems.” 2010. Web. 17 Jul 2019.

Vancouver:

Grabowiecki P. Combined permeable pavement and ground source heat pump systems. [Internet] [Doctoral dissertation]. University of Edinburgh; 2010. [cited 2019 Jul 17]. Available from: http://hdl.handle.net/1842/4649.

Council of Science Editors:

Grabowiecki P. Combined permeable pavement and ground source heat pump systems. [Doctoral Dissertation]. University of Edinburgh; 2010. Available from: http://hdl.handle.net/1842/4649


University of Manchester

27. Ali, Mohamed. Modelling the performance of horizontal heat exchanger of ground-coupled heat pump system with Egyptian conditions.

Degree: PhD, 2013, University of Manchester

 The aim of this work was to investigate the effect on horizontal ground heat exchanger performance of changing soil and load parameters, and pipe horizontal… (more)

Subjects/Keywords: 621.402; horizontal ground coupled heat pumps; Egyptian weather condition; soil thermophysical properties

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Ali, M. (2013). Modelling the performance of horizontal heat exchanger of ground-coupled heat pump system with Egyptian conditions. (Doctoral Dissertation). University of Manchester. Retrieved from https://www.research.manchester.ac.uk/portal/en/theses/modelling-the-performance-of-horizontal-heat-exchanger-of-groundcoupled-heat-pump-system-with-egyptian-conditions(4512120a-422c-464f-b2d9-7bccb68c2a37).html ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.570294

Chicago Manual of Style (16th Edition):

Ali, Mohamed. “Modelling the performance of horizontal heat exchanger of ground-coupled heat pump system with Egyptian conditions.” 2013. Doctoral Dissertation, University of Manchester. Accessed July 17, 2019. https://www.research.manchester.ac.uk/portal/en/theses/modelling-the-performance-of-horizontal-heat-exchanger-of-groundcoupled-heat-pump-system-with-egyptian-conditions(4512120a-422c-464f-b2d9-7bccb68c2a37).html ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.570294.

MLA Handbook (7th Edition):

Ali, Mohamed. “Modelling the performance of horizontal heat exchanger of ground-coupled heat pump system with Egyptian conditions.” 2013. Web. 17 Jul 2019.

Vancouver:

Ali M. Modelling the performance of horizontal heat exchanger of ground-coupled heat pump system with Egyptian conditions. [Internet] [Doctoral dissertation]. University of Manchester; 2013. [cited 2019 Jul 17]. Available from: https://www.research.manchester.ac.uk/portal/en/theses/modelling-the-performance-of-horizontal-heat-exchanger-of-groundcoupled-heat-pump-system-with-egyptian-conditions(4512120a-422c-464f-b2d9-7bccb68c2a37).html ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.570294.

Council of Science Editors:

Ali M. Modelling the performance of horizontal heat exchanger of ground-coupled heat pump system with Egyptian conditions. [Doctoral Dissertation]. University of Manchester; 2013. Available from: https://www.research.manchester.ac.uk/portal/en/theses/modelling-the-performance-of-horizontal-heat-exchanger-of-groundcoupled-heat-pump-system-with-egyptian-conditions(4512120a-422c-464f-b2d9-7bccb68c2a37).html ; http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.570294

28. Chiapello, Fausto. Commissioning and Experimental Analysis of Heat Pumps' Performance.

Degree: 2012, University of Illinois – Chicago

 Nowadays, heat pumps represent one of the most innovative and high performance available technologies. Applied on HVAC plants, which require the 6% of European total… (more)

Subjects/Keywords: commissioning; heat pumps; experimental analysis

…ABSTRACT Nowadays, heat pumps represent one of the most innovative and high performance… …it should be done, and which are the possible levels of detail. 2. Heat pumps HVAC plants… …analysis. The power factor is one of the most useful data in this survey. 6. Air-air heat pumps… …The main work is concentrated on air-water and water-water heat pumps; however, since the… …initial idea was to examine heat pumps in general, an air-air plant was visited and briefly… 

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Chiapello, F. (2012). Commissioning and Experimental Analysis of Heat Pumps' Performance. (Thesis). University of Illinois – Chicago. Retrieved from http://hdl.handle.net/10027/9183

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Chiapello, Fausto. “Commissioning and Experimental Analysis of Heat Pumps' Performance.” 2012. Thesis, University of Illinois – Chicago. Accessed July 17, 2019. http://hdl.handle.net/10027/9183.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Chiapello, Fausto. “Commissioning and Experimental Analysis of Heat Pumps' Performance.” 2012. Web. 17 Jul 2019.

Vancouver:

Chiapello F. Commissioning and Experimental Analysis of Heat Pumps' Performance. [Internet] [Thesis]. University of Illinois – Chicago; 2012. [cited 2019 Jul 17]. Available from: http://hdl.handle.net/10027/9183.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Chiapello F. Commissioning and Experimental Analysis of Heat Pumps' Performance. [Thesis]. University of Illinois – Chicago; 2012. Available from: http://hdl.handle.net/10027/9183

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


Brno University of Technology

29. Čapek, Martin. Vytápění polyfunkčního domu .

Degree: 2013, Brno University of Technology

 Úkolem zpracování bakalářské práce je řešení koncepce otopné soustavy s přípravou teplé vody polyfunkčního objektu a následného návrhu zdroje tepla. Stavba je samostatně stojící ve… (more)

Subjects/Keywords: Vytápění; tepelná čerpadla; nucené větrání; solární kolektory; Heating; heat pumps; forced ventilation; solar collectors

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Čapek, M. (2013). Vytápění polyfunkčního domu . (Thesis). Brno University of Technology. Retrieved from http://hdl.handle.net/11012/28941

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Čapek, Martin. “Vytápění polyfunkčního domu .” 2013. Thesis, Brno University of Technology. Accessed July 17, 2019. http://hdl.handle.net/11012/28941.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Čapek, Martin. “Vytápění polyfunkčního domu .” 2013. Web. 17 Jul 2019.

Vancouver:

Čapek M. Vytápění polyfunkčního domu . [Internet] [Thesis]. Brno University of Technology; 2013. [cited 2019 Jul 17]. Available from: http://hdl.handle.net/11012/28941.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Čapek M. Vytápění polyfunkčního domu . [Thesis]. Brno University of Technology; 2013. Available from: http://hdl.handle.net/11012/28941

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


University of Florida

30. Jo, Soo Woong. Numerical Simulations of Bubble Pumps for Diffusion-Absorption Refrigeration.

Degree: MS, Mechanical Engineering - Mechanical and Aerospace Engineering, 2012, University of Florida

 A bubble pump is a key component for diffusion-absorption refrigeration systems operating at a single pressure. Nevertheless, research focusing on bubble pumps is not widely… (more)

Subjects/Keywords: Ammonia; Boiling; Diameters; Heat flux; Liquids; Modeling; Pumps; Simulations; Vapors; Velocity; bubble  – pump

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Jo, S. W. (2012). Numerical Simulations of Bubble Pumps for Diffusion-Absorption Refrigeration. (Masters Thesis). University of Florida. Retrieved from http://ufdc.ufl.edu/UFE0043901

Chicago Manual of Style (16th Edition):

Jo, Soo Woong. “Numerical Simulations of Bubble Pumps for Diffusion-Absorption Refrigeration.” 2012. Masters Thesis, University of Florida. Accessed July 17, 2019. http://ufdc.ufl.edu/UFE0043901.

MLA Handbook (7th Edition):

Jo, Soo Woong. “Numerical Simulations of Bubble Pumps for Diffusion-Absorption Refrigeration.” 2012. Web. 17 Jul 2019.

Vancouver:

Jo SW. Numerical Simulations of Bubble Pumps for Diffusion-Absorption Refrigeration. [Internet] [Masters thesis]. University of Florida; 2012. [cited 2019 Jul 17]. Available from: http://ufdc.ufl.edu/UFE0043901.

Council of Science Editors:

Jo SW. Numerical Simulations of Bubble Pumps for Diffusion-Absorption Refrigeration. [Masters Thesis]. University of Florida; 2012. Available from: http://ufdc.ufl.edu/UFE0043901

[1] [2] [3] [4]

.