Advanced search options

Advanced Search Options 🞨

Browse by author name (“Author name starts with…”).

Find ETDs with:

in
/  
in
/  
in
/  
in

Written in Published in Earliest date Latest date

Sorted by

Results per page:

You searched for subject:( Amer cio). One record found.

Search Limiters

Last 2 Years | English Only

No search limiters apply to these results.

▼ Search Limiters


Universidade Estadual de Campinas

1. Oliveira, Sandro Guedes de, 1973-. Duas novas determina??es da constante de decaimento por fiss?o espont?nea do 238U, lambda f, utilizando-se t?cnicas de tra?os de fiss?o .

Degree: 2001, Universidade Estadual de Campinas

Resumo: A constante de desintegra??o do 238U por fiss?o espont?nea, l f, j? foi medida mais de 50 vezes sem que se chegasse a um acordo sobre o seu valor num?rico. Em geral, os resultados obtidos concentram-se em torno de dois valores: 7,0 e 8,5 x 10-17 a -1. Neste trabalho, as medidas de l f foram analisadas e os principais erros sistem?ticos afetando os resultados apresentados na literatura foram identificados. Especificamente dentro do M?todo dos Tra?os de Fiss?o (MTF), a dosimetria de n?utrons surge como a principal fonte de erros sistem?ticos. Duas novas medidas foram realizadas usando t?cnicas de tra?os de fiss?o, evitando os erros identificados em outras medidas. Na primeira determina??o, foram usados filmes finos de ur?nio natural como dos?metros de n?utrons. O resultado encontrado foi l f = (8,37 ? 0,17) x 10-17a -1. Na segunda medida, filmes infinitos dopados com 242 Pu foram usados como fonte de fragmentos de fiss?o para calibrar o detector usado na coleta de fragmentos de fiss?o espont?nea do 238U. O resultado encontrado foi l f (8,7 ? 0,4) x 10 -17 a-1. Ambos os valores concordam entre si e com o valor nominal 8,5 x 10 -17 a -1. A obten??o de um valor de l f usando t?cnicas de tra?os de fiss?o, mas sem irradia??o com n?utrons faz com que este resultado seja bastante confi?vel. O fato das duas medidas apresentarem valores concordantes ? um forte ind?cio de que a dosimetria com filmes finos de ur?nio produz resultados coerentes. Acreditamos por isso ter contribu?do para o prop?sito de tornar o MTF, um m?todo independente; Abstract: More than 50 determinations of the spontaneous fission decay constant of 238U, lf , have been published and no agreement has been reached among them. Most of the obtained values are placed around two central values: 7,0 and 8,5 x 10-17a-1. In this thesis, the published lf measurements have been analyzed and the main systematic error sources have been identified. Concerning the Fission Track Method (FTM), neutron dosimetry rises as the main systematic error source. Two new determinations have been carried out through fission track techniques, avoiding the errors found in the previous measurements. Thin films of natural uranium have been used as neutron dosimeters in the first determination. The value obtained in this experiment was lf= (8,37 ? 0,17) x 10-17a-1. In the second experiment, infinite films, loaded with 242 Pu, have been used as sources of fission fragments in order to calibrate the detector used for collecting 238U spontaneous fission fragments. The value found was lf= (8,7 ? 0,4) x 10-17 a-1. Both values agree between them and with the nominal value 8,5 x 10-17a-1 . The derivation of a lfvalue from a measurement using fission track techniques, but without neutron irradiation makes it more reliable. The fact that the two values are in agreement is an indicative that the dosimetry with thin uranium films yields coherent results. We believe this work has contributed to make the FTM, an independent method Advisors/Committee Members: Hadler Neto, Julio Cesar, 1947- (advisor), Dias, Mauro da Silva (committee member), Kawashita, Koji (committee member), Chinellato, Jos? Augusto (committee member), Covolan, Roberto Jos? Maria (committee member).

Subjects/Keywords: Fiss?o nuclear; Ur?nio; Data??o do tra?o de fiss?o; Plut?nio; Amer?cio

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Oliveira, Sandro Guedes de, 1. (2001). Duas novas determina??es da constante de decaimento por fiss?o espont?nea do 238U, lambda f, utilizando-se t?cnicas de tra?os de fiss?o . (Thesis). Universidade Estadual de Campinas. Retrieved from http://repositorio.unicamp.br/jspui/handle/REPOSIP/278137

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Oliveira, Sandro Guedes de, 1973-. “Duas novas determina??es da constante de decaimento por fiss?o espont?nea do 238U, lambda f, utilizando-se t?cnicas de tra?os de fiss?o .” 2001. Thesis, Universidade Estadual de Campinas. Accessed December 13, 2019. http://repositorio.unicamp.br/jspui/handle/REPOSIP/278137.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Oliveira, Sandro Guedes de, 1973-. “Duas novas determina??es da constante de decaimento por fiss?o espont?nea do 238U, lambda f, utilizando-se t?cnicas de tra?os de fiss?o .” 2001. Web. 13 Dec 2019.

Vancouver:

Oliveira, Sandro Guedes de 1. Duas novas determina??es da constante de decaimento por fiss?o espont?nea do 238U, lambda f, utilizando-se t?cnicas de tra?os de fiss?o . [Internet] [Thesis]. Universidade Estadual de Campinas; 2001. [cited 2019 Dec 13]. Available from: http://repositorio.unicamp.br/jspui/handle/REPOSIP/278137.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Oliveira, Sandro Guedes de 1. Duas novas determina??es da constante de decaimento por fiss?o espont?nea do 238U, lambda f, utilizando-se t?cnicas de tra?os de fiss?o . [Thesis]. Universidade Estadual de Campinas; 2001. Available from: http://repositorio.unicamp.br/jspui/handle/REPOSIP/278137

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

.