1. Zügner, Roland. Gait and motion analysis of hip arthroplasty. Validity, reliability and longterm results.

Degree: 2017, University of Gothenburg / Göteborgs Universitet

Introduction: Walking is one of the most fundamental activities of daily living in humans, when the hip joints transfer power between the lower extremities and the pelvis. Hip osteoarthritis (OA) will more or less influence this function and is increasing in an ageing population. Total hip arthroplasty (THA) is a common treatment for patients diagnosed with hip osteoarthritis when non-surgical treatments have failed. Optical tracking systems (OTS) based on cameras and force plates mounted in the floor have been used since the 1960s. The technique includes attachment of reflective markers with double-adhesive tape to the skin of the patient. Marker positions are recorded when the patient walks through a calibrated measurement volume. Material and methods: In Study I, hip joint movements were measured with two different dynamic motion analysis systems, an optical tracking system and roentgen stereophotogrammetric analysis (RSA) in 16 patients with THA. In Study II, three patient groups were examined to study if the reproducibility of meas-ured values differs depending on whether the hip joint is normal, has developed OA or has been replaced with a THA. The aim of Study III was to investigate the gait in 22 patients operated bilaterally with two different types of stems at the same occasion. In Study IV, 62 patients operated with a Madreporic Lord hip prosthesis between 1979 and 1986 were followed for an average period of 26 years. In Study V, gait analy-sis was performed using two different motion analysis systems, one based on an optical tracking system and one based on accelerometers. Forty-nine THA patients were simultaneously evaluated with both methods. Results: During active hip motions soft-tissue displacements caused an underestimation of the true skeletal motion (Study I). In Study II the hip motions in patients with OA showed inferior repeatability between different investigators compared with THA patients and healthy controls. The gait pattern in the THA patients had not returned to normal one to two years after the operation. Study III showed no differences in speed, step length and frequency, or regarding kinematics or kinetics between short and conventional stems. Although both hip joints were operated during one-stage bilateral THA, there was still a difference between gait patterns two years after surgery compared with controls. In Study IV, the follow-up showed an average HHS of 81 (SD 14) and a pain score of 41 (SD 5), despite that more than half of the patients had undergone a revision of the acetabular cup. Some hips, but not all showed pronounced loss of bone mineral density around the stem. In Study V the accelerometer system measured movements of the pelvis and knee joint that did not differ from the optical system. However, significantly smaller flexion-extension was recorded. Conclusion: This dissertation shows that the deviation from skeletal movements measured using OTS is smallest when measuring hip flexion-extension in patients with THA. OTS is able to distinguish patients with hip…

Subjects/Keywords: Gait analysis; Hip arthroplasty; Kinematics; Radiostereometric analysis; Hip osteoarthritis

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Zügner, R. (2017). Gait and motion analysis of hip arthroplasty. Validity, reliability and longterm results. (Thesis). University of Gothenburg / Göteborgs Universitet. Retrieved from http://hdl.handle.net/2077/53611

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Zügner, Roland. “Gait and motion analysis of hip arthroplasty. Validity, reliability and longterm results.” 2017. Thesis, University of Gothenburg / Göteborgs Universitet. Accessed April 21, 2018. http://hdl.handle.net/2077/53611.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Zügner, Roland. “Gait and motion analysis of hip arthroplasty. Validity, reliability and longterm results.” 2017. Web. 21 Apr 2018.

Vancouver:

Zügner R. Gait and motion analysis of hip arthroplasty. Validity, reliability and longterm results. [Internet] [Thesis]. University of Gothenburg / Göteborgs Universitet; 2017. [cited 2018 Apr 21]. Available from: http://hdl.handle.net/2077/53611.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Zügner R. Gait and motion analysis of hip arthroplasty. Validity, reliability and longterm results. [Thesis]. University of Gothenburg / Göteborgs Universitet; 2017. Available from: http://hdl.handle.net/2077/53611

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

.