Advanced search options

Advanced Search Options 🞨

Browse by author name (“Author name starts with…”).

Find ETDs with:

in
/  
in
/  
in
/  
in

Written in Published in Earliest date Latest date

Sorted by

Results per page:

Sorted by: relevance · author · university · dateNew search

You searched for +publisher:"NSYSU" +contributor:("Soon-Jyh Chang"). Showing records 1 – 8 of 8 total matches.

Search Limiters

Last 2 Years | English Only

No search limiters apply to these results.

▼ Search Limiters


NSYSU

1. Wang, Deng-Shian. A High-Voltage Multiplexer and A Successive-Approximation Register Analog to Digital Converter for BMS.

Degree: Master, Electrical Engineering, 2013, NSYSU

 This thesis includes two designs: A high-voltage (HV) multiplexer and a successive-approximation register ADC for Battery Management Systems (BMS). The proposed designs are implemented by… (more)

Subjects/Keywords: BMS; high-voltage multiplexer; charge redistribution architecture; successive-approximation register ADC; high-voltage switch

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Wang, D. (2013). A High-Voltage Multiplexer and A Successive-Approximation Register Analog to Digital Converter for BMS. (Thesis). NSYSU. Retrieved from http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0608113-213119

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Wang, Deng-Shian. “A High-Voltage Multiplexer and A Successive-Approximation Register Analog to Digital Converter for BMS.” 2013. Thesis, NSYSU. Accessed October 21, 2019. http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0608113-213119.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Wang, Deng-Shian. “A High-Voltage Multiplexer and A Successive-Approximation Register Analog to Digital Converter for BMS.” 2013. Web. 21 Oct 2019.

Vancouver:

Wang D. A High-Voltage Multiplexer and A Successive-Approximation Register Analog to Digital Converter for BMS. [Internet] [Thesis]. NSYSU; 2013. [cited 2019 Oct 21]. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0608113-213119.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Wang D. A High-Voltage Multiplexer and A Successive-Approximation Register Analog to Digital Converter for BMS. [Thesis]. NSYSU; 2013. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0608113-213119

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


NSYSU

2. Wu, Yi-hong. A 16-channel High-Voltage Stimulation Generator and A Pulse Frequency Modulation Boost Converter for Spinal Cord Stimulation Systems.

Degree: Master, Electrical Engineering, 2013, NSYSU

 This thesis consists of two topics, i.e., a 16-channel high-voltage stimulation generator and a pulse frequency modulation (PFM) boost converter, which are mainly designed for… (more)

Subjects/Keywords: stimulation waveform generator; current-limiting; minimum off time one-shot circuit; PFM boost converter; SCS

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Wu, Y. (2013). A 16-channel High-Voltage Stimulation Generator and A Pulse Frequency Modulation Boost Converter for Spinal Cord Stimulation Systems. (Thesis). NSYSU. Retrieved from http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0610113-114950

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Wu, Yi-hong. “A 16-channel High-Voltage Stimulation Generator and A Pulse Frequency Modulation Boost Converter for Spinal Cord Stimulation Systems.” 2013. Thesis, NSYSU. Accessed October 21, 2019. http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0610113-114950.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Wu, Yi-hong. “A 16-channel High-Voltage Stimulation Generator and A Pulse Frequency Modulation Boost Converter for Spinal Cord Stimulation Systems.” 2013. Web. 21 Oct 2019.

Vancouver:

Wu Y. A 16-channel High-Voltage Stimulation Generator and A Pulse Frequency Modulation Boost Converter for Spinal Cord Stimulation Systems. [Internet] [Thesis]. NSYSU; 2013. [cited 2019 Oct 21]. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0610113-114950.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Wu Y. A 16-channel High-Voltage Stimulation Generator and A Pulse Frequency Modulation Boost Converter for Spinal Cord Stimulation Systems. [Thesis]. NSYSU; 2013. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0610113-114950

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


NSYSU

3. Chen, Sih-Yu. Single-ended Disturb-free 5T Load-less 4Kb SRAM with Leakage Current Sensor and Compensation Circuit.

Degree: Master, Electrical Engineering, 2013, NSYSU

 This thesis consists of two topics, including a single-ended disturb-free 5T load-less 4Kb SRAM, and the leakage current sensor and compensation circuit mainly designed for… (more)

Subjects/Keywords: single-ended; leakage current sensor; power-delay product; load-less; disturb-free; leakage current compensation circuit

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Chen, S. (2013). Single-ended Disturb-free 5T Load-less 4Kb SRAM with Leakage Current Sensor and Compensation Circuit. (Thesis). NSYSU. Retrieved from http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0610113-114220

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Chen, Sih-Yu. “Single-ended Disturb-free 5T Load-less 4Kb SRAM with Leakage Current Sensor and Compensation Circuit.” 2013. Thesis, NSYSU. Accessed October 21, 2019. http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0610113-114220.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Chen, Sih-Yu. “Single-ended Disturb-free 5T Load-less 4Kb SRAM with Leakage Current Sensor and Compensation Circuit.” 2013. Web. 21 Oct 2019.

Vancouver:

Chen S. Single-ended Disturb-free 5T Load-less 4Kb SRAM with Leakage Current Sensor and Compensation Circuit. [Internet] [Thesis]. NSYSU; 2013. [cited 2019 Oct 21]. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0610113-114220.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Chen S. Single-ended Disturb-free 5T Load-less 4Kb SRAM with Leakage Current Sensor and Compensation Circuit. [Thesis]. NSYSU; 2013. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0610113-114220

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


NSYSU

4. Hu , Yi. A Receiver with Over-Voltage Protection for FlexRay Systems and an 8:1 High-Voltage Analog Multiplexer for Battery Management Systems.

Degree: Master, Electrical Engineering, 2013, NSYSU

 The research of this thesis is mainly focused on automotive electronics including two topics, a Receiver (Rx) with over-voltage protection for FlexRay systems and an… (more)

Subjects/Keywords: over-voltage protection; HV switches; FlexRay Receiver; BMS; HV MUX

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Hu , Y. (2013). A Receiver with Over-Voltage Protection for FlexRay Systems and an 8:1 High-Voltage Analog Multiplexer for Battery Management Systems. (Thesis). NSYSU. Retrieved from http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0610113-151412

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Hu , Yi. “A Receiver with Over-Voltage Protection for FlexRay Systems and an 8:1 High-Voltage Analog Multiplexer for Battery Management Systems.” 2013. Thesis, NSYSU. Accessed October 21, 2019. http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0610113-151412.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Hu , Yi. “A Receiver with Over-Voltage Protection for FlexRay Systems and an 8:1 High-Voltage Analog Multiplexer for Battery Management Systems.” 2013. Web. 21 Oct 2019.

Vancouver:

Hu Y. A Receiver with Over-Voltage Protection for FlexRay Systems and an 8:1 High-Voltage Analog Multiplexer for Battery Management Systems. [Internet] [Thesis]. NSYSU; 2013. [cited 2019 Oct 21]. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0610113-151412.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Hu Y. A Receiver with Over-Voltage Protection for FlexRay Systems and an 8:1 High-Voltage Analog Multiplexer for Battery Management Systems. [Thesis]. NSYSU; 2013. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0610113-151412

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


NSYSU

5. Tseng, Shao-Bin. Design of One-Time Implantable SCS System SOC and Inter-chip Capacitance Coupling Circuit.

Degree: Master, Electrical Engineering, 2011, NSYSU

 The thesis is composed of two topics: A SOC design for one-time implantable spinal cord stimulation system ï¼SCSï¼, and the design of an inter-chip capacitance… (more)

Subjects/Keywords: bidirectional communication; capacitive coupling; multiple modes; SCS; high-speed data transceiver; ASK demodulator

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Tseng, S. (2011). Design of One-Time Implantable SCS System SOC and Inter-chip Capacitance Coupling Circuit. (Thesis). NSYSU. Retrieved from http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0815111-233024

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Tseng, Shao-Bin. “Design of One-Time Implantable SCS System SOC and Inter-chip Capacitance Coupling Circuit.” 2011. Thesis, NSYSU. Accessed October 21, 2019. http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0815111-233024.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Tseng, Shao-Bin. “Design of One-Time Implantable SCS System SOC and Inter-chip Capacitance Coupling Circuit.” 2011. Web. 21 Oct 2019.

Vancouver:

Tseng S. Design of One-Time Implantable SCS System SOC and Inter-chip Capacitance Coupling Circuit. [Internet] [Thesis]. NSYSU; 2011. [cited 2019 Oct 21]. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0815111-233024.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Tseng S. Design of One-Time Implantable SCS System SOC and Inter-chip Capacitance Coupling Circuit. [Thesis]. NSYSU; 2011. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0815111-233024

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


NSYSU

6. Yeh, Tai-Hao. A High Speed Transceiver Front-end Design with Fault Detection and Temperature Detector for FlexRay-based Automotive Communication Systems.

Degree: Master, Communications Engineering, 2011, NSYSU

 This thesis is composed of two parts: a high-speed transceiver front-end design with fault detection for FlexRay-based automative communication systems, and a temperature detector. In… (more)

Subjects/Keywords: FlexRay; transceiver; automobile electronics; failure detection; temperature detection

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Yeh, T. (2011). A High Speed Transceiver Front-end Design with Fault Detection and Temperature Detector for FlexRay-based Automotive Communication Systems. (Thesis). NSYSU. Retrieved from http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0817111-152114

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Yeh, Tai-Hao. “A High Speed Transceiver Front-end Design with Fault Detection and Temperature Detector for FlexRay-based Automotive Communication Systems.” 2011. Thesis, NSYSU. Accessed October 21, 2019. http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0817111-152114.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Yeh, Tai-Hao. “A High Speed Transceiver Front-end Design with Fault Detection and Temperature Detector for FlexRay-based Automotive Communication Systems.” 2011. Web. 21 Oct 2019.

Vancouver:

Yeh T. A High Speed Transceiver Front-end Design with Fault Detection and Temperature Detector for FlexRay-based Automotive Communication Systems. [Internet] [Thesis]. NSYSU; 2011. [cited 2019 Oct 21]. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0817111-152114.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Yeh T. A High Speed Transceiver Front-end Design with Fault Detection and Temperature Detector for FlexRay-based Automotive Communication Systems. [Thesis]. NSYSU; 2011. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0817111-152114

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


NSYSU

7. Lin, Yain-Reu. Low Power Half-Run RC5 Cipher Circuit for Portable Biomedical Device and A Frequency-Shift Readout Circuit for FPW-Based Biosensors.

Degree: Master, Electrical Engineering, 2011, NSYSU

 This thesis consists of two topics. We proposed a low power half-run RC5 cipher for portable biomedical devices in the first part of this thesis.… (more)

Subjects/Keywords: frequency-shift readout system; RC5; flexural plate wave; biomedical system; low power; ZigBee

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Lin, Y. (2011). Low Power Half-Run RC5 Cipher Circuit for Portable Biomedical Device and A Frequency-Shift Readout Circuit for FPW-Based Biosensors. (Thesis). NSYSU. Retrieved from http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0808111-162539

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Chicago Manual of Style (16th Edition):

Lin, Yain-Reu. “Low Power Half-Run RC5 Cipher Circuit for Portable Biomedical Device and A Frequency-Shift Readout Circuit for FPW-Based Biosensors.” 2011. Thesis, NSYSU. Accessed October 21, 2019. http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0808111-162539.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

MLA Handbook (7th Edition):

Lin, Yain-Reu. “Low Power Half-Run RC5 Cipher Circuit for Portable Biomedical Device and A Frequency-Shift Readout Circuit for FPW-Based Biosensors.” 2011. Web. 21 Oct 2019.

Vancouver:

Lin Y. Low Power Half-Run RC5 Cipher Circuit for Portable Biomedical Device and A Frequency-Shift Readout Circuit for FPW-Based Biosensors. [Internet] [Thesis]. NSYSU; 2011. [cited 2019 Oct 21]. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0808111-162539.

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation

Council of Science Editors:

Lin Y. Low Power Half-Run RC5 Cipher Circuit for Portable Biomedical Device and A Frequency-Shift Readout Circuit for FPW-Based Biosensors. [Thesis]. NSYSU; 2011. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0808111-162539

Note: this citation may be lacking information needed for this citation format:
Not specified: Masters Thesis or Doctoral Dissertation


NSYSU

8. Lu, Wen-Je. Mixed-Voltage Output Buffer with Process, Voltage, and Temperature Detectors for Slew Rate Compensation.

Degree: PhD, Electrical Engineering, 2015, NSYSU

 Many digital devices such as universal serial bus, bluetooth, and digital audio player have been widely used in human daily life. Nanoscale complementary metal-oxide-semiconductor (CMOS)… (more)

Subjects/Keywords: corner; skew inverters; slew rate; output buffer; high operating speed; complementary metal-oxide-semiconductor

Record DetailsSimilar RecordsGoogle PlusoneFacebookTwitterCiteULikeMendeleyreddit

APA · Chicago · MLA · Vancouver · CSE | Export to Zotero / EndNote / Reference Manager

APA (6th Edition):

Lu, W. (2015). Mixed-Voltage Output Buffer with Process, Voltage, and Temperature Detectors for Slew Rate Compensation. (Doctoral Dissertation). NSYSU. Retrieved from http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0609115-192651

Chicago Manual of Style (16th Edition):

Lu, Wen-Je. “Mixed-Voltage Output Buffer with Process, Voltage, and Temperature Detectors for Slew Rate Compensation.” 2015. Doctoral Dissertation, NSYSU. Accessed October 21, 2019. http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0609115-192651.

MLA Handbook (7th Edition):

Lu, Wen-Je. “Mixed-Voltage Output Buffer with Process, Voltage, and Temperature Detectors for Slew Rate Compensation.” 2015. Web. 21 Oct 2019.

Vancouver:

Lu W. Mixed-Voltage Output Buffer with Process, Voltage, and Temperature Detectors for Slew Rate Compensation. [Internet] [Doctoral dissertation]. NSYSU; 2015. [cited 2019 Oct 21]. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0609115-192651.

Council of Science Editors:

Lu W. Mixed-Voltage Output Buffer with Process, Voltage, and Temperature Detectors for Slew Rate Compensation. [Doctoral Dissertation]. NSYSU; 2015. Available from: http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0609115-192651

.